期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Novel clicked tetrathiafulvalene-calix[4]arene assemblies:Synthesis and intermolecular electron transfer toward p-chloranil 被引量:3
1
作者 Bang-Tun Zhao Xiao-Min Zhu +2 位作者 Xiu-Hua Chen zhen-ning yan Wei-Min Zhu 《Chinese Chemical Letters》 SCIE CAS CSCD 2013年第7期573-577,共5页
Two tetrathiafulvalene-calix[4]arene assemblies (TTF-calix-1 and TFF-calix-2) have been synthesized by the click reaction. Both their cyclic voltammograms show, as expected, two one-electron quasi- reversible redox ... Two tetrathiafulvalene-calix[4]arene assemblies (TTF-calix-1 and TFF-calix-2) have been synthesized by the click reaction. Both their cyclic voltammograms show, as expected, two one-electron quasi- reversible redox behavior. The UV-vis absorption spectra studies show that these two assemblies undergo progressive oxidation at the TFF moiety in presence of increasing amounts of Cu2+ or Hg2+. Moreover, the absorption studies show intermolecular electron transfer between compounds TrF-calix- I or TI'F-calix-2 and p-chloranil may be promoted by specific metal ions such as Pb2+, Sc3+ etc. 展开更多
关键词 Tetrathiafulvalene arene Click reaction Chloranil lntermolecular electron transfer
原文传递
A bismuth(Ⅲ) PVC membrane ion selective electrode based on5-(3,4,5-trimethoxyphenyl)-4-amino-1,2,4-triazole-3-thiol
2
作者 Hai-Xia Wang zhen-ning yan +2 位作者 Xiang-Li Wen Yun-Xia Kang Shuang-yan Zhang 《Chinese Chemical Letters》 SCIE CAS CSCD 2015年第9期1147-1149,共3页
The construction,performance characteristics and application of a new bismuth(Ⅲ) PVC membrane electrode based on 5-(3,4,5-trimethoxyphenyl)-4-amino-1,2,4-triazole-3-thiol are reported in this paper.The designed s... The construction,performance characteristics and application of a new bismuth(Ⅲ) PVC membrane electrode based on 5-(3,4,5-trimethoxyphenyl)-4-amino-1,2,4-triazole-3-thiol are reported in this paper.The designed sensor exhibited a Nernstian response for Bi^3+ ion ranging from 5.0×10^-7 mol/L to1.0×10^-2 mol/L with a slope of 19.8 mV/decade.The operational pH range of the sensor is 3.0-6.0.The electrode shows a response time of 6 s and can be used for at least five weeks without any considerable divergence in potentials.It exhibits very good selectivity relative to a wide variety of alkali,alkaline earth,transition and heavy metal ions.The proposed electrode could be used as an indicator electrode in potentiometric titration of Bi^3+ ions with EDTA and in the determination of Bi^3+ content in stomach medicine. 展开更多
关键词 Bi^3+ PVC-membrane Ion-selective electrode Potentiometry lonophore
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部