期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Research on Electric Impedance Spectroscopy of Living Cell Suspensions by a Chip with Microelectrodes 被引量:1
1
作者 Xing Yang zhaoying zhou +2 位作者 Mingfei Xiao Ying Wu Shangfeng Liu 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期429-432,共4页
A microfabricated electrical impedance spectroscopy (EIS) chip with microelectrodes was developed.The substrate and the electrodes of the chip were made of glass and gold,respectively.The experimental results demonstr... A microfabricated electrical impedance spectroscopy (EIS) chip with microelectrodes was developed.The substrate and the electrodes of the chip were made of glass and gold,respectively.The experimental results demonstrated that the EIS-chip could distinguish different solutions (physiological saline,culture medium,living cell suspension etc.) by scanning from 10Hz to 45kHz.A 6-element circuit model was used for fitting the real part and the imaginary part admittance curves of the living cell suspension.An actual circuit was also built and tested to verify the 6-element circuit model proposed.The micro-EIS chip has several advantages including the use of small sample volumes,high resolution and ease of operation.It shows good application prospects in the areas of cellular electrophysioiogy,drug screening and bio-sensors etc. 展开更多
关键词 electrical impedance spectroscopy(EIS) MICROELECTRODE living cell suspension 6-element
下载PDF
The effect of nozzle layout on droplet ejection of a piezo-electrically actuated micro-atomizer 被引量:2
2
作者 Yanying Feng zhaoying zhou +1 位作者 Junhua Zhu Guibin Du 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2007年第2期163-172,共10页
We study here effects of nozzle layout on the droplet ejection of a micro atomizer, which was fabricated with the arrayed nozzles by the MEMS technology and actuated by a piezoelectric disc. A theoretical model was fi... We study here effects of nozzle layout on the droplet ejection of a micro atomizer, which was fabricated with the arrayed nozzles by the MEMS technology and actuated by a piezoelectric disc. A theoretical model was first built for this piezoelectric-liquid-structure coupling system to characterize the acoustic wave propagation in the liquid chamber, which determined the droplet formation out of nozzles. The modal analysis was carried out numerically to predict resonant frequencies and simulate the corresponding pressure wave field. By comparing the amplitude contours of pressure wave on the liquid-solid interface at nozzle inlets with the designed nozzle layout, behaviors of the device under different vibration modes can be predicted. Experimentally, an impedance analyzer was used to measure the resonant frequencies of the system. Three types of atomizers with different nozzle layouts were fabricated for measuring the effect of nozzle distribution on the ejection performance. The visualization experiment of droplet generation was carried out and volume flow rates of these devices were measured. The good agreement between the experiment and the prediction proved that only the increase of nozzles may not enhance the droplet generation and a design of nozzle distribution from a view-point of frequency is necessary for a resonant related atomizer. 展开更多
关键词 Nozzle layout . Fluid-solid coupling . Modal analysis . Micro atomizer . MEMS
下载PDF
Application of Dynamic Linear Detecting Method in Data Processing of the Portable Blood Sugar Analyzer
3
作者 Xiaohao Wang Ran Liu +2 位作者 Fei Tang Yangchun Yu zhaoying zhou 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期80-82,共3页
In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (... In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (5%),was used for data processing and could solve the problem caused by the phenomenon of substrate depleting occurred following the redox reaction in portable blood sugar analyzer.By contrast to the conventional end-point method,the dynamic linear detecting method is based on multipoint data collecting.Experiments of measuring the calibration glucose solution with 8 various concentrations from 50 mg/dl to 400 mg/dl were carried out with the analyzer developed by our group.The linear regression curve,whose correlation for the data was 0.9995 and the residual was 2.8080,were obtained.The obtained correlation,residual, and the computation workload are all fit for the portable blood sugar analyzer. 展开更多
关键词 data processing portable blood sugar analyzer dynamic linear detecting method