A defect of chromatogram in a 35kV oil-immersed three-phase one-piece electric reactor in a 500kV substation。The initial analysis suggests that the defect is caused by the loose connection of the iron core magnet shi...A defect of chromatogram in a 35kV oil-immersed three-phase one-piece electric reactor in a 500kV substation。The initial analysis suggests that the defect is caused by the loose connection of the iron core magnet shield (magnet shield layer of iron core or earthling top). Examination of winding DC resistance, DGA and other relevant examinations were carried out to investigate the defect reasons., which is demonstrated by the dismantlement. In-depth study is taken and corresponding prevention measures are put forward in the paper.展开更多
Capacitor voltage transformer (CVT), which is with simple structure, convenient maintenance, functional diversity and high impact pressure strength, is widely used. And its capacitance and dielectric loss Angle measur...Capacitor voltage transformer (CVT), which is with simple structure, convenient maintenance, functional diversity and high impact pressure strength, is widely used. And its capacitance and dielectric loss Angle measurement is an important test on testing the insulation of the equipment. This paper is mainly to introduce and discuss one of the CVT test methods——the “self excitation method”, combined with the actual situation encountered in the work, sums up and expounds the maintenance of CVT and preventive test of influence factors.展开更多
文摘A defect of chromatogram in a 35kV oil-immersed three-phase one-piece electric reactor in a 500kV substation。The initial analysis suggests that the defect is caused by the loose connection of the iron core magnet shield (magnet shield layer of iron core or earthling top). Examination of winding DC resistance, DGA and other relevant examinations were carried out to investigate the defect reasons., which is demonstrated by the dismantlement. In-depth study is taken and corresponding prevention measures are put forward in the paper.
文摘Capacitor voltage transformer (CVT), which is with simple structure, convenient maintenance, functional diversity and high impact pressure strength, is widely used. And its capacitance and dielectric loss Angle measurement is an important test on testing the insulation of the equipment. This paper is mainly to introduce and discuss one of the CVT test methods——the “self excitation method”, combined with the actual situation encountered in the work, sums up and expounds the maintenance of CVT and preventive test of influence factors.