Production of radioactive ~9C ion beam and its optimization 被引量:3
1
作者 WEIZeng-Quan LIQiang +5 位作者 A.KITAGAWA T.KANAI M.KANAZAWA E.URAKABE XIEHong-Mei zhouguang-ming 《Nuclear Science and Techniques》 SCIE CAS CSCD 2005年第2期95-98,共4页
To explore the medical use of a radioactive 9C-ion beam in tumor treatment, which is a double radiation source coming from the external beam itself and the delayed particles emitted internally, some physical experimen... To explore the medical use of a radioactive 9C-ion beam in tumor treatment, which is a double radiation source coming from the external beam itself and the delayed particles emitted internally, some physical experiments are performed at the Secondary Beam Line (SBL) of Heavy Ion Medical Accelerator, Chiba (HIMAC) in Japan be- fore radiobiological research for exhibiting therapeutic value of the 9C beam. Intention of the experiments is for pro- ducing a radioactive 9C-ion beam with higher production rate and purity by means of optimizing the beam line pa- rameters. Finally, a produced 9C beam with the production rate of 9.07×10-6 and purity of 82.88% at full momentum acceptance has been obtained under the optimal conditions of 40 mm-thick beryllium target and 10 mm-thick alumi- num degrader. Both momentum distribution and contaminations for the produced 9C beam under the optimal condi- tions are measured. In order to execute further biological experiments of the 9C beam project, a uniform irradiation field is made with the wobbling magnets and its homogeneity is up to 93.8% inside central area of 20mm in diameter. 展开更多
关键词 放射性离子束 参数优化 肿瘤治疗 放射医学