The depth from extreme points(DEXP)method can be used for estimating source depths and providing a rough image as a starting model for inversion.However,the application of the DEXP method is limited by the lack of pri...The depth from extreme points(DEXP)method can be used for estimating source depths and providing a rough image as a starting model for inversion.However,the application of the DEXP method is limited by the lack of prior information regarding the structural index.Herein,we describe an automatic DEXP method derived from Euler’s Homogeneity equation,and we call it the Euler–DEXP method.We prove that its scaling field is independent of structural indices,and the scaling exponent is a constant for any potential field or its derivative.Therefore,we can simultaneously estimate source depths with diff erent geometries in one DEXP image.The implementation of the Euler–DEXP method is fully automatic.The structural index can be subsequently determined by utilizing the estimated depth.This method has been tested using synthetic cases with single and multiple sources.All estimated solutions are in accordance with theoretical source parameters.We demonstrate the practicability of the Euler–DEXP method with the gravity field data of the Hastings Salt Dome.The results ultimately represent a better understanding of the geometry and depth of the salt dome.展开更多
A method is developed for detection of polycyclic aromatic hydrocarbons(PAHs) and Phthalic Acid Esters(PAEs) in soil samples. Ultrasonic Wave Extraction under airtight circumstances is adopted to extract the analytes ...A method is developed for detection of polycyclic aromatic hydrocarbons(PAHs) and Phthalic Acid Esters(PAEs) in soil samples. Ultrasonic Wave Extraction under airtight circumstances is adopted to extract the analytes in soil samples with n-hexane–acetone(V:V=1:1) as extraction solvent. This method has several advantages, including high extraction efficiency, short time, convenience and simplicity. It can be used to detect polycyclic aromatic hydrocarbons(PAHs) and Phthalic Acid Esters(PAEs) in soil.展开更多
A method for the detection of bromate and bromide in drinking water by ion chromatography-inductively coupled plasma mass spectrometry(IC-ICP-MS) was developed. The optimized conditions of IC including p H and concent...A method for the detection of bromate and bromide in drinking water by ion chromatography-inductively coupled plasma mass spectrometry(IC-ICP-MS) was developed. The optimized conditions of IC including p H and concentration of the effluent were studied. The results showed that the above two species of bromine were baseline separated within nine minutes under the optimized conditions. The detection limits(S/N=3) of bromate and bromide were 0.23 and 0.12 μg/L, respectively. The RSD(n=6) of the peak areas was 1.2%-3.5%. The method has been successfully applied to the determination of the type bromide in drinking water samples. The recoveries were 95%-109%. The method can be used for the regular analysis of bromate and bromide in real drinking water samples.展开更多
基金supported by the National Natural Science Foundation of China (Grant No.42176186).
文摘The depth from extreme points(DEXP)method can be used for estimating source depths and providing a rough image as a starting model for inversion.However,the application of the DEXP method is limited by the lack of prior information regarding the structural index.Herein,we describe an automatic DEXP method derived from Euler’s Homogeneity equation,and we call it the Euler–DEXP method.We prove that its scaling field is independent of structural indices,and the scaling exponent is a constant for any potential field or its derivative.Therefore,we can simultaneously estimate source depths with diff erent geometries in one DEXP image.The implementation of the Euler–DEXP method is fully automatic.The structural index can be subsequently determined by utilizing the estimated depth.This method has been tested using synthetic cases with single and multiple sources.All estimated solutions are in accordance with theoretical source parameters.We demonstrate the practicability of the Euler–DEXP method with the gravity field data of the Hastings Salt Dome.The results ultimately represent a better understanding of the geometry and depth of the salt dome.
基金support from the Fundamental Research Funds for the Institute of Hydrogeology and Environmental Geology, the Chinese Academy of Geological Sciences (SK201204)
文摘A method is developed for detection of polycyclic aromatic hydrocarbons(PAHs) and Phthalic Acid Esters(PAEs) in soil samples. Ultrasonic Wave Extraction under airtight circumstances is adopted to extract the analytes in soil samples with n-hexane–acetone(V:V=1:1) as extraction solvent. This method has several advantages, including high extraction efficiency, short time, convenience and simplicity. It can be used to detect polycyclic aromatic hydrocarbons(PAHs) and Phthalic Acid Esters(PAEs) in soil.
文摘A method for the detection of bromate and bromide in drinking water by ion chromatography-inductively coupled plasma mass spectrometry(IC-ICP-MS) was developed. The optimized conditions of IC including p H and concentration of the effluent were studied. The results showed that the above two species of bromine were baseline separated within nine minutes under the optimized conditions. The detection limits(S/N=3) of bromate and bromide were 0.23 and 0.12 μg/L, respectively. The RSD(n=6) of the peak areas was 1.2%-3.5%. The method has been successfully applied to the determination of the type bromide in drinking water samples. The recoveries were 95%-109%. The method can be used for the regular analysis of bromate and bromide in real drinking water samples.