A study on the low-cycle fatigue(LCF)behavior of K 416 B alloy was conducted at 650℃.According to the results,the LCF behavior of K 416 B alloy at 650℃ is mainly manifested as elastic deformation and the fatigue lif...A study on the low-cycle fatigue(LCF)behavior of K 416 B alloy was conducted at 650℃.According to the results,the LCF behavior of K 416 B alloy at 650℃ is mainly manifested as elastic deformation and the fatigue life of the alloy is determined by the level of material strength.When tension-compression fatigue occurs,the deformation mechanism of the alloy is reflected in the form of dislocation slip,and the deformation dislocations are bowed out in the matrix by Orowan mechanism,which leads to a dislocation configuration similar to the Frawk-Reed source.At the late stage of low-cycle fatigue,the fatigue-induced cracks develop from the alloy surface.As fatigue test proceeds,it is possible for the cracks to continue development along the regions of eutectic and the bulk M 6 C carbide due to stress concentration,thus causing the alloy to show cleavage fracture.展开更多
基金Projects(51701212,51771191,51971214)supported by the National Natural Science Foundation of ChinaProject(2019-MS-336)supported by the Liaoning Provincial Natural Science Foundation,China。
文摘A study on the low-cycle fatigue(LCF)behavior of K 416 B alloy was conducted at 650℃.According to the results,the LCF behavior of K 416 B alloy at 650℃ is mainly manifested as elastic deformation and the fatigue life of the alloy is determined by the level of material strength.When tension-compression fatigue occurs,the deformation mechanism of the alloy is reflected in the form of dislocation slip,and the deformation dislocations are bowed out in the matrix by Orowan mechanism,which leads to a dislocation configuration similar to the Frawk-Reed source.At the late stage of low-cycle fatigue,the fatigue-induced cracks develop from the alloy surface.As fatigue test proceeds,it is possible for the cracks to continue development along the regions of eutectic and the bulk M 6 C carbide due to stress concentration,thus causing the alloy to show cleavage fracture.