期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
关于智能变电站防雷保护的探讨
1
作者 钱江川 《科技创新导报》 2014年第6期62-62,共1页
根据智能变电站特点,进行智能变电站防雷保护分析,探讨智能变电站防雷保护措施。
关键词 智能变电站 建筑物及设备 () 保护
下载PDF
ASSESSMENT OF AIRCRAFT COMBAT SURVIVABILITY ENHANCED BY COMBINED RADAR STEALTH AND ONBOARD ELECTRONIC ATTACK 被引量:1
2
作者 黄俊 武哲 +1 位作者 向锦武 朱荣昌 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2000年第2期150-156,共7页
The combat survivability is an essential factor to be considered in the development of recent military aircraft. Radar stealth and onboard electronic attack are two major techniques for the reduction of aircraft susce... The combat survivability is an essential factor to be considered in the development of recent military aircraft. Radar stealth and onboard electronic attack are two major techniques for the reduction of aircraft susceptibility. A tactical scenario for a strike mission is presented. The effect of aircraft radar cross section on the detection probability of a threat radar, as well as that of onboard jammer, are investigated. The guidance errors of radar guided surface to air missile and anti aircraft artillery, which are disturbed by radar cross section reduction or jammer radiated power and both of them are determined. The probability of aircraft kill given a single shot is calculated and finally the sortie survivability of an attack aircraft in a supposed hostile thread environment worked out. It is demonstrated that the survivability of a combat aircraft will be greatly enhanced by the combined radar stealth and onboard electronic attack, and the evaluation metho dology is effective and applicable. 展开更多
关键词 combat survivability radar cross section electronic attack detection guidance error
下载PDF
Power Network Lightning Accident Quick Inquiry with the Lightning Location System 被引量:4
3
作者 NIE Zhiping ZHAO Wenguang ZHANG Ping WEN Yinping CHEN Weijiang 《Geo-Spatial Information Science》 2008年第1期43-48,共6页
At present, lightning is one of the 10 natural disasters, and it is also the top environmental factor of power interruption. It often causes huge losses to the electric system. The Wuhan High Voltage Institute of the ... At present, lightning is one of the 10 natural disasters, and it is also the top environmental factor of power interruption. It often causes huge losses to the electric system. The Wuhan High Voltage Institute of the State Grid Corporation of China and Huazhong University of Science and Technology have been researching and developing lightning location systems (LLSs) since the late 1980s. In the mid-1990s, a lightning detection network was created in 29 provinces and cities in China. It is primarily applied to rapidly find lightning accidents, which greatly reduces power interruption. Also, it ensures high efficiency and safe operation of the electricity system. Remarkable benefit is achieved. China's LLS went through an "orientation positioning - time difference positioning - integrated positioning" development process. The positioning precision, detection efficiency, degree of automation, practicability and applied range are improved. Also, a lightning information system plan of the national network has been implemented, which services the whole society. 展开更多
关键词 lightning location power network lightning accident accident inquiry lightning information system
下载PDF
The Protection against Lightning of an Overhead Line Uprated from 225 kV to 400 kV 被引量:1
4
作者 Alain Xemard Sebastien Dennetiere +6 位作者 Ivo Uglesic Viktor Milardic Bosko Milesevic Philippe Grand Frangois Sauvegrain Pierre Stevenin Miroslav Mesic 《Journal of Energy and Power Engineering》 2012年第2期267-275,共9页
The voltage uprating of existing overhead lines is an interesting solution for increasing the transmission of electricity, especially in areas where it is difficult to build new lines. If a line is uprated with minor ... The voltage uprating of existing overhead lines is an interesting solution for increasing the transmission of electricity, especially in areas where it is difficult to build new lines. If a line is uprated with minor changes of its design and without improvement of the grounding electrodes of towers, its lightning performance remains unchanged. The consequence is that the uprated line will have a lightning flashover rate very high compared to an overhead line of same nominal voltage but of standard design. One attractive solution to solve this problem is to use line arresters. The goal of this paper is to study the use of line arresters to achieve a satisfactory lightning performance of an overhead line uprated from 225 kV to 400 kV without major design modifications. In order to compare different strategies of line arrester installation the flashover rate is calculated based on a software able to launch automatically EMTP-RV. The software named LIPS has been developed under the cover of a partnership between Hydro-Quebec, RTE and EDF. 展开更多
关键词 LIGHTNING transmission line voltage uprating insulation coordination.
下载PDF
Lightning Induced Surge on the Distribution Lines in the House near by the Lightning Point
5
作者 Aiko Takahara Ryoji Oshiro Eiji Kaneko 《Journal of Energy and Power Engineering》 2012年第5期840-844,共5页
Recently, a lightning surge is recognized as one of the biggest risks to the society. If the surges induced by lightning invade into low voltage distribution lines, there might be a possibility of giving some severe d... Recently, a lightning surge is recognized as one of the biggest risks to the society. If the surges induced by lightning invade into low voltage distribution lines, there might be a possibility of giving some severe damages to the systems. Therefore, it is necessary to examine these induced phenomena. FDTD (finite difference time domain) method which treats objects as three-dimensional solid circuits is applied to analyze these induced phenomena. VSTL (Virtual Surge Test Lab.) is the surge analysis simulation program using FDTD method. In this paper, the lightning induced phenomena on the low voltage distribution line in the house are analyzed by using VSTL. In this paper, investigation results about induced surge when a lightning struck the point nearby the house, and about a suppressing effect of surges by comparing the results of analysis with and without SPD (surge protective device) are shown. As a result, it is confirmed that SPD is effective for suppressing lightning surge. 展开更多
关键词 Lightning surge induced phenomena FDTD method distribution line VSTL.
下载PDF
Contribution to the Study and Analysis of the Lightning Aggression on the Wind Turbine
6
作者 Dib Djalel Mourdjaoui Mourad Abada Zhour 《Journal of Energy and Power Engineering》 2013年第5期891-898,共8页
Generally, lightning damage has mainly been to home appliances and telephones, towers and power transmission and generation equipment mal functions and damage due to strikes on power lines. With the adoption of wind p... Generally, lightning damage has mainly been to home appliances and telephones, towers and power transmission and generation equipment mal functions and damage due to strikes on power lines. With the adoption of wind power generation equipment, however, lightning damage is also increasing in this area. Through his dimensional characteristics, the wind power system is more exposed in the nature compared to all others systems. Lightning damage is the single largest cause of unplanned downtime in wind turbines, and that downtime is responsible for the loss of countless megawatts of power generation. The wind turbines are important structures, since they can easily attract the wrath of storms hits heights close, they can also capture the most distant. The rotation of the blades may also trigger lightning and result in considerable increase in the number of strikes to a wind turbine unit. Since wind turbines are tall structures, the lightning currents that are injected by return strokes into the turbines will be affected by reflections at the top, at the bottom, and at the junction of the blades with the static base of the turbine. We present our contribution in this paper to study lightning strokes and their effects on the wind turbines with the aim to enrich the work and to suggest more effective means of protection against lightning. 展开更多
关键词 Wind turbine LIGHTNING protection BLADE current return stroke carbon reinforced plastics.
下载PDF
Comparative Study of Streamers' Characteristics in Different Seed Based Insulating Oils under Lightning Impulse Voltages
7
作者 Abderrahmane Beroual1 Viet-Hung Dang +1 位作者 Essam Al-Ammar Muhammad Iqbal Qureshi 《Journal of Energy and Power Engineering》 2014年第4期735-740,共6页
This paper is aimed at the streamers in natural esters (vegetable oils) in point--plane electrode arrangement under lightning impulse voltage. The shape, stopping length, velocity and current of streamers are invest... This paper is aimed at the streamers in natural esters (vegetable oils) in point--plane electrode arrangement under lightning impulse voltage. The shape, stopping length, velocity and current of streamers are investigated. Six untreated commercial oils extracted from grape seeds, sunflower and rape seeds, corn, rice and sesame that could constitute potential liquids for high voltage applications are tested. A naphthenic mineral oil is also tested for comparison. It's shown that the streamers are filamentary for both polarities. For a given voltage, the stopping lengths (Lf) of streamers are longer when the point is positive than when it is negative; also, except mineral oil when the point is negative, the values of Lf-are very close in all tested oils. The streamers' velocities are in the same range for all vegetable oils and they vary between 0.4 km/s and 1.2 km/s for positive polarity and 0.2 km/s and 0.8 km/s for negative polarity. 展开更多
关键词 Natural esters mineral oil streamer shape stopping length streamer velocity streamer current.
下载PDF
Analysis of false alarm for imaging space-based laser warning system
8
作者 董红军 周中亮 黄富瑜 《Optoelectronics Letters》 EI 2012年第2期105-108,共4页
In view of the problem of false alarm in imaging space-based laser warning system, the effects of sunlight and lightning on the threaten laser detection and attack event determination are studied by analyzing and calc... In view of the problem of false alarm in imaging space-based laser warning system, the effects of sunlight and lightning on the threaten laser detection and attack event determination are studied by analyzing and calculating the radiant energy density and space-time feature of imaging spot, respectively. The results show that the main false alarm resourses of space- based laser warning system are sunlight and lightning. The sunlight should exposure the detector directly in one ninth of the satfllite orbital period, and the imaging spot of sun is similar to the attack laser. The lightning imaging spot is similar to the illumination laser. About 1.4 lightning events can occur in the field of view (FOV) of the warning system per second. It could not discriminate spots of sun, lightning and threaten laser by the frame subtraction technology. 展开更多
关键词 Alarm systems ERRORS
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部