Mountain glaciers are sensitive to environment. It is important to acquire ice flow velocities over time for glacier research and hazard forecast. For this paper, cross-correlating of optical images is used to monitor...Mountain glaciers are sensitive to environment. It is important to acquire ice flow velocities over time for glacier research and hazard forecast. For this paper, cross-correlating of optical images is used to monitor ice flow velocities, and an improvement, which is called "moving grid," is made to this method. For this research, two remote-sensing images in a certain glacier area, dur-ing different times are selected. The first image is divided into grids, and we calculated the correlation coefficient of each window in the grid with the window on the second image. The window with the highest correlation coefficient is considered the counter-part one on the first image. The displacement of the two corresponding windows is the movement of the glacier, and it is used to calculate glacier surface velocity. Compared to the traditional way of dividing an image with ascertain grid, this method uses small steps to move the grid from one location to another adjacent location until the whole glacier area is covered in the image, thus in-creasing corresponding point density. We selected a glacier in the Tianshan Mountains for this experiment and used two re-mote-sensing images with a 10-year interval to determine this method.展开更多
AIM: To evaluate the efficacy and safety of orbital decomposition (OD) surgery in combination with horse chestnut seed extract (HCSE), as compared to OD atone, in patients with thyroid-associated ophthalmopathy ...AIM: To evaluate the efficacy and safety of orbital decomposition (OD) surgery in combination with horse chestnut seed extract (HCSE), as compared to OD atone, in patients with thyroid-associated ophthalmopathy (TAO). METHODS: Sixty-two orbits from 62 TAO patients were randomly assigned to OD or OD+HCSE at 1:1 ratio (31 received OD alone, 31 received OD +HCSE). Forty-two orbits from 21 healthy subjects were used as controls. Complete ophthalmic examination and color Doppler flow imaging (CDFI) were performed before surgery and 3mo post-surgery on all 62 orbits from the TAO patients. CDFI were also performed on the 42 control orbits, The effect of OD +HCSE and OD alone on TAO orbits was compared on several endpoints, including superior ophthalmic vein blood flow (SOVBF) parameters, subjective assessment, soft tissue involvement, lid retraction, diplopia, eye movement restriction, degree of exophthalmos, and intraocular pressure. The control orbits were used as reference for the SOVBF parameters. RESULTS: OD surgery with or without HCSE improved SOVBF, symptoms and soft tissue involvement, decreased degree of exophthalmos and intraocular pressure in orbits of TAO patients. The OD +HCSE combination led to significantly better improvement of SOVBF than OD alone. The differences between the reductions of SOVBF in the two groups are 1.26 cmls in max-volecity and 0.52 cm/s in min-voiecity (P〈0.0001). CONCLUSION: SOVBF is significantly reduced in the orbits affected with TAO, indicating that congestion may be an important factor contributing to TAO pathogenesis. OD surgery improves the SOVBF, and combination of HCSE medication and OD surgery further improved venous return than OD surgery alone.展开更多
The effects of the micro-ramps on supersonic turbulent flow over a forward-facing step(FFS) was experimentally investigated in a supersonic low-noise wind tunnel at Mach number 3 using nano-tracer planar laser scatt...The effects of the micro-ramps on supersonic turbulent flow over a forward-facing step(FFS) was experimentally investigated in a supersonic low-noise wind tunnel at Mach number 3 using nano-tracer planar laser scattering(NPLS)and particle image velocimetry(PIV) techniques. High spatiotemporal resolution images and velocity fields of supersonic flow over the testing model were captured. The fine structures and their spatial evolutionary characteristics without and with the micro-ramps were revealed and compared. The large-scale structures generated by the micro-ramps can survive the downstream FFS flowfield. The micro-ramps control on the flow separation and the separation shock unsteadiness was investigated by PIV results. With the micro-ramps, the reduction in the range of the reversal flow zone in streamwise direction is 50% and the turbulence intensity is also reduced. Moreover, the reduction in the average separated region and in separation shock unsteadiness are 47% and 26%, respectively. The results indicate that the micro-ramps are effective in reducing the flow separation and the separation shock unsteadiness.展开更多
The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT...The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF.展开更多
As the gold-standard method for single-cell analysis,flow cytometry enables high-throughput and multiple-parameter characterization of individual biological cells.This review highlights the demands for clinical flow c...As the gold-standard method for single-cell analysis,flow cytometry enables high-throughput and multiple-parameter characterization of individual biological cells.This review highlights the demands for clinical flow cytometry in laboratory hematology(e.g.,diagnoses of minimal residual disease and various types of leukemia),summarizes state-of-the-art clinical flow cytometers(e.g.,FACSLyricTMby Becton Dickinson,DxFLEX by Beckman Coulter),then considers innovative technical improvements in flow cytometry(including quantitative,spectral,and imaging approaches)to address the limitations of clinical flow cytometry in hematology diagnosis.Finally,driven by these clinical demands,future developments in clinical flow cytometry are suggested.展开更多
Gaining a full understanding of the mechanisms of action of natural products as therapeutic agents includes observing the effects of natural products on cellular morphology,because abnormal cellular morphology is an i...Gaining a full understanding of the mechanisms of action of natural products as therapeutic agents includes observing the effects of natural products on cellular morphology,because abnormal cellular morphology is an important aspect of cellular transformations that occur as part of disease states.In this study a set of natural products was examined in search of small molecules that influence the cylindrical morphology of fission yeast Schizosaccharomyces pombe.Imaging flow cytometry of large populations of S.pombe exposed to natural products captured cell images and revealed changes in mean length and aspect ratio of cells.Several natural products were found to alter S.pombe’s morphology relative to control,in terms of elongating cells,shrinking them,or making them more round.These results may facilitate future investigations into methods by which cells establish and maintain specific shapes.展开更多
The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discu...The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation, And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls, The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P〈0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P〈0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS.展开更多
Summary: Whether the localized flow acceleration occurs in the resting stenotie left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left...Summary: Whether the localized flow acceleration occurs in the resting stenotie left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left anterior descending coronary arteries in 45 patients was detected by transthoratio color Doppler echocardiograph and multipoint pulse Doppler spectrums were recorded in the same segment. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was calculated. The ratio ≥1.5 was the cutoff value for the presence of localized acceleration flow. There were 23 patients with localized acceleration flow examined by eehoeardiography. Twenty of them were found to have luminal diameter stenosis (60%-98%) in the left anterior descending coronary arteries by coronary angiography and 3 patients were normal. There were 22 patients without localized acceleration flow examined by eehoeardiography. Eighteen of them had no or %60 stenosis. Four patients had serious stenosis (≥95%) or occluded segments in the left anterior descending coronary arteries on coronary angiography. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was significantly higher in patients with left anterior descending coronary artery stenosis than that in those without stenosis (1.9±0.3 vs 1.3±0.2, P〈0.01) and it correlated significantly with left anterior descending coronary artery stenosis (r=0.77, P〈0.01). The specificity by using the ratio≥1. 5 for stenosis detection was 85.7% (18/ 21), and the sensitivity was 83.3% (20/24). This study demonstrated that local blood flow velocity was increased in the resting stenotie left anterior descending coronary artery. Transthoraeie color Doppler eehoeardiography is a reliable noninvasive method to detect localized acceleration flow in the left anterior descending coronary artery stenosis and it is useful in the noninvasive diagnosis of stenosis in the left anterior descending coronary artery.展开更多
From December 1991 to April 1993, we performed color Doppler flow imaging (CDFI) in 11 patients with parathyroid adenoma, and all cases were confirmed by operation and pathology. In all the parathyroid adenomas,vesse...From December 1991 to April 1993, we performed color Doppler flow imaging (CDFI) in 11 patients with parathyroid adenoma, and all cases were confirmed by operation and pathology. In all the parathyroid adenomas,vessels were clearly revealed at the periphery of the upper pole and/or anterior periphery, where arterial signals were elicited. These arteries had branches into the adenomas and originated from inferior thyroid arteries on the same side in most cases. The internal flow signals were increased markedly as compared to normal thyroid, and high-velocity arterial signals were detected. Because of the thyroid' s rich blood supply and landmark peripheral vessels, CDFI can distinguish parathyroid foci from thyroid nodules, lymph nodes, and normal tissues and provide a sound basis for the diagnosis of small parathyroid foci.展开更多
Coronary artery fistula (CAF) is an abnormal communication between a coronary artery and a cardiac chamber, great vessel,or other vascular structures. The presence of the fistula is usually identified by angiography. ...Coronary artery fistula (CAF) is an abnormal communication between a coronary artery and a cardiac chamber, great vessel,or other vascular structures. The presence of the fistula is usually identified by angiography. In this paper, the diagnosis of left coronary artery-right ventricle fistula was made by color Doppler before angiography? and it was confirmed by surgery.Color Doppler flow imaging is a noninvasive method which can reveal the proximal dilatation, the course and the draining site of CAF.展开更多
Color flow imaging(CFI)ultrasound technique can discover the tumor vascularity and superimposed it to convontional B-mode ultrasonogram in real-time. The flow velocity on spectral Doppler sonogram can be measured by s...Color flow imaging(CFI)ultrasound technique can discover the tumor vascularity and superimposed it to convontional B-mode ultrasonogram in real-time. The flow velocity on spectral Doppler sonogram can be measured by setting the sample volume to any selected site.One hundred and thirty-six patients with solid hepatic space-occupied lesions had been admitted and 113 cases were confirmed by operation and pathology,23 patients were strongly suspected by hepatic angiography (HAA).Ninety nine patients with 109 nodules were finally diagnosed as hepatic cellular carcinoma(HCC).According to color flow distribution pattern,3 kinds of color configuation had been nominated.Tumor vascularity discovered by CFI,especially the arterial blood flow was easy to be recognized,and its emerge rate was quite different between HCC group(94.5%)and hemangioma(HCH)group(17.07%)(P<0.01).Spectral Doppler studies were also carried out in these cases and the detectability of arterial flow in HCC group(95.41%)was much higher than that to HCH group (21. 95%) (P<0. 005).Resistant index(RI)and pulsatile index(PI)could be used to differentiate HCC (>0. 50 and >0.80 respectively)from HCH (P<0.001 and P<0.001 respectively).Arterial-portal(A-P) shunt could also be detected by CFI and spectral Doppler(mostly its Vmax>0.6m/s).The detection rate of A-P shunt was 64% in HCC group,but no case could be detected in HCH group.展开更多
Objective To observe the changes of thrombelastography (TEG) and color Doppler flow imaging (CDFI) in the perioperative period after closed lower limb fracture.Methods Fasting venous blood samples in the morning from ...Objective To observe the changes of thrombelastography (TEG) and color Doppler flow imaging (CDFI) in the perioperative period after closed lower limb fracture.Methods Fasting venous blood samples in the morning from 11 healthy adults were used展开更多
The understanding of the liquid fuel spray and flow field characteristics inside a combustor is crucial for designing a fuel efficient and low emission device.Characterisation of the flow field of a model gas turbine ...The understanding of the liquid fuel spray and flow field characteristics inside a combustor is crucial for designing a fuel efficient and low emission device.Characterisation of the flow field of a model gas turbine liquid swirl burner is performed by using a2-D particle imaging velocimetry(PIV)system.The flow field pattern of an axial flow burner with a fixed swirl intensity is compared under confined and unconfined conditions,i.e.,with and without the combustor wall.The effect of temperature on the main swirling air flow is investigated under open and non-reacting conditions.The result shows that axial and radial velocities increase as a result of decreased flow density and increased flow volume.The flow field of the main swirling flow with liquid fuel spray injection is compared to non-spray swirling flow.Introduction of liquid fuel spray changes the swirl air flow field at the burner outlet,where the radial velocity components increase for both open and confined environment.Under reacting condition,the enclosure generates a corner recirculation zone that intensifies the strength of radial velocity.The reverse flow and corner recirculation zone assists in stabilizing the flame by preheating the reactants.The flow field data can be used as validation target for swirl combustion modelling.展开更多
To report the methods and effect of axial pattern flap on lower limb in repairing deep wounds of heels by using color Doppler flow imaging (CDFI) technique so as to solve the ever before problems that the vessel can n...To report the methods and effect of axial pattern flap on lower limb in repairing deep wounds of heels by using color Doppler flow imaging (CDFI) technique so as to solve the ever before problems that the vessel can not be displayed in designing axial flap.Methods Suitable axial flaps on lower limbs were selected according to the character of the wounds.There were 25 flaps including 10 cases of the distal-based sural neurovascular flap,nine medial sole flap and six medial leg flap.All the axial pattern flaps were designed on the basis of traditional design ways before operation;then,CDFI appliance with high resolution was used to examine the starting spot,exterior diameter,trail and length of the flap’s major artery.The flaps were redesigned according to the results of CDFI and transferred to cover the wounds.In the meantime,both the results of operation and examination were compared.Results The major artery’s starting spot,exterior diameter,trail and anatomic layers were displayed clearly,in consistency with the results of operation.The flaps survived completely and recovered well,with perfect appearance,color and arthral function.Conclusion CDFI is a simple,macroscopic and atraumatic method for designing the axial pattern flap on lower limb,can provide more scientific and accurate evidence for preoperative determination of flap transplantation and is worthy of clinical application.10 refs,4 figs,2 tabs.展开更多
Objective: To summarize the clinical experience of diagnosis and treatment of the testicular tumors.Methods: Retrospective analysis of 42 adult patients with testicular cancers was carried out.Results: Ultrasonography...Objective: To summarize the clinical experience of diagnosis and treatment of the testicular tumors.Methods: Retrospective analysis of 42 adult patients with testicular cancers was carried out.Results: Ultrasonography (B-ultrasound and color Doppler flow imaging) was performed on 37 cases. One case was misdiagnosed. Surgical management was carried out in 42 cases and postoperational radiation therapy or chemotherapy was performed. The 1–5 year postoperative survival rate was totally 100%.Conclusion: B-ultrasound, especially color Doppler flow imaging, with the advantages of noninvasiveness and inexpensiveness was most useful and should be firstly employed in diagnosing the testicular tumor. The favorable prognosis can be obtained if an early diagnosis is made and the early treatment is performed. Key words testicular tumor - B-ultrasound - color Doppler flow imaging展开更多
Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI...Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI). All the patients were verified by laparoscopy, fallopian tube patency examination and ovarian function test. Twenty two healthy women served as controls. The results showed that the difference of resistance index(RI)and pulsatility index (PI) of bilateral ovarian arteries between the infertility and the normal controls had statistical significance ( P <0.01), and the PI showed negative correlation with the thickness of endometrium (left side: r =0.724, P <0.01; right side: r =0.756, P <0.01). The results also showed that CDE was more sensitive than CDFI in displaying the ovarian arteries. It could be concluded that the elevated resistance of ovarian artery during the corpus luteum phase was one of the important factors that resulted in infertility.展开更多
Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high tempora...Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high temporal resolution, low cost, and no radiation exposure. This renders it a preferred imaging modality for several clinical scenarios. This review includes a detailed introduction to imaging modalities, including Brightness-mode ultrasound, color Doppler flow imaging, ultrasound elastography, contrast-enhanced ultrasound, and multi-modal fusion analysis. It provides an overview of the current status and prospects of AI-based radiomics in ultrasound diagnosis, highlighting the application of AI-based radiomics to static ultrasound images, dynamic ultrasound videos, and multi-modal ultrasound fusion analysis.展开更多
Color Doppler flow imaging(CDFI) was performed in 24 patients with Graves' disease and the results were compared with those from 8 patients with Hashimoto's disease, 6 patients with simple diffuse goiter, and ...Color Doppler flow imaging(CDFI) was performed in 24 patients with Graves' disease and the results were compared with those from 8 patients with Hashimoto's disease, 6 patients with simple diffuse goiter, and 15 normal volunteers. All cases were confirmed by clinical, laboratory tests or pathology. CDFI of Graves' disease showed diffuse or localized hypoechoes within the thyroid glands, rich flow signals in the hypoechoes, accelerated flow velocity, and decreased resistance in the superior thyroid arteries(STA) and arteries within the glands. These appearances were characteristic as compared with the controls. The rate of flow in STA of Graves' disease patients was 8 to 10 times higher than that in the normal volunteers. This study demonstrates that CDFI is convenient and efficient as compared with isotope scan and some other laboratory tests, and can be widely used in the diagnosis of Graves' disase.展开更多
Traumatic brain injury is a major cause of death and disability. This is a brief report based on a symposium presentation to the 2014 Chinese Neurotrauma Association Meeting in San Francisco, USA. It covers the work f...Traumatic brain injury is a major cause of death and disability. This is a brief report based on a symposium presentation to the 2014 Chinese Neurotrauma Association Meeting in San Francisco, USA. It covers the work from our laboratory in applying multimodal MRI to study experimental traumatic brain injury in rats with comparisons made to behavioral tests and histology. MRI protocols include structural, perfusion, manganese-enhanced, diffusion-tensor MRI, and MRI of blood-brain barrier integrity and cerebrovascular reactivity.展开更多
基金supported by the National Basic Research Program of China (Grant No. 2009CB723901)863 program (2009AA12Z145)the Chinese Academy of Sciences (kzcx2-yw-301)
文摘Mountain glaciers are sensitive to environment. It is important to acquire ice flow velocities over time for glacier research and hazard forecast. For this paper, cross-correlating of optical images is used to monitor ice flow velocities, and an improvement, which is called "moving grid," is made to this method. For this research, two remote-sensing images in a certain glacier area, dur-ing different times are selected. The first image is divided into grids, and we calculated the correlation coefficient of each window in the grid with the window on the second image. The window with the highest correlation coefficient is considered the counter-part one on the first image. The displacement of the two corresponding windows is the movement of the glacier, and it is used to calculate glacier surface velocity. Compared to the traditional way of dividing an image with ascertain grid, this method uses small steps to move the grid from one location to another adjacent location until the whole glacier area is covered in the image, thus in-creasing corresponding point density. We selected a glacier in the Tianshan Mountains for this experiment and used two re-mote-sensing images with a 10-year interval to determine this method.
文摘AIM: To evaluate the efficacy and safety of orbital decomposition (OD) surgery in combination with horse chestnut seed extract (HCSE), as compared to OD atone, in patients with thyroid-associated ophthalmopathy (TAO). METHODS: Sixty-two orbits from 62 TAO patients were randomly assigned to OD or OD+HCSE at 1:1 ratio (31 received OD alone, 31 received OD +HCSE). Forty-two orbits from 21 healthy subjects were used as controls. Complete ophthalmic examination and color Doppler flow imaging (CDFI) were performed before surgery and 3mo post-surgery on all 62 orbits from the TAO patients. CDFI were also performed on the 42 control orbits, The effect of OD +HCSE and OD alone on TAO orbits was compared on several endpoints, including superior ophthalmic vein blood flow (SOVBF) parameters, subjective assessment, soft tissue involvement, lid retraction, diplopia, eye movement restriction, degree of exophthalmos, and intraocular pressure. The control orbits were used as reference for the SOVBF parameters. RESULTS: OD surgery with or without HCSE improved SOVBF, symptoms and soft tissue involvement, decreased degree of exophthalmos and intraocular pressure in orbits of TAO patients. The OD +HCSE combination led to significantly better improvement of SOVBF than OD alone. The differences between the reductions of SOVBF in the two groups are 1.26 cmls in max-volecity and 0.52 cm/s in min-voiecity (P〈0.0001). CONCLUSION: SOVBF is significantly reduced in the orbits affected with TAO, indicating that congestion may be an important factor contributing to TAO pathogenesis. OD surgery improves the SOVBF, and combination of HCSE medication and OD surgery further improved venous return than OD surgery alone.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11172326 and 11502280)
文摘The effects of the micro-ramps on supersonic turbulent flow over a forward-facing step(FFS) was experimentally investigated in a supersonic low-noise wind tunnel at Mach number 3 using nano-tracer planar laser scattering(NPLS)and particle image velocimetry(PIV) techniques. High spatiotemporal resolution images and velocity fields of supersonic flow over the testing model were captured. The fine structures and their spatial evolutionary characteristics without and with the micro-ramps were revealed and compared. The large-scale structures generated by the micro-ramps can survive the downstream FFS flowfield. The micro-ramps control on the flow separation and the separation shock unsteadiness was investigated by PIV results. With the micro-ramps, the reduction in the range of the reversal flow zone in streamwise direction is 50% and the turbulence intensity is also reduced. Moreover, the reduction in the average separated region and in separation shock unsteadiness are 47% and 26%, respectively. The results indicate that the micro-ramps are effective in reducing the flow separation and the separation shock unsteadiness.
文摘The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF.
基金financial support of the National Natural Science Foundation of China(Grant Nos.61922079,61825107,and 62121003)the Chinese Academy of Sciences(Grant Nos.GJJSTD20210004 and Y201927)the National Key Research and Development Program of China(Grant No.2021YFC2500300).
文摘As the gold-standard method for single-cell analysis,flow cytometry enables high-throughput and multiple-parameter characterization of individual biological cells.This review highlights the demands for clinical flow cytometry in laboratory hematology(e.g.,diagnoses of minimal residual disease and various types of leukemia),summarizes state-of-the-art clinical flow cytometers(e.g.,FACSLyricTMby Becton Dickinson,DxFLEX by Beckman Coulter),then considers innovative technical improvements in flow cytometry(including quantitative,spectral,and imaging approaches)to address the limitations of clinical flow cytometry in hematology diagnosis.Finally,driven by these clinical demands,future developments in clinical flow cytometry are suggested.
基金financial support from the University of North Florida.
文摘Gaining a full understanding of the mechanisms of action of natural products as therapeutic agents includes observing the effects of natural products on cellular morphology,because abnormal cellular morphology is an important aspect of cellular transformations that occur as part of disease states.In this study a set of natural products was examined in search of small molecules that influence the cylindrical morphology of fission yeast Schizosaccharomyces pombe.Imaging flow cytometry of large populations of S.pombe exposed to natural products captured cell images and revealed changes in mean length and aspect ratio of cells.Several natural products were found to alter S.pombe’s morphology relative to control,in terms of elongating cells,shrinking them,or making them more round.These results may facilitate future investigations into methods by which cells establish and maintain specific shapes.
文摘The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation, And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls, The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P〈0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P〈0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS.
文摘Summary: Whether the localized flow acceleration occurs in the resting stenotie left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left anterior descending coronary arteries in 45 patients was detected by transthoratio color Doppler echocardiograph and multipoint pulse Doppler spectrums were recorded in the same segment. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was calculated. The ratio ≥1.5 was the cutoff value for the presence of localized acceleration flow. There were 23 patients with localized acceleration flow examined by eehoeardiography. Twenty of them were found to have luminal diameter stenosis (60%-98%) in the left anterior descending coronary arteries by coronary angiography and 3 patients were normal. There were 22 patients without localized acceleration flow examined by eehoeardiography. Eighteen of them had no or %60 stenosis. Four patients had serious stenosis (≥95%) or occluded segments in the left anterior descending coronary arteries on coronary angiography. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was significantly higher in patients with left anterior descending coronary artery stenosis than that in those without stenosis (1.9±0.3 vs 1.3±0.2, P〈0.01) and it correlated significantly with left anterior descending coronary artery stenosis (r=0.77, P〈0.01). The specificity by using the ratio≥1. 5 for stenosis detection was 85.7% (18/ 21), and the sensitivity was 83.3% (20/24). This study demonstrated that local blood flow velocity was increased in the resting stenotie left anterior descending coronary artery. Transthoraeie color Doppler eehoeardiography is a reliable noninvasive method to detect localized acceleration flow in the left anterior descending coronary artery stenosis and it is useful in the noninvasive diagnosis of stenosis in the left anterior descending coronary artery.
文摘From December 1991 to April 1993, we performed color Doppler flow imaging (CDFI) in 11 patients with parathyroid adenoma, and all cases were confirmed by operation and pathology. In all the parathyroid adenomas,vessels were clearly revealed at the periphery of the upper pole and/or anterior periphery, where arterial signals were elicited. These arteries had branches into the adenomas and originated from inferior thyroid arteries on the same side in most cases. The internal flow signals were increased markedly as compared to normal thyroid, and high-velocity arterial signals were detected. Because of the thyroid' s rich blood supply and landmark peripheral vessels, CDFI can distinguish parathyroid foci from thyroid nodules, lymph nodes, and normal tissues and provide a sound basis for the diagnosis of small parathyroid foci.
文摘Coronary artery fistula (CAF) is an abnormal communication between a coronary artery and a cardiac chamber, great vessel,or other vascular structures. The presence of the fistula is usually identified by angiography. In this paper, the diagnosis of left coronary artery-right ventricle fistula was made by color Doppler before angiography? and it was confirmed by surgery.Color Doppler flow imaging is a noninvasive method which can reveal the proximal dilatation, the course and the draining site of CAF.
文摘Color flow imaging(CFI)ultrasound technique can discover the tumor vascularity and superimposed it to convontional B-mode ultrasonogram in real-time. The flow velocity on spectral Doppler sonogram can be measured by setting the sample volume to any selected site.One hundred and thirty-six patients with solid hepatic space-occupied lesions had been admitted and 113 cases were confirmed by operation and pathology,23 patients were strongly suspected by hepatic angiography (HAA).Ninety nine patients with 109 nodules were finally diagnosed as hepatic cellular carcinoma(HCC).According to color flow distribution pattern,3 kinds of color configuation had been nominated.Tumor vascularity discovered by CFI,especially the arterial blood flow was easy to be recognized,and its emerge rate was quite different between HCC group(94.5%)and hemangioma(HCH)group(17.07%)(P<0.01).Spectral Doppler studies were also carried out in these cases and the detectability of arterial flow in HCC group(95.41%)was much higher than that to HCH group (21. 95%) (P<0. 005).Resistant index(RI)and pulsatile index(PI)could be used to differentiate HCC (>0. 50 and >0.80 respectively)from HCH (P<0.001 and P<0.001 respectively).Arterial-portal(A-P) shunt could also be detected by CFI and spectral Doppler(mostly its Vmax>0.6m/s).The detection rate of A-P shunt was 64% in HCC group,but no case could be detected in HCH group.
文摘Objective To observe the changes of thrombelastography (TEG) and color Doppler flow imaging (CDFI) in the perioperative period after closed lower limb fracture.Methods Fasting venous blood samples in the morning from 11 healthy adults were used
基金Supported by the Ministry of Higher Education Malaysia and Universiti Teknologi Malaysia(Research University Grant Tier-1,Grant No.06H29)Ministry of Science,Technology and Innovation(MOSTI)Malaysia(Grant No.03-01-06-KHAS01)
文摘The understanding of the liquid fuel spray and flow field characteristics inside a combustor is crucial for designing a fuel efficient and low emission device.Characterisation of the flow field of a model gas turbine liquid swirl burner is performed by using a2-D particle imaging velocimetry(PIV)system.The flow field pattern of an axial flow burner with a fixed swirl intensity is compared under confined and unconfined conditions,i.e.,with and without the combustor wall.The effect of temperature on the main swirling air flow is investigated under open and non-reacting conditions.The result shows that axial and radial velocities increase as a result of decreased flow density and increased flow volume.The flow field of the main swirling flow with liquid fuel spray injection is compared to non-spray swirling flow.Introduction of liquid fuel spray changes the swirl air flow field at the burner outlet,where the radial velocity components increase for both open and confined environment.Under reacting condition,the enclosure generates a corner recirculation zone that intensifies the strength of radial velocity.The reverse flow and corner recirculation zone assists in stabilizing the flame by preheating the reactants.The flow field data can be used as validation target for swirl combustion modelling.
文摘To report the methods and effect of axial pattern flap on lower limb in repairing deep wounds of heels by using color Doppler flow imaging (CDFI) technique so as to solve the ever before problems that the vessel can not be displayed in designing axial flap.Methods Suitable axial flaps on lower limbs were selected according to the character of the wounds.There were 25 flaps including 10 cases of the distal-based sural neurovascular flap,nine medial sole flap and six medial leg flap.All the axial pattern flaps were designed on the basis of traditional design ways before operation;then,CDFI appliance with high resolution was used to examine the starting spot,exterior diameter,trail and length of the flap’s major artery.The flaps were redesigned according to the results of CDFI and transferred to cover the wounds.In the meantime,both the results of operation and examination were compared.Results The major artery’s starting spot,exterior diameter,trail and anatomic layers were displayed clearly,in consistency with the results of operation.The flaps survived completely and recovered well,with perfect appearance,color and arthral function.Conclusion CDFI is a simple,macroscopic and atraumatic method for designing the axial pattern flap on lower limb,can provide more scientific and accurate evidence for preoperative determination of flap transplantation and is worthy of clinical application.10 refs,4 figs,2 tabs.
文摘Objective: To summarize the clinical experience of diagnosis and treatment of the testicular tumors.Methods: Retrospective analysis of 42 adult patients with testicular cancers was carried out.Results: Ultrasonography (B-ultrasound and color Doppler flow imaging) was performed on 37 cases. One case was misdiagnosed. Surgical management was carried out in 42 cases and postoperational radiation therapy or chemotherapy was performed. The 1–5 year postoperative survival rate was totally 100%.Conclusion: B-ultrasound, especially color Doppler flow imaging, with the advantages of noninvasiveness and inexpensiveness was most useful and should be firstly employed in diagnosing the testicular tumor. The favorable prognosis can be obtained if an early diagnosis is made and the early treatment is performed. Key words testicular tumor - B-ultrasound - color Doppler flow imaging
文摘Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI). All the patients were verified by laparoscopy, fallopian tube patency examination and ovarian function test. Twenty two healthy women served as controls. The results showed that the difference of resistance index(RI)and pulsatility index (PI) of bilateral ovarian arteries between the infertility and the normal controls had statistical significance ( P <0.01), and the PI showed negative correlation with the thickness of endometrium (left side: r =0.724, P <0.01; right side: r =0.756, P <0.01). The results also showed that CDE was more sensitive than CDFI in displaying the ovarian arteries. It could be concluded that the elevated resistance of ovarian artery during the corpus luteum phase was one of the important factors that resulted in infertility.
基金the National Natural Science Foundation of China,Nos.92159305,92259303,62027901,81930053,and 82272029Beijing Science Fund for Distinguished Young Scholars,No.JQ22013and Excellent Member Project of the Youth Innovation Promotion Association CAS,No.2016124.
文摘Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high temporal resolution, low cost, and no radiation exposure. This renders it a preferred imaging modality for several clinical scenarios. This review includes a detailed introduction to imaging modalities, including Brightness-mode ultrasound, color Doppler flow imaging, ultrasound elastography, contrast-enhanced ultrasound, and multi-modal fusion analysis. It provides an overview of the current status and prospects of AI-based radiomics in ultrasound diagnosis, highlighting the application of AI-based radiomics to static ultrasound images, dynamic ultrasound videos, and multi-modal ultrasound fusion analysis.
文摘Color Doppler flow imaging(CDFI) was performed in 24 patients with Graves' disease and the results were compared with those from 8 patients with Hashimoto's disease, 6 patients with simple diffuse goiter, and 15 normal volunteers. All cases were confirmed by clinical, laboratory tests or pathology. CDFI of Graves' disease showed diffuse or localized hypoechoes within the thyroid glands, rich flow signals in the hypoechoes, accelerated flow velocity, and decreased resistance in the superior thyroid arteries(STA) and arteries within the glands. These appearances were characteristic as compared with the controls. The rate of flow in STA of Graves' disease patients was 8 to 10 times higher than that in the normal volunteers. This study demonstrates that CDFI is convenient and efficient as compared with isotope scan and some other laboratory tests, and can be widely used in the diagnosis of Graves' disase.
文摘Traumatic brain injury is a major cause of death and disability. This is a brief report based on a symposium presentation to the 2014 Chinese Neurotrauma Association Meeting in San Francisco, USA. It covers the work from our laboratory in applying multimodal MRI to study experimental traumatic brain injury in rats with comparisons made to behavioral tests and histology. MRI protocols include structural, perfusion, manganese-enhanced, diffusion-tensor MRI, and MRI of blood-brain barrier integrity and cerebrovascular reactivity.