Development of Enzyme Biosensor for Amperometric Measurement of Aspartate Aminotransferase
1
作者 zonghui guo Chunxiu Liu +3 位作者 Huaqing Li Jianfang Xu Lianshi Feng Xinxia Cai 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期330-332,共3页
An enzyme biosensor for amperometric measurement of aspartate aminotransferase has been developed.The working electrode was modified with a thin-film of redox polymer,then glutamate oxidase,with the immobilized reagen... An enzyme biosensor for amperometric measurement of aspartate aminotransferase has been developed.The working electrode was modified with a thin-film of redox polymer,then glutamate oxidase,with the immobilized reagent cast and dried on the electrode.The biosensor responses to AST by detecting hydrogen peroxide were produced by enzymical reaction at-0.1 V with a response time of 120 seconds.The electrode gave a detection limit of 32.5 U/L with a linear concentration range of 32.5 U/L~2000 U/L in serum.Due to more sensitive and lower detection limit,the biosensor is expected mainly to be used for physiological identification and physical performance of athletes in the future.Extended application will also affect the practice of clinical medicine for the diagnosis of heart and liver disease. 展开更多
关键词 aspartate aminotransferase redox polymer AMPEROMETRIC BIOSENSOR
下载PDF
Amperometric Enzyme Biosensor for the Determination of High Concentration Lactate in Whole Blood of Athletes
2
作者 Chunxiu Liu zonghui guo +3 位作者 Hui Wang Jianfang Xu Lianshi Feng Xinxia Cai 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期83-86,共4页
<正>Amperometric biosensor applied to the determination of high concentration lactate in serum and whole blood was described.The biosensor was constructed by gold electrode modified with nanoplatinum particles.L... <正>Amperometric biosensor applied to the determination of high concentration lactate in serum and whole blood was described.The biosensor was constructed by gold electrode modified with nanoplatinum particles.Lactate oxidase (E.C.1.1.3.2) was immobilized at platinized activated gold electrode which was used for the determination of high concentration lactate at low potential (+0.2 V).The linear calibration graphs were obtained from 1 to 21 mmol·L~ (-1) lactate in serum and from 0.9 to 13.2 mmol.L~ (-1) lactate in whole blood.The correlation coefficients were 0.99 and 0.97,respectively at a steady-state response time of 50 s. 展开更多
关键词 biosensors lactate oxidase high concentration lactate whole blood
下载PDF
A Point-of-Care Test System for Biochemical Blood Analysis Based on ADUC824
3
作者 Hui Wang Qing Tian +3 位作者 Liying Jiang Chunxiu Liu zonghui guo Xinxia Cai 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期75-79,共5页
A point-of-care test system has been studied in this paper.It was used to determine substances in blood such as Hemoglobin (HB),Aspartate Aminotransferase (AST),Creatine Kinase (CK) and so on.Based on the principle ... A point-of-care test system has been studied in this paper.It was used to determine substances in blood such as Hemoglobin (HB),Aspartate Aminotransferase (AST),Creatine Kinase (CK) and so on.Based on the principle of amperometric determination,the research on detecting weak current signals was carried on.At the same time as to the weak signals (nA level),magnifying,sampling and processing the signals were also studied.Controlled by ADUC824 and assisted by other units, every substance could be determined automatically and rapidly integrated with the corresponding biosensor.In the experiment, the minimum detectable current of the instrument (YT2005-1) is 0.2 nA.With regard to the 1 nA which the experiment demanded,it could be up to the mustard.And the system can provide results in 180 s with a long term stability. 展开更多
关键词 point-of-care test ADUC824 weak signals HB AST and CK
下载PDF