Nowadays, clients require solutions that are efficient during the service life as a whole. In this view, maintenance has functional value and greatly contributes to increasing quality in environments. With reference t...Nowadays, clients require solutions that are efficient during the service life as a whole. In this view, maintenance has functional value and greatly contributes to increasing quality in environments. With reference to maintenance phase and residual value of building products upon dismantling, the present manuscript investigates a set of technological packages of quality and technical value referred to two alternative facade systems available for recovery actions on Italian council buildings--the ETICS (external thermal insulation composite system) and the external cladding system--complying with one thermal-insulation strategy, but different in terms of service life duration. Preservation of technical value and value increases are strictly related to maintenance quality and efficiency. Volume of investments in maintenance is not the only parameter to be considered to assess facade-system-management quality. Time-accurate economic assessment requires the entity to be related to periodical checks on performance quality in the building system and in its parts. Effective technical data to draw up consistent estimates and appraisals are rarely available in literature. With all that stated above, the present manuscript aims at introducing technical data related to drawing up reliable cost estimates and effective appraisals in terms of economics, quality and environmental sustainability. Conclusions will be drawn from the end of the manuscript.展开更多
The glass facade of high-rise building in coastal areas is vulnerable under typhoon.The research works in the literature on facade's wind-resistance performance,however,have some limitations to apply to this issue...The glass facade of high-rise building in coastal areas is vulnerable under typhoon.The research works in the literature on facade's wind-resistance performance,however,have some limitations to apply to this issue.During typhoon landing,the whole facade will vibrate and deform due to the change of atmosphere,temperature and impacted torrential rain,to result in a quite different strain or stress distribution in the glass facade from those in model test and wind tunnel test.In this paper,the field measurement on glass facade of a coastal high-rise building in Xiamen was performed,the wind pressure on the glass facade was measured and a large number of windinduced stress data were obtained during typhoon landing.The relationship between wind pressure and stress or strain of the glass panel was analyzed and the situation of stress distribution was summarized.展开更多
文摘Nowadays, clients require solutions that are efficient during the service life as a whole. In this view, maintenance has functional value and greatly contributes to increasing quality in environments. With reference to maintenance phase and residual value of building products upon dismantling, the present manuscript investigates a set of technological packages of quality and technical value referred to two alternative facade systems available for recovery actions on Italian council buildings--the ETICS (external thermal insulation composite system) and the external cladding system--complying with one thermal-insulation strategy, but different in terms of service life duration. Preservation of technical value and value increases are strictly related to maintenance quality and efficiency. Volume of investments in maintenance is not the only parameter to be considered to assess facade-system-management quality. Time-accurate economic assessment requires the entity to be related to periodical checks on performance quality in the building system and in its parts. Effective technical data to draw up consistent estimates and appraisals are rarely available in literature. With all that stated above, the present manuscript aims at introducing technical data related to drawing up reliable cost estimates and effective appraisals in terms of economics, quality and environmental sustainability. Conclusions will be drawn from the end of the manuscript.
基金supported by the National Natural Science Foundation of China (Grant Nos. 90815030,50978094,51008237)
文摘The glass facade of high-rise building in coastal areas is vulnerable under typhoon.The research works in the literature on facade's wind-resistance performance,however,have some limitations to apply to this issue.During typhoon landing,the whole facade will vibrate and deform due to the change of atmosphere,temperature and impacted torrential rain,to result in a quite different strain or stress distribution in the glass facade from those in model test and wind tunnel test.In this paper,the field measurement on glass facade of a coastal high-rise building in Xiamen was performed,the wind pressure on the glass facade was measured and a large number of windinduced stress data were obtained during typhoon landing.The relationship between wind pressure and stress or strain of the glass panel was analyzed and the situation of stress distribution was summarized.