Application Research of Intake-Air Cooling Technologies in Gas-Steam Combined Cycle Power Plants in China 被引量:2
1
作者 Tao Zhang zhitan liu +1 位作者 Hongliang Hao Lianchen Chang 《Journal of Power and Energy Engineering》 2014年第4期304-311,共8页
The generated power and efficiency of gas-steam combined cycle (GSCC) power plants depend on the temperature of the inlet air greatly. Based on the analysis of basic theory of inlet air cooling technologies, the appli... The generated power and efficiency of gas-steam combined cycle (GSCC) power plants depend on the temperature of the inlet air greatly. Based on the analysis of basic theory of inlet air cooling technologies, the application of evaporative cooling system and the absorption cooling system in GSCC power plants are discussed in this paper. Moreover, in China with high temperature and humidity, applied research and simulation analysis of the above two different cooling systems are conducted separately, the research results of which can provide certain reference for optimal design and economic operation of inlet air cooling system for GSCC power enterprises in China. 展开更多
关键词 Intake-Air COOLING COMBINED CYCLE Application Research
下载PDF
Improvement of part-load performance of gas turbine by adjusting compressor inlet air temperature and IGV opening 被引量:1
2
作者 Wei ZHU Xiaodong REN +5 位作者 Xuesong LI Chunwei GU zhitan liu Zhiyuan YAN Hongfei ZHU Tao ZHANG 《Frontiers in Energy》 SCIE CSCD 2022年第6期1000-1016,共17页
A novel adjusting method for improving gas turbine(GT)efficiency and surge margin(SM)under partload conditions is proposed.This method adopts the inlet air heating technology,which uses the waste heat of lowgrade heat... A novel adjusting method for improving gas turbine(GT)efficiency and surge margin(SM)under partload conditions is proposed.This method adopts the inlet air heating technology,which uses the waste heat of lowgrade heat source and the inlet guide vane(IGV)opening adjustment.Moreover,the regulation rules of the compressor inlet air temperature and the IGV opening are studied comprehensively to optimize GT performance.A model and calculation method for an equilibrium running line is adopted based on the characteristic curves of the compressor and turbine.The equilibrium running lines calculated through the calculation method involve three part-load conditions and three IGVopenings with different inlet air temperatures.The results show that there is an optimal matching relationship between IGV opening and inlet air temperature.For the best GT performance of a given load,the IGV could be adjusted according to inlet air temperature.In addition,inlet air heating has a considerable potential for the improvement of part-load performance of GT due to the increase in compressor efficiency,combustion efficiency,and turbine efficiency as well as turbine inlet temperature,when inlet air temperature is lower than the optimal value with different IGV openings.Further,when the IGV is in a full opening state and an optimal inlet air temperature is achieved by using the inlet air heating technology,GT efficiency and SM can be obviously higher than other IGVopenings.The IGV can be left unadjusted,even when the load is as low as 50%.These findings indicate that inlet air heating has a great potential to replace the IGV to regulate load because GT efficiency and SM can be remarkably improved,which is different from the traditional viewpoints. 展开更多
关键词 inlet air temperature inlet guide vane(IGV)opening part-load equilibrium running line gas turbine(GT)efficiency surge margin(SM)