期刊文献+
共找到27,846篇文章
< 1 2 250 >
每页显示 20 50 100
Radiation Doses in Diagnostic Radiology and Method for Dose Reduction
1
作者 Taha M. Taha Hoda A. Ahmed Fathy A. Shaheen 《Open Journal of Radiology》 2023年第1期34-41,共8页
Objective: The current research study aims to calculate entrance surface air kerma for skull, chest, cervical spine, lumbar spine, and pelvic X-ray examinations in interior posterior and posterior interior positions a... Objective: The current research study aims to calculate entrance surface air kerma for skull, chest, cervical spine, lumbar spine, and pelvic X-ray examinations in interior posterior and posterior interior positions and generate a method for chest dose reduction to decrease radiation risk. Materials and Methods: The indirect dose measurement was used in the current research. The X-ray tube output was measured using RAD-CHECK Plus ionization chamber and the indirect entrance surface air kerma was calculated via applying physical acquisition parameters such as a focus on skin distance, tube current times exposure time (mAs), and applied tube voltage (kV), and applying a mathematical model. Results: The main findings were obtained from comparing the radiation doses with the reference levels of International organizations such as the American College of Radiology and the International Atomic Energy Authority. The mean entrance skin dose for the skull (AP), skull (PA), skull (LAT), cervical spine (PA), cervical spine (LAT), lumbar spine (AP), lumbar spine (LAT), pelvis (AP), and pelvis (LAT) of adult X-ray examinations was within the diagnostic reference dose level values obtained by ACR (2018) except for the ESD for chest (AP) which was 0.88 mGy. Conclusions: The results of the study concluded that by adjusting the applied tube voltage, kV, and tube current product time, mAs decreased the radiation dose to the chest X-ray by 58%. 展开更多
关键词 RADIOLOGY Entrance Skin dose Chest X-Ray dose Minimization
下载PDF
Effects of different doses of long-acting growth hormone in treating children with growth hormone deficiency
2
作者 Wei Xia Ting Wang Jia-Yan Pan 《World Journal of Clinical Cases》 SCIE 2023年第28期6715-6724,共10页
BACKGROUND With the improvement of economy and living standards,the attention paid to short stature in children has been increasingly highlighted.Numerous causes can lead to short stature in children,among which growt... BACKGROUND With the improvement of economy and living standards,the attention paid to short stature in children has been increasingly highlighted.Numerous causes can lead to short stature in children,among which growth hormone deficiency(GHD)is a significant factor.AIM To investigate the long-term efficacy and safety of different doses of long-acting polyethylene glycol recombinant human growth hormone(PEG-rhGH)in the treatment of GHD in children.METHODS We selected 44 pediatric patients diagnosed with GHD who were treated at Wuhu First People's Hospital from 2014 to 2018.Total 23 patients were administered a high dose of long-acting PEG-rhGH at 0.2 mg/kg subcutaneously each week,forming the high-dose group.Meanwhile,21 patients were given a lower dose of long-acting PEG-rhGH at 0.14 mg/kg subcutaneously each week,establishing the low-dose Group.The total treatment period was 2 years,during which we monitored the patients’height,annual growth velocity(GV),height standard deviation score(HtSDS),chronological age(CA),bone age(BA),and serum levels of insulin-like growth factor-1(IGF-1)and insulin-like growth factor-binding protein-3(IGFBP-3)before treatment and at 6 mo,1 year,and 2 years after treatment initiation.We also monitored thyroid function,fasting plasma glucose,fasting insulin,and other side effects.Furthermore,we calculated the homeostatic model assessment for insulin resistance.RESULTS After 1 year of treatment,the GV,HtSDS,IGF-1,BA,and IGFBP-3 in both groups significantly improved compared to the pre-treatment levels(P<0.05).Moreover,when comparing GV,HtSDS,IGF-1,BA,and IGFBP-3 between the two groups,there were no statistically significant differences either before or after the treatment(P>0.05).During the treatment intervals of 0-1.0 years and 1.0-2.0 years,both patient groups experienced a slowdown in GV and a decline in HtSDS improvement(P<0.05).CONCLUSION The use of PEG-rhGH in treating GHD patients was confirmed to be effective,with similar outcomes observed in both the high-dose group and low-dose groups,and no significant differences in the main side effects. 展开更多
关键词 CHILDREN Growth hormone deficiency Polyethylene glycol recombinant human growth hormone Different doses Bone age
下载PDF
Effectiveness of COVID-19 Vaccine Doses in Children: Case of Lake Region Economic Bloc-Kenya
3
作者 Shem Otoi Sam Naomy Onyuka +1 位作者 Michael Audi Khama Rogo 《Open Journal of Modelling and Simulation》 2023年第3期88-97,共10页
Introduction: Vaccination of children has experienced delays due to paucity of information regarding safety, effectiveness, immunogenicity, and reactogenicity. Age wise approval prioritized 12 - 17 years and later 5 -... Introduction: Vaccination of children has experienced delays due to paucity of information regarding safety, effectiveness, immunogenicity, and reactogenicity. Age wise approval prioritized 12 - 17 years and later 5 - 11 years. Those below 5 years possess na?ve immunity and not considered. In Lake Region Economic Bloc children aged 12 - 17 variably received 1, 2, and 3 doses of vaccine. This analysis looks into effectiveness of the doses administered. Method: Data providers from 84 LREB facilities submitted patients’ vaccination data to Power BI supported dashboard between June 24, 2021 and July 30, 2022. Data of 12 - 17 years old was mined, analyzed and visualized. Sample sizes considered for analysis were 0 dose, n = 8132;1 dose, n = 271;2 doses, n = 402, and 3 doses, n = 90. Data used in the analysis was facility operational and not from experimental design. Relative risk analysis of children who received 0, 1, 2, and 3 doses was done using Odds Ratio run on R software. Results: The relative risk of infection to a child with one dose against unvaccinated counterpart is 0.92 (95% CI, 0.61 - 1.43). Likewise the relative risk of infection to a child aged 12 - 17 years with 2 doses against another who received no dose is 0.87 (95% CI, 0.63 - 1.24). A child with 3 doses is 46% (95% CI, 27% - 84%) less likely to get infected compared to another not vaccinated. Also, the relative risk between having 2 doses and 1 dose for a child aged 12 - 17 years is 0.95 (95% CI, 0.55 - 1.6). For the same age group the relative risk of having 3 doses of vaccines against 1 dose is 51% (95% CI, 26% - 100%). In addition, a child who receives 3 doses of vaccine is 53% (95% CI, 28% - 100%) less likely to experience breakthrough infection compared to another with 2 doses. Whereas 1<sup>st</sup> dose offers (5%) marginal protection advantage over the 2<sup>nd</sup> dose, the 3r dose offers 49% and 47% more protection over 1<sup>st</sup> and 2<sup>nd</sup> doses, respectively, because of incremental reduced risk of infection gained from previous doses. During the period, 15 children at risk were admitted with COVID-19 infections in various regional hospitals, one had 3 doses but confounded with severe comorbidity. Conclusion: We found that 2<sup>nd</sup> dose had marginal protection over the 1<sup>st</sup> dose. However, the 3<sup>rd</sup> dose offers extensive protection compared to 1<sup>st</sup> and 2<sup>nd</sup> doses, and protects more against hospitalization. Children at risk should receive 3 doses of vaccines. 展开更多
关键词 Children Vaccination doses EFFECTIVENESS
下载PDF
Accurate models and nutritional strategies for specific oxidative stress factors: Does the dose matter in swine production?
4
作者 Changming Hong Yujian Huang +6 位作者 Shuting Cao Li Wang Xuefen Yang Shenglan Hu Kaiguo Gao Zongyong Jiang Hao Xiao 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2024年第2期519-534,共16页
Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxid... Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxidant strategies in relation to oxidative stress-induced pig production,it remains so far largely unsuccessful to develop accurate models and nutritional strategies for specific oxidative stress factors.Here,we discuss the dose and dose intensity of the causes of oxidative stress involving physiological,environmental and dietary factors,recent research models and the antioxidant strategies to provide theoretical guidance for future oxidative stress research in swine. 展开更多
关键词 Accurate models dose Nutritional strategies Oxidative stress SWINE
下载PDF
Helicobacter pylori:High dose amoxicillin does not improve primary or secondary eradication rates in an Irish cohort
5
作者 Conor Costigan Aoife M O'Sullivan +10 位作者 Jim O'Connell Shreyashee Sengupta Thomas Butler Stephen Molloy Fintan John O'Hara Barbara Ryan Niall Breslin Sarah O'Donnell Anthony O'Connor Sinead Smith Deirdre McNamara 《World Journal of Clinical Cases》 SCIE 2024年第16期2773-2779,共7页
BACKGROUND Helicobacter pylori(H.pylori)eradication rates have fallen globally,likely in large part due to increasing antibiotic resistance to traditional therapy.In areas of high clarithromycin and metronidazole resi... BACKGROUND Helicobacter pylori(H.pylori)eradication rates have fallen globally,likely in large part due to increasing antibiotic resistance to traditional therapy.In areas of high clarithromycin and metronidazole resistance such as ours,Maastricht VI guidelines suggest high dose amoxicillin dual therapy(HDADT)can be considered,subject to evidence for local efficacy.In this study we assess efficacy of HDADT therapy for H.pylori eradication in an Irish cohort.AIM To assess the efficacy of HDADT therapy for H.pylori eradication in an Irish cohort as both first line,and subsequent therapy for patients diagnosed with H.pylori.METHODS All patients testing positive for H.pylori in a tertiary centre were treated prospectively with HDADT(amoxicillin 1 g tid and esomeprazole 40 mg bid×14 d)over a period of 8 months.Eradication was confirmed with Urea Breath Test at least 4 wk after cessation of therapy.A delta-over-baseline>4%was considered positive.Patient demographics and treatment outcomes were recorded,analysed and controlled for basic demographics and prior H.pylori treatment.RESULTS One hundred and ninety-eight patients were identified with H.pylori infection,10 patients were excluded due to penicillin allergy and 38 patients refused follow up testing.In all 139 were included in the analysis,55%(n=76)were female,mean age was 46.6 years.Overall,93(67%)of patients were treatment-naïve and 46(33%)had received at least one previous course of treatment.The groups were statistically similar.Self-reported compliance with HDADT was 97%,mild side-effects occurred in 7%.There were no serious adverse drug reactions.Overall the eradication rate for our cohort was 56%(78/139).Eradication rates were worse for those with previous treatment[43%(20/46)vs 62%(58/93),P=0.0458,odds ratio=2.15].Age and Gender had no effect on eradication status.CONCLUSION Overall eradication rates with HDADT were disappointing.Despite being a simple and possibly better tolerated regime,these results do not support its routine use in a high dual resistance country.Further investigation of other regimens to achieve the>90%eradication target is needed. 展开更多
关键词 Helicobacter pylori eradication Helicobacter pylori High dose amoxicillin High dose amoxicillin dual therapy Triple therapy
下载PDF
Determination of Timer Error and Evaluation of Its Effect on Dose for OB6, GammaBeam X200 and X-Ray Irradiators at the Secondary Standard Dosimetry Laboratory in Nigeria
6
作者 Olumide Olaife Akerele Samuel Mofolorunsho Oyeyemi +3 位作者 David Olakanmi Olaniyi Francis Adole Agada Bamidele Musbau Adeniran Latifat Ronke Owoade 《World Journal of Nuclear Science and Technology》 CAS 2024年第2期118-130,共13页
Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irra... Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irradiators are Cs-137 OB6 irradiator and X-ray irradiators at the Protection level SSDL;and Co-60 irradiator at the Therapy Level SSDL. PTW UNIDOS electrometer and LS01 Ionization chamber were used at the Protection Level to obtain doses for both Cs-137 OB6 and X-ray irradiators while an IBA farmer type ionization chamber and an IBA DOSE 1 electrometer were used at the Protection Level SSDL. Single/multiple exposure method and graphical method were used in the determination of the timer error for the three irradiators. The timer error obtained for Cs-137 OB6 irradiator was 0.48 ± 0.01 s, the timer error for the X-ray irradiator was 0.09 ± 0.01 s while the timer error obtained for GammaBeam X200 was 1.21 ± 0.04 s. It was observed that the timer error is not affected by source to detector distance. It was also observed that the timer error of Co-60 Gamma X200 irradiator is increasing with the age of the machine. Source to detector distance and field size do not contribute towards the timer error of the irradiators. The timer error of the Co-60 Gamma X200 irradiator (the only irradiator among the irradiators with a pneumatic system) increases with the age of the irradiator. 展开更多
关键词 Timer Error Irradiation SSDL Irradiators dose Accuracy
下载PDF
Validation of the TOPAS Monte-Carlo Code of the Off-Field Dose of a 6 MV Synergy Linac
7
作者 Kodjo Joel Fabrice N’Guessan Ibrahima Sakho Bogbé D. L. H. Gogon 《Journal of Biosciences and Medicines》 2024年第7期38-54,共17页
The risk of radiation-induced second cancer and the late tissue loss due to Off-field doses in radiotherapy remain a serious concern. Monte Carlo (MC) simulation is currently one of the most accurate methods for calcu... The risk of radiation-induced second cancer and the late tissue loss due to Off-field doses in radiotherapy remain a serious concern. Monte Carlo (MC) simulation is currently one of the most accurate methods for calculating these doses. MC simulation model based on the Particle Simulation Tool (TOPAS) has been developed to simulate the off-field dose of an Elekta Synergy linear accelerator (Linac) emitting 6 MV photons. Measurements were taken in a water phantom using an ionization chamber to validate this model. The Percentage Depth Dose (PDD) at the depth of 0.0, 5.0, 10.0 and 15.0 cm from the beam axis for a 10 × 10 cm2 field size was measured and simulated. Off-field dose profiles at the depth of 1.5 (dmax), 5.0 and 10.0 cm for field sizes of 5 × 5, 10 × 10, 15 × 15, and 20 × 20 cm2 respectively were measured and simulated. Comparison of measured and simulated off-field dose values showed a good agreement. The average gamma passing rate of the PDDs and profiles curves for off-field doses were 87.5% and 98.11% respectively. The local dose difference based on the PDD curve between the measured and simulated was less than 6.0 % for all locations. For all field size considered in this study, the average difference between profile curves for off-field dose measured and simulated was 9.1%. PDDs and Profiles curves for off-field dose simulation uncertainties were less than 2.0% and 1.0% respectively. TOPAS-MC simulation model developed is a good representation of our 6 MV Linac Elekta Synergy for assessing off-field dose, which would be the primary cause of some secondary cancers. 展开更多
关键词 Radiotherapy Off-Field dose Secondary Cancer TOPAS-MC Simulation DOSIMETRY
下载PDF
Life Time Attributable Cancer Risk Estimated Using Scanner Reported Dose Length Product during Chest Computed Tomography Imaging in Young Children
8
作者 Mousa Bakkari Khaled Soliman +3 位作者 Abdullah Alrushoud Marwan Fahad Alosaimi Hanaa Alsheikh Abdelwahed Alhejaili 《Open Journal of Radiology》 2024年第2期74-82,共9页
This study aims to estimate the lifetime attributable cancer risk (LAR) for pediatric chest computed tomography (CT) examinations in five age groups using recently published age and region-specific conversion coeffici... This study aims to estimate the lifetime attributable cancer risk (LAR) for pediatric chest computed tomography (CT) examinations in five age groups using recently published age and region-specific conversion coefficients multiplying the widely available scanner registered dose length products (DLP) displayed on the CT console and hence calculating the Effective Dose (ED). The ED is then multiplied by the International Commission on Radiological Protection (ICRP) published risk factor for LAR. The obtained LAR values are compared with the international literature. Factors that may affect the LAR value are reported and discussed. The study included one hundred twenty five chest CT examinations for both males and females aged from less than one year to fifteen years. The patients reported data are from one single medical institution and using two CT scanners from June 2022 to December 2023. The results of this study may serve as benchmark for institutional radiation dose reference levels and risk estimation. 展开更多
关键词 Cancer Risk LAR Chest CT Pediatric Radiology Radiation dose DLP
下载PDF
Total ionizing dose effect modeling method for CMOS digital-integrated circuit
9
作者 Bo Liang Jin-Hui Liu +3 位作者 Xiao-Peng Zhang Gang Liu Wen-Dan Tan Xin-Dan Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第2期32-46,共15页
Simulating the total ionizing dose(TID)of an electrical system using transistor-level models can be difficult and expensive,particularly for digital-integrated circuits(ICs).In this study,a method for modeling TID eff... Simulating the total ionizing dose(TID)of an electrical system using transistor-level models can be difficult and expensive,particularly for digital-integrated circuits(ICs).In this study,a method for modeling TID effects in complementary metaloxide semiconductor(CMOS)digital ICs based on the input/output buffer information specification(IBIS)was proposed.The digital IC was first divided into three parts based on its internal structure:the input buffer,output buffer,and functional area.Each of these three parts was separately modeled.Using the IBIS model,the transistor V-I characteristic curves of the buffers were processed,and the physical parameters were extracted and modeled using VHDL-AMS.In the functional area,logic functions were modeled in VHDL according to the data sheet.A golden digital IC model was developed by combining the input buffer,output buffer,and functional area models.Furthermore,the golden ratio was reconstructed based on TID experimental data,enabling the assessment of TID effects on the threshold voltage,carrier mobility,and time series of the digital IC.TID experiments were conducted using a CMOS non-inverting multiplexer,NC7SZ157,and the results were compared with the simulation results,which showed that the relative errors were less than 2%at each dose point.This confirms the practicality and accuracy of the proposed modeling method.The TID effect model for digital ICs developed using this modeling technique includes both the logical function of the IC and changes in electrical properties and functional degradation impacted by TID,which has potential applications in the design of radiation-hardening tolerance in digital ICs. 展开更多
关键词 CMOS digital-integrated circuit Total ionizing dose IBIS model Behavior-physical hybrid model Physical parameters
下载PDF
Establishment of NaLuF_(4):15%Tb-based low dose X-PDT agent and its application on efficient antitumor therapy
10
作者 Yi Tian Zhiguang Fu +7 位作者 Xiaosheng Zhu Chunjing Zhan Jinwei Hu Li Fan Chaojun Song Qian Yang Yu Wang Mei Shi 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第3期599-610,共12页
X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.Howev... X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.However,high X-ray irradiation dose caused organ lesions and side effects became the major barrier to X-PDT application.To address this issue,this work employed a classic-al co-precipitation reaction to synthesize NaLuF_(4):15%Tb^(3+)(NLF)with an average particle size of(23.48±0.91)nm,which was then coupled with the photosensitizer merocyanine 540(MC540)to form the X-PDT system NLF-MC540 with high production of singlet oxygen.The system could induce antitumor efficacy to about 24%in relative low dose X-ray irradiation range(0.1-0.3 Gy).In vivo,when NLF-MC540 irradiated by 0.1 Gy X-ray,the tumor inhibition percentage reached 89.5%±5.7%.The therapeutic mechanism of low dose X-PDT was found.A significant increase of neutrophils in serum was found on the third day after X-PDT.By immunohistochemical staining of tumor sections,the Ly6G^(+),CD8^(+),and CD11c^(+)cells infiltrated in the tumor microenvironment were studied.Utilizing the bilat-eral tumor model,the NLF-MC540 with 0.1 Gy X-ray irradiation could inhibit both the primary tumor and the distant tumor growth.De-tected by enzyme linked immunosorbent assay(ELISA),two cytokines IFN-γand TNF-αin serum were upregulated 7 and 6 times than negative control,respectively.Detected by enzyme linked immune spot assay(ELISPOT),the number of immune cells attributable to the IFN-γand TNF-αlevels in the group of low dose X-PDT were 14 and 6 times greater than that in the negative control group,respectively.Thus,it conclude that low dose X-PDT system could successfully upregulate the levels of immune cells,stimulate the secretion of cy-tokines(especially IFN-γand TNF-α),activate antitumor immunity,and finally inhibit colon tumor growth. 展开更多
关键词 X-ray excited photodynamic therapy singlet oxygen low dose X-Ray irradiation efficient antitumor therapy anti-tumor immunity
下载PDF
Normalized glandular dose coefficients for digital breast tomosynthesis using detailed Chinese breast models
11
作者 Jia-Hao Wang Rui Qiu +4 位作者 An-Kang Hu Ye-Qi Liu Zhen Wu Hui Zhang Jun-Li Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第5期42-59,共18页
The rise in breast cancer diagnoses among Chinese women has necessitated the use of X-ray breast screening,which carries a radiation risk.This study aimed to provide a dosimetry protocol for the Chinese female populat... The rise in breast cancer diagnoses among Chinese women has necessitated the use of X-ray breast screening,which carries a radiation risk.This study aimed to provide a dosimetry protocol for the Chinese female population to replace the traditional standard that utilizes simplified breast models,for the accurate estimation of the mean glandular dose of a patient undergoing digital breast tomosynthesis(DBT).The first set of detailed Chinese female breast models and representative breast parameters was constructed.Considering backscatter radiation and computational efficiency,we improved the combination of these models and the Chinese reference adult female whole-body voxel phantom.Image acquisition for four commercial DBT systems that are widely employed in China was simulated using the Monte Carlo method to obtain the normalized glandular dose coefficients of DBT(D_(gN)^(DBT))and the glandular depth dose(D_(g)^(dep)(z))for different breast characteristics and X-ray spectra.We calculated a series of D_(gN)^(DBT) values for breasts with different percentage mass glandularities(5%,25%,50%,75%,and 100%)and compressed breast thicknesses(2,3,4,5,6,and 7 cm)at various tube potentials(25,28,30,32,35,and 49 kV)and target/filter combinations(W/Rh,W/Al,Mo/Mo,Rh/Rh,and Rh/Ag).The parameter dependence of the breast characteristics and beam conditions on D_(gN)^(DBT) in detailed breast models was investigated.The D_(gN)^(DBT) results were 14.6-51.0%lower than those of the traditional dosimetry standard in China.The difference in D_(gN)^(DBT) was mainly due to a decrease in the depth of the main energy deposition area caused by the glandular distribution along the depth direction.The results obtained in this study may be used to improve breast dosimetry in China and provide more detailed information on risk assessment during DBT. 展开更多
关键词 Digital breast tomosynthesis Normalized glandular dose coefficients Detailed breast model Monte Carlo simulation
下载PDF
利用Batch Implant机台离子注入dose梯度分布调控注入均匀性的技术分析
12
作者 庞宏庄 国子明 《集成电路应用》 2024年第2期44-47,共4页
阐述发现batch implant机台所作业的wafer状况,在wafer面内存在规律性梯度差异的dose分布。基于wafer processing过程中的形变现象,通过fine tune beam line及优化diskangle条件,可以定量设计dose梯度分布情况。通过优化离子注入在wafe... 阐述发现batch implant机台所作业的wafer状况,在wafer面内存在规律性梯度差异的dose分布。基于wafer processing过程中的形变现象,通过fine tune beam line及优化diskangle条件,可以定量设计dose梯度分布情况。通过优化离子注入在wafer面内分布的dose对称性,可以有效改善离子注入均匀性。 展开更多
关键词 集成电路制造 dose梯度 dose对称性 离子注入均匀性
下载PDF
High-dose methotrexate and zanubrutinib combination therapy for primary central nervous system lymphoma
13
作者 Budhi Singh Yadav 《World Journal of Clinical Oncology》 2024年第3期371-374,共4页
In this editorial I comment on the article,published in the current issue of the World Journal of Clinical Oncology.Primary central nervous system lymphoma(PCNSL)is a disease of elderly and immunocompromised patients.... In this editorial I comment on the article,published in the current issue of the World Journal of Clinical Oncology.Primary central nervous system lymphoma(PCNSL)is a disease of elderly and immunocompromised patients.The authors reported clinical results of 19 patients with PCNSL treated with zanubrutinib/high dose methotrexate(HD-MTX)until disease progression.They demonstrated that the combination of zanubrutinib with HD-MTX led to a marked clinical response and tolerability among these patients.They also observed that cerebrospinal fluid liquid biopsy to detect circulating tumor DNA may be a good option for evaluating treatment response and tumor burden in patients with PCNSL.PCNSL is a challenging disease for treatment as these patients present with different neurological states and comorbidities.Treatment has evolved over the years from whole brain radiotherapy to HD-MTX followed by autologous stem cell transplant.Gradually,treatment of patients with PCNSL is going to become individualized. 展开更多
关键词 Primary central nervous system lymphoma High dose methotrexate Zanubrutinib Whole brain radiotherapy Liquid biopsy
下载PDF
Predicting 3D Radiotherapy Dose-Volume Based on Deep Learning
14
作者 Do Nang Toan Lam Thanh Hien +2 位作者 Ha Manh Toan Nguyen Trong Vinh Pham Trung Hieu 《Intelligent Automation & Soft Computing》 2024年第2期319-335,共17页
Cancer is one of the most dangerous diseaseswith highmortality.One of the principal treatments is radiotherapy by using radiation beams to destroy cancer cells and this workflow requires a lot of experience and skill ... Cancer is one of the most dangerous diseaseswith highmortality.One of the principal treatments is radiotherapy by using radiation beams to destroy cancer cells and this workflow requires a lot of experience and skill from doctors and technicians.In our study,we focused on the 3D dose prediction problem in radiotherapy by applying the deeplearning approach to computed tomography(CT)images of cancer patients.Medical image data has more complex characteristics than normal image data,and this research aims to explore the effectiveness of data preprocessing and augmentation in the context of the 3D dose prediction problem.We proposed four strategies to clarify our hypothesis in different aspects of applying data preprocessing and augmentation.In strategies,we trained our custom convolutional neural network model which has a structure inspired by the U-net,and residual blocks were also applied to the architecture.The output of the network is added with a rectified linear unit(Re-Lu)function for each pixel to ensure there are no negative values,which are absurd with radiation doses.Our experiments were conducted on the dataset of the Open Knowledge-Based Planning Challenge which was collected from head and neck cancer patients treatedwith radiation therapy.The results of four strategies showthat our hypothesis is rational by evaluating metrics in terms of the Dose-score and the Dose-volume histogram score(DVH-score).In the best training cases,the Dose-score is 3.08 and the DVH-score is 1.78.In addition,we also conducted a comparison with the results of another study in the same context of using the loss function. 展开更多
关键词 CT image 3D dose prediction data preprocessing augmentation
下载PDF
Analysis of the Effect of High-Dose Segmental Citrate Anticoagulation in High Flux Hemodialysis
15
作者 Xubo Fu 《Journal of Clinical and Nursing Research》 2024年第5期95-99,共5页
Objective:To analyze the clinical effect of high-dose citrate in segmental extracorporeal anticoagulation for high-throughput hemodialysis.Methods:The subjects included in this study were admitted to the hospital for ... Objective:To analyze the clinical effect of high-dose citrate in segmental extracorporeal anticoagulation for high-throughput hemodialysis.Methods:The subjects included in this study were admitted to the hospital for maintenance hemodialysis treatment from January 2021 to January 2023.All patients had a high risk of bleeding and received 4%trisodium citrate anticoagulant treatment,administered at a rate of 200 mL/h before and after the dialyzer.The anticoagulant effects achieved by the patients were observed and analyzed.Results:The total number of patients who received high-dose segmented citrate extracorporeal anticoagulation dialysis treatment was 50,with each patient undergoing 100 treatments.During the treatment,2 patients had to end the treatment early due to transmembrane pressure exceeding 30 mmHg and an increase in venous pressure exceeding 250 mmHg;the treatment times for these patients were 20 minutes and 200 minutes,respectively.The remaining patients successfully completed the 4-hour treatment.Blood pH and calcium ion concentration in the venous pot were monitored.It was observed that before dialysis,after 2 hours of dialysis,and at the end of dialysis,the blood pH of the patients remained within a relatively normal range.Although some patient levels changed after dialysis,they remained within the normal range.No adverse reactions(such as numbness of the limbs or convulsions)were observed during the anticoagulant treatment.Conclusion:Administering 4%trisodium citrate at a rate of 200 mL/h before and after the dialyzer achieves a good anticoagulant effect,maintains the patient’s blood gas levels within the normal range at the end of dialysis,and causes no adverse reactions. 展开更多
关键词 High dose Segmented citrate High flux HEMODIALYSIS Anticoagulation effect
下载PDF
迭代模型重建与iDose4混合迭代重建在头颈部低剂量CT血管成像中的应用比较
16
作者 朱维聪 曾慧芸 +2 位作者 杜晨 吴雅婷 王彬 《影像诊断与介入放射学》 2024年第3期193-199,共7页
目的探讨迭代模型重建(IMR)对比iDose4混合迭代重建技术在低辐射剂量和低碘摄入量头颈部CT血管成像(CTA)中的应用比较。方法收集本院2024年1月—5月因需行头颈部联合动脉CTA检查,且身体质量指数不超过30 kg/m2的患者60例,分为对照组和... 目的探讨迭代模型重建(IMR)对比iDose4混合迭代重建技术在低辐射剂量和低碘摄入量头颈部CT血管成像(CTA)中的应用比较。方法收集本院2024年1月—5月因需行头颈部联合动脉CTA检查,且身体质量指数不超过30 kg/m2的患者60例,分为对照组和实验组,每组各30例。对照组采用120 kV、150 mAs、对比剂用量50 mL、注射流率5 mL/s和iDose4重建;实验组采用100 kV、100 mAs、对比剂用量30 mL、注射流率3 mL/s,分别使用iDose4和IMR进行图像重建,得到iDsoe4组和IMR组两组重建图像。测量并计算三组图像左侧颈总动脉起始部、左侧颈内动脉起始部和大脑中动脉M1段血管CT值、标准差(SD)、信噪比(SNR)和对比噪声比(CNR);记录并比较对照组和实验组病例容积CT剂量指数、剂量长度乘积,并计算有效剂量。2名诊断医师对图像质量进行主观评分。辐射剂量的比较采用独立样本t检验;CT值、SD、SNR、CNR、主观质量评分的比较采用方差分析或韦尔奇检验,两两比较采用LSD-t检验或Tamhane’s T2检验。结果对照组与IMR组各血管主观质量评分、SD、SNR、CNR的比较差异均无显著性(P>0.05);iDose4组各血管主观质量评分、SNR、CNR均明显低于对照组和IMR组,差异具有显著性(P<0.05);对照组各对应血管的CT值均明显高于iDose4组和IMR组,差异具有显著性(P<0.05);实验组有效剂量(1.62±0.08)较对照组(0.69±0.33)下降了约57.41%,对比剂碘摄入量减少了40%。结论在头颈部CTA检查中,采用低管电压、低管电流、低注射剂量及低注射流率联合IMR技术,可在保证图像质量的同时显著地降低患者辐射剂量和碘摄入量,IMR技术在降低图像噪声、提高图像SNR和CNR方面优于iDose4重建。 展开更多
关键词 迭代模型重建 辐射剂量 对比剂 CT血管成像
下载PDF
Low Doses of Rifampicin Used in New Tuberculosis Patients Correlated to Increased Frequency of Rifampicin-Resistance and Poorer Treatment Outcomes 被引量:12
17
作者 Ling Chen Jian Du +18 位作者 Liang Li Qi Li Qiu Zhong Yanyong Fu Bo Li Minggui Lin Liping Ma Youlun Li Xiaomeng Wang Yan Ma Xiaoying Jiang Xiaoyou Chen Qiping Ge Li Xie Xiqin Han Zhaogang Sun Guanglu Jiang Hong Zhang Weiwei Gao 《Open Journal of Medical Microbiology》 2015年第2期76-84,共9页
The prognosis of patients with previously treated tuberculosis (TB) was suggested to be dependent on whether the initial treatment was in compliance with the established guidelines. The aim of this retrospective multi... The prognosis of patients with previously treated tuberculosis (TB) was suggested to be dependent on whether the initial treatment was in compliance with the established guidelines. The aim of this retrospective multicenter study was to determine the proportion of new TB patients who received standard doses of rifampicin in multiple provinces of China, and the relationship between low doses of rifampicin and frequency of rifampicin-resistance as well as treatment outcomes. A total of 713 new TB patients were treated with either once-daily dose of bulk anti-TB drugs (group I) or every other day combination blister packs of anti-TB drugs containing rifampicin (group II) at more than 30 TB treatment centers/hospitals in China. Treatment history, therapeutic doses of rifampicin, and information about patients were extracted from their medical records and analyzed, and rifampicin-resistance of isolates collected from patients following the treatment as well as treatment outcomes were compared between two treatment groups. Among 522 patients in treatment group I, 154 (29.5%) received standard and 363 (69.5%) received low doses of rifampicin;238 (45.6%) isolates were rifampicin-resistant, and 243 (46.6%) were successfully treated. Among 191 patients in treatment group II, 175 (91.6%) received standard and 15 (7.9%) received low doses of rifampicin;72 (37.7%) isolates were rifampicin-resistant, and 105 (55%) were successfully treated. When patients who received low doses of rifampicin were compared to others within the same treatment group, increased rates for rifampicin-resistance and treatment failure were observed. Results from this study showed that most new TB patients in treatment group I (69.5%) received low doses of rifampicin, and their treatment outcomes were worse than those in treatment group II, indicating that low doses of rifampicin used for the initial treatment of new TB patients were correlated to increased frequency of rifampicin-resistance and poorer treatment outcomes. 展开更多
关键词 MYCOBACTERIUM TUBERCULOSIS RIFAMPICIN THERAPEUTIC doses Drug RESISTANCE Treatment Outcomes
下载PDF
Radiological characterization of building materials used in Malaysia and assessment of external and internal doses 被引量:1
18
作者 Shittu Abdullahi Aznan Fazli Ismail Supian Samat 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期82-96,共15页
In this study, the activity concentrations of ^(226)Ra,^(232)Th,^(222)Rn, and ^(40)K, emanation fractions(P),equilibrium equivalent concentration(EEC), and mass exhalation rates(E_m) of radon released from building ma... In this study, the activity concentrations of ^(226)Ra,^(232)Th,^(222)Rn, and ^(40)K, emanation fractions(P),equilibrium equivalent concentration(EEC), and mass exhalation rates(E_m) of radon released from building materials used in Malaysia were studied using gamma-ray spectrometer with HPGe detector. Radiological parameters[activity concentration index(ACI), indoor air-absorbed dose rate(D_(in)), annual effective dose(AED_(in)) from external and internal(E_(Rn)), soft tissues(H_(ST)) and lung(H_L), and effective dose equivalent(H_(eff))] were estimated to evaluate radiological hazards due to the use of these building materials: sand, cement, gravel, bricks, tiles, fly ash, white cement, and ceramic raw materials. The measured P, EEC,and E_m vary from 10 to 30%, 0.9 to 22 Bq m^(-3), and 33 to 674 mBq h^(-1) kg^(-1), respectively, while the calculated ACI and AED_(in) vary from 0.1 ± 0.01 to 2.1 ± 0.1 and 0.1 ± 0.01 to 2.4 ± 0.6 mSv y^(-1), respectively. On the other hand, the internal annual effective dose ranges from 0.1 to 1.4 mSv y^(-1). The estimated radiological risk parameters were below the recommended maximum values, and radiological hazards associated with building materials under investigation are therefore negligible. 展开更多
关键词 Indoor radon EMANATION fraction Equilibrium EQUIVALENT concentration Mass EXHALATION rate Annual EFFECTIVE dose EFFECTIVE dose EQUIVALENT
下载PDF
Pharmacokinetics of Controlled Release and Immediate Release Morphine Sulphate Tablets after a Single Dose and Multiple Doses in Chinese Volunteers
19
作者 邓艳萍 王凯 +3 位作者 刘立京 刘静雯 蔡志基 楼雅卿 《Journal of Chinese Pharmaceutical Sciences》 CAS 1997年第4期39-42,共4页
健康志愿者10名,随机交叉口服硫酸吗啡控释片(CRMS)30mg(30mg×1)和硫酸吗啡普通片(IRMS)20mg(10mg×2),分别于服药前后各时点取静脉血,用GCMS测定血浆中吗啡含量。以药代软件程... 健康志愿者10名,随机交叉口服硫酸吗啡控释片(CRMS)30mg(30mg×1)和硫酸吗啡普通片(IRMS)20mg(10mg×2),分别于服药前后各时点取静脉血,用GCMS测定血浆中吗啡含量。以药代软件程序处理,分别求得CRMS和IRMS的Cmax为19.38±3.80和21.27±6.21ng/ml;tmax为2.36±0.37h和0.55±0.16h;t1/2β为3.53±0.87h和3.03±0.74h,曲线下面积AUC为145.15±17.65和93.08±16.65ng·h/ml。癌症病人多次口服硫酸吗啡至稳态,CRMS和IRMS的峰浓度分别为27.43±0.33ng/ml,22.68±0.16ng/ml;谷浓度分别为19.45±1.44ng/ml;18.14±0.49ng/ml。 展开更多
关键词 硫酸吗啡控释片 硫酸吗啡普通片 药代动力学 单次给药 多次给药 GC-MS
全文增补中
Adult Patient Doses for Chest, Skull and Lumbar Spine Examinations 被引量:1
20
作者 Kouther E. M. Mohamadain F. I. Habbani S. M. Ibrahim 《Open Journal of Radiology》 2015年第1期44-49,共6页
A dosimetry study for chest, skull and lumbar spine examinations in adults has been carried out at two hospitals. The aim of the study was the assessment of adult patient’s dose for chest PA, chest LAT, skull AP and ... A dosimetry study for chest, skull and lumbar spine examinations in adults has been carried out at two hospitals. The aim of the study was the assessment of adult patient’s dose for chest PA, chest LAT, skull AP and lumbar spine AP examinations. The Entrance Surface Dose (ESD) and the Effective Dose (ED) for each examination were obtained using DoseCal software. For each examination, different results were obtained at the two hospitals. At hospital A (IFF Hospital), the total number of patients studied was 140. The mean ESD values obtained for chest PA, chest LAT, skull AP and lumbar spine AP were 0.20 mGy, 0.47 mGy, 1.25 mGy, and 1.61 mGy, respectively. At hospital B (HGB Hospital), the total number of patients studied was 369 for similar examinations and projections. The ESD values were 0.10 mGy, 0.28 mGy, 0.66 mGy and 2.47 mGy, respectively. The mean ED values at hospital A and B were 0.02 mSv and 0.01 mSv for chest PA, 0.04 mSv and 0.03 mSv for chest LAT, 0.1 mSv and 0.06 mSv for skull AP, and 0.15 mSv and 0.26 mSv for lumbar spine AP, respectively. The results were compared with the European Community Reference Levels. Although the doses were low, there was still a need for personnel training and national guidance on good practice for optimization of patients’ doses. 展开更多
关键词 ENTRANCE dose Effective dose dose CAL Software
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部