This paper reports on the design,fabrication,RF measurement,and high-power test of a prototype accelerator—such as 11.424 GHz with 12 cells—and a traveling wave of two halves.It was found that the unloaded gradient ...This paper reports on the design,fabrication,RF measurement,and high-power test of a prototype accelerator—such as 11.424 GHz with 12 cells—and a traveling wave of two halves.It was found that the unloaded gradient reached 103 MV/m during the high-power test and the measured breakdown rate,after 3.17×10^(7) pulses,was 1.62×10^(-4)/pulse/m at 94 MV/m and a 90 ns pulse length.We thus concluded that the high-gradient two-half linear accelerator is cost-effective,especially in high-frequency RF linear acceleration.Finally,we suggest that silverbased alloy brazing can further reduce costs.展开更多
We demonstrated a novel method to measure the unloaded quality factor(Q factor) of high-Q resonant cavities. This method was used to obtain data with low errors and calculate the unloaded Q factor. This procedure was ...We demonstrated a novel method to measure the unloaded quality factor(Q factor) of high-Q resonant cavities. This method was used to obtain data with low errors and calculate the unloaded Q factor. This procedure was more reliable than traditional methods. The data required for the method were near the resonant frequency,not at the half-power points of the reflection coefficient curve or Smith chart. We applied the new method to measure a resonant cavity with an unloaded Q factor of^100,000, obtaining good agreement between the measured and theoretical results.展开更多
基金supported by the National Natural Science Foundation of China(No.11922504)。
文摘This paper reports on the design,fabrication,RF measurement,and high-power test of a prototype accelerator—such as 11.424 GHz with 12 cells—and a traveling wave of two halves.It was found that the unloaded gradient reached 103 MV/m during the high-power test and the measured breakdown rate,after 3.17×10^(7) pulses,was 1.62×10^(-4)/pulse/m at 94 MV/m and a 90 ns pulse length.We thus concluded that the high-gradient two-half linear accelerator is cost-effective,especially in high-frequency RF linear acceleration.Finally,we suggest that silverbased alloy brazing can further reduce costs.
基金supported by the National Key Research and Development Program of China(No.2016YFA0401902)
文摘We demonstrated a novel method to measure the unloaded quality factor(Q factor) of high-Q resonant cavities. This method was used to obtain data with low errors and calculate the unloaded Q factor. This procedure was more reliable than traditional methods. The data required for the method were near the resonant frequency,not at the half-power points of the reflection coefficient curve or Smith chart. We applied the new method to measure a resonant cavity with an unloaded Q factor of^100,000, obtaining good agreement between the measured and theoretical results.