In cases of severe segmental injury across the hand and wrist, but one or other fingers are still in peak condition, the fingers can be selected for replantation at the forearm bones to restore pinch function. Here we...In cases of severe segmental injury across the hand and wrist, but one or other fingers are still in peak condition, the fingers can be selected for replantation at the forearm bones to restore pinch function. Here we reported an unusual case with a severe crush-avulsion amputated injury to the right hand caused by a machine accident. We conducted hand reconstruction using heterotopic replantation of the amputated index and little fingers.During 19 months follow-up, the bone union healed well with satisfactory outcome. The interphalangeal and metacarpophalangeal joint of the fingers after the heterotopic replantation had a good holding activity. This is a worthwhile procedure and the patient is satisfied with the result. The major disadvantage of this method is the poor appearance of the reconstructed fingers.展开更多
Missed or neglected foreign bodies are not infrequent in surgical practice. This case report high- lights the fact that thorough clinical examination and de- tailed evaluation of trauma patients are very necessary so ...Missed or neglected foreign bodies are not infrequent in surgical practice. This case report high- lights the fact that thorough clinical examination and de- tailed evaluation of trauma patients are very necessary so that any associated injuries or foreign bodies will not be missed and any unforeseen clinical or medico-legal complications can be prevented. We present a case of a 35-year- old male patient who had traumatic transfemoral amputation of the right lower limb with a clean laceration (size 2 cmx I cm) over the medial aspect of the left thigh. Radiographs suggested a single radioopaque foreign body which proved misleading, as during surgical removal multiple radiolucent and radiopaque foreign bodies were discovered.Postoperative ultrasound was performed and showed no retained foreign bodies. A secondary closure of the right thigh amputation was done and patient was discharged. At the last follow-up, 9 months after injury, the patient had no complaints, and both the amputation stump and the wound over the left thigh were healthy. Thus in the cases of re- tained foreign bodies, in addition to thorough clinical examination and radiography, ultrasonograpy should be supplemented. And if required, use of CT scan as well as MRI should be also considered.展开更多
文摘In cases of severe segmental injury across the hand and wrist, but one or other fingers are still in peak condition, the fingers can be selected for replantation at the forearm bones to restore pinch function. Here we reported an unusual case with a severe crush-avulsion amputated injury to the right hand caused by a machine accident. We conducted hand reconstruction using heterotopic replantation of the amputated index and little fingers.During 19 months follow-up, the bone union healed well with satisfactory outcome. The interphalangeal and metacarpophalangeal joint of the fingers after the heterotopic replantation had a good holding activity. This is a worthwhile procedure and the patient is satisfied with the result. The major disadvantage of this method is the poor appearance of the reconstructed fingers.
文摘Missed or neglected foreign bodies are not infrequent in surgical practice. This case report high- lights the fact that thorough clinical examination and de- tailed evaluation of trauma patients are very necessary so that any associated injuries or foreign bodies will not be missed and any unforeseen clinical or medico-legal complications can be prevented. We present a case of a 35-year- old male patient who had traumatic transfemoral amputation of the right lower limb with a clean laceration (size 2 cmx I cm) over the medial aspect of the left thigh. Radiographs suggested a single radioopaque foreign body which proved misleading, as during surgical removal multiple radiolucent and radiopaque foreign bodies were discovered.Postoperative ultrasound was performed and showed no retained foreign bodies. A secondary closure of the right thigh amputation was done and patient was discharged. At the last follow-up, 9 months after injury, the patient had no complaints, and both the amputation stump and the wound over the left thigh were healthy. Thus in the cases of re- tained foreign bodies, in addition to thorough clinical examination and radiography, ultrasonograpy should be supplemented. And if required, use of CT scan as well as MRI should be also considered.