The measurement of the rolling angle of the projectile is one of the key technologies for the terminal correction projectile.To improve the resolution accuracy of the rolling angle in the laser seeker weapon system, t...The measurement of the rolling angle of the projectile is one of the key technologies for the terminal correction projectile.To improve the resolution accuracy of the rolling angle in the laser seeker weapon system, the imaging model of the detector, calculation model of the position and the signal-to-noise ratio(SNR) model of the circuit are built to derive both the correlation between the resolution error of the rolling angle and the spot position, and the relation between the position resolution error and the SNR. Then the influence of each parameter on the SNR is analyzed at large,and the parameters of the circuit are determined. Meanwhile, the SNR and noise voltage of the circuit are calculated according to the SNR model and the decay model of the laser energy. Finally,the actual photoelectric detection circuit is built, whose SNR is measured to be up to 53 d B. It can fully meet the requirement of0.5° for the resolution error of the rolling angle, thereby realizing the analysis of critical technology for photoelectric detection of laser seeker signals.展开更多
目的评估儿童先天性小耳畸形患者自体肋软骨耳郭再造术后效果及生活质量(quality of life,QOL)。方法收集2013年7月至2020年7月昆明医科大学第二附属医院整形外科在全扩张法耳郭再造术后发放两份问卷的256例患者。第一份问卷评估再造耳...目的评估儿童先天性小耳畸形患者自体肋软骨耳郭再造术后效果及生活质量(quality of life,QOL)。方法收集2013年7月至2020年7月昆明医科大学第二附属医院整形外科在全扩张法耳郭再造术后发放两份问卷的256例患者。第一份问卷评估再造耳郭手术效果,涉及再造耳的大小、位置、颅耳角、亚单位结构等方面,总分100分,根据评分结果分为四个等级,即优、良、一般、差。第二份问卷为中文版格拉斯格儿童受益量表评分(glasgow children’s benefit inventory,GCBI),用于评价术后QOL的变化。得分为0表示QOL无变化,+100表示最大的改善,-100表示最大的恶化。并探讨再造耳手术效果和患者生活质量评分之间的关联性。结果共收回190份完整问卷,患儿手术效果评分:优69例(36.32%),良67例(35.26%),一般33例(17.37%),差21例(11.05%)。再造耳亚单位评分中,评分均值外耳轮最高(4.66分),耳屏最低(2.63分)。中文版GCBI量表得分均为正值,说明患儿术后QOL均得到不同程度的改善,其中在学习方面的改善最显著,其次是日常行为方面。相关性分析显示,再造耳手术效果与中文版GCBI总评分之间呈中等程度相关(r=0.57,P<0.01)。结论全扩张法联合自体肋软骨耳郭再造术可显著改善儿童的生活质量,并且更高质量的手术效果评分与更高的生活质量评分显著相关。展开更多
目的探讨手术切口内注入不同剂量氨甲环酸(TXA)对接受脊柱外科手术患者失血量及安全性的影响。方法选择2017年3月至2019年12月于廊坊市第四人民医院行脊柱外科矫形及多节段固定手术的108例患者为研究对象。采用随机数字表法将108例患者...目的探讨手术切口内注入不同剂量氨甲环酸(TXA)对接受脊柱外科手术患者失血量及安全性的影响。方法选择2017年3月至2019年12月于廊坊市第四人民医院行脊柱外科矫形及多节段固定手术的108例患者为研究对象。采用随机数字表法将108例患者随机分为高剂量TXA组(n=36,手术切口内注入100 mL TXA注射液),低剂量TXA组(n=36,手术切口内注入50 mL 0.9%氯化钠注射液与50 mL TXA注射液的混合液)和对照组(n=36,手术切口内注入100 mL 0.9%氯化钠注射液)。3组患者的年龄分别为(50.1±9.0)岁、(49.2±8.3)岁、(48.4±6.3)岁;男性患者分别为10、12、11例,女性分别为26、24、25例。分别收集3组患者的总失血量,术后失血量、红细胞输注量和引流量,以及术前和术后第1、2、3天时凝血功能和血栓弹力图(TEG)相关指标。于出院前1天及出院后28 d时,观察患者不良反应发生情况。3组患者的年龄、性别构成比、术前人体质量指数(BMI)及手术时间分别比较,差异均无统计学意义(F=0.16,P=0.858;χ^(2)=0.59,P=0.746;F=0.18,P=0.837;F=0.50,P=0.612)。3组患者的临床资料总体比较采用单因素方差分析,组内术后3 d总体比较采用重复方差分析,两两比较采用LSD法。本研究遵循的程序符合廊坊市第四人民医院人体试验委员会制定的标准,经过该伦理委员会批准(批准文号:LFSYLL-2016-6),并与所有患者签署临床研究知情同意书。结果①高剂量TXA组、低剂量TXA组及对照组患者的总失血量分别为(483.1±176.3)mL、(619.8±195.6)mL、(973.9±239.7)mL,术后失血量分别为(237.8±49.3)mL、(329.1±68.7)mL、(612.8±107.3)mL,术后红细胞输注量分别为(179.8±35.4)mL、(263.4±56.9)mL、(397.2±89.7)mL;3组患者总失血量、术后失血量、术后红细胞输注量分别比较,差异均有统计学意义(F=11.65、15.94、10.73,均P<0.001)。其中,高剂量TXA组患者的总失血量、术后失血量、术后红细胞输注量均最低,低剂量TXA组次之,而对照组最高(低剂量TXA组比对照组:t=10.80、16.54、11.03,均P<0.001;高剂量TXA组比对照组:t=17.24、40.31、35.79,均P<0.001;高剂量TXA组比低剂量TXA组:t=6.87、8.44、9.97,均P<0.001)。术后第1、2、3天时3组患者,以及患者术后第1、2、3天的引流量分别比较,差异均有统计学意义(3组比较:F=29.64、31.03、27.61,均P<0.001;3 d比较:F=8.79、10.86、12.68,均P<0.001)。3组患者术后1~3 d的引流量均下降,其中高剂量TXA组患者的引流量最少,低剂量TXA组次之,对照组最多,并且差异均有统计学意义(均P<0.001)。②3组患者术前凝血酶原时间(PT)、活化部分凝血活酶时间(APTT)、凝血酶时间(TT)、纤维蛋白原(Fib)水平、D-二聚体水平、反应时间(R)值、α角、最大振幅(MA)值分别比较,差异均无统计学意义(均P>0.05)。术后第1~3天时,3组患者的D-二聚体水平、MA值分别比较,差异均有统计学意义(D-二聚体水平比较:F=17.06、15.90、11.06,均P<0.001;MA值比较:F=5.32、P=0.008,F=4.88、P=0.011,F=4.90、P=0.010);其中,高剂量TXA组患者D-二聚体水平最低,MA值最高,低剂量TXA组次之,对照组D-二聚体水平最高,MA值最低,并且差异均有统计学意义(均P<0.001)。3组患者术后第1天的D-二聚体水平均最高,之后2 d逐渐下降,并且差异均有统计学意义(F=13.79、17.91、21.38,均P<0.001)。③3组患者术前t-PA、PAI-1水平分别比较,差异均无统计学意义(均P>0.05)。术后第1和3天时,3组患者的t-PA及PAI-1水平分别比较,差异均有统计学意义(t-PA水平比较:F=13.64、7.37,均P<0.001;PAI-1水平比较:F=10.30、P<0.001,F=4.65、P=0.015);其中高剂量TXA组和低剂量TXA组患者的t-PA水平均低于对照组,PAI-1水平均高于对照组,并且差异均有统计学意义(术后第1天时,t-PA水平比较:t=12.01、11.61,均P<0.001,PAI-1水平比较:t=6.73、7.52,均P<0.001;术后第3天时,t-PA水平比较:t=6.42、6.51,均P<0.001,PAI-1水平比较:t=3.42、P=0.023,t=3.51、P=0.020)。低剂量TXA组和高剂量TXA组患者术前和术后各时间点PAI-1水平分别比较,差异均无统计学意义(均P>0.05)。④所有患者出院前及出院28 d时,均未发生深静脉血栓(DVT)、肺栓塞、肾损伤、癫痫等不良事件。结论对于接受脊柱手术患者,于手术切口内注入1.0 g和0.5 g TXA的安全性均较好,并且1.0 g TXA的止血效果更佳。展开更多
基金supported by the National Natural Science Foundation of China(61201391)
文摘The measurement of the rolling angle of the projectile is one of the key technologies for the terminal correction projectile.To improve the resolution accuracy of the rolling angle in the laser seeker weapon system, the imaging model of the detector, calculation model of the position and the signal-to-noise ratio(SNR) model of the circuit are built to derive both the correlation between the resolution error of the rolling angle and the spot position, and the relation between the position resolution error and the SNR. Then the influence of each parameter on the SNR is analyzed at large,and the parameters of the circuit are determined. Meanwhile, the SNR and noise voltage of the circuit are calculated according to the SNR model and the decay model of the laser energy. Finally,the actual photoelectric detection circuit is built, whose SNR is measured to be up to 53 d B. It can fully meet the requirement of0.5° for the resolution error of the rolling angle, thereby realizing the analysis of critical technology for photoelectric detection of laser seeker signals.
文摘目的探讨手术切口内注入不同剂量氨甲环酸(TXA)对接受脊柱外科手术患者失血量及安全性的影响。方法选择2017年3月至2019年12月于廊坊市第四人民医院行脊柱外科矫形及多节段固定手术的108例患者为研究对象。采用随机数字表法将108例患者随机分为高剂量TXA组(n=36,手术切口内注入100 mL TXA注射液),低剂量TXA组(n=36,手术切口内注入50 mL 0.9%氯化钠注射液与50 mL TXA注射液的混合液)和对照组(n=36,手术切口内注入100 mL 0.9%氯化钠注射液)。3组患者的年龄分别为(50.1±9.0)岁、(49.2±8.3)岁、(48.4±6.3)岁;男性患者分别为10、12、11例,女性分别为26、24、25例。分别收集3组患者的总失血量,术后失血量、红细胞输注量和引流量,以及术前和术后第1、2、3天时凝血功能和血栓弹力图(TEG)相关指标。于出院前1天及出院后28 d时,观察患者不良反应发生情况。3组患者的年龄、性别构成比、术前人体质量指数(BMI)及手术时间分别比较,差异均无统计学意义(F=0.16,P=0.858;χ^(2)=0.59,P=0.746;F=0.18,P=0.837;F=0.50,P=0.612)。3组患者的临床资料总体比较采用单因素方差分析,组内术后3 d总体比较采用重复方差分析,两两比较采用LSD法。本研究遵循的程序符合廊坊市第四人民医院人体试验委员会制定的标准,经过该伦理委员会批准(批准文号:LFSYLL-2016-6),并与所有患者签署临床研究知情同意书。结果①高剂量TXA组、低剂量TXA组及对照组患者的总失血量分别为(483.1±176.3)mL、(619.8±195.6)mL、(973.9±239.7)mL,术后失血量分别为(237.8±49.3)mL、(329.1±68.7)mL、(612.8±107.3)mL,术后红细胞输注量分别为(179.8±35.4)mL、(263.4±56.9)mL、(397.2±89.7)mL;3组患者总失血量、术后失血量、术后红细胞输注量分别比较,差异均有统计学意义(F=11.65、15.94、10.73,均P<0.001)。其中,高剂量TXA组患者的总失血量、术后失血量、术后红细胞输注量均最低,低剂量TXA组次之,而对照组最高(低剂量TXA组比对照组:t=10.80、16.54、11.03,均P<0.001;高剂量TXA组比对照组:t=17.24、40.31、35.79,均P<0.001;高剂量TXA组比低剂量TXA组:t=6.87、8.44、9.97,均P<0.001)。术后第1、2、3天时3组患者,以及患者术后第1、2、3天的引流量分别比较,差异均有统计学意义(3组比较:F=29.64、31.03、27.61,均P<0.001;3 d比较:F=8.79、10.86、12.68,均P<0.001)。3组患者术后1~3 d的引流量均下降,其中高剂量TXA组患者的引流量最少,低剂量TXA组次之,对照组最多,并且差异均有统计学意义(均P<0.001)。②3组患者术前凝血酶原时间(PT)、活化部分凝血活酶时间(APTT)、凝血酶时间(TT)、纤维蛋白原(Fib)水平、D-二聚体水平、反应时间(R)值、α角、最大振幅(MA)值分别比较,差异均无统计学意义(均P>0.05)。术后第1~3天时,3组患者的D-二聚体水平、MA值分别比较,差异均有统计学意义(D-二聚体水平比较:F=17.06、15.90、11.06,均P<0.001;MA值比较:F=5.32、P=0.008,F=4.88、P=0.011,F=4.90、P=0.010);其中,高剂量TXA组患者D-二聚体水平最低,MA值最高,低剂量TXA组次之,对照组D-二聚体水平最高,MA值最低,并且差异均有统计学意义(均P<0.001)。3组患者术后第1天的D-二聚体水平均最高,之后2 d逐渐下降,并且差异均有统计学意义(F=13.79、17.91、21.38,均P<0.001)。③3组患者术前t-PA、PAI-1水平分别比较,差异均无统计学意义(均P>0.05)。术后第1和3天时,3组患者的t-PA及PAI-1水平分别比较,差异均有统计学意义(t-PA水平比较:F=13.64、7.37,均P<0.001;PAI-1水平比较:F=10.30、P<0.001,F=4.65、P=0.015);其中高剂量TXA组和低剂量TXA组患者的t-PA水平均低于对照组,PAI-1水平均高于对照组,并且差异均有统计学意义(术后第1天时,t-PA水平比较:t=12.01、11.61,均P<0.001,PAI-1水平比较:t=6.73、7.52,均P<0.001;术后第3天时,t-PA水平比较:t=6.42、6.51,均P<0.001,PAI-1水平比较:t=3.42、P=0.023,t=3.51、P=0.020)。低剂量TXA组和高剂量TXA组患者术前和术后各时间点PAI-1水平分别比较,差异均无统计学意义(均P>0.05)。④所有患者出院前及出院28 d时,均未发生深静脉血栓(DVT)、肺栓塞、肾损伤、癫痫等不良事件。结论对于接受脊柱手术患者,于手术切口内注入1.0 g和0.5 g TXA的安全性均较好,并且1.0 g TXA的止血效果更佳。