Based on the analytic expressions for the radiated field of a circular concave piston given by Hasegawa et al.,an integral for calculation of the radiation force on a plane absorbing target in a spherically focused fi...Based on the analytic expressions for the radiated field of a circular concave piston given by Hasegawa et al.,an integral for calculation of the radiation force on a plane absorbing target in a spherically focused field is derived.A general relation between acoustic power P and normal radiation force Fn is obtained under the condition of kr 1.Numerical computation is carried out by using the symbolic computation program for practically focused sources and absorbing circular targets.The results show that,for a given source,there is a range of target positions where the radiation force is independent of the target's position under the assumption that the contribution of the acoustic field behind the target to the radiation force can be neglected.The experiments are carried out and confirm that there is a range of target positions where the measured radiation force is basically independent of the target's position even at high acoustic power (up to 700 W).It is believed that when the radiation force method is used to measure the acoustic power radiated from a focused source,the size of the target must be selected in such a way that no observable sound can be found in the region behind the target.展开更多
Three different wall sections with step shape were applied in the finite element analysis models set up to investigate the effect on low frequency sound field by wall modification. The heights of the step in three cas...Three different wall sections with step shape were applied in the finite element analysis models set up to investigate the effect on low frequency sound field by wall modification. The heights of the step in three cases are taken as equal, random and optimized. The optimized value is obtained by using an optimization process with an objective function of minimum fluctuation in sound field. The frequency responses of rooms with original and modified walls were calculated in a range from 60 Hz to 120 Hz. The results showed that the room with an optimized wall section had the flattest frequency response. Same thing was true as the ratio of the room was changed. The largest improvement on fluctuation reached 4.5 dB, In addition, wall section with semicircle and triangle were studied. The rooms that wall section had optimized radius and heights also gave a better performance than those that had fixed radius and heights. Therefore, it is possible to use optimized wall section to improve low frequency sound field.展开更多
文摘Based on the analytic expressions for the radiated field of a circular concave piston given by Hasegawa et al.,an integral for calculation of the radiation force on a plane absorbing target in a spherically focused field is derived.A general relation between acoustic power P and normal radiation force Fn is obtained under the condition of kr 1.Numerical computation is carried out by using the symbolic computation program for practically focused sources and absorbing circular targets.The results show that,for a given source,there is a range of target positions where the radiation force is independent of the target's position under the assumption that the contribution of the acoustic field behind the target to the radiation force can be neglected.The experiments are carried out and confirm that there is a range of target positions where the measured radiation force is basically independent of the target's position even at high acoustic power (up to 700 W).It is believed that when the radiation force method is used to measure the acoustic power radiated from a focused source,the size of the target must be selected in such a way that no observable sound can be found in the region behind the target.
基金This work was supported by Excellent Youth Science Foundation of China, Grant (10105417) National Natural Science Foundation of China, Grant (10474046).
文摘Three different wall sections with step shape were applied in the finite element analysis models set up to investigate the effect on low frequency sound field by wall modification. The heights of the step in three cases are taken as equal, random and optimized. The optimized value is obtained by using an optimization process with an objective function of minimum fluctuation in sound field. The frequency responses of rooms with original and modified walls were calculated in a range from 60 Hz to 120 Hz. The results showed that the room with an optimized wall section had the flattest frequency response. Same thing was true as the ratio of the room was changed. The largest improvement on fluctuation reached 4.5 dB, In addition, wall section with semicircle and triangle were studied. The rooms that wall section had optimized radius and heights also gave a better performance than those that had fixed radius and heights. Therefore, it is possible to use optimized wall section to improve low frequency sound field.