An acoustic dipole radiation model for magnetoacoustic tomography with magnetic induction (MAT-MI) is pro- posed, based on the analyses of one-dimensional tissue vibration, three-dimensional acoustic dipole radiatio...An acoustic dipole radiation model for magnetoacoustic tomography with magnetic induction (MAT-MI) is pro- posed, based on the analyses of one-dimensional tissue vibration, three-dimensional acoustic dipole radiation and acoustic waveform detection with a planar piston transducer. The collected waveforms provide information about the conductiv- ity boundaries in various vibration intensities and phases due to the acoustic dipole radiation pattern. Combined with the simplified back projection algorithm, the conductivity configuration of the measured layer in terms of shape and size can be reconstructed with obvious border stripes. The numerical simulation is performed for a two-layer cylindrical phantom model and it is also verified by the experimental results of MAT-MI for a tissue-like sample phantom. The proposed model suggests a potential application of conductivity differentiation and provides a universal basis for the further study of conductivity reconstruction for MAT-MI.展开更多
Based on the acoustic radiation theory of a dipole source, the influence of the transducer reception pattern is studied for magnetoacoustic tomography with magnetic induction(MAT-MI). Numerical studies are conducted...Based on the acoustic radiation theory of a dipole source, the influence of the transducer reception pattern is studied for magnetoacoustic tomography with magnetic induction(MAT-MI). Numerical studies are conducted to simulate acoustic pressures, waveforms, and reconstructed images with unidirectional, omnidirectional, and strong directional transducers.With the analyses of equivalent and projection sources, the influences of the model dimension and the layer effect are qualitatively analyzed to evaluate the performance of MAT-MI. Three-dimensional simulation studies show that the strong directional transducer with a large radius can reduce the influences of equivalent sources, projection sources, and the layer effect effectively, resulting in enhanced pressure and improved image contrast, which is beneficial for boundary pressure extraction in conductivity reconstruction. The reconstructed conductivity contrast images present the conductivity boundaries as stripes with different contrasts and polarities, representing the values and directions of the conductivity changes of the scanned layer. The favorable results provide solid evidence for transducer selection and suggest potential practical applications of MAT-MI in biomedical imaging.展开更多
Magneto–acoustic tomography with magnetic induction(MAT-MI) is a multiphysics coupled imaging technique that is combined with electrical impedance tomography and ultrasound imaging. In order to study the influence ...Magneto–acoustic tomography with magnetic induction(MAT-MI) is a multiphysics coupled imaging technique that is combined with electrical impedance tomography and ultrasound imaging. In order to study the influence of adding magnetic nanoparticles as a contrast agent for MAT-MI on its physical process, firstly, we analyze and compare the electromagnetic and acoustical properties of MAT-MI theoretically before and after adding magnetic nanoparticles, and then construct a two-dimensional(2 D) planar model. Under the guidance of space-time separation theory, we determine the reasonable simulation conditions and solve the electromagnetic field and sound field physical processes in the two modes by using the finite element method. The magnetic flux density, sound pressure distribution, and related one-dimensional(1 D), 2 D, and three-dimensional(3 D) images are obtained. Finally, we make a qualitative and quantitative analysis based on the theoretical and simulation results. The research results show that the peak time of the time item separated from the sound source has a corresponding relationship with the peak time of the sound pressure signal. At this moment, MAMPTMI produces larger sound pressure signals, and the sound pressure distribution of the MAMPT-MI is more uniform, which facilitates the detection and completion of sound source reconstruction. The research results may lay the foundation for the MAT-MI of magnetically responsive nanoparticle in subsequent experiments and even clinical applications.展开更多
Magnetic induction tomography(MIT) is one of the newest industrial process imaging techniques.Main industrial applications of the MIT imaging are in high conductive flow imaging.However,recently it has been shown that...Magnetic induction tomography(MIT) is one of the newest industrial process imaging techniques.Main industrial applications of the MIT imaging are in high conductive flow imaging.However,recently it has been shown that the MIT may be useful for low conductive process imaging.This paper presents a cost effective hardware design for MIT in industrial applications,called Bath-MKI industrial MIT system.The system comprises 8 inductor coils and has the possibility of expansion to 16 coils.The excitation signals and the measured voltages are generated and measured using a LabView based system.Two 16 by 1 multiplexers are used to select between the coils.Measurements,excitation and multiplexing are all controlled by a National Instrument(NI) USB based DAQ:USB-6259 and a signal generator.Using the same electronics,the prototype is tested with two different coil arrays;one is a small scale ferrite core coil and one larger scale air cored coil.Experimental image reconstruction results are shown using both small scale and large scale coil arrays.展开更多
As a kind of multi-physics imaging approach integrating the advantages of electrical impedance tomography and ul- trasound imaging with the improved spatial resolution and image contrast, magneto-acoustic tomography w...As a kind of multi-physics imaging approach integrating the advantages of electrical impedance tomography and ul- trasound imaging with the improved spatial resolution and image contrast, magneto-acoustic tomography with magnetic induction (MAT-MI) is demonstrated to have the capability of electrical impedance contrast imaging for biological tissues with conductivity differences. By being detected with a strong directional transducer, abrupt pressure change is proved to be generated by the gradient of the induced Lorentz force along the force direction at conductivity boundary. A simplified boundary normal pressure (BNP)-based conductivity reconstruction algorithm is proposed and the formula for conductivity distribution inside the object with the clear physical meaning of pressure derivative, is derived. Numerical simulations of acoustic pressure and conductivity reconstruction are conducted based on a 2-layer eccentric cylindrical phantom model using Hilbert transform. The reconstructed two-dimensional conductivity images accord well with the model, thus success- fully making up the deficiency of only imaging conductivity boundary in traditional MAT-MI. The proposed method is also demonstrated to have a spatial resolution of one wavelength. This study provides a new method of reconstructing accurate electrical conductivity and suggests the potential applications of MAT-MI in imaging biological tissues with conductivity difference.展开更多
This paper focuses on the key issues of information processing in the new sensing technology-electromagnetic induction tomography and depth theoretical study and experimental simulation have been conducted.In this stu...This paper focuses on the key issues of information processing in the new sensing technology-electromagnetic induction tomography and depth theoretical study and experimental simulation have been conducted.In this study,Labview is used to drive the data acquisition card to control the signal generation and acquisition,and Matlab is used to achieve algorithms such as Fast Fourier Transformation (FFT) algorithm,relevant law algorithm and the classical method algorithm.The simulation results show this software system enables successful digital phase identification and the phase difference resolution of 0.10 can be achieved,which is consistent with theoretical analysis.It can also be seen that software system based on Labview and Matlab is a successful method to identify the phase difference in magnetic induction tomography system,which can meet the measurement needs of sensor nodes,laying the basis for the further development of medical IoT study.展开更多
For the test of rotation speed of high spinning projectile, the general formula of the motional electromotive force (MEMF) of planar magnetic induction coil (PMIC) is derived in case of 3D rotation in a stable mag...For the test of rotation speed of high spinning projectile, the general formula of the motional electromotive force (MEMF) of planar magnetic induction coil (PMIC) is derived in case of 3D rotation in a stable magnetic field. Under a reasona-ble assumption, the MEMF of PMIC is simplified after the aforementioned general formula is used to calculate high spinning PMIC in the geomagnetic field environment. The determination approach of half-cycle is discussed and the method of rotation speed test is studied, and a test is conducted in the paper. The rotation speed curve obtained by the approach in this paper is consistent with the curve by telemetry.展开更多
Metal/carbon nanocomposites have shown great potential as high-performance,low-cost electrocatalysts owing largely to their unique metal-support interactions.These nanocomposites are typically prepared by conventional...Metal/carbon nanocomposites have shown great potential as high-performance,low-cost electrocatalysts owing largely to their unique metal-support interactions.These nanocomposites are typically prepared by conventional pyrolysis that is tedious and energy-intensive.Herein,we report the ultrafast preparation of cobalt/carbon nanocomposites by magnetic induction heating(MIH)of metal organic frameworks within seconds under an inert atmosphere.The resulting samples consist of cobalt nanoparticles encapsulated within defective carbon shells,and effectively catalyze oxygen evolution reaction(OER)in alkaline media.Among the series,the sample prepared at 400 A for 10 s exhibits the best OER performance,needing a low overpotential of+308 mV to reach the current density of 10 mA cm^(−2),along with excellent stability,and even outperforms commercial RuO_(2) at high overpotentials.This is ascribed to the charge transfer between the carbon scaffold and metal nanoparticles.Operando X-ray absorption spectroscopy measurements show that the electrochemically produced CoOOH species is responsible for the high electrocatalytic performance.The results highlight the unique potential of MIH in the development of effective nanocomposite catalysts for electrochemical energy technologies.展开更多
Recent experimental findings have demonstrated the occurrence of superconductivity in Bernal bilayer graphene when induced by a magnetic field.In this study,we conduct a theoretical investigation of the potential pair...Recent experimental findings have demonstrated the occurrence of superconductivity in Bernal bilayer graphene when induced by a magnetic field.In this study,we conduct a theoretical investigation of the potential pairing symmetry within this superconducting system.By developing a theoretical model,we primarily calculate the free energy of the system with p+ip-wave parallel spin pairing,p+ip-wave anti-parallel spin pairing and d+i d-wave pairing symmetry.Our results confirm that the magnetic field is indeed essential for generating the superconductivity.We discover that the p+ip-wave parallel spin pairing leads to a lower free energy for the system.The numerical calculations of the energy band structure,zero-energy spectral function and density of states for each of the three pairing symmetries under consideration show a strong consistency with the free energy results.展开更多
An experimental system has been built to produce and measure the magnetic field in the backward ejected matter during hypervelocity impact. The designs of measurement system and coil, the choice of associated equipmen...An experimental system has been built to produce and measure the magnetic field in the backward ejected matter during hypervelocity impact. The designs of measurement system and coil, the choice of associated equipment, and the system calibration are also described in detail. The measurement of magnetic induction intensity for different given coil positions and azimuth angles are performed with two-stage light-gas gun. On condition that impact velocities are approximately equal and incidence angles are 45°, 60° and 90° respectively, the relationship between average magnetic induction intensity and impact angle at different time spans is obtained. Experimental results show that the average magnetic induction intensity with incidence angle of 90° is larger than those with incidence angles of 45°and 60°.展开更多
Ruthenium has been hailed as a competitive alternative for platinum toward hydrogen evolution reaction(HER),a critical process in electrochemical water splitting.In this study,we successfully prepare metallic Ru nanop...Ruthenium has been hailed as a competitive alternative for platinum toward hydrogen evolution reaction(HER),a critical process in electrochemical water splitting.In this study,we successfully prepare metallic Ru nanoparticles supported on carbon paper by utilizing a novel magnetic induction heating(MIH)method.The samples are obtained within seconds,featuring a Cl-enriched surface that is unattainable via conventional thermal annealing.The best sample within the series shows a remarkable HER activity in both acidic and alkaline media with an overpotential of only-23 and-12 mV to reach the current density of 10 mA/cm^(2),highly comparable to that of the Pt/C benchmark.Theoretical studies based on density functional theory show that the excellent electrocatalytic activity is accounted by the surface metal-Cl species that facilitate charge transfer and downshift the d-band center.Results from this study highlight the unique advantages of MIH in rapid sample preparation,where residual anion ligands play a critical role in manipulating the electronic properties of the metal surfaces and the eventual electrocatalytic activity.展开更多
We performed a controlled synthesis of magnetic carbon nanoparticles (M-CNPs) via co-pyrolysis of glycerol and ferrocene with magnetic induction. The morphology of the synthesized M-CNPs was confirmed by transmissio...We performed a controlled synthesis of magnetic carbon nanoparticles (M-CNPs) via co-pyrolysis of glycerol and ferrocene with magnetic induction. The morphology of the synthesized M-CNPs was confirmed by transmission electron microscopy, and thermogravimetric analysis was used to analyze the carbon and Fe contents. M-CNPs that responded to magnetic stimulation were also examined with an AC-magnetic susceptibility analyzer. Our investigations on the influence of synthesis temperature in the range 700-1000℃ suggested that for an initial glycerol to ferrocene weight ratio of 3:1 and a temperature of 800 ℃ gave the highest yield of M-CNPs. Comparing the synthesis with and without magnetic induction, the controlled synthesis under the influence of magnetic induction shows promise as a method for producing high quality M-CNPs in high yields.展开更多
The motion of electron wave packets of a metal is examined classically in the presence of the magnetic field with the aim to calculate the time intervals between two states lying on the same Fermi surface. A lower lim...The motion of electron wave packets of a metal is examined classically in the presence of the magnetic field with the aim to calculate the time intervals between two states lying on the same Fermi surface. A lower limiting value of the transition time equal to about 10–18 sec is estimated as an average for the case when the states are lying on the Fermi surface having a spherical shape. Simultaneously, an upper limit for the electron circular frequency in a metal has been also derived. A formal reference of the classical transition time to the time interval entering the energy-time uncertainty relations known in quantum mechanics is obtained.展开更多
In order to investigate the effect of magnetic field on the liquid-liquid extraction, the extraction in the acetone-water-trichloroethane system was studied under magnetic field with different magnetic induction inten...In order to investigate the effect of magnetic field on the liquid-liquid extraction, the extraction in the acetone-water-trichloroethane system was studied under magnetic field with different magnetic induction intensity.The results showed that the effect of magnetic field was positive in the extraction process, and the partition coeffi-cient and the yield of acetone increased-with the increasing magnetic induction intensity by 5.16%-8.35% and 1.85%-5.70% respectively. The effect of magnetic field on the extraction was intensified when the temperature became, higher. The experimental data of the partition coefficient of acetone were correlated by the method of least square in terms of a power-law correlation.展开更多
Results of magnetic field investigation in a Kaiser type caster show that magnetic induction decays rapidly on moving inward from the outer surface and is almost doubled near corner.In the presence of screenings magne...Results of magnetic field investigation in a Kaiser type caster show that magnetic induction decays rapidly on moving inward from the outer surface and is almost doubled near corner.In the presence of screenings magnetic field strength is attenuated near periphery,but it isn't influenced within the interior.The resultant electromagnetic pressure balances with static head of liquid column,i.e,the upper magnetic induction is smaller than the lower's.However»the maximum pressure moves downward about 1 cm from half height of inductor.展开更多
The article designs a new type of bridge circuit with a controlled source—when the resistance on the bridge arm of the controlled source bridge circuit meets the bridge balance condition, and the bridge branch contai...The article designs a new type of bridge circuit with a controlled source—when the resistance on the bridge arm of the controlled source bridge circuit meets the bridge balance condition, and the bridge branch contains only one Current-Controlled Current Source (CCCS), a Voltage-Controlled Current Source (VCCS), a Current-Controlled Voltage Source (CCVS), or a Voltage-Controlled Voltage Source (VCVS), the circuit is called a controlled bridge circuit, which has the characteristics of bridge balance. Due to the relationship between the controlled source and the bridge arm, the sensitivity of the components on the bridge is higher mathematically and logically. When applied to measurement, engineering, automatic control, and other fields, the controlled bridge circuit has higher control ac-curacy. Mathematical derivation and simulation results prove the correctness of the bridge balance conclusion and the special properties of this bridge when applied to the measurement field.展开更多
The high grade non-oriented electrical steel sheets containing 3.0%Si were manufacturing processed using different cutting techniques, then they were stress relief annealed(SRA), the profiles and textures of the cut...The high grade non-oriented electrical steel sheets containing 3.0%Si were manufacturing processed using different cutting techniques, then they were stress relief annealed(SRA), the profiles and textures of the cutting edges were compared before and after annealing, and the magnetic properties of these specimens were tested and compared. The experimental results show that the iron loss of the specimen by water jet cutting is the lowest, but the magnetic induction under the low magnetic field is the highest, the iron loss of the specimen by laser cutting is the highest, but the magnetic induction under the low magnetic field is the lowest. It is necessary to adopt suitable production conditions and minimize the deterioration involved, and the magnetic property can be recovered by SRA effectively.展开更多
Although the significant roles of magnetic induction and electromagnetic radiation in the neural system have been widely studied,their influence on Parkinson’s disease(PD)has yet to be well explored.By virtue of the ...Although the significant roles of magnetic induction and electromagnetic radiation in the neural system have been widely studied,their influence on Parkinson’s disease(PD)has yet to be well explored.By virtue of the magnetic flux variable,this paper studies the transition of firing patterns induced by magnetic induction and the regulation effect of external magnetic radiation on the firing activities of the subthalamopallidal network in basal ganglia.We find:(i)The network reproduces five typical waveforms corresponding to the severity of symptoms:weak cluster,episodic,continuous cluster,episodic,and continuous wave.(ii)Magnetic induction is a double-edged sword for the treatment of PD.Although the increase of magnetic coefficient may lead the physiological firing activity to transfer to pathological firing activity,it also can regulate the pathological intensity firing activity with excessiveβ-band power transferring to the physiological firing pattern with weakβ-band power.(iii)External magnetic radiation could inhibit continuous tremulous firing andβ-band power of subthalamic nucleus(STN),which means the severity of symptoms weakened.Especially,the bi-parameter plane of the regulation region shows that a short pulse period of magnetic radiation and a medium level of pulse percentage can well regulate pathological oscillation.This work helps to understand the firing activity of the subthalamopallidal network under electromagnetic effect.It may also provide insights into the mechanisms behind the electromagnetic therapy of PD-related firing activity.展开更多
Experimentally the plateaus characteristic for the integer quantum Hall effect is obtained in vicinity of specific values of the magnetic induction. The paper demonstrates that the ratios of these induction values to ...Experimentally the plateaus characteristic for the integer quantum Hall effect is obtained in vicinity of specific values of the magnetic induction. The paper demonstrates that the ratios of these induction values to carrier concentration in the planar crystalline samples approach systematically the quanta of the magnetic flux important for the behavior of superconductors. Moreover, the same quanta can be deduced from the Landau levels theory and their application in the magnetoresistance theory gives results being in accordance with experiments. The quanta of the magnetic flux similar to those for the integer quantum Hall effect can be obtained also for the fractional quantum Hall effect. This holds on condition the experimental ratio of the magnetic flux to carrier concentration is multiplied by the filling factor of the Landau level.展开更多
3D reticulated ceramics (3DRCs) with the composition containing SrFe12O19-SiC-TiO2 were prepared by a replication process with polyurethane sponges as the template in ceramic slurry. The electrical conductivity, diele...3D reticulated ceramics (3DRCs) with the composition containing SrFe12O19-SiC-TiO2 were prepared by a replication process with polyurethane sponges as the template in ceramic slurry. The electrical conductivity, dielectric and magnetic parameters of 3D reticulated ceramics (3DRCs) were measured with changes in cell size of the sponges, contents in the slurry and sintering temperature in this paper. Discussions about the influential factors of those parameters were focused on their electrical conductivity. The experimental results indicated that the electrical conductivity of 3DRCs raised with the increase of cell size, SiC/SrO 6Fe2O3 with weight ratio and sintering temperature. X-ray diffractions and SEM were used to investigate the relationship between electrical conductivity and sintering temperature. Deoxidizing reactions of SrO 6Fe2O3 caused the increasing electrical conductivity. The real part of permittivity (ε') and imaginary part of permeability (μ') raised with the increase of electrical conductivity (σ). The imaginary part of permittivity (ε') has a maximum at 10o S/cm with the increase of a, and the real part of permeability (μ') changes slightly with the increase of a. When a is at the range of 10-4 S/cm to 10o S/cm (a semi conductive state), both the imagine part of permittivity and permeability raises with increasing a, therefore, the 3DRCs present their high electromagnetic loss properties.展开更多
基金Project supported by the National Basic Research Program of China (Grant No. 2011CB707900), the National Natural Science Foundation of China (Grant No. 10974098), the Natural Science Foundation of Jiangsu Province, China (Grant No. BK2009407), and the Specialized Research Fund for Doctoral Program of High Education of China (Grant No. 20093207120003).
文摘An acoustic dipole radiation model for magnetoacoustic tomography with magnetic induction (MAT-MI) is pro- posed, based on the analyses of one-dimensional tissue vibration, three-dimensional acoustic dipole radiation and acoustic waveform detection with a planar piston transducer. The collected waveforms provide information about the conductiv- ity boundaries in various vibration intensities and phases due to the acoustic dipole radiation pattern. Combined with the simplified back projection algorithm, the conductivity configuration of the measured layer in terms of shape and size can be reconstructed with obvious border stripes. The numerical simulation is performed for a two-layer cylindrical phantom model and it is also verified by the experimental results of MAT-MI for a tissue-like sample phantom. The proposed model suggests a potential application of conductivity differentiation and provides a universal basis for the further study of conductivity reconstruction for MAT-MI.
基金Project supported by the National Basic Research Program of China(Grant No.2011CB707900)the National Natural Science Foundation of China(Grant Nos 11274176 and 11474166)the Priority Academic Program Development of Jiangsu Higher Education Institutions,China
文摘Based on the acoustic radiation theory of a dipole source, the influence of the transducer reception pattern is studied for magnetoacoustic tomography with magnetic induction(MAT-MI). Numerical studies are conducted to simulate acoustic pressures, waveforms, and reconstructed images with unidirectional, omnidirectional, and strong directional transducers.With the analyses of equivalent and projection sources, the influences of the model dimension and the layer effect are qualitatively analyzed to evaluate the performance of MAT-MI. Three-dimensional simulation studies show that the strong directional transducer with a large radius can reduce the influences of equivalent sources, projection sources, and the layer effect effectively, resulting in enhanced pressure and improved image contrast, which is beneficial for boundary pressure extraction in conductivity reconstruction. The reconstructed conductivity contrast images present the conductivity boundaries as stripes with different contrasts and polarities, representing the values and directions of the conductivity changes of the scanned layer. The favorable results provide solid evidence for transducer selection and suggest potential practical applications of MAT-MI in biomedical imaging.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.51507171,and 61427806)
文摘Magneto–acoustic tomography with magnetic induction(MAT-MI) is a multiphysics coupled imaging technique that is combined with electrical impedance tomography and ultrasound imaging. In order to study the influence of adding magnetic nanoparticles as a contrast agent for MAT-MI on its physical process, firstly, we analyze and compare the electromagnetic and acoustical properties of MAT-MI theoretically before and after adding magnetic nanoparticles, and then construct a two-dimensional(2 D) planar model. Under the guidance of space-time separation theory, we determine the reasonable simulation conditions and solve the electromagnetic field and sound field physical processes in the two modes by using the finite element method. The magnetic flux density, sound pressure distribution, and related one-dimensional(1 D), 2 D, and three-dimensional(3 D) images are obtained. Finally, we make a qualitative and quantitative analysis based on the theoretical and simulation results. The research results show that the peak time of the time item separated from the sound source has a corresponding relationship with the peak time of the sound pressure signal. At this moment, MAMPTMI produces larger sound pressure signals, and the sound pressure distribution of the MAMPT-MI is more uniform, which facilitates the detection and completion of sound source reconstruction. The research results may lay the foundation for the MAT-MI of magnetically responsive nanoparticle in subsequent experiments and even clinical applications.
文摘Magnetic induction tomography(MIT) is one of the newest industrial process imaging techniques.Main industrial applications of the MIT imaging are in high conductive flow imaging.However,recently it has been shown that the MIT may be useful for low conductive process imaging.This paper presents a cost effective hardware design for MIT in industrial applications,called Bath-MKI industrial MIT system.The system comprises 8 inductor coils and has the possibility of expansion to 16 coils.The excitation signals and the measured voltages are generated and measured using a LabView based system.Two 16 by 1 multiplexers are used to select between the coils.Measurements,excitation and multiplexing are all controlled by a National Instrument(NI) USB based DAQ:USB-6259 and a signal generator.Using the same electronics,the prototype is tested with two different coil arrays;one is a small scale ferrite core coil and one larger scale air cored coil.Experimental image reconstruction results are shown using both small scale and large scale coil arrays.
基金supported by the National Natural Science Foundation of China(Grant Nos.11474166 and 11604156)the Natural Science Foundation of Jiangsu Province,China(Grant No.BK20161013)+1 种基金the Postdoctoral Science Foundation of China(Grant No.2016M591874)the Priority Academic Program Development of Jiangsu Provincial Higher Education Institutions,China
文摘As a kind of multi-physics imaging approach integrating the advantages of electrical impedance tomography and ul- trasound imaging with the improved spatial resolution and image contrast, magneto-acoustic tomography with magnetic induction (MAT-MI) is demonstrated to have the capability of electrical impedance contrast imaging for biological tissues with conductivity differences. By being detected with a strong directional transducer, abrupt pressure change is proved to be generated by the gradient of the induced Lorentz force along the force direction at conductivity boundary. A simplified boundary normal pressure (BNP)-based conductivity reconstruction algorithm is proposed and the formula for conductivity distribution inside the object with the clear physical meaning of pressure derivative, is derived. Numerical simulations of acoustic pressure and conductivity reconstruction are conducted based on a 2-layer eccentric cylindrical phantom model using Hilbert transform. The reconstructed two-dimensional conductivity images accord well with the model, thus success- fully making up the deficiency of only imaging conductivity boundary in traditional MAT-MI. The proposed method is also demonstrated to have a spatial resolution of one wavelength. This study provides a new method of reconstructing accurate electrical conductivity and suggests the potential applications of MAT-MI in imaging biological tissues with conductivity difference.
文摘This paper focuses on the key issues of information processing in the new sensing technology-electromagnetic induction tomography and depth theoretical study and experimental simulation have been conducted.In this study,Labview is used to drive the data acquisition card to control the signal generation and acquisition,and Matlab is used to achieve algorithms such as Fast Fourier Transformation (FFT) algorithm,relevant law algorithm and the classical method algorithm.The simulation results show this software system enables successful digital phase identification and the phase difference resolution of 0.10 can be achieved,which is consistent with theoretical analysis.It can also be seen that software system based on Labview and Matlab is a successful method to identify the phase difference in magnetic induction tomography system,which can meet the measurement needs of sensor nodes,laying the basis for the further development of medical IoT study.
基金National Key Lab for Electronic Measurement and Technology,North University of China(No.9140C120401080C12)
文摘For the test of rotation speed of high spinning projectile, the general formula of the motional electromotive force (MEMF) of planar magnetic induction coil (PMIC) is derived in case of 3D rotation in a stable magnetic field. Under a reasona-ble assumption, the MEMF of PMIC is simplified after the aforementioned general formula is used to calculate high spinning PMIC in the geomagnetic field environment. The determination approach of half-cycle is discussed and the method of rotation speed test is studied, and a test is conducted in the paper. The rotation speed curve obtained by the approach in this paper is consistent with the curve by telemetry.
基金National Science Foundation(CHE-1900235 and CHE-2003685)TEM,XPS,and Raman studies were conducted as part of a user project at the National Center for Electron Microscopy and Molecular Foundry,Lawrence Berkeley National Laboratory,which is supported by the Office of Science,Office of Basic Energy Sciences,of the U.S.Department of Energy under Contract No.DE-AC02-05CH11231+1 种基金XAS experiments were performed at the Stanford Synchrotron Radiation Lightsource(SSRL),which is supported by the U.S.Department of Energy,Office of Science,Office of Basic Energy Sciences under Contract No.DE-AC02-76SF00515Q.M.L.acknowledges the ECS Joseph W.Richards Summer Fellowship for funding support and the support of a Grant-in-Aid of Research(G20211001-639)from the National Academy of Sciences,administered by Sigma Xi,The Scientific Research Society.
文摘Metal/carbon nanocomposites have shown great potential as high-performance,low-cost electrocatalysts owing largely to their unique metal-support interactions.These nanocomposites are typically prepared by conventional pyrolysis that is tedious and energy-intensive.Herein,we report the ultrafast preparation of cobalt/carbon nanocomposites by magnetic induction heating(MIH)of metal organic frameworks within seconds under an inert atmosphere.The resulting samples consist of cobalt nanoparticles encapsulated within defective carbon shells,and effectively catalyze oxygen evolution reaction(OER)in alkaline media.Among the series,the sample prepared at 400 A for 10 s exhibits the best OER performance,needing a low overpotential of+308 mV to reach the current density of 10 mA cm^(−2),along with excellent stability,and even outperforms commercial RuO_(2) at high overpotentials.This is ascribed to the charge transfer between the carbon scaffold and metal nanoparticles.Operando X-ray absorption spectroscopy measurements show that the electrochemically produced CoOOH species is responsible for the high electrocatalytic performance.The results highlight the unique potential of MIH in the development of effective nanocomposite catalysts for electrochemical energy technologies.
基金Project supported by the National Natural Science Foundation of China (Grant No.12074130)the Natural Science Foundation of Guangdong Province (Grant No.2021A1515012340)。
文摘Recent experimental findings have demonstrated the occurrence of superconductivity in Bernal bilayer graphene when induced by a magnetic field.In this study,we conduct a theoretical investigation of the potential pairing symmetry within this superconducting system.By developing a theoretical model,we primarily calculate the free energy of the system with p+ip-wave parallel spin pairing,p+ip-wave anti-parallel spin pairing and d+i d-wave pairing symmetry.Our results confirm that the magnetic field is indeed essential for generating the superconductivity.We discover that the p+ip-wave parallel spin pairing leads to a lower free energy for the system.The numerical calculations of the energy band structure,zero-energy spectral function and density of states for each of the three pairing symmetries under consideration show a strong consistency with the free energy results.
基金National Natural Science Foundation of China (10772028)Talent Resources Development Special Funds of Shenyang (20081400103009)Doctoral Initiation Special Fund of Shenyang Ligong University
文摘An experimental system has been built to produce and measure the magnetic field in the backward ejected matter during hypervelocity impact. The designs of measurement system and coil, the choice of associated equipment, and the system calibration are also described in detail. The measurement of magnetic induction intensity for different given coil positions and azimuth angles are performed with two-stage light-gas gun. On condition that impact velocities are approximately equal and incidence angles are 45°, 60° and 90° respectively, the relationship between average magnetic induction intensity and impact angle at different time spans is obtained. Experimental results show that the average magnetic induction intensity with incidence angle of 90° is larger than those with incidence angles of 45°and 60°.
基金National Science Foundation,Grant/Award Numbers:CHE-1900235,CHE-2003685Office of Science,Office of Basic Energy Sciences,of the U.S.Department of Energy,Grant/Award Number:DE-AC02-05CH11231+3 种基金U.S.Department of Energy,Office of Science,Office of Basic Energy Sciences,Grant/Award Number:DE-AC02-76SF00515NSF MRI program,Grant/Award Number:AST-1828315Grant-in-Aid of Research,Grant/Award Number:G20211001-639National Academy of Sciences,administered by Sigma Xi,The Scientific Research Society。
文摘Ruthenium has been hailed as a competitive alternative for platinum toward hydrogen evolution reaction(HER),a critical process in electrochemical water splitting.In this study,we successfully prepare metallic Ru nanoparticles supported on carbon paper by utilizing a novel magnetic induction heating(MIH)method.The samples are obtained within seconds,featuring a Cl-enriched surface that is unattainable via conventional thermal annealing.The best sample within the series shows a remarkable HER activity in both acidic and alkaline media with an overpotential of only-23 and-12 mV to reach the current density of 10 mA/cm^(2),highly comparable to that of the Pt/C benchmark.Theoretical studies based on density functional theory show that the excellent electrocatalytic activity is accounted by the surface metal-Cl species that facilitate charge transfer and downshift the d-band center.Results from this study highlight the unique advantages of MIH in rapid sample preparation,where residual anion ligands play a critical role in manipulating the electronic properties of the metal surfaces and the eventual electrocatalytic activity.
文摘We performed a controlled synthesis of magnetic carbon nanoparticles (M-CNPs) via co-pyrolysis of glycerol and ferrocene with magnetic induction. The morphology of the synthesized M-CNPs was confirmed by transmission electron microscopy, and thermogravimetric analysis was used to analyze the carbon and Fe contents. M-CNPs that responded to magnetic stimulation were also examined with an AC-magnetic susceptibility analyzer. Our investigations on the influence of synthesis temperature in the range 700-1000℃ suggested that for an initial glycerol to ferrocene weight ratio of 3:1 and a temperature of 800 ℃ gave the highest yield of M-CNPs. Comparing the synthesis with and without magnetic induction, the controlled synthesis under the influence of magnetic induction shows promise as a method for producing high quality M-CNPs in high yields.
文摘The motion of electron wave packets of a metal is examined classically in the presence of the magnetic field with the aim to calculate the time intervals between two states lying on the same Fermi surface. A lower limiting value of the transition time equal to about 10–18 sec is estimated as an average for the case when the states are lying on the Fermi surface having a spherical shape. Simultaneously, an upper limit for the electron circular frequency in a metal has been also derived. A formal reference of the classical transition time to the time interval entering the energy-time uncertainty relations known in quantum mechanics is obtained.
基金Supported by the Program on Technological Development Plan of Tianjin (No.033180611).
文摘In order to investigate the effect of magnetic field on the liquid-liquid extraction, the extraction in the acetone-water-trichloroethane system was studied under magnetic field with different magnetic induction intensity.The results showed that the effect of magnetic field was positive in the extraction process, and the partition coeffi-cient and the yield of acetone increased-with the increasing magnetic induction intensity by 5.16%-8.35% and 1.85%-5.70% respectively. The effect of magnetic field on the extraction was intensified when the temperature became, higher. The experimental data of the partition coefficient of acetone were correlated by the method of least square in terms of a power-law correlation.
基金Supported by the National Doctoral Program Fund of the State Education Committee of Chinathe key program of the 8th Five-Year Plan of Chinathe Natural Science Foundation of Liaoning Province。
文摘Results of magnetic field investigation in a Kaiser type caster show that magnetic induction decays rapidly on moving inward from the outer surface and is almost doubled near corner.In the presence of screenings magnetic field strength is attenuated near periphery,but it isn't influenced within the interior.The resultant electromagnetic pressure balances with static head of liquid column,i.e,the upper magnetic induction is smaller than the lower's.However»the maximum pressure moves downward about 1 cm from half height of inductor.
文摘The article designs a new type of bridge circuit with a controlled source—when the resistance on the bridge arm of the controlled source bridge circuit meets the bridge balance condition, and the bridge branch contains only one Current-Controlled Current Source (CCCS), a Voltage-Controlled Current Source (VCCS), a Current-Controlled Voltage Source (CCVS), or a Voltage-Controlled Voltage Source (VCVS), the circuit is called a controlled bridge circuit, which has the characteristics of bridge balance. Due to the relationship between the controlled source and the bridge arm, the sensitivity of the components on the bridge is higher mathematically and logically. When applied to measurement, engineering, automatic control, and other fields, the controlled bridge circuit has higher control ac-curacy. Mathematical derivation and simulation results prove the correctness of the bridge balance conclusion and the special properties of this bridge when applied to the measurement field.
基金Funded by the High Technology Research and Development Program of China(2011AA11A238)
文摘The high grade non-oriented electrical steel sheets containing 3.0%Si were manufacturing processed using different cutting techniques, then they were stress relief annealed(SRA), the profiles and textures of the cutting edges were compared before and after annealing, and the magnetic properties of these specimens were tested and compared. The experimental results show that the iron loss of the specimen by water jet cutting is the lowest, but the magnetic induction under the low magnetic field is the highest, the iron loss of the specimen by laser cutting is the highest, but the magnetic induction under the low magnetic field is the lowest. It is necessary to adopt suitable production conditions and minimize the deterioration involved, and the magnetic property can be recovered by SRA effectively.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11972292,12172291,and 12072265)the 111 Project(Grant No.BP0719007)。
文摘Although the significant roles of magnetic induction and electromagnetic radiation in the neural system have been widely studied,their influence on Parkinson’s disease(PD)has yet to be well explored.By virtue of the magnetic flux variable,this paper studies the transition of firing patterns induced by magnetic induction and the regulation effect of external magnetic radiation on the firing activities of the subthalamopallidal network in basal ganglia.We find:(i)The network reproduces five typical waveforms corresponding to the severity of symptoms:weak cluster,episodic,continuous cluster,episodic,and continuous wave.(ii)Magnetic induction is a double-edged sword for the treatment of PD.Although the increase of magnetic coefficient may lead the physiological firing activity to transfer to pathological firing activity,it also can regulate the pathological intensity firing activity with excessiveβ-band power transferring to the physiological firing pattern with weakβ-band power.(iii)External magnetic radiation could inhibit continuous tremulous firing andβ-band power of subthalamic nucleus(STN),which means the severity of symptoms weakened.Especially,the bi-parameter plane of the regulation region shows that a short pulse period of magnetic radiation and a medium level of pulse percentage can well regulate pathological oscillation.This work helps to understand the firing activity of the subthalamopallidal network under electromagnetic effect.It may also provide insights into the mechanisms behind the electromagnetic therapy of PD-related firing activity.
文摘Experimentally the plateaus characteristic for the integer quantum Hall effect is obtained in vicinity of specific values of the magnetic induction. The paper demonstrates that the ratios of these induction values to carrier concentration in the planar crystalline samples approach systematically the quanta of the magnetic flux important for the behavior of superconductors. Moreover, the same quanta can be deduced from the Landau levels theory and their application in the magnetoresistance theory gives results being in accordance with experiments. The quanta of the magnetic flux similar to those for the integer quantum Hall effect can be obtained also for the fractional quantum Hall effect. This holds on condition the experimental ratio of the magnetic flux to carrier concentration is multiplied by the filling factor of the Landau level.
文摘3D reticulated ceramics (3DRCs) with the composition containing SrFe12O19-SiC-TiO2 were prepared by a replication process with polyurethane sponges as the template in ceramic slurry. The electrical conductivity, dielectric and magnetic parameters of 3D reticulated ceramics (3DRCs) were measured with changes in cell size of the sponges, contents in the slurry and sintering temperature in this paper. Discussions about the influential factors of those parameters were focused on their electrical conductivity. The experimental results indicated that the electrical conductivity of 3DRCs raised with the increase of cell size, SiC/SrO 6Fe2O3 with weight ratio and sintering temperature. X-ray diffractions and SEM were used to investigate the relationship between electrical conductivity and sintering temperature. Deoxidizing reactions of SrO 6Fe2O3 caused the increasing electrical conductivity. The real part of permittivity (ε') and imaginary part of permeability (μ') raised with the increase of electrical conductivity (σ). The imaginary part of permittivity (ε') has a maximum at 10o S/cm with the increase of a, and the real part of permeability (μ') changes slightly with the increase of a. When a is at the range of 10-4 S/cm to 10o S/cm (a semi conductive state), both the imagine part of permittivity and permeability raises with increasing a, therefore, the 3DRCs present their high electromagnetic loss properties.