Current gradient-index(GRIN)lens based proximal-driven intracoronary optical coherence tomography(ICOCT)probes consist of a spacer and a GRIN lens with large gradient constant.This design provides great flexibility to...Current gradient-index(GRIN)lens based proximal-driven intracoronary optical coherence tomography(ICOCT)probes consist of a spacer and a GRIN lens with large gradient constant.This design provides great flexibility to control beam profiles,but the spacer length should be well controlled to obtain desired beam profiles and thus it sets an obstacle in mass catheter fabrication.Besides,although GRIN lens with large gradient constant can provide tight focus spot,it has short depth of focus and fast-expanded beam which leads to poor lateral resolution for deep tissue.In this paper,a type of spacer-removed probe is demonstrated with a small gradient constant GRIN lens.This design simplifies the fabrica-tion process and is suitable for mass production.The output beam of the catheter is a narrow nearly collimated light beam,referred to as pencil beam here.The full width at half maximum beam size varies from 35.1μm to 75.3μm in air over 3-mm range.Probe design principles are elaborated with probe/catheter fabrication and performance test.The in vivo imaging of the catheter was verified by a clinical ICOCT system.Those results prove that this novel pencil-beam scanning catheter is potentially a good choice for ICOCT systems.展开更多
A comprehensive study on the requirements for the highly efficient third harmonic generation(THG) and its inverse process, one-third harmonic generation(OTHG), in lossy waveguides is proposed. The field intensity rest...A comprehensive study on the requirements for the highly efficient third harmonic generation(THG) and its inverse process, one-third harmonic generation(OTHG), in lossy waveguides is proposed. The field intensity restrictions for both THG and OTHG caused by loss are demonstrated. The effective relative phase ranges, supporting the positive growth of signal fields of THG and OTHG are shrunken by the loss. Furthermore, it turns out that the effective relative phase ranges depend on the intensities of the interacting fields. At last, a modified definition of coherent length in loss situation, which evaluates the phase matching degree more precisely, is proposed by incorporating the shrunken relative phase range and the nonlinear phase mismatch. These theoretical analysis are valuable for guiding the experimental designs for highly efficient THG and OTHG.展开更多
基金financial supports from the National Natural Science Foundation of China(Grant No.81927805)Shenzhen Municipal Science and Technology Plan Project,China(Grant No.JCYJ20160427183803458)。
文摘Current gradient-index(GRIN)lens based proximal-driven intracoronary optical coherence tomography(ICOCT)probes consist of a spacer and a GRIN lens with large gradient constant.This design provides great flexibility to control beam profiles,but the spacer length should be well controlled to obtain desired beam profiles and thus it sets an obstacle in mass catheter fabrication.Besides,although GRIN lens with large gradient constant can provide tight focus spot,it has short depth of focus and fast-expanded beam which leads to poor lateral resolution for deep tissue.In this paper,a type of spacer-removed probe is demonstrated with a small gradient constant GRIN lens.This design simplifies the fabrica-tion process and is suitable for mass production.The output beam of the catheter is a narrow nearly collimated light beam,referred to as pencil beam here.The full width at half maximum beam size varies from 35.1μm to 75.3μm in air over 3-mm range.Probe design principles are elaborated with probe/catheter fabrication and performance test.The in vivo imaging of the catheter was verified by a clinical ICOCT system.Those results prove that this novel pencil-beam scanning catheter is potentially a good choice for ICOCT systems.
基金Project supported by Shenzhen Municipal Science and Technology Plan Project,China(Grant Nos.JCYJ20160427183803458 and JCYJ20150403161923546)
文摘A comprehensive study on the requirements for the highly efficient third harmonic generation(THG) and its inverse process, one-third harmonic generation(OTHG), in lossy waveguides is proposed. The field intensity restrictions for both THG and OTHG caused by loss are demonstrated. The effective relative phase ranges, supporting the positive growth of signal fields of THG and OTHG are shrunken by the loss. Furthermore, it turns out that the effective relative phase ranges depend on the intensities of the interacting fields. At last, a modified definition of coherent length in loss situation, which evaluates the phase matching degree more precisely, is proposed by incorporating the shrunken relative phase range and the nonlinear phase mismatch. These theoretical analysis are valuable for guiding the experimental designs for highly efficient THG and OTHG.