This paper analyzed the results of multiple testing of the E202A,B Heat Exchanger whose running time has exceeded the time limit,and calculated the strength of the shell,seal fitting and tube plate.On the basis of the...This paper analyzed the results of multiple testing of the E202A,B Heat Exchanger whose running time has exceeded the time limit,and calculated the strength of the shell,seal fitting and tube plate.On the basis of these,the remaining lifespan of the E202A,B Heat Exchanger was assessed at three years.展开更多
文摘This paper analyzed the results of multiple testing of the E202A,B Heat Exchanger whose running time has exceeded the time limit,and calculated the strength of the shell,seal fitting and tube plate.On the basis of these,the remaining lifespan of the E202A,B Heat Exchanger was assessed at three years.