Droplet shear stress is considered as an important indicator that reflects soil erosion in sprinkler irrigation more accurately than kinetic energy,and the effect of droplet impact angle on the shear stress cannot be ...Droplet shear stress is considered as an important indicator that reflects soil erosion in sprinkler irrigation more accurately than kinetic energy,and the effect of droplet impact angle on the shear stress cannot be ignored.In this study,radial distribution of droplet impact angles,velocities,and shear stresses were investigated using a two-dimensional video disdrometer with three types of low-pressure sprinkler(Nelson D3000,R3000,and Komet KPT)under two operating pressures(103 and 138 kPa)and three nozzle diameters(3.97,5.95,and 7.94 mm).Furthermore,the relationships among these characteristical parameters of droplet were analyzed,and their influencing factors were comprehensively evaluated.For various types of sprinkler,operating pressures,and nozzle diameters,the smaller impact angles and larger velocities of droplets were found to occur closer to the sprinkler,resulting in relatively low droplet shear stresses.The increase in distance from the sprinkler caused the droplet impact angle to decrease and velocity to increase,which contributed to a significant increase in the shear stress that reached the peak value at the end of the jet.Therefore,the end of the jet was the most prone to soil erosion in the radial direction,and the soil erosion in sprinkler irrigation could not only be attributed to the droplet kinetic energy,but also needed to be combined with the analysis of its shear stress.Through comparing the radial distributions of average droplet shear stresses among the three types of sprinklers,D3000 exhibited the largest value(26.94-3313.51 N/m^(2)),followed by R3000(33.34-2650.80 N/m^(2)),and KPT(16.15-2485.69 N/m^(2)).From the perspective of minimizing the risk of soil erosion,KPT sprinkler was more suitable for low-pressure sprinkler irrigation than D3000 and R3000 sprinklers.In addition to selecting the appropriate sprinkler type to reduce the droplet shear stress,a suitable sprinkler spacing could also provide acceptable results,because the distance from the sprinkler exhibited a highly significant(P<0.01)effect on the shear stress.This study results provide a new reference for the design of low-pressure sprinkler irrigation system.展开更多
These years Yuangong copper-bearing intrauterine devices (Cu-IUDs) have been used because of less side effects in use. The corrosion of copper is essential to the success of contraception, and the release behavior of ...These years Yuangong copper-bearing intrauterine devices (Cu-IUDs) have been used because of less side effects in use. The corrosion of copper is essential to the success of contraception, and the release behavior of indomethacin from medicated Cu-IUD is related to its therapeutic effect. In this study, analytical methods were established to investigate the release behavior of cupric ion of three kinds of Yuangong Cu-IUDs and indomethacin of medicated Yuangong 220 Cu-IUD. Cu-IUDs were incubated in simulated uterine solution (SUS). The concentrations of cupric ion and indomethacin were analyzed by flame atomic absorption spectrometer (FAAS) for 60 days and UV/vis ?3310 spectrophotometer for 60 days, respectively. The morphology of copper after corrosion was characterized by SEM. In addition, we detected cytotoxicity by MTT of L929 mouse fibroblasts cells caused by extracts of the three Yuangong Cu-IUDs. The release behavior of cupric ion for three kinds of Yuangong Cu-IUDs was biphasic, which consisted of the initial burst release and then slow and constant release. In vitro release experiment confirmed a biphasic release of indomethacin from Yuangong 220. The copper wire of Yuangong Cu-IUDs showed uneven corrosion. The RGR value of Yuangong 365 Cu-IUD was smaller than that of medicated Yuangong 220 Cu-IUD and RGR value of medicated Yuangong 220 Cu-IUD was smaller than that of Yuangong 300 Cu-IUD. The cupric ion release and indomethacin release showed biphasic. Indomethacin increased the cupric ion release rate and might diminish the adverse effects caused by burst release of cupric ion. The toxicity grade of these three Yuangong Cu-IUDs was 4. We should canvass the adverse events of Cu-IUDs based on practical experiments, and try our best to reduce the toxicity of Cu-IUDs.展开更多
基金the National Natural Science Foundation of China(51939005)the Key Research and Development Program of Hebei Province,China(21327002D)+2 种基金the Hebei Forage Industry Innovation Team of Modern Agro-industry Technology Research System of China(HBCT2018160202)the Regional Collaborative Innovation Project of Xinjiang Uygur Autonomous Region of China(2021E02056)the China Agriculture Research System of Ministry of Finance and Ministry of Agriculture and Rural Affairs(CARS-34).
文摘Droplet shear stress is considered as an important indicator that reflects soil erosion in sprinkler irrigation more accurately than kinetic energy,and the effect of droplet impact angle on the shear stress cannot be ignored.In this study,radial distribution of droplet impact angles,velocities,and shear stresses were investigated using a two-dimensional video disdrometer with three types of low-pressure sprinkler(Nelson D3000,R3000,and Komet KPT)under two operating pressures(103 and 138 kPa)and three nozzle diameters(3.97,5.95,and 7.94 mm).Furthermore,the relationships among these characteristical parameters of droplet were analyzed,and their influencing factors were comprehensively evaluated.For various types of sprinkler,operating pressures,and nozzle diameters,the smaller impact angles and larger velocities of droplets were found to occur closer to the sprinkler,resulting in relatively low droplet shear stresses.The increase in distance from the sprinkler caused the droplet impact angle to decrease and velocity to increase,which contributed to a significant increase in the shear stress that reached the peak value at the end of the jet.Therefore,the end of the jet was the most prone to soil erosion in the radial direction,and the soil erosion in sprinkler irrigation could not only be attributed to the droplet kinetic energy,but also needed to be combined with the analysis of its shear stress.Through comparing the radial distributions of average droplet shear stresses among the three types of sprinklers,D3000 exhibited the largest value(26.94-3313.51 N/m^(2)),followed by R3000(33.34-2650.80 N/m^(2)),and KPT(16.15-2485.69 N/m^(2)).From the perspective of minimizing the risk of soil erosion,KPT sprinkler was more suitable for low-pressure sprinkler irrigation than D3000 and R3000 sprinklers.In addition to selecting the appropriate sprinkler type to reduce the droplet shear stress,a suitable sprinkler spacing could also provide acceptable results,because the distance from the sprinkler exhibited a highly significant(P<0.01)effect on the shear stress.This study results provide a new reference for the design of low-pressure sprinkler irrigation system.
基金Supported by the National Science and Technology Support Project of China (Grant No.2006BAI15B08)
文摘These years Yuangong copper-bearing intrauterine devices (Cu-IUDs) have been used because of less side effects in use. The corrosion of copper is essential to the success of contraception, and the release behavior of indomethacin from medicated Cu-IUD is related to its therapeutic effect. In this study, analytical methods were established to investigate the release behavior of cupric ion of three kinds of Yuangong Cu-IUDs and indomethacin of medicated Yuangong 220 Cu-IUD. Cu-IUDs were incubated in simulated uterine solution (SUS). The concentrations of cupric ion and indomethacin were analyzed by flame atomic absorption spectrometer (FAAS) for 60 days and UV/vis ?3310 spectrophotometer for 60 days, respectively. The morphology of copper after corrosion was characterized by SEM. In addition, we detected cytotoxicity by MTT of L929 mouse fibroblasts cells caused by extracts of the three Yuangong Cu-IUDs. The release behavior of cupric ion for three kinds of Yuangong Cu-IUDs was biphasic, which consisted of the initial burst release and then slow and constant release. In vitro release experiment confirmed a biphasic release of indomethacin from Yuangong 220. The copper wire of Yuangong Cu-IUDs showed uneven corrosion. The RGR value of Yuangong 365 Cu-IUD was smaller than that of medicated Yuangong 220 Cu-IUD and RGR value of medicated Yuangong 220 Cu-IUD was smaller than that of Yuangong 300 Cu-IUD. The cupric ion release and indomethacin release showed biphasic. Indomethacin increased the cupric ion release rate and might diminish the adverse effects caused by burst release of cupric ion. The toxicity grade of these three Yuangong Cu-IUDs was 4. We should canvass the adverse events of Cu-IUDs based on practical experiments, and try our best to reduce the toxicity of Cu-IUDs.