Evaluation of the bone metabolism balance and traumatic reaction of minimally invasive mippo intramedullary nail internal fixation treatment of femoral shaft fractures 被引量:1
1
作者 Min Gu Jian Ji Xiong Fan 《Journal of Hainan Medical University》 2017年第13期83-86,共4页
Objective:To evaluate the bone metabolism balance and traumatic reaction of minimally invasive mippo intramedullary nail internal fixation treatment of femoral shaft fractures. Methods:80 patients with femoral shaft f... Objective:To evaluate the bone metabolism balance and traumatic reaction of minimally invasive mippo intramedullary nail internal fixation treatment of femoral shaft fractures. Methods:80 patients with femoral shaft fractures who were treated in our hospital between May 2011 and December 2016 were collected and divided into control group (n=40) and observation group (n=40) according to random number table, control group received conventional steel plate internal fixation treatment, and observation group received minimally invasive mippo intramedullary nail internal fixation treatment. Differences in serum levels of bone formation indexes, bone resorption indexes, inflammatory factors, and pain mediators and so on were compared between two groups of patients before operation and 1 week after treatment.Results: Before operation, differences in serum levels of bone formation indexes, bone resorption indexes, inflammatory factors and pain mediators were not statistically significant between two groups of patients. After operation, serum bone formation indexes P ICP, BGP, BALP and ALP levels in observation group were higher than those in control group;serum bone resorption indexesβ-CTX and OPG levels were lower than those in control group;serum inflammatory factors IL-1β, IL-6, IL-8 and CRP levels were lower than those in control group;serum pain mediators SP, PGE2 and 5-HT levels were lower than those in control group.Conclusion:Minimally invasive mippo intramedullary nail internal fixation treatment of femoral shaft fractures can promote the bone formation, relatively inhibit bone resorption and cause less traumatic reaction. 展开更多
关键词 FEMORAL shaft fractures MINIMALLY invasive MIPPO intramedullary NAIL Bone metabolism Inflammatory response Pain MEDIATOR
下载PDF
Bone metabolism and trauma degree of magnetic-guided intramedullary nail fixation for femoral shaft fracture
2
作者 Hong-Wei Yan Liang-Zhi Xu Cai-Xia Ma 《Journal of Hainan Medical University》 2018年第14期34-37,共4页
Objective:To explore the effect of magnetic-guided intramedullary nail fixation on bone metabolism and trauma degree in patients with femoral shaft fracture.Methods: A total of 128 patients with femoral shaft fracture... Objective:To explore the effect of magnetic-guided intramedullary nail fixation on bone metabolism and trauma degree in patients with femoral shaft fracture.Methods: A total of 128 patients with femoral shaft fractures who received surgical treatment in the hospital between April 2016 and November 2017 were divided into control group (n=64) and study group (n=64) according to the random number table method. Control group received the traditional intramedullary nail treatment, and study group received magnetic-guided intramedullary nail treatment. The differences in serum levels of bone metabolism indexes and inflammatory factors were compared between the two groups 48 h after surgery.Results: 48 h after surgery, serum bone formation indexes BGP, PⅠNP, PⅠCP and BAP levels of study group were higher than those of control group whereas bone resorption indexesβ-CTX, TRACP5b and NTX levels were lower than those of control group;serum inflammatory factors TGF-β, hs-CRP, IL-1β, IL-6 and IL-17 levels were lower than those of control group.Conclusion:Compared with traditional intramedullary nail therapy, magnetic-guided intramedullary nail fixation can more effectively balance the bone metabolism status and reduce the fracture end trauma in patients with femoral shaft fracture. 展开更多
关键词 FEMORAL shaft fracture Magnetic-guided intramedullary NAIL fixation Bone metabolism TRAUMA
下载PDF
Trauma and bone metabolism of magnetic navigation intramedullary nail and traditional intramedullary nail fixation treatment of femoral shaft fracture
3
作者 Shao-Hui Zhang 《Journal of Hainan Medical University》 2017年第3期96-100,共5页
Objective:To analyze the trauma and bone metabolism of magnetic navigation intramedullary nail and traditional intramedullary nail fixation treatment of femoral shaft fracture. Methods:58 patients with femoral shaft f... Objective:To analyze the trauma and bone metabolism of magnetic navigation intramedullary nail and traditional intramedullary nail fixation treatment of femoral shaft fracture. Methods:58 patients with femoral shaft fracture treated in our hospital between December 2011 and December 2015 were divided into observation group and control group by random number table (n=29). Control group received conventional intramedullary nail fixation treatment, and observation group received magnetic navigation intramedullary nail fixation treatment. 24 h after surgery, blood coagulation indexes, enzymology indexes, bone metabolism indexes and angiogenesis indexes were determined;6 months after surgery, bone mineral density levels were determined. Results:24 h after surgery, peripheral blood thrombin time (TT), prothrombin time (PT), and activated partial thromboplastin time (APTT) levels of observation group were significantly higher than those of control group, and serum fibrinogen (FIB), D-Dimer (D-D), lactate dehydrogenase (LDH), creatine kinase (CK), creatine kinase isoenzyme (CKMB), glutamic oxalacetic transaminase (GOT), sex hormone-binding globulin type I (SHBG), collagen cross-linked carboxyl-terminal telopeptide (CTX) and deoxypyridinoline (DPD) content were lower than those of control group while bone gla protein (BGP), insulin-like growth factor (IGF-1), hypoxia-inducible factor-1α (HIF-α), angiogenin 1 (Ang-1), recombinant basic fibroblast growth factor (bFGF) and vascular endothelial growth factor (VEGF) content were higher than those of control group;6 months after surgery, fracture end bone mineral density (BMD) value of observation group was higher than that of control group. Conclusions:Magnetic navigation intramedullary nail treatment of femoral shaft fracture can more effectively reduce the surgical trauma, improve bone metabolism and increase bone mineral density. 展开更多
关键词 FEMORAL SHAFT fracture Magnetic navigation intramedullary NAIL for FEMORAL SHAFT fracture Traditional intramedullary NAIL fixation TRAUMA Bone metabolism
下载PDF
Treatment of femur supracondylar fracture with retrograde interlocking intramedullary nails in elderly patients
4
作者 Yiheng Liu Haiying Zhang +1 位作者 Hongmin Zang Junchang Cheng 《Journal of Nanjing Medical University》 2006年第3期160-161,共2页
Objective: To report 32 cases of femur supracondylar fracture treated with retrograde interlocking intramedullary nails in elderly patients. Methods: According to the AO classification, all of 32 cases were classifi... Objective: To report 32 cases of femur supracondylar fracture treated with retrograde interlocking intramedullary nails in elderly patients. Methods: According to the AO classification, all of 32 cases were classified as extra-articular type A. 32 cases were treated with interlocking intramedullary nail by closed insertion from intercondylar fossa of the knee. All cases accepted CPM exercise as early as possible after operation. Results: Following up 5 to 15 months, all fractures united within an average duration of 5.3 months (4-7 months). According to the Shelbourne scale, the excellent rate of the knee function was 86.3%. Conclusion: Retrograde interlocking intramedullary nail is useful alternative implant for the treatment of osteoporotic supracondylar fracture of femur, particularly of the type A fracture in the elderly population. Its merits include stable fixation, high rate of fracture union and few complications. 展开更多
关键词 femur supracondylar fracture interlocking intramedullary nails fracture fixation
下载PDF
The effect of rectangular elastic intramedullary nail treatment plus postsurgery rehabilitation exercises on the function restoration of knee and ankle joint in fracture of tibia and fibula
5
作者 牛子全 《中国组织工程研究与临床康复》 CAS CSCD 2001年第24期154-,共1页
关键词 The effect of rectangular elastic intramedullary nail treatment plus postsurgery rehabilitation exercises on the function restoration of knee and ankle joint in fracture of tibia and fibula
下载PDF
Indirect Reduction and Intramedullary Pinning in Severely Displaced Radial Neck Fractures in Children 被引量:1
6
作者 Ashish Devgan Raj Singh +3 位作者 Suresh Kumar Vinit Verma NK Magu RC Siwach 《International Journal of Clinical Medicine》 2011年第2期75-78,共4页
Fractures of the radial neck account for 5-10% of traumatic lesions of the elbow in the child. Conservative method of reduction may fail to reduce severely displaced fractures. Open reduction of severely displaced rad... Fractures of the radial neck account for 5-10% of traumatic lesions of the elbow in the child. Conservative method of reduction may fail to reduce severely displaced fractures. Open reduction of severely displaced radial neck fractures is associated with a high incidence of complications. The present study describes the results achieved after closed and indirect reduction of the severely displaced radial head using a 2-mm K-wire passed intramedullary from near the radial styloid. The bent tip of the K-wire was used to manipulate the displaced head back to the shaft without opening the fracture site. The indirect reduction of the radial head using bent intramedullary K-wire is a simple, minimally invasive method, easy to perform, and obtains encouraging results with few complications. Intramedullary pin also achieves fixation of the radial head after reduction and prevents its secondary displacement. 展开更多
关键词 intramedullary PINNING RADIAL NECK fracture
下载PDF
Minimally invasive treatment of forearm double fracture in adult using Acumed forearm intramedullary nail: A case report 被引量:1
7
作者 Ji-Chao Liu Bing-Zhe Huang +3 位作者 Jie Ding Xiao-Jia Mu Yun-Long Li Cheng-Dong Piao 《World Journal of Clinical Cases》 SCIE 2021年第11期2595-2601,共7页
BACKGROUND Currently,open reduction internal fixation is the conventional surgical method for treatment of double ulna and radius fracture.However,open reduction is associated with a high risk of complications.This ca... BACKGROUND Currently,open reduction internal fixation is the conventional surgical method for treatment of double ulna and radius fracture.However,open reduction is associated with a high risk of complications.This case of forearm double fracture involved a patient treated using an Acumed intramedullary nail.The patient experienced good follow-up outcomes.The Acumed forearm intramedullary nail enables early functional exercise and hastens healing of the fracture.Few studies have reported on the use of this approach for the treatment of fractures.CASE SUMMARY A 23-year-old male patient was admitted to hospital after 5 h of pain,swelling,and limited activity of left forearm caused by a careless fall.Physical examination showed stable basic vital signs,swelling of the left forearm,and severe pain when pressing on the injured part of the forearm.Further,friction was felt at the broken end of the bone;the skin was not punctured.Movement of the left hand was normal,and the left radial artery pulse was normal.Three-dimensional computed tomography examination showed an ulna fracture of the left forearm and comminuted fracture of the radius.The fracture was located in the upper third of the radius,with significant displacement on the fracture side.Clinical diagnosis further confirmed the left radius comminuted fracture and ulna fracture.After analyzing the fracture pattern,age,and other patient characteristics,we chose an Acumed nail for treatment and achieved good follow-up outcomes.CONCLUSION Acumed forearm intramedullary nail for fixation of ulna and radius fracture reduced complication risk and resulted in good follow-up outcomes. 展开更多
关键词 intramedullary nail Forearm double fracture Minimally invasive approach Delayed fracture healing Soft tissue injury Case report
下载PDF
Risk Assessment of Retrograde Intramedullary Nailing for Proximal Humeral Fracture
8
作者 Rina Sakai Uchino Masataka +1 位作者 Kazuhiro Yoshida Masanobu Ujihira 《Journal of Biomedical Science and Engineering》 2019年第5期277-284,共8页
In proximal humeral fracture except AO classification 11A1, fixations with a locking plate and nails are recommended. We performed mechanical tests to investigate whether retrograde intramedullary nailing has fixation... In proximal humeral fracture except AO classification 11A1, fixations with a locking plate and nails are recommended. We performed mechanical tests to investigate whether retrograde intramedullary nailing has fixation stability comparable to those of anterograde intramedullary nailing and locking plate which achieve clinically favorable outcomes. In retrograde intramedullary nailing, a nail entry point is made in the diaphysis, for which reduction of stiffness of the humerus is of concern. Thus, we investigated the influence of a nail entry point made in the diaphysis on humeral strength. Retrograde intramedullary nailing had fixation stability against bending and a force loaded in the rotation direction comparable to those of anterograde intramedullary nail and locking plate. Displacement by the main external force loaded on the humerus, compressive load, was less than half in the bone fixed by retrograde intramedullary nailing compared with that in the bone fixed with a locking plate, showing favorable fixation stability. It was clarified that stiffness of the humerus against rotation and a load in the compression direction is not reduced by a nail entry point made by retrograde intramedullary nailing. 展开更多
关键词 PROXIMAL HUMERAL fracture RETROGRADE intramedullary NAILING ANTEROGRADE intramedullary NAILING Locking Plate Internal fixation
下载PDF
Finite Element Analysis Study of Prototype of a Novel Intramedullary Injectable Bioresorbable Polymer Fixator versus a Volar Plate for Surgical Treatment of Distal Radius Fractures
9
作者 Adam Zysk Gladius Lewis 《World Journal of Engineering and Technology》 2017年第4期648-667,共20页
Complications and shortcomings of volar plating, which is very widely used for surgical treatment of distal radius fractures, are well known. Thus, there is scope for alternative innovative surgical methods. In the pr... Complications and shortcomings of volar plating, which is very widely used for surgical treatment of distal radius fractures, are well known. Thus, there is scope for alternative innovative surgical methods. In the present work, we used the finite element analysis method to compare the biomechanical performance of a model of a construct comprising a simulated distal radius fracture considered fixated using a notional intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis system (“fixator”) versus using a commercially-available volar locking plate (VP). The biomechanical parameters determined were longitudinal stiffness and factor of safety under each of the applied loads.?For the fixator model, 1) each of the biomechanical parameters was markedly influenced by fracture gap fill ratio (FGFR) (defined as the proportion of the volume of the fracture gap that is considered occupied by the expanded polymer-filled balloon)?but not by modulus of elasticity assigned to the polymer;2) with FGFR = 100%, stiffness was comparable to that of the Ti-6Al-4V alloy VP construct model;and 3) stiffness was within the range of literature values for stiffness of constructs comprising simulated fractures in fresh cadaveric distal radii fixated using metal volar locking plate. These results suggest that the fixator may be an alternative modality to metal volar plating and, as such, deserves further evaluation. 展开更多
关键词 DISTAL Radius fracture VOLAR Locking Plate intramedullary fixation Finite Element Analysis
下载PDF
Screw Intramedullary Nailing for Fractures of the Humeral Shaft
10
作者 Y. S. Salphale W. M. Gadegone +1 位作者 R. M. Chandak Jayeshkumar Dave 《Surgical Science》 2015年第8期395-401,共7页
The debate continues over the management of diaphyseal fractures of the humerus. There are a variety of extramedullary as well as intramedullary implants. We aim to propose a technique of passing the screw intramedull... The debate continues over the management of diaphyseal fractures of the humerus. There are a variety of extramedullary as well as intramedullary implants. We aim to propose a technique of passing the screw intramedullary nails and achieve union with least trauma to the shoulder and the rotator cuff. The multiple elastic screw nails achieve the inherent stability based on the principle of “three point fixation”. We aim to propose that the screw intramedullary nail is an effective implant to facilitate uneventful fracture union, with rapid recovery, low morbidity and low learning curve capable of being replicated in any smaller operative set up. 展开更多
关键词 fracture HUMERUS Diaphyseal HUMERAL fracture SCREW intramedullary Nail HUMERUS NAILING
下载PDF
Health economics for intra-capsular hip fractures undertaking fixation
11
作者 Anatole Wiik Thomas Ashdown Ian Holloway 《World Journal of Orthopedics》 2024年第1期30-38,共9页
BACKGROUND Hip fracture is a common musculoskeletal injury in the elderly requiring surgery worldwide.The operative mainstay of intra-capsular hip fractures is arthroplasty with a smaller proportion for fixation.AIM T... BACKGROUND Hip fracture is a common musculoskeletal injury in the elderly requiring surgery worldwide.The operative mainstay of intra-capsular hip fractures is arthroplasty with a smaller proportion for fixation.AIM To determine the most beneficial method of fixation for patients with intracapsular hip fractures.METHODS A registered audit from 2012-2018 was conducted on all intra-capsular hip fractures treated with 2 commonly used fixation methods.Patient notes,electronic records and clinical codes for cost benefit were evaluated.A validated quality of life measure was collected at least 1 year after surgery.RESULTS A total of 83 patients were identified with intra-capsular fractures undergoing fixation during the retrospective period.There were 47 cannulated cancellous screw and 36 sliding hip screw fixations with the case mix comparable for age,gender,co-morbidities and fracture configuration.There was no significant difference in blood loss,tip apex distance,radiation exposure,length of stay,radiological union time,collapse,avascular necrosis or re-operation between fixation methods.Logistic regression analysis demonstrated displaced intracapsular hip fractures correlated significantly with an undesirable outcome conferring a relative odds ratio of 7.25.There were 9(19%)and 4(11%)patients respectively,who required re-operation.There was no significant difference in health resource group tariff and implant cost with comparable EQ-5D and visual CONCLUSION No significant advantage was identified with differing fixation type,but irrespective there were a high number of patients requiring re-operation.This was predicted by initial fracture displacement and patient age.Arthroplasty may need to be carefully considered for health economics and patient benefit. 展开更多
关键词 Hip fracture fixation Patient reported outcome measure COST
下载PDF
Arthroscopic M-shaped suture fixation for tibia avulsion fracture of posterior cruciate ligament:A modified technique and case series
12
作者 Xiao-Hui Zhang Jian Yu +3 位作者 Meng-Yao Zhao Jin-Hui Cao Bing Wu Dan-Feng Xu 《World Journal of Orthopedics》 2024年第7期642-649,共8页
BACKGROUND Tibial avulsion fractures of the posterior cruciate ligament(PCL)are challenging to treat and compromise knee stability and function.Traditional open surgery often requires extensive soft tissue dissection,... BACKGROUND Tibial avulsion fractures of the posterior cruciate ligament(PCL)are challenging to treat and compromise knee stability and function.Traditional open surgery often requires extensive soft tissue dissection,which may increase the risk of morbidity.In response to these concerns,arthroscopic techniques have been evolving.The aim of this study was to introduce a modified arthroscopic tech-nique utilizing an M-shaped suture fixation method for the treatment of tibial avulsion fractures of the PCL and to evaluate its outcomes through a case series.AIM To evaluate the effects of arthroscopic M-shaped suture fixation on treating tibia avulsion fractures of the PCL.METHODS We developed a modified arthroscopic M-shaped suture fixation technique for tibia avulsion fractures of the PCL.This case series included 18 patients who underwent the procedure between January 2021 and December 2022.The patients were assessed for range of motion(ROM),Lysholm score and International knee documentation committee(IKDC)score.Postoperative complications were also recorded.RESULTS The patients were followed for a mean of 13.83±2.33 months.All patients showed radiographic union.At the final follow-up,all patients had full ROM and a negative posterior drawer test.The mean Lysholm score significantly improved from 45.28±8.92 preoperatively to 91.83±4.18 at the final follow-up(P<0.001),and the mean IKDC score improved from 41.98±6.06 preoperatively to 90.89±5.32 at the final follow-up(P<0.001).CONCLUSION The modified arthroscopic M-shaped suture fixation technique is a reliable and effective treatment for tibia avulsion fractures of the PCL,with excellent fracture healing and functional recovery. 展开更多
关键词 Posterior cruciate ligament Avulsion fracture ARTHROSCOPIC Case series Suture fixation
下载PDF
Clinical Outcome of Internal Fixation and Fusion in the Treatment of Spinal Fractures by Paraspinal Muscular Space Approach
13
作者 Yafei Zhao Qiushuang Ma +3 位作者 Meng Zhang Shengwang Li Yannan Li Chenguang Tian 《Journal of Clinical and Nursing Research》 2024年第7期10-15,共6页
Objective:To explore the clinical effect of internal fixation and fusion with the paraspinal muscle gap approach in the treatment of spinal fracture patients.Methods:104 spinal fracture patients admitted to Central Ho... Objective:To explore the clinical effect of internal fixation and fusion with the paraspinal muscle gap approach in the treatment of spinal fracture patients.Methods:104 spinal fracture patients admitted to Central Hospital of TCM from October 2022 to April 2024 were selected as the study subjects and were randomly divided into the control group(n=52)and the observation group(n=52)according to the random number table method.The control group was treated with the conventional approach of internal fixation surgery,and the observation group was treated with the paraspinal muscular interspace approach of internal fixation fusion.The two groups’general data,surgical indexes,pain,lumbar spine function,and postoperative complications were observed.Results:The baseline data of the two groups of patients were not statistically significant(all P>0.05)while the intraoperative bleeding,the first postoperative time getting up from bed,and the length of hospital stay of the patients in the observation group were shorter than that of the control group(all P=0.000<0.001),and the duration of the operation was longer than that of the control group(t=2.644,P=0.010<0.05);at 3 months postoperatively,the VAS scores of the patients in the observation group were significantly lower than those in the control group(t=10.768,P=0.000<0.001),and the JOA score was higher than that of the control group(t=6.498,P=0.000<0.001);the total complication rate of patients in the observation group(3/5.77%)was significantly lower than that of the control group(12/23.08%)(χ^(2)=6.310,P=0.012<0.05).Conclusion:In the treatment of spinal fracture patients,compared with the conventional approach to internal fixation surgery,the paraspinal muscular gap approach to internal fixation and fusion treatment is less traumatic,postoperative lumbar spine function recovery is faster,and can reduce the incidence of postoperative complications. 展开更多
关键词 Paraspinal muscular interspace approach fixation and fusion Spinal fracture
下载PDF
Clinical Effectiveness of the Plate Screw Internal Fixation Technique in the Treatment of Patients with Traumatic Fractures of Long Bones in the Lower Extremities
14
作者 Yong Cai 《Proceedings of Anticancer Research》 2024年第3期115-120,共6页
Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 20... Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application. 展开更多
关键词 Plate screw internal fixation technique Traumatic fractures Long bones in the lower extremities EFFECTIVENESS
下载PDF
Olecranon anatomy:Use of a novel proximal interlocking screw for intramedullary nailing,a cadaver study 被引量:1
15
作者 Fatih Kücükdurmaz Necdet Saglam +2 位作者 Ismail Agir Cengiz Sen Fuat Akpinar 《World Journal of Orthopedics》 2013年第3期130-133,共4页
AIM: To define the optimum safe angle of use for an eccentrically aligned proximal interlocking screw(PIS) for intramedullary nailing(IMN).METHODS: Thirty-six dry cadaver ulnas were split into two equal pieces sagital... AIM: To define the optimum safe angle of use for an eccentrically aligned proximal interlocking screw(PIS) for intramedullary nailing(IMN).METHODS: Thirty-six dry cadaver ulnas were split into two equal pieces sagitally. The following points were identified for each ulna: the deepest point of the incisura olecrani(A), the point where perpendicular lines from A and the ideal IMN entry point(D) are intersected(C) and a point at 3.5 mm(2 mm safety distance from articular surface + 1.5 mm radius of PIS) posterior from point A(B). We calculated the angle of screws inserted from point D through to point B in relation to D-C and B-C. In addition, an eccentrically aligned screw was inserted at a standard 20° through the anterior cortex of the ulna in each bone and the articular surface wasobserved macroscopically for any damage.RESULTS: The mean A-C distance was 9.6 mm(mean ± SD, 9.600 ± 0.763 mm), A-B distance was 3.5 mm, C-D distance was 12.500 mm(12.500 ± 1.371 mm) and the mean angle was 25.9°(25.9°± 2.0°). Lack of articular damage was confirmed macroscopically in all bones after the 20.0° eccentrically aligned screws were inserted. Intramedullary nail fixation systems have well known biological and biomechanical advantages for osteosynthesis. However, as well as these well-known advantages, IMN fixation of the ulna has some limitations. Some important limitations are related to the proximal interlocking of the ulna nail. The location of the PIS itself limits the indications for which intramedullary systems can be selected as an implant for the ulna. The new PIS design, where the PIS is aligned 20°eccentrically to the nail body, allows fixing of fractures even at the level of the olecranon without disturbing the joint. It also allows the eccentrically aligned screw to be inserted in any direction except through the proximal radio-ulnar joint. Taking into consideration our results, we now use a 20° eccentrically aligned PIS for all ulnas. In our results, the angle required to insert the PIS was less than 20° for only one bone. However, 0.7° difference corresponds to placement of the screw only 0.2 mm closer to the articular surface. As we assume 2.0 mm to be a safe distance, a placement of the screw 0.2 mm closer to the articular surface may not produce any clinical symptoms.CONCLUSION: The new PIS may give us the opportunity to interlock IMN without articular damage and confirmation by fluoroscopy if the nail is manufactured with a PIS aligned at a 20.0° fixed angle in relation to the IMN. 展开更多
关键词 Interlocking screw intramedullary nailing Ulna fracture Ulna anatomy
下载PDF
Surgical Fixation of Fourth and Fifth Metacarpal Shaft Fractures with Flexible Intramedullary Absorbable Rods: Early Clinical Outcomes and Implications 被引量:3
16
作者 Ge Xiong Zi-Run Xiao +2 位作者 Shi-Gong GUO Wei Zheng Lu-Fei Dai 《Chinese Medical Journal》 SCIE CAS CSCD 2015年第21期2851-2855,共5页
Background: To avoid the irritation of tendons and soft tissues as well as hardware-related problems, we designed an intramedullary fixation with bioabsorbable rods for the treatment of the metacarpal shaft fractures... Background: To avoid the irritation of tendons and soft tissues as well as hardware-related problems, we designed an intramedullary fixation with bioabsorbable rods for the treatment of the metacarpal shaft fractures. Methods: Five patients with nine shaft fractures of the fourth and fifth metacarpi were treated with intramedullary absorbable implants and followed up with an average of 4.2 months postoperatively. Results: At final follow-up, all patients achieved fracture union with no signs of inflammatory or subcutaneous effusion. There was no shortening, angulatory, or rotatory deformity. There was almost full active extension range of motion (ROM) of the metacarpophalangeal joints while the active flexion ROM of these joints was 80.7 ± 9.6°. hand was 94.0 ± 9.6%. X-rays showed that the arch of the second Compared with the contralateral hand, the grip strength of the injured to fifth metacarpal heads was smooth. There were no intramedullary lytic changes and soft tissue swellings. Conclusion: The intramedullary absorbable implants are a safe, simple, and practical treatment for fourth and filth metacarpal fractures with good early clinical outcomes and no significant complications. 展开更多
关键词 Absorbable Implant Follow-up: intramedullary fixation Metacarpal fracture
原文传递
Management of geriatric acetabular fractures:Contemporary treatment strategies
17
作者 Theodoros Tosounidis Byron Chalidis 《World Journal of Clinical Cases》 SCIE 2024年第13期2151-2156,共6页
Acetabular fractures in the geriatric population are typically low-energy fractures resulting from a fall from standing height.Compromised bone quality in the elderly,as well as this population’s concomitant medical ... Acetabular fractures in the geriatric population are typically low-energy fractures resulting from a fall from standing height.Compromised bone quality in the elderly,as well as this population’s concomitant medical comorbidities,render the management of such fractures challenging and controversial.Non-operative management remains the mainstay of treatment,although such a choice is associated with numerous and serious complications related to both the hip joint as well as the general condition of the patient.On the other hand,operatively treating acetabular fractures(e.g.,with osteosynthesis or total hip arthroplasty)is gaining popularity.Osteosynthesis can be performed with open reduction and internal fixation or with minimally invasive techniques.Total hip arthroplasty could be performed either in the acute phase combined with osteosynthesis or as a delayed procedure after a period of non-operative management or after failed osteosynthesis of the acetabulum.Regardless of the implemented treatment,orthogeriatric co-management is considered extremely crucial,and it is currently one of the pillars of a successful outcome after an acetabular fracture. 展开更多
关键词 Acetabular fractures Geriatric fractures fracture fixation Total hip arthroplasty MORTALITY MORBIDITY
下载PDF
Clinical outcomes of triceps reflecting anconeus pedicle and olecranon osteotomy approach for distal humerus intercondylar fractures
18
作者 Rohit Ailani Sanjeev Kumar Bhuyan +2 位作者 Brejesh Kumar Prasad Amit Kumar Namrata Dawani 《World Journal of Orthopedics》 2024年第6期570-577,共8页
BACKGROUND The preferred treatment for distal humeral intercondylar fractures is open reduction and internal fixation.While there is consensus about the posterior approach,several posterior approaches have been develo... BACKGROUND The preferred treatment for distal humeral intercondylar fractures is open reduction and internal fixation.While there is consensus about the posterior approach,several posterior approaches have been developed.It is debatable as to which approach is best.AIM To compare triceps reflecting anconeus pedicle(TRAP)and olecranon osteotomy approaches for internal fixation of distal humeral intercondylar fracture.METHODS In total,40 cases of Arbeitsgemeinschaft für Osteosynthesefragen/Association of the Study of Internal Fixation type C,closed,and Gustilo type I intercondylar humeral fractures were included.Patients ranged in age from 18 years to 70 years.The patients were randomized into two groups:TRAP group and olecranon osteotomy group,with 20 cases in each.All were followed up at 6 wk,3 months,6 months,and 12 months.Functional outcomes were measured in terms of flexion-extension arc,Disabilities of Arm,Shoulder and Hand score,and Mayo Elbow Performance Score.RESULTS The mean age was 43.2 years in the TRAP group and 37.5 years in the olecranon osteotomy group.The mean operative time and mean duration of hospital stay in the TRAP group were significantly higher than in the olecranon osteotomy group(119.5 vs 111.5 min and 9.85 vs 5.45 d,respectively).The mean arc of flexion-extension,Disabilities of Arm,Shoulder and Hand score,and Mayo Elbow Performance Score were comparable without any significant difference in the groups at the 12-month follow-up(107.0 vs 106.2,18.3 vs 15.7,and 84.2 vs 86.2,respectively).Ulnar paresthesia and superficial infections were comparable in both groups(2 cases vs 3 cases and 3 cases vs 2 cases,respectively).Hardware prominence was significantly higher in the olecranon osteotomy group,mostly due to tension band wiring.CONCLUSION Both approaches were equivalent,but there is a need for further study including higher numbers of subjects and longer study duration to prove the benefits of one approach over the other. 展开更多
关键词 Elbow joint Humeral fracture OSTEOTOMY INTERNAL fracture fixation
下载PDF
Subtrochanteric femur fracture treated by intramedullary fixation 被引量:4
19
作者 Zu-Bin Zhou Song Chen +3 位作者 You-Shui Gao Yu-Qiang Sun Chang-O_ing Zhang Yao Jiang 《Chinese Journal of Traumatology》 CAS CSCD 2015年第6期336-341,共6页
Purpose: To discuss surgical technique, operative efficacy and clinical outcome of intramedullary fixation in the treatment of subtrochanteric femur fractures. Methods: From February 2011 to February 2013, 76 cases ... Purpose: To discuss surgical technique, operative efficacy and clinical outcome of intramedullary fixation in the treatment of subtrochanteric femur fractures. Methods: From February 2011 to February 2013, 76 cases of subtrochanteric femur fractures were treated by intramedullary fixation in our hospital, including 53 males and 23 females, with the age range of 37 -72 years (mean 53.5 years). According to Seinsheimer classification, there were 2 cases of type I, 7 type Ⅱ, 15 type Ⅲ, 23 type IV and 29 type V. Firstly, all patients underwent closed reduction with the guidance of C-arm fluoroscopy in a traction table. Two cases of type I and 3 cases of type Ill fractures had ideal closed reduction followed by internal fixation. The others needed additional limited open reduction. Radiographic examination was used to evaluate callus formation and fracture healing in postoperative 1, 3, 6 and 12 months follow-up. Functional recovery was evaluated by Harris Hip Scoring (HHS) system. Results: Patients were followed up for 6-12 months. All fractures were healed except one patient with delayed union. The average bone union time was 4.5 months. According to HHS system, 65 cases were considered as excellent in functional recovery, 8 good, 2 fair and 1 poor. The proportion of the patients with excellent and good recovery was 96.05%. Conclusion: Intramedullary fixation is feasible for the treatment of subtrochanteric femur fracture. The accuracy of intraoperative reduction and surgical skill are important for the clinical outcome and the patients' prognosis. 展开更多
关键词 SUBTROCHANTERIC FEMUR fractureS intramedullary NAIL Surgical procedures OPERATIVE
原文传递
Meta-analysis of the efficacy of volar plate internal fixation versus closed reduction and external fixation in the treatment of adult distal radius fractures
20
作者 CHEN Jian-ge ZHANG Hai-ning +4 位作者 ZHAO Hong-zhou LIU Ming-jun XING Jia-hui WANG Ping WANG Wei-min 《Journal of Hainan Medical University》 CAS 2023年第19期44-56,共13页
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ... Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority. 展开更多
关键词 Volar plate Internal fixation Closed reduction External fixation PLASTER SPLINT Distal radius fracture Meta analysis