Background Low responsiveness to clopidogrel (LRC) is associated with increased risk of ischemic events. This study was aimed to explore the feasibility of tailored antiplatelet therapy according to the responsivene...Background Low responsiveness to clopidogrel (LRC) is associated with increased risk of ischemic events. This study was aimed to explore the feasibility of tailored antiplatelet therapy according to the responsiveness to clopidogrel. Methods A total of 305 clopidogrel naive patients with acute coronary syndromes (ACS) undergoing coronary stenting were randomly assigned to receive standard (n = 151) or tailored (n = 154) antiplatelet therapy. The ADP-induced platelet aggregation tests by light transmission aggregometry were performed to identify LRC patients assigned to the tailored group. The standard antiplatelet regimen was dual antiplatelet therapy with aspirin and clopidogrel. The tailored antiplatelet therapy was standard regimen for non-LRC patients and an additional 6-month cilostazol treatment for LRC patients. The primary efficacy outcome was the composite of cardiovascular death, myocardial infarction or stroke at one year. Results LCR was present in 26.6% (41/154) of patients in the tailored group. The percentage platelet aggregation for LCR patients was significantly decreased at three days after adjunctive cilostazol treatment (77.5% ± 12.1% vs. 64.5% ± 12.1%, P 〈 0.001). At one year follow-up, a non-significant 37% relative risk reduction of primary events were observed in the tailored group as compared to the standard group (5.8% vs. 9.3%, P = 0.257). There were no differences in the rates of stent thrombosis and hemorrhagic events between the two groups. Conclusions Tailored antiplatelet therapy for ACS patients after coronary stenting according to responsiveness to clopidogrel is feasible. However, its efficacy and safety need further confirmation by clinical trials with larger sample sizes.展开更多
Cryoballoon ablation has been widely used in the treatment of atrial fibrillation (AF).[1] The main complications of the procedure include pericardial tamponade, pulmonary vein stenosis, and atrial esophageal leakage,...Cryoballoon ablation has been widely used in the treatment of atrial fibrillation (AF).[1] The main complications of the procedure include pericardial tamponade, pulmonary vein stenosis, and atrial esophageal leakage, etc.[2] But there has been hardly any reporting of PR-segment changes caused by cryoballoon ablation of AF.展开更多
Objective:There is no simple or feasible post-procedural intravascular ultrasound (IVUS) score to predict major adverse cardiac events (MACE) in patients undergoing drug-eluting stents (DES) implantation. The aim of t...Objective:There is no simple or feasible post-procedural intravascular ultrasound (IVUS) score to predict major adverse cardiac events (MACE) in patients undergoing drug-eluting stents (DES) implantation. The aim of this study is to validate a new IVUS score for predicting MACE. Methods:A total of 295 patients (with 322 lesions) were enrolled. IVUS score was calculated in each lesion based on five IVUS morphological characteristics:inflow/outflow disease, malapposition, underexpansion, tissue protrusion, and edge dissection (iMUTE score). We assigned two points to an underexpansion and one point for each presence of other factors. Patients were divided into low score (iMUTE score<2, n=137) and high score (iMUTE score≥2, n=158) groups. Results:At one year follow-up, a trend was seen in favor of the low iMUTE score group in MACE (3.65% vs. 10.10%; P=0.052), and there was more target vessel revascularization (TVR) in the high iMUTE score group compared with low score group (6.96% vs. 1.46%; P=0.044). Low iMUTE score was an independent predictor of freedom from TVR at one year (adjusted hazard ratio (HR) 0.5, 95% confidence interval (CI) 0.1-0.8; P=0.02). Conclusions:Post-procedural IVUS iMUTE scoring was simple and feasible in clinical practice, and can provide independent prognostic value for TVR in patients undergoing DES implantation.展开更多
文摘Background Low responsiveness to clopidogrel (LRC) is associated with increased risk of ischemic events. This study was aimed to explore the feasibility of tailored antiplatelet therapy according to the responsiveness to clopidogrel. Methods A total of 305 clopidogrel naive patients with acute coronary syndromes (ACS) undergoing coronary stenting were randomly assigned to receive standard (n = 151) or tailored (n = 154) antiplatelet therapy. The ADP-induced platelet aggregation tests by light transmission aggregometry were performed to identify LRC patients assigned to the tailored group. The standard antiplatelet regimen was dual antiplatelet therapy with aspirin and clopidogrel. The tailored antiplatelet therapy was standard regimen for non-LRC patients and an additional 6-month cilostazol treatment for LRC patients. The primary efficacy outcome was the composite of cardiovascular death, myocardial infarction or stroke at one year. Results LCR was present in 26.6% (41/154) of patients in the tailored group. The percentage platelet aggregation for LCR patients was significantly decreased at three days after adjunctive cilostazol treatment (77.5% ± 12.1% vs. 64.5% ± 12.1%, P 〈 0.001). At one year follow-up, a non-significant 37% relative risk reduction of primary events were observed in the tailored group as compared to the standard group (5.8% vs. 9.3%, P = 0.257). There were no differences in the rates of stent thrombosis and hemorrhagic events between the two groups. Conclusions Tailored antiplatelet therapy for ACS patients after coronary stenting according to responsiveness to clopidogrel is feasible. However, its efficacy and safety need further confirmation by clinical trials with larger sample sizes.
基金supported by National Key Project of Research and Development Plan during the Thirteenth Five-year Plan Period of China (2016YFC0900900 & 2016YFC1301300 & 2017YFC1307800)
文摘Cryoballoon ablation has been widely used in the treatment of atrial fibrillation (AF).[1] The main complications of the procedure include pericardial tamponade, pulmonary vein stenosis, and atrial esophageal leakage, etc.[2] But there has been hardly any reporting of PR-segment changes caused by cryoballoon ablation of AF.
基金supported by the Key Project of the National 12th Five-Year Research Program of China (No. 2012ZX09303016-002)the PhD Initiative Research Grant (No. 20091100) of Liaoning Province, China
文摘Objective:There is no simple or feasible post-procedural intravascular ultrasound (IVUS) score to predict major adverse cardiac events (MACE) in patients undergoing drug-eluting stents (DES) implantation. The aim of this study is to validate a new IVUS score for predicting MACE. Methods:A total of 295 patients (with 322 lesions) were enrolled. IVUS score was calculated in each lesion based on five IVUS morphological characteristics:inflow/outflow disease, malapposition, underexpansion, tissue protrusion, and edge dissection (iMUTE score). We assigned two points to an underexpansion and one point for each presence of other factors. Patients were divided into low score (iMUTE score<2, n=137) and high score (iMUTE score≥2, n=158) groups. Results:At one year follow-up, a trend was seen in favor of the low iMUTE score group in MACE (3.65% vs. 10.10%; P=0.052), and there was more target vessel revascularization (TVR) in the high iMUTE score group compared with low score group (6.96% vs. 1.46%; P=0.044). Low iMUTE score was an independent predictor of freedom from TVR at one year (adjusted hazard ratio (HR) 0.5, 95% confidence interval (CI) 0.1-0.8; P=0.02). Conclusions:Post-procedural IVUS iMUTE scoring was simple and feasible in clinical practice, and can provide independent prognostic value for TVR in patients undergoing DES implantation.