In order to detect the refractive index of liquid with high precision,based on modular interference,Mach-Zehnder optical fiber refractive rate sensor was studied.Sensor structure is composed of ordinary single-mode fi...In order to detect the refractive index of liquid with high precision,based on modular interference,Mach-Zehnder optical fiber refractive rate sensor was studied.Sensor structure is composed of ordinary single-mode fiber and multimode fiber,according to the singlemode multimode singlemode sequence to fuse together,and the fused optical fiber is used to process the taper.As a result,the diameter of the sensing head is about 10μm.Experimental results show that,as liquid refractive index increases range from 1.33 to 1.35,the loss peak of the transmission spectrum will shift to long wave direction.展开更多
随着汽车行业的不断发展和智能化进程的加速,AUTOSAR已成为一种广泛采用的汽车软件架构标准,ARXML(AUTOSAR结构化文档)是该架构标准中描述车辆电子控制单元(electronic control unit,ECU)的重要资源。针对大量数据密度高且内容复杂的AR...随着汽车行业的不断发展和智能化进程的加速,AUTOSAR已成为一种广泛采用的汽车软件架构标准,ARXML(AUTOSAR结构化文档)是该架构标准中描述车辆电子控制单元(electronic control unit,ECU)的重要资源。针对大量数据密度高且内容复杂的ARXML文档查询处理效率的问题,提出了一种基于动态融合索引树的结构化文档查询处理算法。算法从节点关系规则出发,对单个文档中的内部节点和不同文档中节点之间的关系规则进行分析,在保留节点原始关系的同时构建了带有外部关系的节点关系结构,并基于结构化文档查询表达式对该结构进行改进,最后将其扩展成动态融合索引树结构,降低文档解析处理时间消耗,提高查询性能。复杂性分析和实验结果表明,使用动态融合索引树结构的文档查询效率高于现有的查询方法,具备一定的实用性。展开更多
目的评估基于磁共振成像(MRI)的腰肌质量参数对腰椎后路椎间融合术(PLIF)后融合器下沉的预测价值。方法对2019年2月至2023年2月接受单节段PLIF的165例病人进行回顾性研究,男75例,女90例,年龄为(65.02±8.55)岁。随访12个月以上,45例...目的评估基于磁共振成像(MRI)的腰肌质量参数对腰椎后路椎间融合术(PLIF)后融合器下沉的预测价值。方法对2019年2月至2023年2月接受单节段PLIF的165例病人进行回顾性研究,男75例,女90例,年龄为(65.02±8.55)岁。随访12个月以上,45例(27.3%)发生融合器沉降,根据是否发生术后融合器沉降分为沉降组(45例)与非沉降组(120例)。术前在MRI上测量腰肌指数(PMI)和腰肌质量评分(Goutallier分级),以及椎体骨质量(vertebral bone quality,VBQ)、终板骨质量(endplate bone quality,EBQ);基于CT,测量计算机断层扫描(QCT)骨密度值。比较两组病人的年龄、性别、身体质量指数(BMI)、手术节段、PMI、Goutallier分级等;采用Logistic回归分析融合器下沉的影响因素;PMI、Goutallier分级分别与融合器沉降高度、QCT骨密度值进行相关性分析;比较不同手术节段中的PMI、Goutallier分级;绘制受试者工作特征曲线(ROC),计算各预测因子的曲线下面积(AUC)。结果沉降组与非沉降组的年龄、性别、BMI、Goutallier分级、PMI、VBQ、EBQ比较,差异有统计学意义(P<0.05)。Logistic回归分析结果显示年龄、性别、QCT骨密度值、VBQ、PMI、Goutallier分级是融合器沉降的影响因素。相关性分析结果显示PMI与融合器沉降高度呈显著负相关(r=-0.402,P<0.05),与QCT骨密度值呈显著正相关(r=3.390,P<0.05);Goutallier分级与融合器沉降高度呈正相关(r=0.289,P<0.05),与QCT骨密度值呈负相关(r=-0.286,P<0.05),与PMI呈负相关(r=-0.462,P<0.05)。PMI的AUC为0.826(95%CI:0.756,0.896),最佳沉降边界为6.94 cm^(2)/m^(2),Goutallier分级的AUC为0.786(95%CI:0.719,0.854),最佳沉降边界1.5级。结论PMI和Goutallier分级可能是PLIF术后融合器沉降的重要预测指标。展开更多
基金National Natural Science Foundation of China(No.61405127)Shanxi Province Science Foundation for Youths(No.2014021023-1)+1 种基金Scientific and Technologial Innovation Programs of Higher Education Institutions in Shanxi ProvinceProgram for Top Young Academic Leaders of Higher Learning Institutions in Shanxi Province
文摘In order to detect the refractive index of liquid with high precision,based on modular interference,Mach-Zehnder optical fiber refractive rate sensor was studied.Sensor structure is composed of ordinary single-mode fiber and multimode fiber,according to the singlemode multimode singlemode sequence to fuse together,and the fused optical fiber is used to process the taper.As a result,the diameter of the sensing head is about 10μm.Experimental results show that,as liquid refractive index increases range from 1.33 to 1.35,the loss peak of the transmission spectrum will shift to long wave direction.
文摘随着汽车行业的不断发展和智能化进程的加速,AUTOSAR已成为一种广泛采用的汽车软件架构标准,ARXML(AUTOSAR结构化文档)是该架构标准中描述车辆电子控制单元(electronic control unit,ECU)的重要资源。针对大量数据密度高且内容复杂的ARXML文档查询处理效率的问题,提出了一种基于动态融合索引树的结构化文档查询处理算法。算法从节点关系规则出发,对单个文档中的内部节点和不同文档中节点之间的关系规则进行分析,在保留节点原始关系的同时构建了带有外部关系的节点关系结构,并基于结构化文档查询表达式对该结构进行改进,最后将其扩展成动态融合索引树结构,降低文档解析处理时间消耗,提高查询性能。复杂性分析和实验结果表明,使用动态融合索引树结构的文档查询效率高于现有的查询方法,具备一定的实用性。
文摘目的评估基于磁共振成像(MRI)的腰肌质量参数对腰椎后路椎间融合术(PLIF)后融合器下沉的预测价值。方法对2019年2月至2023年2月接受单节段PLIF的165例病人进行回顾性研究,男75例,女90例,年龄为(65.02±8.55)岁。随访12个月以上,45例(27.3%)发生融合器沉降,根据是否发生术后融合器沉降分为沉降组(45例)与非沉降组(120例)。术前在MRI上测量腰肌指数(PMI)和腰肌质量评分(Goutallier分级),以及椎体骨质量(vertebral bone quality,VBQ)、终板骨质量(endplate bone quality,EBQ);基于CT,测量计算机断层扫描(QCT)骨密度值。比较两组病人的年龄、性别、身体质量指数(BMI)、手术节段、PMI、Goutallier分级等;采用Logistic回归分析融合器下沉的影响因素;PMI、Goutallier分级分别与融合器沉降高度、QCT骨密度值进行相关性分析;比较不同手术节段中的PMI、Goutallier分级;绘制受试者工作特征曲线(ROC),计算各预测因子的曲线下面积(AUC)。结果沉降组与非沉降组的年龄、性别、BMI、Goutallier分级、PMI、VBQ、EBQ比较,差异有统计学意义(P<0.05)。Logistic回归分析结果显示年龄、性别、QCT骨密度值、VBQ、PMI、Goutallier分级是融合器沉降的影响因素。相关性分析结果显示PMI与融合器沉降高度呈显著负相关(r=-0.402,P<0.05),与QCT骨密度值呈显著正相关(r=3.390,P<0.05);Goutallier分级与融合器沉降高度呈正相关(r=0.289,P<0.05),与QCT骨密度值呈负相关(r=-0.286,P<0.05),与PMI呈负相关(r=-0.462,P<0.05)。PMI的AUC为0.826(95%CI:0.756,0.896),最佳沉降边界为6.94 cm^(2)/m^(2),Goutallier分级的AUC为0.786(95%CI:0.719,0.854),最佳沉降边界1.5级。结论PMI和Goutallier分级可能是PLIF术后融合器沉降的重要预测指标。