期刊文献+
共找到25篇文章
< 1 2 >
每页显示 20 50 100
ROBUST ACOUSTIC SOURCE LOCALIZATION FOR DIGITAL HEARING AIDS IN NOISE AND REVERBERANT ENVIRONMENT 被引量:1
1
作者 赵立业 李宏生 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2010年第2期176-182,共7页
A new method in digital hearing aids to adaptively localize the speech source in noise and reverberant environment is proposed. Based on the room reverberant model and the multichannel adaptive eigenvalue decompositi... A new method in digital hearing aids to adaptively localize the speech source in noise and reverberant environment is proposed. Based on the room reverberant model and the multichannel adaptive eigenvalue decomposition (MCAED) algorithm, the proposed method can iteratively estimate impulse response coefficients between the speech source and microphones by the adaptive subgradient projection method. Then, it acquires the time delays of microphone pairs, and calculates the source position by the geometric method. Compared with the traditional normal least mean square (NLMS) algorithm, the adaptive subgradient projection method achieves faster and more accurate convergence in a low signal-to-noise ratio (SNR) environment. Simulations for glasses digital hearing aids with four-component square array demonstrate the robust performance of the proposed method. 展开更多
关键词 hearing aids acoustic source localization multichannel adaptive eigenvalue decomposition (MCAED) algorithms adaptive subgradient projection method
下载PDF
Efficient design method of non-uniform cosine modulated filter bank for digital hearing aids
2
作者 郭如雪 赵力 +1 位作者 梁瑞宇 邹采荣 《Journal of Southeast University(English Edition)》 EI CAS 2017年第2期140-144,共5页
To promote the performance of the traditional multichannel filter bank which leads to speech quality degradation,an efficient design method of the non-uniform cosine modulated filter bank(CMFB) based on the audiogra... To promote the performance of the traditional multichannel filter bank which leads to speech quality degradation,an efficient design method of the non-uniform cosine modulated filter bank(CMFB) based on the audiogram for digital hearing aids is proposed. First, a low-pass prototype filter is designed by the linear iterative algorithm. Secondly,the uniform CMFB is achieved on the basis of the principle formulas. Then, the adjacent channels of a uniform filter bank which have low or gradual slopes are merged according to the trend of audiogram of the hearing impaired person. Finally,the corresponding non-uniform CMFB is obtained. Simulation results show that the signal processed by the proposed filter bank is similar to the original signal in a time-domain waveform and spectrogram without significant distortion or difference. The speech quality results show that the personal evaluation of speech quality(PESQ) of non-uniform CMFB is 35% higher than that of the traditional design, and the hearing-aid speech quality index(HASQI) increases by about 40%. 展开更多
关键词 digital hearing aids cosine modulated filter bank(CMFB) non-uniform filter bank speech quality
下载PDF
Verification and validation of hearing aids:Opportunity not an obstacle 被引量:1
3
作者 Lindsey E.Jorgensen 《Journal of Otology》 CSCD 2016年第2期57-62,共6页
Verification and validation are objective and subjective measurements of hearing aid function. Many studies have provided rationales for performing these measurements as necessary for hearing aid practitioners to prov... Verification and validation are objective and subjective measurements of hearing aid function. Many studies have provided rationales for performing these measurements as necessary for hearing aid practitioners to provide the highest level of care. Several researchers have suggested that completing these measurements as part of routine clinical care will reduce the number of return visits, reduce the number of aids returned for credit, and increase patient satisfaction. The purpose of this review article is to provide background, method and rationale for practitioners to use these measurements to improve their practice of hearing healthcare. 展开更多
关键词 hearing aids Verification Real-ear measurements Probe-microphone measurements SATISFACTION
下载PDF
A comparison of the quality of life of parents of children using hearing aids and those using cochlear implants
4
作者 Saranya Arya Mundayoor Prabuddha Bhatarai Prashanth Prabhu 《Journal of Otology》 CSCD 2022年第4期211-217,共7页
Objective:The goal of this study was to evaluate the quality of life of parents of children who use hearing aids(HA)with those who use cochlear implants(CI)in the Indian context and document any differences found.Meth... Objective:The goal of this study was to evaluate the quality of life of parents of children who use hearing aids(HA)with those who use cochlear implants(CI)in the Indian context and document any differences found.Methods:The Kannada version of the AQoL-4D was administered in a modified fashion to 131 parents(87 HA and 44 CI).Sociodemographic details were collected for supplemental information on the intervention strategy used.Results:A total of 49 parents(29 HA and 20 CI)responded to the questionnaire sent.The mean total scores for both the groups were similar(HA group=17.9(SD=5.5),CI group=17.2(SD=3.4)),as was the score for the first subscale(HA group=8.6(SD=2.9);CI group=8.5(SD=2.6))of the AQoL-4D.No significant differences were found between the two groups on either scores[Total Score:U(N_(HA)=29,NCI=20)=280.5,z=0.194,p>0.05;Subscale 1 Score:U(N_(HA)=29,NCI=20)=281.5,z=-0.176,p>0.05].The degree of hearing loss in the hearing aid group was equivalent to that of the cochlear implant group but this did not appear to influence parental quality of life.Conclusion:Parents of children with hearing aids and cochlear implants appear to be similar on several psychosocial factors in the realms of functional,social,and psychological well-being.In terms of parental quality of life,hearing aids and cochlear implants appear to be equally effective intervention techniques. 展开更多
关键词 Quality of life PARENTS Cochlear implants hearing aids CHILDREN hearing impaired
下载PDF
SOUND SOURCE LOCALIZATION OF DIGITAL HEARING AIDS USING WAVELET BASED MULTIVARIATE STATISTICAL METHOD
5
作者 Liang Ruiyu Zou Cairog +1 位作者 Wang Qingyu Xi Ji 《Journal of Electronics(China)》 2010年第4期571-576,共6页
The letter proposed a sound source localization method of digital hearing aids using wavelet based multivariate statistics with the Generalized Cross Correlation (GCC) algorithm. Haar wavelet is used to decompose GCC ... The letter proposed a sound source localization method of digital hearing aids using wavelet based multivariate statistics with the Generalized Cross Correlation (GCC) algorithm. Haar wavelet is used to decompose GCC sequences and extract four wavelet characteristics. And then, Hotelling T2 statistical method is used to fuse the four wavelet characteristics. The statistical value is used to judge the number of sound sources and obtain corresponding time delay estimation which is used to localize the position of sound source. The experimental results show that the proposed method has better robustness in an environment with severe noise and reverberation. Meanwhile, the complexity of al-gorithm is moderate, which is available for sound source localization of hearing aids. 展开更多
关键词 Sound source localization Wavelet decomposition Hotelling T2 statistical model Digital hearing aids
下载PDF
Efficacy of Remote Hearing Aids Programming Using Teleaudiology: A Systematic Review
6
作者 Maryam Hussein Abdullah Ba Mashmous 《E-Health Telecommunication Systems and Networks》 2022年第1期14-33,共20页
Telemedicine is defined as a system that allows healthcare workers to deliver their services and consultations to the patients remotely without the need of their physical presence within academic institutions, hospita... Telemedicine is defined as a system that allows healthcare workers to deliver their services and consultations to the patients remotely without the need of their physical presence within academic institutions, hospitals, and medical clinics aiming to reduce the personal contact and limiting it to the need only. The field of telemedicine is growing every day and facilitating more flexible services for patients around the world especially during COVID-19 pandemic. Methods: This systematic review was conducted according to the Cochrane Handbook for Systematic Reviews. Database search was made on several databases including PubMed/Medline, Scopus, Web of Science, Publons, EMBASE, and Google Scholar using the relevant keywords. Inclusion criteria for articles in our study included the following original research (primary research articles), addressing the efficacy of teleaudiology for hearing aids programming and satisfaction of patients. Results: Seven studies were included in this systematic review article. Included studies were assessed using Cochrane handbook guidelines. Conclusions: The results of this work based on the currently available literature denote that remote programming for the hearing aids using modern technology is effective and provide comparable results with the standard face-to-face clinic programming, even for patients with no previous experience in hearing aids fitting in either of in-person physical presence programming or remotely over the internet using teleconferencing which is known as teleaudiology. Most of the results were positive and support the continuity to develop better facilities to improve the teleaudiology to be an essential part of hearing aids programming with its different types. Minimal results provided negative impact from the participating patients, this resulted because of the non-upgraded infrastructure and facilities of the audiology clinic or the personal computer of the patient in his home/ workplace or both sides don’t have enough specifications to smoothly perform this modern approach. 展开更多
关键词 TELEMEDICINE Teleaudiology hearing aids and COVID-19 Pandemic
下载PDF
Effect analysis of unilateral deaf adults wearing bone-conduction hearing aids:A case report
7
作者 Chenchen Xiang Yi Wang +6 位作者 Xiaozhu Cao Weiman Xv Jing Liu Nan Li Lumeng Han QIan Wang Fei Ji 《Journal of Otology》 CAS 2024年第4期207-213,共7页
The prevalence of unilateral deafness(SSD)or asymmetric hearing loss(AHL)among patients with hearing impairments ranges from 7.2%to 15.0%,indicating a relatively significant proportion.However,these individuals often ... The prevalence of unilateral deafness(SSD)or asymmetric hearing loss(AHL)among patients with hearing impairments ranges from 7.2%to 15.0%,indicating a relatively significant proportion.However,these individuals often overlook their hearing loss,resulting in delayed or inadequate treatment.This oversight can lead to a lack of binaural summation and squelch effect,as well as the head shadow effect,which can significantly impact their speech recognition and sound localization abilities,especially in noisy environments.Recently,a groundbreaking Sound Bite™Pinyin® Bone Conduction Hearing Aid(HA)device has been has been introduced as a viable alternative to traditional percutaneous stimulation hearing assistance devices.This innovative device harnesses bone conduction technology to convey sound vibrations directly to the inner ear via the bones of the jaw and skull,effectively bypassing the air conduction pathway that is commonly compromised in individuals with hearing loss.This report details the evaluation and adjustment process of a HA device worn by a 31-year-old female patient who suffers from a congenital ossicular chain deformity in her right ear,while maintaining normal hearing in her left ear.The report comprehensively covers the hearing thresholds of the 31-year-old female patient on the day of fitting the hearing aid and one month later.It also presents assessments of the hearing aid’s performance through the Abbreviated Profile of Hearing Aid Benefit(APHAB)questionnaire,conducted three days after adjustment,one month later,and one year later.Furthermore,the report details the evaluation of the patient’s sound localization ability,comparing her performance before and after wearing the hearing aid device.Additionally,it includes measurements of her speech recognition ability for monosyllabic words and Yang Yang Ge words,which are specific tests in the Chinese language,conducted two years after the initial fitting of the hearing aid.The discovery that bone-anchored hearing devices can significantly enhance hearing thresholds in patients with unilateral conductive hearing loss represents a significant milestone.These devices not only improve speech recognition ability but also enhance sound localization in noisy environments.This improvement is accompanied by a high level of subjective satisfaction among patients,indicating a positive impact on their overall quality of life. 展开更多
关键词 Bone conduction hearing aid Abbreviated profile of hearing aid benefit Speech audiometry
下载PDF
Appropriate Hearing Aids Significantly Increase the Quality of Life in Presbycusis: An Observational Study
8
作者 A. H. M. Delwar 《International Journal of Otolaryngology and Head & Neck Surgery》 2024年第6期442-460,共19页
Background: Hearing is a unique sense that allows communication. Hearing loss leads to mental depression, social deprivation, cognitive decline, and gradually decreasing daily performance, making the person handicappe... Background: Hearing is a unique sense that allows communication. Hearing loss leads to mental depression, social deprivation, cognitive decline, and gradually decreasing daily performance, making the person handicapped. Presbycusis is a disease of older people, suffering 360 million worldwide. Methods: The present study is a cross-sectional study in the Comilla Medical College (https://www.cumc.edu.bd) and Cumilla Medical Centre (http://www.comillamedicalcentre.com/) of the Department of the Otolaryngology and Head-Neck Surgery Cumilla, Bangladesh, from 01 February 2024 to 31 July 2024. Results: The study was conducted in a developing country searching for adequate rehabilitation with hearing aids at maximum hearing loss. Hearing rehabilitation faces challenges like low awareness, stigma, and insufficient healthcare infrastructure. The paired sample T-test was done between pure tone audiometry (PTA) tests before and after using a hearing aid in the right and left ear. It showed that hearing aids significantly increased hearing that p ≤ 0.001. The t-test of WHO quality of life before and after using hearing aids revealed p ≤ 0.001, and the HHIE-S score exhibited p ≤ 0.001. Conclusion: It needs adequate support to improve hearing health by increasing the number of audiologists and trained healthcare workers and supplying low-cost hearing aids and services. 展开更多
关键词 Presbycusis hearing Aid Pure Tone Audiometry WHOQOL HHIE-S
下载PDF
Development and Optimization of Universal Bone Conduction Hearing Spectacles
9
作者 Johannes Burkart Mona Kirstin Fehling +2 位作者 Saadu Adamu Raúl Pérez Ramos Daniel Häussler 《International Journal of Otolaryngology and Head & Neck Surgery》 2024年第5期344-358,共15页
Background: Non-implantable bone anchored hearing devices (BCHDs) are utilized for patients with conductive or mixed hearing loss who are unsuitable for conventional hearing aids or have unresolved middle ear issues. ... Background: Non-implantable bone anchored hearing devices (BCHDs) are utilized for patients with conductive or mixed hearing loss who are unsuitable for conventional hearing aids or have unresolved middle ear issues. These devices can be surgically implanted or attached using adhesive plates, dental sticks, elastic headbands, or bone conduction spectacles. Optimal fitting of bone conduction spectacles requires appropriate frame selection and contact pressure in the temporal and mastoid areas. The ANSI S3.6 and DIN EN ISO 389-3 standards recommend a contact area of approximately 1.75 cm2 and a maximum force of 5.4 N for effective sound transmission and comfort. Methods: This study aimed to evaluate the technical fit and mechanical stability of universal bone conduction hearing spectacles compared to established systems. A Sen-Pressure 02 thin-film sensor connected to an Arduino Uno R3 board measured contact force in the temporal and mastoid areas. Several BCHDs were tested, including the Bruckhoff la belle BC D50/70, Radioear B71 headset, Radioear B71 elastic headband, Cochlear Baha SoundArc M, and Cochlear Baha elastic headband, on a PVC artificial head, with data analyzed using ANOVA and LSD post hoc tests. Results: The la belle BC D50/70 spectacles showed comparable contact force to established BCHDs, ensuring adequate sound transmission and comfort. Significant differences were observed between the systems, with the Radioear B71 headset exhibiting the highest forces. The la belle BC D50/70 had similar forces to the Radioear B71 elastic headband. Conclusion: The la belle BC D50/70 universal bone conduction hearing spectacles are a technically equivalent alternative to established BCHDs, maintaining pressure below 5.4 N. Future research should explore the impact of different contact forces on performance and comfort, and the integration of force control in modified spectacles. This study indicates that the la belle BC D50/70 is a viable alternative that meets audiological practice requirements. 展开更多
关键词 Bone Conduction hearing Devices (BCHD) Universal Bone Conduction hearing Spec-Tacles Non-Implantable hearing aids Contact Pressure Optimization
下载PDF
Adaptive feedback cancellation based on variable step-size affine projection for hearing aids
10
作者 Qin Haijuan Zhang Linghua 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2015年第1期6-10,56,共6页
A new variable step-size (VSS) affine projection algorithm (APA) (VSS-APA) was proposed for adaptive feedback cancellation suitable for hearing aids. So, a nonlinear function between step-size and estimation err... A new variable step-size (VSS) affine projection algorithm (APA) (VSS-APA) was proposed for adaptive feedback cancellation suitable for hearing aids. So, a nonlinear function between step-size and estimation error is established and automatically adjusted according to the change of the estimation error, which leads to low misalignment and fast convergence speed. Analysis of the proposed algorithm offers large capacities in converging to the objective system. Simulation shows that the proposed algorithm achieves lower misalignment and faster convergence speed compared to fixed step-size APA and conventional adaptive algorithms. 展开更多
关键词 adaptive feedback cancellation VSS APA adaptive filter hearing aids
原文传递
A sub-milliwatt audio-processing platform for digital hearing aids
11
作者 袁甲 陈黎明 +1 位作者 于增辉 黑勇 《Journal of Semiconductors》 EI CAS CSCD 2014年第7期160-164,共5页
We present a novel audio-processing platform, FlexEngine, which is composed of a 24-bit applicationspecific instruction-set processor (ASIP) and five dedicated accelerators. Acceleration instructions, compact instru... We present a novel audio-processing platform, FlexEngine, which is composed of a 24-bit applicationspecific instruction-set processor (ASIP) and five dedicated accelerators. Acceleration instructions, compact instructions and repeat instruction are added into the ASIP's instruction set to deal with some core tasks of hearing aid algorithms. The five configurable accelerators are used to execute several of the most common functions of hearing aids. Moreover, several low power strategies, such as clock gating, data isolation, memory partition, bypass mode, sleep mode, are also applied in this platform for power reduction. The proposed platform is implemented in CMOS 130 nm technology, and test results show that power consumption of FlexEngine is 0.863 mW with the clock frequency of 8 MHz at Vdd = 1.0 V. 展开更多
关键词 application-specific instruction-set processor (ASIP) ACCELERATOR low power hearing aids
原文传递
Investigation of hearing aid users'speech understanding in noise and their spectral-temporal resolution skills
12
作者 Mert Kılıç Eyyup Kara 《Journal of Otology》 CAS CSCD 2023年第3期146-151,共6页
Purpose:Our study aims to compare speech understanding in noise and spectral-temporal resolution skills with regard to the degree of hearing loss,age,hearing aid use experience and gender of hearing aid users.Methods:... Purpose:Our study aims to compare speech understanding in noise and spectral-temporal resolution skills with regard to the degree of hearing loss,age,hearing aid use experience and gender of hearing aid users.Methods:Our study included sixty-eight hearing aid users aged between 40-70 years,with bilateral mild and moderate symmetrical sensorineural hearing loss.Random gap detection test,Turkish matrix test and spectral-temporally modulated ripple test were implemented on the participants with bilateral hearing aids.The test results acquired were compared statistically according to different variables and the correlations were examined.Results:No statistically significant differences were observed for speech-in-noise recognition,spectraltemporal resolution among older and younger adults in hearing aid users(p>0.05).There wasn’t found a statistically significant difference among test outcomes as regards different hearing loss degrees(p>0.05).Higher performances were obtained in terms of temporal resolution in male participants and participants with more hearing aid use experience(p<0.05).Significant correlations were obtained between the results of speech-in-noise recognition,temporal resolution and spectral resolution tests performed with hearing aids(p<0.05).Conclusion:Our study findings emphasized the importance of regular hearing aid use and it showed that some auditory skills can be improved with hearing aids.Observation of correlations among the speechin-noise recognition,temporal resolution and spectral resolution tests have revealed that these skills should be evaluated as a whole to maximize the patient’s communication abilities. 展开更多
关键词 hearing aids Speech in noise Spectral resolution Speech intelligibility Temporal resolution
下载PDF
A 1.4-V 48-μW current-mode front-end circuit for analog hearing aids with frequency compensation
13
作者 王晓宇 杨海钢 +2 位作者 李凡阳 尹韬 刘飞 《Journal of Semiconductors》 EI CAS CSCD 2012年第10期77-84,共8页
A current-mode front-end circuit with low voltage and low power for analog hearing aids is presented. The circuit consists of a current-mode AGC(automatic gain control) and a current-mode adaptive filter.Compared wi... A current-mode front-end circuit with low voltage and low power for analog hearing aids is presented. The circuit consists of a current-mode AGC(automatic gain control) and a current-mode adaptive filter.Compared with its conventional voltage-mode counterparts,the proposed front-end circuit has the identified features of frequency compensation based on the state space theory and continuous gain with an exponential characteristic.The frequency compensation which appears only in the DSP unit of the digital hearing aid can upgrade the performance of the analog hearing aid in the field of low-frequency hearing loss.The continuous gain should meet the requirement of any input amplitude level,while its exponential characteristic leads to a large input dynamic range in accordance with the dB SPL(sound pressure level).Furthermore,the front-end circuit also provides a discrete knee point and discrete compression ratio to allow for high calibration flexibility.These features can accommodate users whose ears have different pain thresholds.Taking advantage of the current-mode technique,the MOS transistors work in the subthreshold region so that the quiescent current is small.Moreover,the input current can be compressed to a low voltage signal for processing according to the compression principle from the current-domain to the voltage-domain.Therefore,the objective of low voltage and low power(48μW at 1.4 V) can be easily achieved in a high threshold-voltage CMOS process of 0.35μm(V(TON) + |V(TOP)|≈1.35 V).The THD is below -45 dB.The fabricated chip only occupies the area of 1×0.5 mm^2 and 1×1 mm^2. 展开更多
关键词 hearing aid frequency compensation state space continuous gain CURRENT-MODE
原文传递
Speech intelligibility and auditory perception of pre-school children with Hearing Aid,cochlear implant and Typical Hearing 被引量:2
14
作者 Mohammad Ashori 《Journal of Otology》 CSCD 2020年第2期62-66,共5页
Purpose:There is a growing interest in speech intelligibility and audito ry perception of deaf children.The aim of the present study was to compare speech intelligibility and auditory perception of pre-school children... Purpose:There is a growing interest in speech intelligibility and audito ry perception of deaf children.The aim of the present study was to compare speech intelligibility and auditory perception of pre-school children with Hearing Aid(HA),Cochlear Implant(Cl),and Typical Hearing(TH).Methods:The research design was descriptive-analytic and comparative.The participants comprised 75 male pre-school children aged 4-6 years in the 2017-2018 from Tehran,Iran.The participants were divided into three groups,and each group consisted of 25 children.The first and second groups were respectively selected from pre-school children with HA and CI using the convenience sampling method,while the third group was selected from pre-school children with TH by random sampling method.All children completed Speech Intelligibility Rating and Catego ries of Auditory Performance Questionnaires.Results:The findings indicated that the mean scores of speech intelligibility and auditory perception of the group with TH were significantly higher than those of the other groups(P<0.0001).The mean scores of speech intelligibility in the group with CI did not significantly differ from those of the group with HA(P<0.38).Also,the mean scores of auditory perception in the group with CI were significantly higher than those of the group with HA(P<0.002).Conclusion:The results showed that auditory perception in children with CI was significantly higher than children with HA.This finding highlights the importance of cochlear implantation at a younger age and its significant impact on auditory perception in deaf children. 展开更多
关键词 Speech intelligibility Auditory perception hearing aid Cochlear implant
下载PDF
Skin reactions caused by bone-anchored hearing aid(BAHA) implantation 被引量:1
15
作者 Gen-di Yin Xiangli Zeng Peng Li 《Journal of Otology》 CSCD 2015年第4期159-162,共4页
Objective: To report a case of intractable skin reactions caused by bone-anchored hearing aid (BAHA) implantation to improve our under-standing and treatment of BAHA implantation-caused skin reactions. Methods:We repo... Objective: To report a case of intractable skin reactions caused by bone-anchored hearing aid (BAHA) implantation to improve our under-standing and treatment of BAHA implantation-caused skin reactions. Methods:We reported a case of severe skin reactions caused by BAHA implantation. Related literature were also reviewed. Results:We found grade IV skin reactions, including hyperplasia around the implant, which led to the removal of the BAHA implant 10 months after implantation. The findings indicated poor skin hygiene, allergy to titanium and inadequate surgicals skills as the possible causes of the skin reaction. Conclusion: Skin adverse reactions, usually rare in BAHA implantation patients, may cause implant removal and implantation failure. We suggest to further investigate the mechanisms underlying titanium allergy. Copyright ? 2016, PLA General Hospital Department of Otolaryngology Head and Neck Surgery. Production and hosting by Elsevier (Singapore) Pte Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). 展开更多
关键词 Conductive hearing disorder Bone-anchored hearing aid(BAHA) Skin reactions
下载PDF
Development of an Auditory Rehabilitation Training Programme for Hearing Impaired Adults in Saudi Arabia
16
作者 Aseel Alkhamees Karen Bryan Merle Mahon 《Journal of Health Science》 2016年第6期304-317,共14页
Hearing impairment is one of the most common sensory disabilities, affecting millions of people worldwide. The current management of acquired hearing impairment in adults is usually in the form of hearing aids. An aud... Hearing impairment is one of the most common sensory disabilities, affecting millions of people worldwide. The current management of acquired hearing impairment in adults is usually in the form of hearing aids. An auditory rehabilitation programme may or may not be provided although literature suggests that such programmes may enhance hearing aid benefits. This study was conducted in an Arabic-speaking country, specifically Saudi Arabia, and is the first to develop an auditory rehabilitation intervention programme in the Arabic language that focuses on working age adults who are new hearing aid users. Randomised intervention study design. Thirty-five participants with mild to severe acquired hearing loss (intervention group n = 18, control group n = 17). Significant changes were found in the performance of the intervention group in the Minimal Audible Capabilities (MAC) test, a lip reading test and the Glasgow Hearing Aid Benefit Profile (GHABP) questionnaire when compared with the control group. No significant difference was found in speech test scores between the two groups. A short individualised auditory rehabilitation intervention programme can yield a significant improvement in the performance of hearing impaired adults by enhancing the benefits of hearing aid use. 展开更多
关键词 hearing loss hearing aid auditory rehabilitation speech test Minimal Audible Capabilities (MAC) test lip reading test Glasgow hearing Aid Benefit Profile (GHABP) questionnaire Saudi Arabia.
下载PDF
Hearing Aid
17
《大学英语》 2003年第3期38-,共1页
A man realized that he needed to purchase ahearing aid, but he was unwilling to spend muchmoney. "How much do they run?"he asked theclerk. "That depends," said. the salesman. "Theyrun from 2 t... A man realized that he needed to purchase ahearing aid, but he was unwilling to spend muchmoney. "How much do they run?"he asked theclerk. "That depends," said. the salesman. "Theyrun from 2 to 2000." 展开更多
关键词 hearing Aid
下载PDF
An adaptive multichannel loudness compensation method
18
作者 王侠 梁瑞宇 +3 位作者 王青云 申红明 赵力 邹采荣 《Journal of Southeast University(English Edition)》 EI CAS 2016年第2期141-145,共5页
To alleviate the conflict between audibility and distortion in the conventional loudness compensation method, an adaptive multichannel loudness compensation method is proposed for hearing aids. The linear and wide dyn... To alleviate the conflict between audibility and distortion in the conventional loudness compensation method, an adaptive multichannel loudness compensation method is proposed for hearing aids. The linear and wide dynamic range compression (WDRC) methods are alternately employed according to the dynamic range of the band-passed signal and the hearing range (HR) of the patient. To further reduce the distortion caused by the WDRC and improve the output signal to noise ratio (SNR) under noise conditions, an adaptive adjustment of the compression ratio is presented. Experimental results demonstrate that the output SNR of the proposed method in babble noise is improved by at least 1.73 dB compared to the WDRC compensation method, and the average speech intelligibility is improved by 6.0% and 5. 7%, respectively, compared to the linear and WDRC compensation methods. 展开更多
关键词 loudness compensation wide dynamic rangecompression gammatone filter banks hearing aids
下载PDF
Middle Ear Implants:Historical and futuristic perspective
19
作者 Guyan Andre Channer Adrien A Eshraghi 《Journal of Otology》 2011年第2期10-18,共9页
Technological advancements are continuously changing the paradigm of human existence.Human beings are constantly engaging in various measures to reduce the extent of sensory and motor impairment.This has been in the f... Technological advancements are continuously changing the paradigm of human existence.Human beings are constantly engaging in various measures to reduce the extent of sensory and motor impairment.This has been in the form of various devices,e.g.orthopedic prosthesis,visual aids (spectacles) and hearing aids.Countless attempts throughout the centuries have been made in an effort to improve sound amplification in patients.This article seeks to highlights the technological journey of one such implant,the middle ear implant,from its inception to the more technological advanced futuristic proposals.While there are many amplification devices available presently,there still remains a group of patients who have not experienced adequate amplification for their hearing loss and this subset may gain the greatest benefit from middle ear implants. 展开更多
关键词 middle ear implants vibrant sound bridge esteem envoy Rion E device hearing aids Totally Implantable Cochlear Amplifier middle ear transducer (MET) MAXUM
下载PDF
Contemporary solutions for patients with microtia and congenital aural atresia-Hong Kong experience
20
作者 Willis S.S.Tsang Michael C.F.Tong +4 位作者 Peter K.M.Ku Kunwar S.S.Bhatia Joannie K.Y.Yu Terence K.C.Wong C.Andrew van Hasselt 《Journal of Otology》 CSCD 2016年第4期-,共8页
Managing microtia patients is always a challenge. Multidisciplinary approach, good family support, well established doctorepatient rela-tionship and well organised patient-support groups are the essential elements for... Managing microtia patients is always a challenge. Multidisciplinary approach, good family support, well established doctorepatient rela-tionship and well organised patient-support groups are the essential elements for success. With the advancement of implantable hearing devices, more options will be available for the microtia patients. Otologists play a leading role in the whole management process. They not only provide proper guidance to the patients in choosing the correct path of the treatment, but also play a key role in organising and maintaining a cost-effective multidisciplinary rehabilitation team for the microtia patients. 展开更多
关键词 MICROTIA Congenital aural atresia Implantable hearing aids Bone conduction
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部