In this paper, a new adaptive optimal guidance law with impact angle and seeker’s field-of-view(FOV) angle constraints is proposed. To this end, the generalized optimal guidance law is derived first. A changeable imp...In this paper, a new adaptive optimal guidance law with impact angle and seeker’s field-of-view(FOV) angle constraints is proposed. To this end, the generalized optimal guidance law is derived first. A changeable impact angle weighting(IAW) coefficient is introduced and used to modify the guidance law to make it adaptive for all guidance constraints. After integrating the closed-form solution of the guidance command with linearized engagement kinematics, the analytic predictive models of impact angle and FOV angle are built, and the available range of IAW corresponding to constraints is certain. Next, a calculation scheme is presented to acquire the real-time value of IAW during the entire guidance process. When applying the proposed guidance law, the IAW will keep small to avoid a trajectory climbing up to limit FOV angle at an initial time but will increase with the closing target to improve impact position and angle accuracy, thereby ensuring that the guidance law can juggle orders of guidance accuracy and constraints control.展开更多
Seeking in a field of view(FOV) is influenced by the existence of jammers,noise,shine background or flying perturbations.All these factors may push the target out of the FOV and cause missing the target.In all the see...Seeking in a field of view(FOV) is influenced by the existence of jammers,noise,shine background or flying perturbations.All these factors may push the target out of the FOV and cause missing the target.In all the seekers the FOV is not fully exploited which means the target can be missed before becoming out of the FOV,this results of the nonlinearity of the reticle structure.In this paper,a novel method of the target position detection a crossed four slits or crossed array trackers(CAT) seeker will be designed,simulated and evaluated.The idea of this method depends on dividing the FOV into main regions up to a certain parameter,which is the pulses number;then,each main region will be divided into sub-regions up to a second parameter which will be the pulses distribution a spin period.The errors sources will be discussed and evaluated.Other new idea will be applied which is exploiting some area of the FOV where a part of the position data is missed in the information signal by pushing the target to the region where the information signal carries the total position data.展开更多
The infrared quantum cutting of oxyfluoride nanophase vitroceramics Tb(0.7)Yb(3):FOV has been studied in the present paper. The actual quantum cutting efficiency formula calculated from integral fluorescence inte...The infrared quantum cutting of oxyfluoride nanophase vitroceramics Tb(0.7)Yb(3):FOV has been studied in the present paper. The actual quantum cutting efficiency formula calculated from integral fluorescence intensity is extended to the case of Tb(0.7)Yb(3):FOV. The visible and the infrared fluorescence spectra and their integral fluorescence intensities are measured from static fluorescence experiment. Lifetime curve is measured from dynamic fluorescence experiment. It is found that the total actual quantum cutting efficiency n of the excited 5D4 level is about 93.7%, and that of excited (5D3, 5G6) levels is 93.5%. It is also found that the total theoretical quantum cutting efficiency upper limit ?~x^Yb of the 485.5 nm excited 5D4 level is about 121.7%, and that of 378.5 nm excited (5D3, 5G6) levels is 137.2%.展开更多
Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outsi...Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm.展开更多
基金supported by the Aeronautical Science Foundation of China(20150172001)
文摘In this paper, a new adaptive optimal guidance law with impact angle and seeker’s field-of-view(FOV) angle constraints is proposed. To this end, the generalized optimal guidance law is derived first. A changeable impact angle weighting(IAW) coefficient is introduced and used to modify the guidance law to make it adaptive for all guidance constraints. After integrating the closed-form solution of the guidance command with linearized engagement kinematics, the analytic predictive models of impact angle and FOV angle are built, and the available range of IAW corresponding to constraints is certain. Next, a calculation scheme is presented to acquire the real-time value of IAW during the entire guidance process. When applying the proposed guidance law, the IAW will keep small to avoid a trajectory climbing up to limit FOV angle at an initial time but will increase with the closing target to improve impact position and angle accuracy, thereby ensuring that the guidance law can juggle orders of guidance accuracy and constraints control.
文摘Seeking in a field of view(FOV) is influenced by the existence of jammers,noise,shine background or flying perturbations.All these factors may push the target out of the FOV and cause missing the target.In all the seekers the FOV is not fully exploited which means the target can be missed before becoming out of the FOV,this results of the nonlinearity of the reticle structure.In this paper,a novel method of the target position detection a crossed four slits or crossed array trackers(CAT) seeker will be designed,simulated and evaluated.The idea of this method depends on dividing the FOV into main regions up to a certain parameter,which is the pulses number;then,each main region will be divided into sub-regions up to a second parameter which will be the pulses distribution a spin period.The errors sources will be discussed and evaluated.Other new idea will be applied which is exploiting some area of the FOV where a part of the position data is missed in the information signal by pushing the target to the region where the information signal carries the total position data.
基金supported by the National Natural Science Foundation of China (Grant No. 10674019)
文摘The infrared quantum cutting of oxyfluoride nanophase vitroceramics Tb(0.7)Yb(3):FOV has been studied in the present paper. The actual quantum cutting efficiency formula calculated from integral fluorescence intensity is extended to the case of Tb(0.7)Yb(3):FOV. The visible and the infrared fluorescence spectra and their integral fluorescence intensities are measured from static fluorescence experiment. Lifetime curve is measured from dynamic fluorescence experiment. It is found that the total actual quantum cutting efficiency n of the excited 5D4 level is about 93.7%, and that of excited (5D3, 5G6) levels is 93.5%. It is also found that the total theoretical quantum cutting efficiency upper limit ?~x^Yb of the 485.5 nm excited 5D4 level is about 121.7%, and that of 378.5 nm excited (5D3, 5G6) levels is 137.2%.
基金supported by the Tehran University of Medical Sciences under Grant No.36291PET/CT and Cyclotron Center of Masih Daneshvari Hospital at Shahid Beheshti University of Medical Sciences。
文摘Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm.