It is difficult to determine the discharge stages in a fixed time of repetitive discharge underwater due to the arc formation process being susceptible to external environmental influences. This paper proposes a novel...It is difficult to determine the discharge stages in a fixed time of repetitive discharge underwater due to the arc formation process being susceptible to external environmental influences. This paper proposes a novel underwater discharge stage identification method based on the Strong Tracking Filter(STF) and impedance change characteristics. The time-varying equivalent circuit model of the discharge underwater is established based on the plasma theory analysis of the impedance change characteristics and mechanism of the discharge process. The STF is used to reduce the randomness of the impedance of repeated discharges underwater, and then the universal identification resistance data is obtained. Based on the resistance variation characteristics of the discriminating resistance of the pre-breakdown, main, and oscillatory discharge stages, the threshold values for determining the discharge stage are obtained. These include the threshold values for the resistance variation rate(K) and the moment(t).Experimental and error analysis results demonstrate the efficacy of this innovative method in discharge stage determination, with a maximum mean square deviation of Scrless than 1.761.展开更多
Based on the background of achieving carbon peaking and carbon neutrality, the development and application of new high-power compressors, electric grid drilling RIGS and electric fracturing pump system provide new equ...Based on the background of achieving carbon peaking and carbon neutrality, the development and application of new high-power compressors, electric grid drilling RIGS and electric fracturing pump system provide new equipment support for the electric, green and intelligent development of shale gas fields in China. However, the harmonic pollution of shale gas grid becomes more serious due to the converter and frequency conversion device in the system, which easily causes harmonic resonance problem. Therefore, the harmonic resonance of shale gas grid is comprehensively analyzed and treated. Firstly, the working mechanism of compressor, electric drilling RIGS of the harmonic impedance model of electric fracturing pump system is established. Secondly, the main research methods of harmonic resonance analysis are introduced, and the basic principle of modal analysis is explained. Modal analysis method was used to analyze. Finally, harmonic resonance is suppressed. The results show that there may be multiple resonant frequency points in the distribution network changes, but these changes are relatively clear;if the original resonant frequency point of the resonant loop does not exist, the resonant frequency point disappears. The optimal configuration strategy of passive filter can effectively suppress harmonic resonance of distribution network in shale gas field.展开更多
基金provided by the shale gas resource evaluation methods and exploration technology research project of the National Science and Technology Major Project of China(No.2016ZX05034)Graduate Innovative Engineering Funding Project of China University of Petroleum(East China)(No.YCX2021109)。
文摘It is difficult to determine the discharge stages in a fixed time of repetitive discharge underwater due to the arc formation process being susceptible to external environmental influences. This paper proposes a novel underwater discharge stage identification method based on the Strong Tracking Filter(STF) and impedance change characteristics. The time-varying equivalent circuit model of the discharge underwater is established based on the plasma theory analysis of the impedance change characteristics and mechanism of the discharge process. The STF is used to reduce the randomness of the impedance of repeated discharges underwater, and then the universal identification resistance data is obtained. Based on the resistance variation characteristics of the discriminating resistance of the pre-breakdown, main, and oscillatory discharge stages, the threshold values for determining the discharge stage are obtained. These include the threshold values for the resistance variation rate(K) and the moment(t).Experimental and error analysis results demonstrate the efficacy of this innovative method in discharge stage determination, with a maximum mean square deviation of Scrless than 1.761.
文摘Based on the background of achieving carbon peaking and carbon neutrality, the development and application of new high-power compressors, electric grid drilling RIGS and electric fracturing pump system provide new equipment support for the electric, green and intelligent development of shale gas fields in China. However, the harmonic pollution of shale gas grid becomes more serious due to the converter and frequency conversion device in the system, which easily causes harmonic resonance problem. Therefore, the harmonic resonance of shale gas grid is comprehensively analyzed and treated. Firstly, the working mechanism of compressor, electric drilling RIGS of the harmonic impedance model of electric fracturing pump system is established. Secondly, the main research methods of harmonic resonance analysis are introduced, and the basic principle of modal analysis is explained. Modal analysis method was used to analyze. Finally, harmonic resonance is suppressed. The results show that there may be multiple resonant frequency points in the distribution network changes, but these changes are relatively clear;if the original resonant frequency point of the resonant loop does not exist, the resonant frequency point disappears. The optimal configuration strategy of passive filter can effectively suppress harmonic resonance of distribution network in shale gas field.