期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Treatment of a giant low-grade appendiceal mucinous neoplasm:A case report 被引量:2
1
作者 Rong Xu zhi-long yang 《World Journal of Clinical Cases》 SCIE 2021年第35期11056-11060,共5页
BACKGROUND Low-grade appendiceal mucinous neoplasm(LAMN)is extremely rare and easily misdiagnosed before surgery.CASE SUMMARY We report the treatment of an asymptomatic case of LAMN diagnosed by magnetic resonance ima... BACKGROUND Low-grade appendiceal mucinous neoplasm(LAMN)is extremely rare and easily misdiagnosed before surgery.CASE SUMMARY We report the treatment of an asymptomatic case of LAMN diagnosed by magnetic resonance imaging(MRI)and surgical findings.A 70-year-old woman presented with an adnexal mass found by physical examination in July 2020.Gynecologic ultrasonography revealed a cystic mass in the right adnexa,and computed tomography showed a cystic mass in the pelvic cavity.All tumor markers were normal.A further MRI examination suggested mucinous neoplasm in the right pelvic cavity,excluding the possibility of adnexal cyst.Laparoscopic exploration found a huge cystic mass of about 10 cm×7 cm that originated from the apex of the appendix,with spontaneous rupture.LAMN was confirmed by pathological examination.As of May 2021,no disease recurrence occurred after an open appendectomy.CONCLUSION This case indicates that we should pay more attention to female patients who are clinically diagnosed with an adnexal mass at admission,.The physical examination should be done carefully,and the laboratory and imaging examination results should be comprehensively analyzed to avoid misdiagnosis and to ensure prompt diagnosis and treatment,and to improve prognosis.MRI may be a better option for the diagnosis of appendiceal mucinous neoplasm. 展开更多
关键词 Appendiceal mucinous neoplasm Diagnosis Cystic mass Pelvic cavity APPENDECTOMY Case report
下载PDF
Influences of Resistor-Type Superconducting Fault Current Limiter on Power System Transient Stability with Asymmetrical Short-Circuit Faults 被引量:1
2
作者 Xue-Ping Gu zhi-long yang 《Journal of Electronic Science and Technology of China》 2008年第2期101-107,共7页
The transient stability of a single machine to infinite-busbar power system with resistortype superconducting fault current limiters (SFCL) is analyzed under asymmetrical short-circuit fault conditions. The SFCL is ... The transient stability of a single machine to infinite-busbar power system with resistortype superconducting fault current limiters (SFCL) is analyzed under asymmetrical short-circuit fault conditions. The SFCL is considered to introduce a resistance into the three-phase circuits when faults occur. Based on the power-angle curves for different short-circuit conditions of the single-line to ground, double-line to ground and line to line short-circuit faults, the influences of the SFCLs on transient stability are analyzed in detail. The time-domain simulation of transient stability is carried out to verify the analytical results. 展开更多
关键词 Equal-area criterion power angle curves power systems resistor-type SFCL transientstability.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部