期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
基于过程免疫时间的半导体企业电压暂降经济损失预评估方法 被引量:17
1
作者 张旭彬 张逸 +3 位作者 张孔林 李为明 郭庆波 李俭华 《电工电能新技术》 CSCD 北大核心 2018年第6期43-49,共7页
电压暂降已成为最严重的电能质量问题,给用户带来了极大的经济损失。国内外目前针对半导体企业电压暂降经济损失预评估的研究较少,为此本文提出一种基于过程免疫时间的实用评估方法。首先,以液晶屏面板为研究对象,应用故障树分析法对半... 电压暂降已成为最严重的电能质量问题,给用户带来了极大的经济损失。国内外目前针对半导体企业电压暂降经济损失预评估的研究较少,为此本文提出一种基于过程免疫时间的实用评估方法。首先,以液晶屏面板为研究对象,应用故障树分析法对半导体复杂的生产过程进行分解以确定关键设备的逻辑连接关系;其次,结合实测的设备过程免疫时间和逻辑连接关系推算生产过程的综合过程免疫时间;再次,依据历史电压暂降监测数据和综合过程免疫时间预测生产过程中断次数;最后,结合生产过程中断次数和单次中断经济损失预估用户总经济损失值。实例分析结果验证了所提方法符合工程实际,具备可行性,对新投建的半导体生产线选择电压暂降治理方案、制定生产计划具有参考意义。 展开更多
关键词 半导体 电压暂降 经济损失预评估 过程免疫时间 生产过程中断
下载PDF
Application of Voltage Response Method to Condition Assessment of Power Transformer 被引量:2
2
作者 zhang Tao CAI Jin-ding zhang kong-lin 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2674-2680,共7页
Power transformer is one of the most important equipment in the power system.Its operating condition affects the reliability of power supply directly.Therefore,in order to guarantee transformer operation safely and re... Power transformer is one of the most important equipment in the power system.Its operating condition affects the reliability of power supply directly.Therefore,in order to guarantee transformer operation safely and reliably,it is necessary to assess condition of power transformer accurately.Return voltage method based on voltage response measurements is still a new non-intrusive diagnosis method for internal insulation aging of transformer.In this paper the technique and application of return voltage measurement and some results of voltage response measurements of several transformers was introduced.Voltage response measurements were performed on various transformers with different voltage grades,various operating periods,different moisture contents and aging degrees on site.Derived moisture contents from return voltage measurement were compared with the corresponding moisture contents obtained from the analysis of oil samples.Based on on-site experiments and theoretical analysis,the criteria for insulation state of transformer are proposed.Moisture condition of transformer insulation can be determined by using return dominant time constant,and a good correlation between aging degree and the return voltage initial slopes of the aged transformers.Field test performed on several transformers,its interpretation of results are also presented,which proves that return voltage measurements can be used as a reliable tool for evaluating moisture content in transformer insulation. 展开更多
关键词 电压响应方法 电力变压器 评估 RVM 起始斜率 故障诊断
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部