期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
超疏水三聚氰胺海绵粉末的制备及破乳性能
1
作者 邓志鹏 赵学之 冯玉军 《高分子材料科学与工程》 EI CAS CSCD 北大核心 2023年第8期1-8,共8页
通过氯化铝溶液和甲基三氯硅烷溶液两步浸泡法制备了一种超疏水三聚氰胺海绵粉末,并对改性样品进行了扫描电镜、红外光谱和X射线光电子能谱分析。从微观结构和化学组成两方面共同揭示了粗糙度增加、硅烷化以及金属离子配位三者协同作用... 通过氯化铝溶液和甲基三氯硅烷溶液两步浸泡法制备了一种超疏水三聚氰胺海绵粉末,并对改性样品进行了扫描电镜、红外光谱和X射线光电子能谱分析。从微观结构和化学组成两方面共同揭示了粗糙度增加、硅烷化以及金属离子配位三者协同作用的超疏水转变机理。验证了压实的改性三聚氰胺粉末作为过滤材料用于“油包水”乳液高效分离的性能,讨论了润湿性、压实程度、初始含水率及粒径大小对于海绵粉末破乳性能的影响,发现适当提高材料疏水性、粉末压实程度,降低乳液初始含水率、减小粉末粒径可以有效改善其破乳效率。 展开更多
关键词 超疏水 三聚氰胺海绵粉末 油水分离 乳液
下载PDF
Numerical analysis of stress distribution in the upper arm tissues under an inflatable cuff:Implications for noninvasive blood pressure measurement 被引量:3
2
作者 zhipeng deng Fuyou Liang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2016年第5期959-969,共11页
An inflatable cuff wrapped around the upper arm is widely used in noninvasive blood pressure measurement.However, the mechanical interaction between cuff and arm tissues, a factor that potentially affects the accuracy... An inflatable cuff wrapped around the upper arm is widely used in noninvasive blood pressure measurement.However, the mechanical interaction between cuff and arm tissues, a factor that potentially affects the accuracy of noninvasive blood pressure measurement, remains rarely addressed. In the present study, finite element(FE) models were constructed to quantify intra-arm stresses generated by cuff compression, aiming to provide some theoretical evidence for identifying factors of importance for blood pressure measurement or explaining clinical observations. Obtained results showed that the simulated tissue stresses were highly sensitive to the distribution of cuff pressure on the arm surface and the contact condition between muscle and bone. In contrast, the magnitude of cuff pressure and small variations in elastic properties of arm soft tissues had little influence on the efficiency of pressure transmission in arm tissues. In particular, it was found that a thickened subcutaneous fat layer in obese subjects significantly reduced the effective pressure transmitted to the brachial artery, which may explain why blood pressure overestimation occurs more frequently in obese subjects in noninvasive blood pressure measurement. 展开更多
关键词 Noninvasive blood pressure measurement Inflatable cuff Upper arm Finite element(FE) model Loading and contact conditions Stress distribution Obese patients
下载PDF
中和站氯化钙高盐水资源化利用技术
3
作者 孙蕊 谢桂龙 +4 位作者 郭彦深 许艳梅 邓志鹏 赵伟洁 郭凯岳 《冶金设备》 2022年第S01期72-74,32,共4页
描述了年产锗锭15吨中和站水处理系统改造设计。将现有的中和站处理过的10~12%浓度氯化钙溶液进行MVR浓缩,再通过对浓缩液适当处理做成防冻液,实现氯化钙废水零排放,从而实现废水资源化利用。使目前终端氯化钙高盐水实现减量化、资源化... 描述了年产锗锭15吨中和站水处理系统改造设计。将现有的中和站处理过的10~12%浓度氯化钙溶液进行MVR浓缩,再通过对浓缩液适当处理做成防冻液,实现氯化钙废水零排放,从而实现废水资源化利用。使目前终端氯化钙高盐水实现减量化、资源化,满足生产、环保要求。 展开更多
关键词 中和站 氯化钙溶液 MVR浓缩 资源化利用
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部