In the research and development of new silicon pixel detectors,a collimated monoenergetic charged-particle test beam equipped with a high-resolution pixel-beam telescope is crucial for prototype verification and perfo...In the research and development of new silicon pixel detectors,a collimated monoenergetic charged-particle test beam equipped with a high-resolution pixel-beam telescope is crucial for prototype verification and performance evaluation.When the beam energy is low,the effect of multiple Coulomb scattering on the measured resolution of the Device Under Test(DUT)must be considered to accurately evaluate the performance of the pixel chips and detectors.This study aimed to investigate the effect of multiple Coulomb scattering on the measured resolution,particularly at low beam energies.Simulations were conducted using Allpix^(2) to study the effects of multiple Coulomb scattering under different beam energies,material budgets,and telescope layouts.The simulations also provided the minimum energy at which the effect of multiple Coulomb scattering could be ignored.Compared with the results of a five-layer detector system tested with an electron beam at DESY,the simulation results were consistent with the beam test results,confirming the reliability of the simulations.展开更多
Carbon ions,commonly referred to as particle therapy,have become increasingly popular in the last decade.Accurately predicting the range of ions in tissues is important for the precise delivery of doses in heavy-ion r...Carbon ions,commonly referred to as particle therapy,have become increasingly popular in the last decade.Accurately predicting the range of ions in tissues is important for the precise delivery of doses in heavy-ion radiotherapy.Range uncertainty is currently the largest contributor to dose uncertainty in normal tissues,leading to the use of safety margins in treatment planning.One potential method is the direct relative stopping measurement(RSP)with ions.Heavy-ion CT(Hi′CT),a compact segmented full digital tomography detector using monolithic active pixel sensors,was designed and evaluated using a 430 MeV/u high-energy carbon ion pencil beam in Geant4.The precise position of the individual carbon ion track can be recorded and reconstructed using a 30μm×30μm small pixel pitch size.Two types of customized image reconstruction algorithms were developed,and their performances were evaluated using three different modules of CAT-PHAN 600-series phantoms.The RSP measurement accuracy of the tracking algorithm for different types of materials in the CTP404 module was less than 1%.In terms of spatial resolution,the tracking algorithm could achieve a 20%modulation transfer function normalization value of CTP528 imaging results at 5 lp/cm,which is significantly better than that of the fast imaging algorithm(3 lp/cm).The density resolution obtained using the tracking algorithm of the customized CTP515 was approximately 10.5%.In conclusion,a compact digital Hi'CT system was designed,and its nominal performance was evaluated in a simulation.The RSP resolution and image quality provide potential feasibility for scanning most parts of an adult body or pediatric patient,particularly for head and neck tumor treatment.展开更多
Lanthanum bromide(LaBr_(3))crystal has a high energy resolution and time resolution and has been used in Compton cameras(CCs)over the past few decades.However,LaBr_(3) crystal arrays are difficult to process because L...Lanthanum bromide(LaBr_(3))crystal has a high energy resolution and time resolution and has been used in Compton cameras(CCs)over the past few decades.However,LaBr_(3) crystal arrays are difficult to process because LaBr_(3) is easy to crack and break;thus,few LaBr_(3)-based CC prototypes have been built.In this study,we designed and fabricated a large-pixel LaBr_(3) CC prototype and evaluated its performance with regard to position,energy,and angular resolution.We used two 10×10 LaBr_(3) crystal arrays with a pixel size of 5 mm×5 mm,silicon photomultipliers(SiPMs),and corresponding decoding circuits to construct our prototype.Additionally,a framework based on a Voronoi diagram and a lookup table was developed for list-mode projection data acquisition.Monte Carlo(MC)simulations based on Geant4 and experiments were conducted to evaluate the performance of our CC prototype.The lateral position resolution was 5 mm,and the maximum deviation in the depth direction was 2.5 and 5 mm for the scatterer and absorber,respectively.The corresponding measured energy resolu-tions were 7.65%and 8.44%,respectively,at 511 keV.The experimental results of ^(137)Cs point-like sources were consistent with the MC simulation results with regard to the spatial positions and full widths at half maximum(FWHMs).The angular resolution of the fabricated prototype was approximately 6°when a point-like ^(137)Cs source was centrally placed at a distance of 5 cm from the scatterer.We proposed and investigated a large-pixel LaBr_(3) CC for the first time and verified its feasibility for use in accurate spatial positioning of radiative sources with a high angular resolution.The proposed CC can satisfy the requirements of radiative source imaging and positioning in the nuclear industry and medical applications.展开更多
The reconstruction of the tracks of charged particles with high precision is crucial for HEP experiments to achieve their physics goals.The BESⅢdrift chamber,which is used as the tracking detector of the BESⅢexperim...The reconstruction of the tracks of charged particles with high precision is crucial for HEP experiments to achieve their physics goals.The BESⅢdrift chamber,which is used as the tracking detector of the BESⅢexperiment,has suffered from aging effects resulting in degraded tracking performance after operation for approximately 15 years.To preserve and enhance the tracking performance of BESⅢ,one of the proposals is to add one layer of a thin cylindrical CMOS pixel sensor based on state-of-the-art stitching technology between the beam pipe and the drift chamber.The improvement in the tracking performance of BESⅢwith such an additional pixel detector compared to that with only the existing drift chamber was studied using the modern common tracking software Acts,which provides a set of detector-agnostic and highly performant tracking algorithms that have demonstrated promising performance for a few high-energy physics and nuclear physics experiments.展开更多
Based on the analysis to the behavior of bad pixels, a statistics-based auto-detecting and compensation algorithm for bad pixels is proposed. The correcting process is divided into two stages: bad pixel detection and...Based on the analysis to the behavior of bad pixels, a statistics-based auto-detecting and compensation algorithm for bad pixels is proposed. The correcting process is divided into two stages: bad pixel detection and bad pixel compensation. The proposed detection algorithm is a combination of median filtering and statistic method. Single frame median filtering is used to locate approximate map, then statistic method and threshold value is used to get the accurate location map of bad pixels. When the bad pixel detection is done, neighboring pixel replacement algorithm is used to compensate them in real-time. The effectiveness of this approach is test- ed by applying it to I-IgCATe infrared video. Experiments on real infrared imaging sequences demonstrate that the proposed algorithm requires only a few frames to obtain high quality corrections. It is easy to combine with traditional static methods, update the pre-defined location map in real-time.展开更多
This paper introduces certain innovative algorithms to mask for pixel defects seen in image sensors. Pixel defectivity rates scale with pixel architecture and process nodes. Smaller pixel and process nodes introduce m...This paper introduces certain innovative algorithms to mask for pixel defects seen in image sensors. Pixel defectivity rates scale with pixel architecture and process nodes. Smaller pixel and process nodes introduce more defects in manufacturing. Brief introduction to causes for pixel defectivity at lower pixel nodes is explained. Later in the paper, popular defect correction schemes used in image processing applications are discussed. A new approach for defect correction is presented and evaluated using images captured from an 8M Bayer image sensor. Experimentation for threshold evaluation is done and presented with practical results for better optimization of proposed algorithms. Experimental data shows that proposed defect corrections preserves a lot of edge details and corrects for bright and hot pixels/clusters, which are evaluated using histogram analysis.展开更多
After approximately half a century of development, HgCdTe infrared detectors have become the first choice for high performance infrared detectors, which are widely used in various industry sectors, including military ...After approximately half a century of development, HgCdTe infrared detectors have become the first choice for high performance infrared detectors, which are widely used in various industry sectors, including military tracking, military reconnaissance, infrared guidance, infrared warning, weather forecasting, and resource detection. Further development in infrared applications requires future HgCdTe infrared detectors to exhibit features such as larger focal plane array format and thus higher imaging resolution. An effective approach to develop HgCdTe infrared detectors with a larger array format size is to develop the small pixel technology. In this article, we present a review on the developmental history and current status of small pixel technology for HgCdTe infrared detectors, as well as the main challenges and potential solutions in developing this technology. It is predicted that the pixel size of long-wave HgCdTe infrared detectors can be reduced to5 μm, while that of mid-wave HgCdTe infrared detectors can be reduced to 3 μm. Although significant progress has been made in this area, the development of small pixel technology for HgCdTe infrared detectors still faces significant challenges such as flip-chip bonding, interconnection, and charge processing capacity of readout circuits. Various approaches have been proposed to address these challenges, including three-dimensional stacking integration and readout circuits based on microelectromechanical systems.展开更多
The 12 May 2008 Wenchuan Ms8.0 earthquake produced surface displacements along the causative fault, the Yingxiu-Beichuan Fault, which are up to several meters near the fault. Because of the large gradient, satellite s...The 12 May 2008 Wenchuan Ms8.0 earthquake produced surface displacements along the causative fault, the Yingxiu-Beichuan Fault, which are up to several meters near the fault. Because of the large gradient, satellite synthetic aperture radar (SAR) interferometric data are strongly incoherent; the usual SAR interferometry method does not allow such displacements to be measured. In the present study, we employed another approach, the technique based on pixel offset tracking, to solve this problem. The used image data of six tracks are from the Advanced Land Observing Satellite, Phased Array type L-band Synthetic Aperture Radar (ALOS/PALSAR) dataset of Japan. The results show that the entire surface rupture belt is 238 km long, extending almost linearly in a direction of 42°north-east. It is offset left laterally by a north-west-striking fault at Xiaoyudong, and turns at Gaochuan, where the rupture belt shifts toward the south by 5 km, largely keeping the original trend. In terms of the features of the rupture traces, the rupture belt can be divided into five sections and three types. Among them, the Beichuan-Chaping and Hongkou-Yingxiu sections are relatively complex, with large widths and variable traces along the trend. The Pingtong-Nanba and Qingping-Jingtang sections appear uniform, characterized by straight traces and small widths. West of Yingxiu, the rupture traces are not clear. North of the rupture belt, surface displacements are 2.95 m on average, mostly 2-3.5 m, with 7-9 m the maximum near Beichuan. South of the rupture belt, the average displacement is 1.75 m, dominated by 1-2 m, with 3-4 m at a few sites. In the north, the displacements in the radar line of sight are of subsidence, and in the south, they are uplifted, in accordance with a right-slip motion that moves the northern wall of the fault to the east, and the southern wall to the west, respectively. Along the Guanxian-Jiangyou Fault, there is a uplift zone in the radar line of sight, which is 66 km long, 1.5-6 km wide, and has vertical displacements of approximately 2 m, but no observable rupture traces.展开更多
In this paper, we study how pixel size influences energy resolution for a proposed pixelated detector—a high sensitivity, low cost, and real-time radon monitor based on a Topmetal-Ⅱ^- time projection chamber(TPC). T...In this paper, we study how pixel size influences energy resolution for a proposed pixelated detector—a high sensitivity, low cost, and real-time radon monitor based on a Topmetal-Ⅱ^- time projection chamber(TPC). This monitor was designed to improve spatial resolution for detecting radon alpha particles using Topmetal-Ⅱ^- sensors assembled by a 0.35 lm CMOS integrated circuit process.Owing to concerns that small pixel size might have the side effect of worsening energy resolution due to lower signalto-noise ratio, a Geant4-based simulation was used to investigate the dependence of energy resolution on pixel sizes ranging from 60 to 600 lm. A non-monotonic trend in this region shows the combined effect of pixel size and threshold on pixels, analyzed by introducing an empirical expression. Pixel noise contributes 50 keV full-width at half-maximum energy resolution for 400 lm pixel size at 1–4σ threshold that is comparable to the energy resolution caused by energy fluctuations in the TPC ionization process( ~20 keV). The total energy resolution after combining both factors is estimated to be 54 keV for a pixel size of 400 lm at 1–4σ threshold. The analysis presented in this paper would help choosing suitable pixel size for future pixelated detectors.展开更多
基金supported by the National Natural Science Foundation of China(Nos.11875274 and U1232202)。
文摘In the research and development of new silicon pixel detectors,a collimated monoenergetic charged-particle test beam equipped with a high-resolution pixel-beam telescope is crucial for prototype verification and performance evaluation.When the beam energy is low,the effect of multiple Coulomb scattering on the measured resolution of the Device Under Test(DUT)must be considered to accurately evaluate the performance of the pixel chips and detectors.This study aimed to investigate the effect of multiple Coulomb scattering on the measured resolution,particularly at low beam energies.Simulations were conducted using Allpix^(2) to study the effects of multiple Coulomb scattering under different beam energies,material budgets,and telescope layouts.The simulations also provided the minimum energy at which the effect of multiple Coulomb scattering could be ignored.Compared with the results of a five-layer detector system tested with an electron beam at DESY,the simulation results were consistent with the beam test results,confirming the reliability of the simulations.
基金the National Natural Science Foundation of China(Nos.11975292,12205374,U2032209,and 12222512)Beijing Hope Run Special Fund of Cancer Foundation of China(No.LC2021B23)+1 种基金the CAS“Light of West China”Program,the CAS Pioneer Hundred Talent Program,the Guangdong Major Project of Basic and Applied Basic Research(No.2020B0301030008)the National Key Research and Development Program of China(No.2021YFA1601300 and 2020YFE0202002).
文摘Carbon ions,commonly referred to as particle therapy,have become increasingly popular in the last decade.Accurately predicting the range of ions in tissues is important for the precise delivery of doses in heavy-ion radiotherapy.Range uncertainty is currently the largest contributor to dose uncertainty in normal tissues,leading to the use of safety margins in treatment planning.One potential method is the direct relative stopping measurement(RSP)with ions.Heavy-ion CT(Hi′CT),a compact segmented full digital tomography detector using monolithic active pixel sensors,was designed and evaluated using a 430 MeV/u high-energy carbon ion pencil beam in Geant4.The precise position of the individual carbon ion track can be recorded and reconstructed using a 30μm×30μm small pixel pitch size.Two types of customized image reconstruction algorithms were developed,and their performances were evaluated using three different modules of CAT-PHAN 600-series phantoms.The RSP measurement accuracy of the tracking algorithm for different types of materials in the CTP404 module was less than 1%.In terms of spatial resolution,the tracking algorithm could achieve a 20%modulation transfer function normalization value of CTP528 imaging results at 5 lp/cm,which is significantly better than that of the fast imaging algorithm(3 lp/cm).The density resolution obtained using the tracking algorithm of the customized CTP515 was approximately 10.5%.In conclusion,a compact digital Hi'CT system was designed,and its nominal performance was evaluated in a simulation.The RSP resolution and image quality provide potential feasibility for scanning most parts of an adult body or pediatric patient,particularly for head and neck tumor treatment.
文摘Lanthanum bromide(LaBr_(3))crystal has a high energy resolution and time resolution and has been used in Compton cameras(CCs)over the past few decades.However,LaBr_(3) crystal arrays are difficult to process because LaBr_(3) is easy to crack and break;thus,few LaBr_(3)-based CC prototypes have been built.In this study,we designed and fabricated a large-pixel LaBr_(3) CC prototype and evaluated its performance with regard to position,energy,and angular resolution.We used two 10×10 LaBr_(3) crystal arrays with a pixel size of 5 mm×5 mm,silicon photomultipliers(SiPMs),and corresponding decoding circuits to construct our prototype.Additionally,a framework based on a Voronoi diagram and a lookup table was developed for list-mode projection data acquisition.Monte Carlo(MC)simulations based on Geant4 and experiments were conducted to evaluate the performance of our CC prototype.The lateral position resolution was 5 mm,and the maximum deviation in the depth direction was 2.5 and 5 mm for the scatterer and absorber,respectively.The corresponding measured energy resolu-tions were 7.65%and 8.44%,respectively,at 511 keV.The experimental results of ^(137)Cs point-like sources were consistent with the MC simulation results with regard to the spatial positions and full widths at half maximum(FWHMs).The angular resolution of the fabricated prototype was approximately 6°when a point-like ^(137)Cs source was centrally placed at a distance of 5 cm from the scatterer.We proposed and investigated a large-pixel LaBr_(3) CC for the first time and verified its feasibility for use in accurate spatial positioning of radiative sources with a high angular resolution.The proposed CC can satisfy the requirements of radiative source imaging and positioning in the nuclear industry and medical applications.
基金supported by the National Natural Science Foundation of China(Nos.U2032203,12275296,12275297,12075142,12175256,12035009)National Key R&D Program of China(No.2020YFA0406302)。
文摘The reconstruction of the tracks of charged particles with high precision is crucial for HEP experiments to achieve their physics goals.The BESⅢdrift chamber,which is used as the tracking detector of the BESⅢexperiment,has suffered from aging effects resulting in degraded tracking performance after operation for approximately 15 years.To preserve and enhance the tracking performance of BESⅢ,one of the proposals is to add one layer of a thin cylindrical CMOS pixel sensor based on state-of-the-art stitching technology between the beam pipe and the drift chamber.The improvement in the tracking performance of BESⅢwith such an additional pixel detector compared to that with only the existing drift chamber was studied using the modern common tracking software Acts,which provides a set of detector-agnostic and highly performant tracking algorithms that have demonstrated promising performance for a few high-energy physics and nuclear physics experiments.
基金Sponsored by the National Natural Science Foundation of China(60877060)
文摘Based on the analysis to the behavior of bad pixels, a statistics-based auto-detecting and compensation algorithm for bad pixels is proposed. The correcting process is divided into two stages: bad pixel detection and bad pixel compensation. The proposed detection algorithm is a combination of median filtering and statistic method. Single frame median filtering is used to locate approximate map, then statistic method and threshold value is used to get the accurate location map of bad pixels. When the bad pixel detection is done, neighboring pixel replacement algorithm is used to compensate them in real-time. The effectiveness of this approach is test- ed by applying it to I-IgCATe infrared video. Experiments on real infrared imaging sequences demonstrate that the proposed algorithm requires only a few frames to obtain high quality corrections. It is easy to combine with traditional static methods, update the pre-defined location map in real-time.
文摘This paper introduces certain innovative algorithms to mask for pixel defects seen in image sensors. Pixel defectivity rates scale with pixel architecture and process nodes. Smaller pixel and process nodes introduce more defects in manufacturing. Brief introduction to causes for pixel defectivity at lower pixel nodes is explained. Later in the paper, popular defect correction schemes used in image processing applications are discussed. A new approach for defect correction is presented and evaluated using images captured from an 8M Bayer image sensor. Experimentation for threshold evaluation is done and presented with practical results for better optimization of proposed algorithms. Experimental data shows that proposed defect corrections preserves a lot of edge details and corrects for bright and hot pixels/clusters, which are evaluated using histogram analysis.
文摘After approximately half a century of development, HgCdTe infrared detectors have become the first choice for high performance infrared detectors, which are widely used in various industry sectors, including military tracking, military reconnaissance, infrared guidance, infrared warning, weather forecasting, and resource detection. Further development in infrared applications requires future HgCdTe infrared detectors to exhibit features such as larger focal plane array format and thus higher imaging resolution. An effective approach to develop HgCdTe infrared detectors with a larger array format size is to develop the small pixel technology. In this article, we present a review on the developmental history and current status of small pixel technology for HgCdTe infrared detectors, as well as the main challenges and potential solutions in developing this technology. It is predicted that the pixel size of long-wave HgCdTe infrared detectors can be reduced to5 μm, while that of mid-wave HgCdTe infrared detectors can be reduced to 3 μm. Although significant progress has been made in this area, the development of small pixel technology for HgCdTe infrared detectors still faces significant challenges such as flip-chip bonding, interconnection, and charge processing capacity of readout circuits. Various approaches have been proposed to address these challenges, including three-dimensional stacking integration and readout circuits based on microelectromechanical systems.
基金supported by the State Key Laboratory of Earthquake Dynamics,Institute of Geology,China Earthquake Administration(CEA) (no. LED2010A02,LED2008A06)
文摘The 12 May 2008 Wenchuan Ms8.0 earthquake produced surface displacements along the causative fault, the Yingxiu-Beichuan Fault, which are up to several meters near the fault. Because of the large gradient, satellite synthetic aperture radar (SAR) interferometric data are strongly incoherent; the usual SAR interferometry method does not allow such displacements to be measured. In the present study, we employed another approach, the technique based on pixel offset tracking, to solve this problem. The used image data of six tracks are from the Advanced Land Observing Satellite, Phased Array type L-band Synthetic Aperture Radar (ALOS/PALSAR) dataset of Japan. The results show that the entire surface rupture belt is 238 km long, extending almost linearly in a direction of 42°north-east. It is offset left laterally by a north-west-striking fault at Xiaoyudong, and turns at Gaochuan, where the rupture belt shifts toward the south by 5 km, largely keeping the original trend. In terms of the features of the rupture traces, the rupture belt can be divided into five sections and three types. Among them, the Beichuan-Chaping and Hongkou-Yingxiu sections are relatively complex, with large widths and variable traces along the trend. The Pingtong-Nanba and Qingping-Jingtang sections appear uniform, characterized by straight traces and small widths. West of Yingxiu, the rupture traces are not clear. North of the rupture belt, surface displacements are 2.95 m on average, mostly 2-3.5 m, with 7-9 m the maximum near Beichuan. South of the rupture belt, the average displacement is 1.75 m, dominated by 1-2 m, with 3-4 m at a few sites. In the north, the displacements in the radar line of sight are of subsidence, and in the south, they are uplifted, in accordance with a right-slip motion that moves the northern wall of the fault to the east, and the southern wall to the west, respectively. Along the Guanxian-Jiangyou Fault, there is a uplift zone in the radar line of sight, which is 66 km long, 1.5-6 km wide, and has vertical displacements of approximately 2 m, but no observable rupture traces.
基金supported by the National Natural Science Foundation of China(No.U1732271)
文摘In this paper, we study how pixel size influences energy resolution for a proposed pixelated detector—a high sensitivity, low cost, and real-time radon monitor based on a Topmetal-Ⅱ^- time projection chamber(TPC). This monitor was designed to improve spatial resolution for detecting radon alpha particles using Topmetal-Ⅱ^- sensors assembled by a 0.35 lm CMOS integrated circuit process.Owing to concerns that small pixel size might have the side effect of worsening energy resolution due to lower signalto-noise ratio, a Geant4-based simulation was used to investigate the dependence of energy resolution on pixel sizes ranging from 60 to 600 lm. A non-monotonic trend in this region shows the combined effect of pixel size and threshold on pixels, analyzed by introducing an empirical expression. Pixel noise contributes 50 keV full-width at half-maximum energy resolution for 400 lm pixel size at 1–4σ threshold that is comparable to the energy resolution caused by energy fluctuations in the TPC ionization process( ~20 keV). The total energy resolution after combining both factors is estimated to be 54 keV for a pixel size of 400 lm at 1–4σ threshold. The analysis presented in this paper would help choosing suitable pixel size for future pixelated detectors.