The objective of this study was to compare Magnetic Resonance Urography (MRU) with Intravenous Pyelography (IVP) in evaluation of patients with hydronephrosis on ultrasonography. 49 patients of hydronephrosis on USG w...The objective of this study was to compare Magnetic Resonance Urography (MRU) with Intravenous Pyelography (IVP) in evaluation of patients with hydronephrosis on ultrasonography. 49 patients of hydronephrosis on USG were enrolled for the study from Jan. 2011 to Dec. 2012. All patients under went Intravenous Urography (IVU). MRU was done to determine the anatomical details and function of each renal unit. MRU was performed on a 1.5 tesla unit (Magneton Avento;Siemens, Erlangen, Germany). Static T2-weighted Magnetic Resonance Urography (MRU) was performed by using a standard fast spin echo technique. Dynamic study was performed after injecting intravenous diuretic followed by Gadolinium contrast media. Morphological results of MRU were compared with IVU. The anatomical findings were compared with operative findings. Stastical analysis was performed and data expressed as mean ± SD. MRU showed PUJ obstruction in 41 out of 45 patients (91.1%). We concluded that MRU can provide complete diagnostic evaluation of entire urinary tract in a single session and has potential to replace IVP.展开更多
对几种磁测残余应力的方法和特点进行了归纳对比,它们是巴克豪森效应应力检测方法,利用逆磁致伸缩效应测量应力,利用铁磁类材料的磁记忆检测应力分布,应力致磁各向异性法SMA(Stress-induced Magnetic Anisotropy)和磁致伸缩法(Magnetost...对几种磁测残余应力的方法和特点进行了归纳对比,它们是巴克豪森效应应力检测方法,利用逆磁致伸缩效应测量应力,利用铁磁类材料的磁记忆检测应力分布,应力致磁各向异性法SMA(Stress-induced Magnetic Anisotropy)和磁致伸缩法(Magnetostriction).从目前研究现状而言,利用Barkhausen效应实施铁磁类结构构件应力检测技术相对来说最为成熟和广泛,但它有自身的缺陷,故又介绍了一台新的磁力仪MAPS,并对MAPS及其他的磁力仪作了比较.展开更多
Colorectal anastomotic leak remains one of the most feared post-operative complications, particularly after anterior resection of the rectum with, the shift from abdomino-peritoneal resections to total mesorectal exci...Colorectal anastomotic leak remains one of the most feared post-operative complications, particularly after anterior resection of the rectum with, the shift from abdomino-peritoneal resections to total mesorectal excision and primary anastomosis. The literature fails to demonstrate superiority of stapled over hand-sewn techniques in colorectal anastomosis, regardless of the level of anastomosis, although a high stricture rate was noted in the former technique. Thus, improvements in safety aspects of anastomosis and alternatives to handsewn and stapled techniques are being sought. Here, we review alternative anastomotic techniques used to fashion bowel anastomosis. Compression anastomosis using compression anastomotic clips, endoluminal compression anastomotic rings, AKA-2, biofragmental anastomotic rings, or Magnamosis all involve the concept of creating a sutureless end-to-end anastomosis by compressing two bowel ends together, leading to a simultaneous necrosis and healing process that joins the two lumens. Staple line reinforcement is a new approach that reduce the drawbacks of staplers used in colorectal practice, i.e. leakage, bleeding, misfi ring, and inadequate tissue approximation. Various nonabsorbable, semi or fully absorbable materials are now available. Two other techniques can provide alternative anastomotic support to the suture line: a colorectal drain and a polyester stent, which can be utilized in ultra-low rectal excision and can negate the formation of a defunctioning stoma. Doxycycline coated sutures have been used to overcome the post-operative weakness in anastomosis secondary to rapid matrix degradation mediated by matrix metalloproteinase. Another novel technique, the electric welding system, showed promising results in construction of a safe, neat, smooth sutureless bowel anastomosis. Various anastomotic techniques have been shown to be comparable to the standard techniques of suturing and stapling. However, most of these alternatives need to be accepted and optimized for future use.展开更多
文摘The objective of this study was to compare Magnetic Resonance Urography (MRU) with Intravenous Pyelography (IVP) in evaluation of patients with hydronephrosis on ultrasonography. 49 patients of hydronephrosis on USG were enrolled for the study from Jan. 2011 to Dec. 2012. All patients under went Intravenous Urography (IVU). MRU was done to determine the anatomical details and function of each renal unit. MRU was performed on a 1.5 tesla unit (Magneton Avento;Siemens, Erlangen, Germany). Static T2-weighted Magnetic Resonance Urography (MRU) was performed by using a standard fast spin echo technique. Dynamic study was performed after injecting intravenous diuretic followed by Gadolinium contrast media. Morphological results of MRU were compared with IVU. The anatomical findings were compared with operative findings. Stastical analysis was performed and data expressed as mean ± SD. MRU showed PUJ obstruction in 41 out of 45 patients (91.1%). We concluded that MRU can provide complete diagnostic evaluation of entire urinary tract in a single session and has potential to replace IVP.
文摘对几种磁测残余应力的方法和特点进行了归纳对比,它们是巴克豪森效应应力检测方法,利用逆磁致伸缩效应测量应力,利用铁磁类材料的磁记忆检测应力分布,应力致磁各向异性法SMA(Stress-induced Magnetic Anisotropy)和磁致伸缩法(Magnetostriction).从目前研究现状而言,利用Barkhausen效应实施铁磁类结构构件应力检测技术相对来说最为成熟和广泛,但它有自身的缺陷,故又介绍了一台新的磁力仪MAPS,并对MAPS及其他的磁力仪作了比较.
文摘Colorectal anastomotic leak remains one of the most feared post-operative complications, particularly after anterior resection of the rectum with, the shift from abdomino-peritoneal resections to total mesorectal excision and primary anastomosis. The literature fails to demonstrate superiority of stapled over hand-sewn techniques in colorectal anastomosis, regardless of the level of anastomosis, although a high stricture rate was noted in the former technique. Thus, improvements in safety aspects of anastomosis and alternatives to handsewn and stapled techniques are being sought. Here, we review alternative anastomotic techniques used to fashion bowel anastomosis. Compression anastomosis using compression anastomotic clips, endoluminal compression anastomotic rings, AKA-2, biofragmental anastomotic rings, or Magnamosis all involve the concept of creating a sutureless end-to-end anastomosis by compressing two bowel ends together, leading to a simultaneous necrosis and healing process that joins the two lumens. Staple line reinforcement is a new approach that reduce the drawbacks of staplers used in colorectal practice, i.e. leakage, bleeding, misfi ring, and inadequate tissue approximation. Various nonabsorbable, semi or fully absorbable materials are now available. Two other techniques can provide alternative anastomotic support to the suture line: a colorectal drain and a polyester stent, which can be utilized in ultra-low rectal excision and can negate the formation of a defunctioning stoma. Doxycycline coated sutures have been used to overcome the post-operative weakness in anastomosis secondary to rapid matrix degradation mediated by matrix metalloproteinase. Another novel technique, the electric welding system, showed promising results in construction of a safe, neat, smooth sutureless bowel anastomosis. Various anastomotic techniques have been shown to be comparable to the standard techniques of suturing and stapling. However, most of these alternatives need to be accepted and optimized for future use.