Since the discovery of carbon nanotubes (CNT), this material has been recognized as an attractive catalyst support. CNT must be functionalized before use as a catalyst support and typically this involves oxidation. Ho...Since the discovery of carbon nanotubes (CNT), this material has been recognized as an attractive catalyst support. CNT must be functionalized before use as a catalyst support and typically this involves oxidation. However, the functional group distribution on the CNT is very complex mixture of groups and varies with oxidation agent used. Here a simple acid-base titration is introduced to characterize the oxygen functionalized CNT. By comparing characterization with near-edge X-ray absorption fine structure (NEXAFS) and X-ray photoelectron spectroscopy (XPS) for both at the C and O K-edges, it can be demonstrated that potentiometric proton titration can be a fast and quantitative analysis for Brnsted acid functional groups on CNT.展开更多
The establishment of the BeiDou global navigation satellite system(BDS-3)has been completed,and the current constellation can independently provide positioning service globally.BDS-3 satellites provide quad-frequency ...The establishment of the BeiDou global navigation satellite system(BDS-3)has been completed,and the current constellation can independently provide positioning service globally.BDS-3 satellites provide quad-frequency signals,which can benefit the ambiguity resolution(AR)and high-precision positioning.This paper discusses the benefits of quad-frequency observations,including the precision gain of multi-frequency high-precision positioning and the sophisticated choice of extra-wide-lane(EWL)or wide-lane(WL)combinations for instantaneous EWL/WL AR.Additionally,the performance of EWL real-time kinematic(ERTK)positioning that only uses EWL/WL combinations is investigated.The results indicate that the horizontal positioning errors of ERTK positioning using ionosphere-free(IF)EWL observations are approximately 0.5 m for the baseline of 27 km and 1 m for the baseline of 300 km.Furthermore,the positioning errors are reduced to the centimetre level if the IF EWL observations are smoothed by narrow-lane observations for a short period.展开更多
基金the DOE, Office of Basic Energy Sciences, grant DE-FG02-01ER15183 for financial support
文摘Since the discovery of carbon nanotubes (CNT), this material has been recognized as an attractive catalyst support. CNT must be functionalized before use as a catalyst support and typically this involves oxidation. However, the functional group distribution on the CNT is very complex mixture of groups and varies with oxidation agent used. Here a simple acid-base titration is introduced to characterize the oxygen functionalized CNT. By comparing characterization with near-edge X-ray absorption fine structure (NEXAFS) and X-ray photoelectron spectroscopy (XPS) for both at the C and O K-edges, it can be demonstrated that potentiometric proton titration can be a fast and quantitative analysis for Brnsted acid functional groups on CNT.
基金the National Natural Science Funds of China(41874030)The Scientific and Technological Innovation Plan from Shanghai Science and Technology Committee(18511101801)+1 种基金The National Key Research and Development Program of China(2017YFA0603102)the Fundamental Research Funds for the Central Universities.
文摘The establishment of the BeiDou global navigation satellite system(BDS-3)has been completed,and the current constellation can independently provide positioning service globally.BDS-3 satellites provide quad-frequency signals,which can benefit the ambiguity resolution(AR)and high-precision positioning.This paper discusses the benefits of quad-frequency observations,including the precision gain of multi-frequency high-precision positioning and the sophisticated choice of extra-wide-lane(EWL)or wide-lane(WL)combinations for instantaneous EWL/WL AR.Additionally,the performance of EWL real-time kinematic(ERTK)positioning that only uses EWL/WL combinations is investigated.The results indicate that the horizontal positioning errors of ERTK positioning using ionosphere-free(IF)EWL observations are approximately 0.5 m for the baseline of 27 km and 1 m for the baseline of 300 km.Furthermore,the positioning errors are reduced to the centimetre level if the IF EWL observations are smoothed by narrow-lane observations for a short period.