Cement-mixed piles,as countermeasure against liquefaction of silt and sand ground,can improve the shear strength and bearing capacity of foundation soil,meaning cement-mixed piles are capable of resisting displacement...Cement-mixed piles,as countermeasure against liquefaction of silt and sand ground,can improve the shear strength and bearing capacity of foundation soil,meaning cement-mixed piles are capable of resisting displacement when an earthquake happens. However,investigations of cement-mixed piles by experimental methods such as the shaking table test is few and far between. It is especially true for the seismic performance of cement-mixed piles in liquefiable railway foundations in high seismic intensity regions. To this end,a cross-section of the Yuxi-Mengzi railway was selected as the prototype and studied by the shaking table test in this study. The results showed that composite foundation of cementmixed piles was not liquefied when the seismic acceleration was lower than 0. 30g. In the process of acceleration increasing from 0. 30g at 2Hz to 0. 60g at 3Hz,the upper middle silt outside slope toe was partly liquefied. The foundation soil under the shoulders and center of subgrade was far from the initial liquefaction criterion during the test. Cementmixed piles can effectively reduce the embankment settlement and differential settlement. It can be concluded that, the design of cement-mixed piles can ensure the seismic performance of the subgrade,and satisfy the seismic design requirements of the YuxiMengzi railway in areas of VIII degrees seismic fortification intensity.展开更多
Continuous soil-cement wall confinement method to resist liquefaction is a new kind of process. However, whether it also has a good effect on anti-liquefaction or not needs to be urgently answered for earthquake engin...Continuous soil-cement wall confinement method to resist liquefaction is a new kind of process. However, whether it also has a good effect on anti-liquefaction or not needs to be urgently answered for earthquake engineering. Quiet boundary is adopted on the lateral face while free field boundary is employed at the bottom. Byrne model on dynamic pore water pressure generation is accepted and natural seismic wave EI Centro whose peak acceleration is adjusted to 0.2 g in proportion is used for input. A double-layer foundation with sandy soil in the upper portion while clay soil in the lower part is chosen as the calculation model, which is 30 m in length and 20 m in width. The groundwater level is on the ground surface. Excess pore water pressure rate is considered as a liquefaction index in the three-dimensional non-linear earthquake response computation. The anti-liquefaction effectiveness and its influencing factors, such as confinement element area are studied. For the natural double-layer foundation, it is liquefied when the excess pore water pressure rate reaches 1.0 under the seismic load. Under the same earthquake load, the peak excess pore water pressure reduces to 0.56 after adopting reinforcement of the continuous soil-cement wall, which is 46% lower than before. It indicates that continuous soil-cement wall confinement method can attain the purpose of anti-liquefaction. Accordingly, it can be a sort of engineering measure to carry on the anti-liquefaction foundation treatment.展开更多
Construction of seaside and underground wall bracing often uses stiffened deep cement mixed columns (SDCM). This research investigates methods used to improve the level of bearing capacity of these SDCM when subject...Construction of seaside and underground wall bracing often uses stiffened deep cement mixed columns (SDCM). This research investigates methods used to improve the level of bearing capacity of these SDCM when subjected to cyclic lateral loading via various types of stiffer cores. Eight piles, two deep cement mixed piles and six stiffened deep cement mixing piles with three different types of cores, H shape cross section prestressed concrete, steel pipe, and H-beam steel, were embedded though soft clay into medium-hard clay on site in Thailand. Cyclic horizontal loading was gradually applied until pile failure and the hysteresis loops of lateral load vs. lateral deformation were recorded. The lateral carrying capacities of the SDCM piles with an H-beam steel core increased by 3-4 times that of the DCM piles. This field research clearly shows that using H-beam steel as a stiffer core for SDCM piles is the best method to improve its lateral carrying capacity, ductility and energy dissipation capacity.展开更多
soil-cement is a mixture produced by grouting or mixing cement with soils. This paper reviews and discusses the general classifications of grouting techniques and the suitability of their applications.The mechanical p...soil-cement is a mixture produced by grouting or mixing cement with soils. This paper reviews and discusses the general classifications of grouting techniques and the suitability of their applications.The mechanical properties of soil-cement mixture and the influence of sodium silicate added are discussed. Design considerations for deep soil mixed wall(DSMW) for excavation support and vault arch for tunnelling stabilisation are presented. Parameters for the numerical analysis of soil-cement mixture are evaluated and recommended.展开更多
A series of investigations were conducted to study the bearing capacity and load transfer mechanism of stiffened deep cement mixed (SDCM) pile. Laboratory tests including six specimens were conducted to investigate ...A series of investigations were conducted to study the bearing capacity and load transfer mechanism of stiffened deep cement mixed (SDCM) pile. Laboratory tests including six specimens were conducted to investigate the frictional resistance between the concrete core and the cementsoil. Two model piles and twenty-four full-scale piles were tested to examine the bearing behavior of single pile. Laboratory and model tests results indicate that the cohesive strength is large enough to ensure the interaction between core pile and the outer cement-soil. The full-scale test results show that the SDCM piles exhibit similar bearing behavior to bored and cast-in-place concrete piles. In general, with the rational composite structure the SDCM piles can transmit the applied load effectively, and due to the addition of the stiffer core, the SDCM piles possess high bearing capacity. Based on the findings of these experimental investigations and theoretical analysi , a practical design method is developed to predict the vertical bearing capacity of SDCM pile.展开更多
Based on the idea of optimization design of pile type, the two kinds of the typical pile type are selected, which containing flexibility pile (e.g. rammed cement-soil pile is for short RCSP), and rigid pile (e.g. ceme...Based on the idea of optimization design of pile type, the two kinds of the typical pile type are selected, which containing flexibility pile (e.g. rammed cement-soil pile is for short RCSP), and rigid pile (e.g. cement-flyash-gravel pile is for short CFGP). The three kinds of the composite foundation are designed, which are CFGP, CFG long pile and CFG short pile (for short CFGLP-CFGSP), CFG long-short pile and rammed cement-soil short pile (for short CFGLP-RCSSP). Natural earthquake is simulated by using the engineering blasting;the dynamic characteristics and dynamic response of the composite foundation are studied through field test. CFGLP-RCSSP is closed to linear relation. The bearing capacity of the four composite foundation of the CFGP, CFGLP-CFGSP, and CFGLP-RCSSP in the site are 225 kPa, 179 kPa, and 197 kPa, separately increases 150%, 98.8% and 119% compared to the natural foundation. The vibration main frequency is mainly depended on properties of foundation soil and piles between vibration source and measuring point, pilling load value. Horizontal vibration main frequency greater than the vertical vibration main frequency and the vertical vibration main frequency close to the first-order natural frequency of composite foundation. With the pilling load increasing, the CFGLP-RCSSP pile composite foundation combined frequency decreased. Under the same blast energy, the acceleration peak on the CFG pile composite foundation is less than CFGLP-CFGSP the corresponding values, as the load increases, the peak acceleration gently. CFG pile composite foundation is favorable on seismic. The distribution of peak acceleration is consistent within 4 m from pile top in the CFGLP_RCSSP composite foundation. The maximum of the horizontal acceleration peak along the pile body occurs at a distance of pile top 4 m or the pile top, and that of vertical acceleration peak occurred at a pile top.展开更多
振动污染在国际上已被列入“七大环境公害”之一,填充沟是振动污染治理的一种常用隔振屏障。传统的填充沟受工程造价和施工工艺等限制工程中应用较困难;为克服上述问题,提出一种新型隔振屏障-内插预制芯墙的劲芯水泥土墙。对于饱和地基...振动污染在国际上已被列入“七大环境公害”之一,填充沟是振动污染治理的一种常用隔振屏障。传统的填充沟受工程造价和施工工艺等限制工程中应用较困难;为克服上述问题,提出一种新型隔振屏障-内插预制芯墙的劲芯水泥土墙。对于饱和地基中劲芯水泥土墙的隔振问题,饱和地基采用饱和土半解析边界元法(boundary element method,BEM)建模,劲芯水泥土墙采用有限元法(finite element method,FEM)建模,根据饱和地基-水泥土墙交界面的平衡和连续性条件,分别建立了劲芯水泥土墙对入射Rayleigh波(瑞利波)的远场被动隔振和对动力机器基础振动近场主动隔振的半解析BEM-FEM耦合分析方法,并对劲芯水泥土墙的隔振效果进行了计算分析。研究结果表明:饱和地基中设置劲芯水泥土墙能够起到较好的隔振作用,其隔振效果与混凝土墙基本相当且远优于纯水泥土墙;预制芯墙在劲芯水泥土墙隔振系统中起关键作用,为避免弹性波从芯墙底绕射而降低隔振效果,预制芯墙深度应与水泥土墙深度保持一致;增大芯墙厚度对隔振效果提升不大。在等深芯墙条件下,增大墙深能显著提高远场隔振效果,但对近场隔振效果提升较小;增大墙厚也可提高隔振效果,但提高幅度不大。实际工程中,建议结合工程造价和施工工艺,选择合适的水泥土墙和预制芯墙墙厚。此外,屏障距振源距离对主动隔振效果影响较小,建议根据被保护建筑与振源之间的实际情况,选择合适位置构建隔振屏障。展开更多
基金sponsored by the Railway's Research and Development Project of the Ministry of Railways of the People's Republic of the China:Study on Special Subgrade Construction Technology in High Intensity Earthquake Area of the Yuxi-Mengzi Railway
文摘Cement-mixed piles,as countermeasure against liquefaction of silt and sand ground,can improve the shear strength and bearing capacity of foundation soil,meaning cement-mixed piles are capable of resisting displacement when an earthquake happens. However,investigations of cement-mixed piles by experimental methods such as the shaking table test is few and far between. It is especially true for the seismic performance of cement-mixed piles in liquefiable railway foundations in high seismic intensity regions. To this end,a cross-section of the Yuxi-Mengzi railway was selected as the prototype and studied by the shaking table test in this study. The results showed that composite foundation of cementmixed piles was not liquefied when the seismic acceleration was lower than 0. 30g. In the process of acceleration increasing from 0. 30g at 2Hz to 0. 60g at 3Hz,the upper middle silt outside slope toe was partly liquefied. The foundation soil under the shoulders and center of subgrade was far from the initial liquefaction criterion during the test. Cementmixed piles can effectively reduce the embankment settlement and differential settlement. It can be concluded that, the design of cement-mixed piles can ensure the seismic performance of the subgrade,and satisfy the seismic design requirements of the YuxiMengzi railway in areas of VIII degrees seismic fortification intensity.
基金Project(50639010, 90815020) supported by the National Natural Science Foundation of ChinaProject(JKCX-200602) supported by South-to-North Water Diversion in Jiangsu Province, China
文摘Continuous soil-cement wall confinement method to resist liquefaction is a new kind of process. However, whether it also has a good effect on anti-liquefaction or not needs to be urgently answered for earthquake engineering. Quiet boundary is adopted on the lateral face while free field boundary is employed at the bottom. Byrne model on dynamic pore water pressure generation is accepted and natural seismic wave EI Centro whose peak acceleration is adjusted to 0.2 g in proportion is used for input. A double-layer foundation with sandy soil in the upper portion while clay soil in the lower part is chosen as the calculation model, which is 30 m in length and 20 m in width. The groundwater level is on the ground surface. Excess pore water pressure rate is considered as a liquefaction index in the three-dimensional non-linear earthquake response computation. The anti-liquefaction effectiveness and its influencing factors, such as confinement element area are studied. For the natural double-layer foundation, it is liquefied when the excess pore water pressure rate reaches 1.0 under the seismic load. Under the same earthquake load, the peak excess pore water pressure reduces to 0.56 after adopting reinforcement of the continuous soil-cement wall, which is 46% lower than before. It indicates that continuous soil-cement wall confinement method can attain the purpose of anti-liquefaction. Accordingly, it can be a sort of engineering measure to carry on the anti-liquefaction foundation treatment.
基金the Thailand Research Fund (TRF) for their financial support to this study
文摘Construction of seaside and underground wall bracing often uses stiffened deep cement mixed columns (SDCM). This research investigates methods used to improve the level of bearing capacity of these SDCM when subjected to cyclic lateral loading via various types of stiffer cores. Eight piles, two deep cement mixed piles and six stiffened deep cement mixing piles with three different types of cores, H shape cross section prestressed concrete, steel pipe, and H-beam steel, were embedded though soft clay into medium-hard clay on site in Thailand. Cyclic horizontal loading was gradually applied until pile failure and the hysteresis loops of lateral load vs. lateral deformation were recorded. The lateral carrying capacities of the SDCM piles with an H-beam steel core increased by 3-4 times that of the DCM piles. This field research clearly shows that using H-beam steel as a stiffer core for SDCM piles is the best method to improve its lateral carrying capacity, ductility and energy dissipation capacity.
基金financially supported by Tianjin Key Technology Development Plan(#15PTYJGX00030,KYWX-201701)
文摘soil-cement is a mixture produced by grouting or mixing cement with soils. This paper reviews and discusses the general classifications of grouting techniques and the suitability of their applications.The mechanical properties of soil-cement mixture and the influence of sodium silicate added are discussed. Design considerations for deep soil mixed wall(DSMW) for excavation support and vault arch for tunnelling stabilisation are presented. Parameters for the numerical analysis of soil-cement mixture are evaluated and recommended.
文摘A series of investigations were conducted to study the bearing capacity and load transfer mechanism of stiffened deep cement mixed (SDCM) pile. Laboratory tests including six specimens were conducted to investigate the frictional resistance between the concrete core and the cementsoil. Two model piles and twenty-four full-scale piles were tested to examine the bearing behavior of single pile. Laboratory and model tests results indicate that the cohesive strength is large enough to ensure the interaction between core pile and the outer cement-soil. The full-scale test results show that the SDCM piles exhibit similar bearing behavior to bored and cast-in-place concrete piles. In general, with the rational composite structure the SDCM piles can transmit the applied load effectively, and due to the addition of the stiffer core, the SDCM piles possess high bearing capacity. Based on the findings of these experimental investigations and theoretical analysi , a practical design method is developed to predict the vertical bearing capacity of SDCM pile.
文摘Based on the idea of optimization design of pile type, the two kinds of the typical pile type are selected, which containing flexibility pile (e.g. rammed cement-soil pile is for short RCSP), and rigid pile (e.g. cement-flyash-gravel pile is for short CFGP). The three kinds of the composite foundation are designed, which are CFGP, CFG long pile and CFG short pile (for short CFGLP-CFGSP), CFG long-short pile and rammed cement-soil short pile (for short CFGLP-RCSSP). Natural earthquake is simulated by using the engineering blasting;the dynamic characteristics and dynamic response of the composite foundation are studied through field test. CFGLP-RCSSP is closed to linear relation. The bearing capacity of the four composite foundation of the CFGP, CFGLP-CFGSP, and CFGLP-RCSSP in the site are 225 kPa, 179 kPa, and 197 kPa, separately increases 150%, 98.8% and 119% compared to the natural foundation. The vibration main frequency is mainly depended on properties of foundation soil and piles between vibration source and measuring point, pilling load value. Horizontal vibration main frequency greater than the vertical vibration main frequency and the vertical vibration main frequency close to the first-order natural frequency of composite foundation. With the pilling load increasing, the CFGLP-RCSSP pile composite foundation combined frequency decreased. Under the same blast energy, the acceleration peak on the CFG pile composite foundation is less than CFGLP-CFGSP the corresponding values, as the load increases, the peak acceleration gently. CFG pile composite foundation is favorable on seismic. The distribution of peak acceleration is consistent within 4 m from pile top in the CFGLP_RCSSP composite foundation. The maximum of the horizontal acceleration peak along the pile body occurs at a distance of pile top 4 m or the pile top, and that of vertical acceleration peak occurred at a pile top.
文摘振动污染在国际上已被列入“七大环境公害”之一,填充沟是振动污染治理的一种常用隔振屏障。传统的填充沟受工程造价和施工工艺等限制工程中应用较困难;为克服上述问题,提出一种新型隔振屏障-内插预制芯墙的劲芯水泥土墙。对于饱和地基中劲芯水泥土墙的隔振问题,饱和地基采用饱和土半解析边界元法(boundary element method,BEM)建模,劲芯水泥土墙采用有限元法(finite element method,FEM)建模,根据饱和地基-水泥土墙交界面的平衡和连续性条件,分别建立了劲芯水泥土墙对入射Rayleigh波(瑞利波)的远场被动隔振和对动力机器基础振动近场主动隔振的半解析BEM-FEM耦合分析方法,并对劲芯水泥土墙的隔振效果进行了计算分析。研究结果表明:饱和地基中设置劲芯水泥土墙能够起到较好的隔振作用,其隔振效果与混凝土墙基本相当且远优于纯水泥土墙;预制芯墙在劲芯水泥土墙隔振系统中起关键作用,为避免弹性波从芯墙底绕射而降低隔振效果,预制芯墙深度应与水泥土墙深度保持一致;增大芯墙厚度对隔振效果提升不大。在等深芯墙条件下,增大墙深能显著提高远场隔振效果,但对近场隔振效果提升较小;增大墙厚也可提高隔振效果,但提高幅度不大。实际工程中,建议结合工程造价和施工工艺,选择合适的水泥土墙和预制芯墙墙厚。此外,屏障距振源距离对主动隔振效果影响较小,建议根据被保护建筑与振源之间的实际情况,选择合适位置构建隔振屏障。