期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Rheological Properties and Structural Changes in Different Sections of Boiled Abalone Meat 被引量:7
1
作者 GAOXin TANGZhixu +1 位作者 zhangzhaohui OgawaHiroo 《Journal of Ocean University of Qingdao》 2003年第1期44-48,共5页
Changes in tissue structures, rheological properties of cross- and vertical section boiled abalone meat were studied in relation to boiling time. The adductor muscle of abalone Haliotis discus which was removed from t... Changes in tissue structures, rheological properties of cross- and vertical section boiled abalone meat were studied in relation to boiling time. The adductor muscle of abalone Haliotis discus which was removed from the shell, was boiled for 1, 2, and 3 h, respectively. Then it was cut up and separated into cross- and vertical section meat. When observed by a light microscope and a scanning electron microscope, structural changes in the myofibrils were greatest in the cross section meat compared with the vertical section meat. When boiling time was increased from 1 h to 3 h, the instantaneous modulus E 0 and rupture strength of both section meat decreased gradually with increased boiling time, and no significant differences were observed between these two section meat for the same boiling time. When boiled for 1 h, the relaxation time of cross section meat was much longer than that of vertical section meat. There were no significant changes in the relaxation time of vertical section for different boiling time, but the relaxation time of cross section meat was reduced gradually with increasing boiling time. These results confirmed that the difference in rheological properties between the cross- and vertical section meat was mainly due to the denaturation level of myofibrils when heated for 1 h, as well as due to the changes in the amount of denatured proteins, and the manner in which the inner denatured protein components weve exchanged after boiling time was increased from 1 h to 3 h. 展开更多
关键词 ABALONE MEAT BOILING RHEOLOGY
下载PDF
Determination of Trace Germanium in Marine Sediments by Hydride Generation-Atomic Fluorescence Spectrometry (HG-AFS) 被引量:2
2
作者 LIJing ZHAOShilan +1 位作者 zhangzhaohui ZENGXianjie 《Journal of Ocean University of China》 SCIE CAS 2004年第2期179-182,共4页
A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier g... A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier gas flow rate, etc., were tested and optimized by using a kind of orthogonal design. The detection limit of the presented method is 0.95 μg L -1 for germanium. The calibration curve shows a satisfactory line in the concentration range 0-320 μg L -1 Ge with a variation coefficient of ±2.1%. 展开更多
关键词 hydride generation-atomic fluorescence spectrometry (HG-AFS) GERMANIUM marine sediment TRACE
下载PDF
Researches on the Stability of Porphyra-334 Solution and Its Influence Factors 被引量:1
3
作者 zhangzhaohui GAOXin +2 位作者 YuriTashiro ShingoMatsukawa HirooOgawa 《Journal of Ocean University of China》 SCIE CAS 2004年第2期166-170,共5页
The stability of porphyra-334 in solutions of different pH values at different temperatures was studied. In high acidic conditions, below pH 3, the absorption maximum, λ max, of porphyra-334 shows hypsochromic shift ... The stability of porphyra-334 in solutions of different pH values at different temperatures was studied. In high acidic conditions, below pH 3, the absorption maximum, λ max, of porphyra-334 shows hypsochromic shift towards lower wavelength and the absorbance also has a light decrease. In high alkaline conditions of over pH 12, the absorbance of porphyra-334 decreases and an unknown compound with a peak maximum at 225 nm appears. The peak height of the unknown compound increases with the decrease of absorbance of porphyra-334. This might be related to the decomposition of porphyra-334. At room temperature, porphyra-334 solutions, except high alkaline solutions, are stable. Increasing the temperature, especially higher than 60℃, promotes the decomposition of porphyra-334 and causes the absorbance decrease both in basic and acidic solutions. 展开更多
关键词 porphyra-334 STABILITY EXTRACTION absorption spectrum action mechanism
下载PDF
预应力混凝土闸墩结构的预应力损失计算方法
4
作者 张召辉 段传武 李树山 《河南科技》 2018年第13期84-87,共4页
预应力混凝土具有良好的抗裂性能,在水工结构中得到广泛的应用。本文以预应力混凝土闸墩结构为例,分析了影响预应力损失的多种因素和各项预应力损失计算公式的适用性,并结合实例,与多个工程实例的对比分析,认为闸墩结构预应力损失... 预应力混凝土具有良好的抗裂性能,在水工结构中得到广泛的应用。本文以预应力混凝土闸墩结构为例,分析了影响预应力损失的多种因素和各项预应力损失计算公式的适用性,并结合实例,与多个工程实例的对比分析,认为闸墩结构预应力损失的理论计算方法偏于安全,能够满足预应力闸墩设计与施工分析要求。 展开更多
关键词 闸墩 预应力混凝土 预应力损失 收缩 徐变
下载PDF
To the Left or the Right?
5
作者 zhangzhaohui 《China Today》 2004年第4期52-55,共4页
THE Left Bank Gallery in the Zhongguancun area of Beijing's Haidian District unveiled “The Left-Wing” in late December 2003. The gallery housed the exhibit two huge concrete floors within a commercialreal estate... THE Left Bank Gallery in the Zhongguancun area of Beijing's Haidian District unveiled “The Left-Wing” in late December 2003. The gallery housed the exhibit two huge concrete floors within a commercialreal estate project called Left Bank. 展开更多
关键词 北京 艺术展览 时代精神 艺术风格
下载PDF
Atomic force microscopy observation on nuclear reassembly in a cell-free system
6
作者 YANGNing CHENZhongcai +3 位作者 zhangzhaohui ZHUXing ZHAIZhonghe TANGXiaowei 《Chinese Science Bulletin》 SCIE EI CAS 2003年第21期2284-2287,共4页
Cell-free system is interesting and useful for studying nuclear assembly in mitosis. Atomic force micro- scopy (AFM), which is a simple way for imaging fixed reas-semble nuclei with high resolution, has not been used ... Cell-free system is interesting and useful for studying nuclear assembly in mitosis. Atomic force micro- scopy (AFM), which is a simple way for imaging fixed reas-semble nuclei with high resolution, has not been used in the cell-free system. In this paper, we put forward an air-drying sample preparation for AFM. Using AFM, we observed nu-clear reassembly process within 100 nm resolution in a cell-free system. As a result, we found that the images were artifact-free, and with higher resolution compared with fluo-rescent optical microscope images. Furthermore, the mor-phology of membrane vesicles was obtained clearly, and a dynamic change of morphology during the vesicles?ap-proaching to nuclear envelope was also observed, which is enlightened to understand the mechanism of nuclear enve-lope assembly. 展开更多
关键词 AFM 原子压力显微镜法 有丝分裂 细胞核重组
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部