期刊文献+
共找到54,194篇文章
< 1 2 250 >
每页显示 20 50 100
Modified magnetic resonance angiography of the liver using sensitivity encoding in comparison with digital subtraction angiography and CT arterial portography 被引量:1
1
作者 Masahiko Fujii Hideaki Kawamitsu Kazuro Sugimura 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2005年第2期185-191,共7页
BACKGROUND: Over 355 patients have received ortho- topic liver transplantation ( OLT) at this hospital since 1993. Preoperative imaging studies of both hepatic vessels and parenchyma in these recipients bettered surgi... BACKGROUND: Over 355 patients have received ortho- topic liver transplantation ( OLT) at this hospital since 1993. Preoperative imaging studies of both hepatic vessels and parenchyma in these recipients bettered surgical plan- ning or even precluded the necessity of surgery. Here we report our preliminary results of modified magnetic reso- nance angiography ( MRA ) using sensitivity encoding ( SENSE) through comparative study with conventional digital subtraction angiography (DSA) and CT arterial por- tography (CTAP). METHODS: Sixteen patients with suspected liver diseases were included in the study. All of them received both dy- namic MRI of the liver using SENSE and digital DSA with CTAP within a two-week interval. The four-phase MRA was reconstructed from source images of the coronal dy- namic study. The arterial phase of the modified MRA was compared with DSA in the evaluation of hepatic arteries and the portal phase compared with CT portography recon- structed from source images of CTAP. In dynamic study of the liver, a fixed dose (20 ml) of contrast medium and scan timing were used. RESULTS: The main branches and variations of the hepatic arterial system were well shown on the modified MRA, al- though the marginal branches of hepatic arteries were of poor quality. The figures of portal veins on MRA were as clear as or superior to those of CTAP. In addition, the su- prarenal inferior vena cava (IVC) was well demonstrated on MRA and/or non contrast-enhanced coronal balanced fast-field echo (b-FFE) scan sequence in most cases. MRI detected most parenchymal lesions of the liver and hemo- dynamics of these lesions could be evaluated on source ima- ges of the modified MRA. MRI/MRA also serendipitously revealed several extrahepatic disease entities or variations that were not found on DSA/CTAP. CONCLUSIONS: The modified MRA using SENSE is a cost-effective modality of examination for the demonstra- tion of the whole hepatic vascular system. Combined with MRI, it has the potential as a one-stop imaging modality in the preoperative evaluation in fields such as OLT. 展开更多
关键词 orthotopic liver transplantation magnetic resonance imaging magnetic resonance angiography digital subtraction angiography
下载PDF
Cerebral blood flow volume measurements of the carotid artery and ipsilateral branches using two-dimensional phase-contrast magnetic resonance angiography
2
作者 Gang Guo Yonggui Yang Weiqun Yang 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第30期2367-2371,共5页
The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC ... The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encoding was set to 80 cm/s. Results of the measurements showed that the error rate was 7.0±6.0% in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateral common carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. In addition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore, after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accurate in the determination of BFV in the carotid arteries. 展开更多
关键词 two-dimensional phase-contrast magnetic resonance angiography blood flow three-dimensional time-of-flight phase-contrast magnetic resonance angiography internal carotid artery common carotid artery external carotid artery velocity encoding
下载PDF
Magnetic resonance angiography in the mana-gement of patients with portal hypertension 被引量:9
3
作者 Hua Liu, Hui Cao and Zhi-Yong Wu Shanghai, China Department of General Surgery, Renji Hospital, Shanghai Second Medical University, Shanghai 200127, China 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2005年第2期239-243,共5页
BACKGROUND: In recent years, MR techniques have been widely used for displaying hepatic vessels and measuring its hemodynamics, especially in the management of the patients with portal hypertension. The aim of this st... BACKGROUND: In recent years, MR techniques have been widely used for displaying hepatic vessels and measuring its hemodynamics, especially in the management of the patients with portal hypertension. The aim of this study was to eva- luate the role of magnetic resonance angiography (MRA) in the treatment of patients with portal hypertension. METHODS: A series of 38 patients with portal hypertension and 12 control patients were enrolled in this study. Three dimensional dynamic contrast-enhanced (3D-DCE) MRA and two dimensional phase-contrast (2D-PC) MR were used for the study of portal venous anatomy and its hemo- dynamics, which were compared with those of indirect portal-venography (IPVG) and doppler ultrasonography (DUS). RESULTS: The anatomical imaging of the portal venous system could be displayed clearly in 3D-DCE MRA and the imaging quality of MRA was better than that of IPVG. The hemodynamic information from 2D-PC MR was closely re- lated to that from DUS. CONCLUSIONS: As a non-invasive technique, MRA can display the anatomy of the portal venous system clearly and measure its hemodynamics exactly. It is very useful and can be applied if necessary in the management of patients with portal hypertension. 展开更多
关键词 portal hypertension clinical application magnetic resonance angiography
下载PDF
Celiomesenteric trunk demonstrated by 3-dimensional contrast-enhanced magnetic resonance angiography 被引量:2
4
作者 Jiang Lin Author Affiliations:Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai 200032, China (Lin J) 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2005年第3期472-474,共3页
Celiomesenteric trunk is a rare vascular anomaly, which has significant clinical implications. 3-di-mensional contrast-enhanced magnetic resonance angiography (3D CE MRA) is a new imaging modality, non-invasive , fast... Celiomesenteric trunk is a rare vascular anomaly, which has significant clinical implications. 3-di-mensional contrast-enhanced magnetic resonance angiography (3D CE MRA) is a new imaging modality, non-invasive , fast and easy to perform. We describe a patient with a common celiomesenteric trunk demonstrated by 3D CE MRA. METHODS: A 45-year-old man was subjected to 3D CE MRA before transarterial chemoembolization (TACE) for hepatocellular carcinoma. The examination was performed on a 1.5T MR imager with a body coil. The contrast medium was gadopentetate dimeglumine. Source images from the hepatic arterial phase acquisition were reconstructed into MRA images. Intra-arterial digital subtraction angiography (DSA) during TACE was carried out 3 days after 3D CE MRA. RESULTS:On 3D CE MRA, a common trunk of the celiac and superior mesenteric artery was clearly depicted. The origin and course of the hepatic, splenic and superior mesenteric arteries were also visualized. These findings were confirmed by intra-arterial DSA. CONCLUSIONS: Celiomesenteric trunk can be well delineated by 3D CE MRA. The image is correlated precisely with that from DSA. 展开更多
关键词 celiomesenteric trunk magnetic resonance angiography
下载PDF
Three-dimensional time-of-flight magnetic resonance angiography combined with high resolution T2-weighted imaging in preoperative evaluation of microvascular decompression 被引量:2
5
作者 Chen Liang Ling Yang +2 位作者 Bin-Bin Zhang Shi-Wen Guo Rui-Chun Li 《World Journal of Clinical Cases》 SCIE 2022年第34期12594-12604,共11页
BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and H... BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and HFS caused by NVC. The judgement of NVC is a critical step in the preoperative evaluation of MVD, which is related to the effect of MVD treatment. Magnetic resonance imaging(MRI) technology has been used to detect NVC prior to MVD for several years. Among many MRI sequences, three-dimensional time-of-flight magnetic resonance angiography(3D TOF MRA) is the most widely used. However, 3D TOF MRA has some shortcomings in detecting NVC. Therefore, 3D TOF MRA combined with high resolution T2-weighted imaging(HR T2WI) is considered to be a more effective method to detect NVC.AIM To determine the value of 3D TOF MRA combined with HR T2WI in the judgment of NVC, and thus to assess its value in the preoperative evaluation of MVD.METHODS Related studies published from inception to September 2022 based on PubMed, Embase, Web of Science, and the Cochrane Library were retrieved. Studies that investigated 3D TOF MRA combined with HR T2WI to judge NVC in patients with TN or HFS were included according to the inclusion criteria. Studies without complete data or not relevant to the research topics were excluded. The Quality Assessment of Diagnostic Accuracy Studies checklist was used to assess the quality of included studies. The publication bias of the included literature was examined by Deeks’ test. An exact binomial rendition of the bivariate mixed-effects regression model was used to synthesize data. Data analysis was performed using the MIDAS module of statistical software Stata 16.0. Two independent investigators extracted patient and study characteristics, and discrepancies were resolved by consensus. Individual and pooled sensitivities and specificities were calculated. The I_(2) statistic and Q test were used to test heterogeneity. The study was registered on the website of PROSERO(registration No. CRD42022357158).RESULTS Our search identified 595 articles, of which 12(including 855 patients) fulfilled the inclusion criteria. Bivariate analysis showed that the pooled sensitivity and specificity of 3D TOF MRA combined with HR T2WI for detecting NVC were 0.96 [95% confidence interval(CI): 0.92-0.98] and 0.92(95%CI: 0.74-0.98), respectively. The pooled positive likelihood ratio was 12.4(95%CI: 3.2-47.8), pooled negative likelihood ratio was 0.04(95%CI: 0.02-0.09), and pooled diagnostic odds ratio was 283(95%CI: 50-1620). The area under the receiver operating characteristic curve was 0.98(95%CI: 0.97-0.99). The studies showed no substantial heterogeneity(I2 = 0, Q = 0.001 P = 0.50).CONCLUSION Our results suggest that 3D TOF MRA combined with HR T2WI has excellent sensitivity and specificity for judging NVC in patients with TN or HFS. This method can be used as an effective tool for preoperative evaluation of MVD. 展开更多
关键词 Three-dimensional time-of-flight magnetic resonance angiography High resolution T2 weighted imaging Neurovascular compression Microvascular decompression META-ANALYSIS
下载PDF
Validation of hyperintense middle cerebral artery sign in acute ischemic stroke Comparison between magnetic resonance imaging and angiography 被引量:5
6
作者 Gang Guo Yonggui Yang Weiqun Yang 《Neural Regeneration Research》 SCIE CAS CSCD 2012年第3期229-234,共6页
We performed a retrospective analysis of non-contrast computed tomography (CT) scans, immediately subsequent magnetic resonance imaging (MRI), and cerebral angiography data from 30 consecutive patients with acute ... We performed a retrospective analysis of non-contrast computed tomography (CT) scans, immediately subsequent magnetic resonance imaging (MRI), and cerebral angiography data from 30 consecutive patients with acute ischemic stroke within 6 hours after symptom onset. Results showed that eleven patients developed subsequent hemorrhagic transformation at follow-up. A hyperintense middle cerebral artery sign on MRI was found in six hemorrhagic patients, all of who had acute thrombosis formation on magnetic resonance angiography and digital subtraction angiography. No patients in the non-hemorrhagic group had hyperintense middle cerebral artery sign on MRI. The sensitivity, specificity, and positive predictive values of the hyperintense middle cerebral artery sign on MRI T1-weighted image for subsequent hemorrhagic transformation were 54.5%, 100%, and 100% respectively. Hyperdense middle cerebral artery sign on non-contrast CT was observed in nine patients, five of who developed hemorrhagic transformation. These data suggest that hyperintense middle cerebral artery sign on MRI T1-weighted image is a highly specific and moderately sensitive indicator of subsequent hemorrhagic transformation in patients after acute ischemic stroke, and its specificity is superior to CT. 展开更多
关键词 STROKE hemorrhagic transformation magnetic resonance imaging angiography
下载PDF
Magnetic resonance angiography for the primary diagnosis of pulmonary embolism: A review from the international workshop for pulmonary functional imaging 被引量:4
7
作者 Nanae Tsuchiya Edwin JR van Beek +8 位作者 Yoshiharu Ohno Hiroto Hatabu Hans-Ulrich Kauczor Andrew Swift Jens Vogel-Claussen Jürgen Biederer James Wild Mark O Wielpütz Mark L Schiebler 《World Journal of Radiology》 CAS 2018年第6期52-64,共13页
Pulmonary contrast enhanced magnetic resonance angiography(CE-MRA) is useful for the primary diagnosis of pulmonary embolism(PE). Many sites have chosen not to use CE-MRA as a first line of diagnostic tool for PE beca... Pulmonary contrast enhanced magnetic resonance angiography(CE-MRA) is useful for the primary diagnosis of pulmonary embolism(PE). Many sites have chosen not to use CE-MRA as a first line of diagnostic tool for PE because of the speed and higher efficacy of computerized tomographic angiography(CTA). In this review, we discuss the strengths and weaknesses of CEMRA and the appropriate imaging scenarios for the primary diagnosis of PE derived from our unique multiinstitutional experience in this area. The optimal patient for this test has a low to intermediate suspicion for PE based on clinical decision rules. Patients in extremis are not candidates for this test. Younger women(< 35 years of age) and patients with iodinated contrast allergies are best served by using this modality We discuss the history of the use of this test, recent technical innovations, artifacts, direct and indirect findings for PE, ancillary findings, and the effectiveness(patient outcomes) of CE-MRA for the exclusion of PE. Current outcomes data shows that CE-MRA and NM V/Q scans are effective alternative tests to CTA for the primary diagnosis of PE. 展开更多
关键词 Female Lung Neoplasms HYPERSENSITIVITY PULMONARY EMBOLISM magnetic resonance angiography Radiation induced Outcome assessment(health care) ARTIFACTS COMPUTERIZED tomography angiography
下载PDF
Comparison of 16 slice multi-detector computed tomography and breath hold 3D magnetic resonance angiography in the detection of coronary stenosis 被引量:2
8
作者 Xin LIU Zulong CAI Youquan CAI Shaohong ZHAO Ningyu AN Yuangui GAO 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2006年第1期24-28,共5页
Objective To compare 16-slice multi-detector spiral computed tomography (MDCT) and breathhold 3D magnetic resonance (MR) coronary angiography in the visualization of coronary arteries and the accuracy of detecting sig... Objective To compare 16-slice multi-detector spiral computed tomography (MDCT) and breathhold 3D magnetic resonance (MR) coronary angiography in the visualization of coronary arteries and the accuracy of detecting significant (> 50%) coronary stenoses in patients with suspected coronary artery disease. Methods Forty patients were examined by 16-slice CT (GE, Lightspeedl6)and MR (GE,Twinspeed) within 3 days; 31 of them underwent conventional coronary angiography (CAG) within 2 weeks after CT and MR scan. CT was performed with 16× 1.25 mm detector collimation, 0.5 s rotation time and images were reconstructed at 60%-75% of the cardiac cycle. MR was performed with breath hold 3D FIESTA (TR4.0 ms, TE1.7 ms, flip angle 65, slice thickness 3 mm, FOV 280 mm, matrix 256× 192). Mean heart rate was 63 ± 5.8 bpm and β-blocker was used in 24 patients. MR and CT image quality was evaluated in 9 coronary segments (RCA1, RCA2, RCA3, LM, LAD1, LAD2, LAD3, LCX1, LCX2) using a four-point grading scale.Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated for detection of significant stenosis using CAG as the gold standard. Results 16-slice CT showed higher image quality in most coronary segments except RCA2.Forty-three segments were diagnosed as significant stenosis by CAG, 36 and 27 of these were correctly detected by CT and MR respectively. Sensitivity, specificity, positive predictive value, and negative predictive value of 16-slice CT and MR for detecting significant stenosis were 83 %, 84 %, 49 %, 97 % and 63 %, 90 %, 55 %, 93 %, respectively. Conclusion Sixteen-slice CT showed higher image quality in most coronary segments excepted for middle RCA. 16-slice CT had higher sensitivity than MR for detection of coronary significant stenosis, whereas MR had higher specificity than CT. Both CT and MR showed high negative predictive value,which is useful for excluding coronary stenosis in symptomatic patients. 展开更多
关键词 COMPUTED TOMOGRAPHY magnetic resonance imaging CORONARY ARTERY disease angiography
下载PDF
Diagnostic Accuracy of Three-Dimensional Whole-Heart Magnetic Resonance Angiography to Detect Coronary Artery Disease with Invasive Coronary Angiography as a Reference:A Meta-Analysis 被引量:3
9
作者 Shiqin Yu Chen Cui +1 位作者 Minjie Lu Shihua Zhao 《Cardiovascular Innovations and Applications》 2020年第1期173-184,共12页
Objective:We aimed to evaluate the diagnostic performance of three-dimensional whole-heart magnetic resonance coronary angiography(MRCA)in detecting coronary artery disease(CAD)with invasive coronary angiography as th... Objective:We aimed to evaluate the diagnostic performance of three-dimensional whole-heart magnetic resonance coronary angiography(MRCA)in detecting coronary artery disease(CAD)with invasive coronary angiography as the reference standard.Methods:We searched PubMed and Embase for studies evaluating the diagnostic performance of three-dimensional whole-heart MRCA for the diagnosis of CAD with invasive coronary angiography as the reference standard.The bivariate mixed-effects regression model was applied to synthesize available data.The clinical utility of whole-heart MRCA was calculated by the posttest probability based on Bayes’s theorem.Results:Eighteen studies were included,of which 16 provided data at the artery level.Patient-based analysis revealed a pooled sensitivity of 0.90(95%confi dence interval[CI]0.87–0.93)and specifi city of 0.79(95%CI 0.73–0.84),while the pooled estimates were 0.86(95%CI 0.82–0.89)and 0.89(95%CI 0.84–0.92),respectively,at the artery level.The areas under the summary receiver operating characteristic curve were 0.93(95%CI 0.90–0.95)and 0.92(95%CI 0.90–0.94)at the patient and artery levels,respectively.With a pretest probability of 50%,the patients’posttest probabilities of CAD were 81%for positive results and 11%for negative results.Conclusions:Whole-heart MRCA can be an alternative noninvasive method for diagnosis and assessment of CAD. 展开更多
关键词 magnetic resonance CORONARY angiography whole-heart CORONARY artery disease INVASIVE CORONARY angiography
下载PDF
Study of utility of 2.0T-SGR magnetic resonance angiography in cerebrovascular disease 被引量:1
10
作者 董其龙 钱根年 +6 位作者 郑春雨 王锦良 肖慧 季洪兵 钟群 马明 李铭山 《中国临床康复》 CSCD 2003年第6期1042-1043,T004,共3页
AIM:To evaluate the clinical value of 2.0T SGR magnetic resonance angiography.METHODS:Using Elscint 2.0T SGR MR to scan 62 patients with cerebrovascular disease.Three dimensional models were reconstructed by 3D TOF wi... AIM:To evaluate the clinical value of 2.0T SGR magnetic resonance angiography.METHODS:Using Elscint 2.0T SGR MR to scan 62 patients with cerebrovascular disease.Three dimensional models were reconstructed by 3D TOF with 3D PC and treated with maximal intensity projection (MIP).RESULTS:MRA can clearly display normal vessel form and lesions.In these cases,there were 26 arteriovenous malformation (AVM) cases,12 intracranial aneurysm cases,7 moy moya disease cases and 18 arteriosclerosis and arterial occlusion cases.CONCLUSION:2.0T SGR MRA is a noninvasive and effective angiography method to diagnose vascular disease with clear localization and high final diagnosis rate. 展开更多
关键词 磁共振 血管成象 脑血管疾病 应用
下载PDF
Optimal velocity encoding during measurement of cerebral blood flow volume using phase-contrast magnetic resonance angiography
11
作者 Gang Guo Yonggui Yang Weiqun Yang 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第23期1796-1800,共5页
This study investigated the effect of velocity encoding on measurement of brain blood flow and blood volume of inflow and outflow using phase-contrast magnetic resonance angiography. A single two-dimensional phase-con... This study investigated the effect of velocity encoding on measurement of brain blood flow and blood volume of inflow and outflow using phase-contrast magnetic resonance angiography. A single two-dimensional phase-contrast magnetic resonance angiography slice was applied perpendicular to the internal carotid artery and the vertebral artery at C2 level. For each subject, the velocity encoding was set from 30 to 90 cm/s with an interval of 10 cm/s for a total of seven settings. Various velocity encodings greatly affected blood flow volume, maximal blood flow velocity and mean blood flow velocity in the internal carotid artery, but did not significantly affect vertebral arteries and jugular veins. When velocity encoding was 60-80 cm/s, the inflow blood volume was 655 _+ 118 mL/min, and the outflow volume was 506 _+ 186 mL/min. The ratio of outflow/inflow was steady at 0.78-0.83, and there was no aliasing in any of the images. These findings suggest that velocity encodings of 60 80 cm/s should be selected during measurement of cerebral blood flow volume using phase-contrast magnetic resonance angiography. 展开更多
关键词 cerebral blood flow velocity encoding PHASE-CONTRAST magnetic resonance imaging
下载PDF
Gadobutrol at different injection rates for dynamic supra-aortic imaging by contrast-enhanced magnetic resonance angiography
12
作者 范兵g 王霄英 +3 位作者 LI Miao ZHANG Yu-dong ZHANG Bao-cui LUO Jian 《Journal of Chongqing University》 CAS 2013年第4期147-154,共8页
The aim of this study was to compare differences in imaging quality at different injection rates of gadobutrol(Gadovist? 1.0M) for dynamic supra-aortic imaging by contrast-enhanced magnetic resonance angiography(CEM R... The aim of this study was to compare differences in imaging quality at different injection rates of gadobutrol(Gadovist? 1.0M) for dynamic supra-aortic imaging by contrast-enhanced magnetic resonance angiography(CEM RA). In 6 healthy volunteers,dynamic CEM RA examinations were performed twice at a 7 d interval with a gadobutrol dose of 0.1 mmol given to 1 kg body mass. For the two examinations,the contrast medium was injected at rates of 1.5 mL/s and 2.0 mL/s,followed by 20 mL normal saline injected at the same rate. Using a GE Signa 3.0T M R apparatus and the time-resolved imaging of contrast kinetics(TRICKS) technique,scanning was performed continuously for 15 phases at a time resolution of about 2.4 s. Vascular reconstruction was undertaken by multiplane reconstruction and maximum intensity projection techniques. Two radiologists experienced in CEM RA diagnosis subjectively evaluated the contrast effect,vascular detail,and pseudo-shadow of all images,and graded them via a 5-point scale. With the two drug injection rates,the image quality,peak signal-to-noise ratio(SNR) and contrast-to-noise ratio(CNR) were compared for imaging of the infra-aortic arch,brachiocephalic trunk,subclavian artery(left/right),common carotid artery(left/right),internal carotid artery(left/right),and external carotid artery(left/right). Characteristics of the time-signal-intensity(T-S-I) curves were also analyzed at the two injection rates. All studies were performed successfully,without any complications. There was good image quality with both gadobutrol injection rates of 1.5 mL/s and 2.0 mL/s,and subjective scores for image quality,SNR and CNR were not significantly different between the two rates(P > 0.05). The time-to-peak(TTP) from the hand dorsal vein injection site to the carotid artery ranged from 16.0 s to 27.1 s(mean 21.7 s ±3.4 s) in the 6 subjects,and was also not significantly different between the two drug injection rates(P > 0.05). We conclude that dynamic CEM RA examination of the supra-aortic arch with gadobutrol injection at a rate of 1.5 mL/s was feasible,and satisfactorily reflected vascular shape and dynamic blood flow information. 展开更多
关键词 GADOBUTROL supra-aortic imaging magnetic resonance imaging
下载PDF
The Magnetic Resonance Image and Pathology of Spinal Cord Cavernous Hemangioma
13
作者 TONG Zhi-qin BAI Bin +2 位作者 TONG ZM-chao SONG Guang-yi ZHAO Jing-long 《Journal of Nanjing Medical University》 2002年第4期175-178,共4页
Objective To investigate the characteristics of magnetic resonance image (MRI) of spinal cord cavernous hemangioma. Methods Six cases of spinal cord cavernous heman-gioma diagnosed by MRI and confirmed by pathology we... Objective To investigate the characteristics of magnetic resonance image (MRI) of spinal cord cavernous hemangioma. Methods Six cases of spinal cord cavernous heman-gioma diagnosed by MRI and confirmed by pathology were reviewed. The characteristics of MRI were analyzed and correlated with pathological characteristics of spinal cord cavernous hemangioma. Results In 4 cases, the tumors were located in thoracic segment of the spinal cord and 2 in cervical cord. All lesions were solitary and the spinal cords were normal or a little thicker. The MRI showed that the images of focus were ball-like popcorn or mulberry with mixed signal,with short T2 signal around the focus. Under microscope, the hemangioma was composed of highly expanded blood sinusoids and its wall was thin and consisted of flat epithelial cells. There were some red blood cells in the cavity of the sinusoid and a little fibrous tissue in the diazoma between blood sinusoids. And also some fresh and old hemorrhages could be seen in the specimen. Conclusion MRI has high sensitivity and specificity in the diagnosis of spinal cavernous hemangioma. 展开更多
关键词 cavernous hemangioma spinal tumor magnetic resonance image PATHOLOGY
下载PDF
Enhancement maximum slope of increase of magnetic resonance angiography in patients with diabetes lower extremity arterial disease and its correlation with endothelial injury and oxidative stress
14
作者 Zhang Hui-Cun 《Journal of Hainan Medical University》 2017年第2期123-126,共4页
Objective:To study the enhancement maximum slope of increase of magnetic resonance angiography in patients with diabetes lower extremity arterial disease and its correlation with endothelial injury and oxidative stres... Objective:To study the enhancement maximum slope of increase of magnetic resonance angiography in patients with diabetes lower extremity arterial disease and its correlation with endothelial injury and oxidative stress.Methods: Patients with diabetes lower extremity arterial disease accepting 3D-CEMRA examination in our hospital between May 2013 and December 2015 were selected as the pathology group, and the enhancement maximum slope of increase was measured;healthy volunteers receiving physical examination in our hospital during the same period were selected as control group, and serum levels of endothelial oxidative stress injury-related molecules of two groups of subjects were determined.Results:The enhancement maximum slope of increase of the lesion-side anterior tibial artery, posterior tibial artery, peroneal artery and dorsalis pedis artery of pathology group were significantly lower than those of the unaffected-side;serum CyPA, ERK1, ERK2, Akt, JAK, HO-1 and CO content of pathology group were significantly higher than those of control group and negatively correlated with the enhancement maximum slope of increase of lower extremity while Prdx6, SOD, CAT, GSH-Px, eNOS and NO content were significantly lower than those of control group and positively correlated with the enhancement maximum slope of increase of lower extremity.Conclusion: The enhancement maximum slope of increase of magnetic resonance angiography significantly reduces in patients with diabetes lower extremity arterial disease and is closely related to oxidative stress-induced endothelial injury as well as eNOS/NO and HO-1/CO system function change. 展开更多
关键词 Type 2 DIABETES MELLITUS MACROVASCULAR complications CONTRAST-ENHANCED magnetic resonance angiography ENDOTHELIAL injury Oxidative stress
下载PDF
Preliminary clinical application using 3D time-resolved imaging of contrast-enhanced MR angiography of contrast kinetics (3D-TRICKS)i
15
作者 YANG Chun-shan 刘士远 +4 位作者 肖湘生 冯云 李惠民 肖珊 龚万庆 《Journal of Medical Colleges of PLA(China)》 CAS 2007年第1期43-48,共6页
Objective:To introduce a new better contrast-enhanced MR angiographic metnod, named 3D time-resolved imaging of contrast kinetics (3D-TRICKS). Methods: TRICKS is a high temporal resolution (2-6 s) MR angiographi... Objective:To introduce a new better contrast-enhanced MR angiographic metnod, named 3D time-resolved imaging of contrast kinetics (3D-TRICKS). Methods: TRICKS is a high temporal resolution (2-6 s) MR angiographic technique using a short TR(4 ms) and TE(1.5 ms), partial echo sampling, in which central part of k-space is updated more frequently than the peripheral part. TRICKS pre-contrast mask 3D images are firstly scanned, and then the bolus injecting of Gd-DTPA, 15-20 sequential 3D images are acquired. The reconstructed 3D images, subtraction of contrast 3D images with mask images, are conceptually similar to a catheter-based intra-arterial digital subtraction angiographic series (DSA). Thirty patients underwent contrast-enhanced MR angiography using 3D-TRICKS. Results: Totally 12 vertebral arteries were well displayed on TRICKS, in which 7 were normal, 1 demonstrated bilateral vertebral artery stenosis, 4 had unilateral vertebral artery stenosis and 1 was accompanied with the same lateral carotid artery bifurcation stenosis. Four cases of bilateral renal arteries were normal, 1 transplanted kidney artery showed as normal and 1 transplanted kidney artery showed stenosis. 2 cerebral arteries were normal, 1 had sagittal sinus thrombosis and 1 displayed intracranial arteriovenous malformation. 3 pulmonary arteries were normal, 1 showed pulmonary artery thrombosis and 1 revealed pulmonary sequestration's abnormal feeding artery and draining vein. One left lower limb fibrolipoma showed feeding artery. One displayed radial-ulnar artery artificial fistula stenosis. One revealed left antebrachium hemangioma. Conclusion: TRICKS can clearly delineate most body vascular system and reveal most vascular abnormality. It possesses convenience and high successful rate, which make it the first choice of displaying most vascular abnormality. 展开更多
关键词 magnetic resonance angiography contrast-enhanced MR angiography time-resolved imaging of contrast kinetics (TRICKS) vascular malformation
下载PDF
Pulmonary Sequestration: Three Dimensional Dynamic Contrast-enhanced MR Angiography and MRI 被引量:2
16
作者 徐海波 姜冬玲 +4 位作者 孔祥泉 熊茵 刘定西 柳曦 邓先波 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2001年第4期345-348,共4页
In order to evaluate the diagnostic value of three dimentional contrast enhanced MR angiography and MRI for pulmonary sequestration, 5 patients with pulmonary sequestration underwent 3D fast imaging by steady state ... In order to evaluate the diagnostic value of three dimentional contrast enhanced MR angiography and MRI for pulmonary sequestration, 5 patients with pulmonary sequestration underwent 3D fast imaging by steady state precession (FISP) with a contrast medium and breath holding following chest radiography, CT and MR scans. The reconstructed MR angiography was performed using maximum intensity projection (MIP) and multiplanar reconstruction (MPR) techniques. It was found that the chest radiography showed pulmonary sequestration as a persistent area of opacity in the posterior basal segment of the left lower lobe, which was close to mediastinum in 2 cases and close to diaphragma in 3 cases. CT revealed a soft issue mass beyond descending aorta and lobar emphysema around the pulmonary sequestration. And the supplying vessel was documented in 2 cases on enhanced CT. MRI demonstrated a hyperintensity mass with respect to normal lung parenchyma on T1WI and T2WI, and the origin of the supplying vessel in 3 cases. The reconstructed CE MRA using MIP or MRP techniques clearly showed the supplying vessel and its course, branches as well as draining vessels. It was concluded that 3D CE MRA of demonstrating the supplying and draining vessels to pulmonary sequestration, together with plain MRI, can provide a diagnosis and aid in surgical planning without the need for DSA. 展开更多
关键词 pulmonary sequestration magnetic resonance angiography contrast medium magnetic resonance imaging
下载PDF
Oleic Acid (OA), A Potential Dual Contrast Agent for Postmortem MR Angiography (PMMRA): A Pilot Study 被引量:3
17
作者 Zhi-yuan XIA Christine BRUGUIER +3 位作者 Fabrice DEDOUIT Silke GRABHERR Marc AUGSBURGER Bei-bei LIU 《Current Medical Science》 SCIE CAS 2020年第4期786-794,共9页
Summary:Choosing proper perfusates as contrast agents is an important aspect for postmortem magnetic resonance angiography(PMMRA).However,in this emerging field,the number of suitable kinds of liquid is still very lim... Summary:Choosing proper perfusates as contrast agents is an important aspect for postmortem magnetic resonance angiography(PMMRA).However,in this emerging field,the number of suitable kinds of liquid is still very limited.The objective of this research is to compare MR images of oleic acid(OA)with paraffin oil(PO)in vitro and in ex situ animal hearts,in order to evaluate the feasibility to use OA as a novel contrast agent for PMMRA.In vitro,OA,PO and water(control)were introduced into three tubes separately and T,weighted-spin echo(Tw SE)and T2w-SE images were acquired on a 1.5T MR scanner.In the second experiment,0A and PO were injected into left coronary artery(LCA)and left ventricle(LV)of ex situ bovine hearts and their Tw-SE,Tzw-SE,Tw-multipoint Dixon(Tjw-mDixon)and 3DT2w-mDixon images were acquired.The overall results indicate that OA may have a potential to be used as a dual(T and T2 based)contrast agent for PMMRA when proper sequence parameters are utilized.However,as the pilot study was based on limited number of animal hearts,more researches using OA in cadavers are needed to validate our findings. 展开更多
关键词 postmortem magnetic resonance angiography perfusate contrast agent oleic acid paraffin oil HEART
下载PDF
Temporal dynamics of neonatal hypoxic-ischemic encephalopathy injuries on magnetic resonance imaging
18
作者 Holly Flyger Samantha J.Holdsworth +2 位作者 Alistair J.Gunn Laura Bennet Hamid Abbasi 《Neural Regeneration Research》 SCIE CAS 2025年第11期3144-3150,共7页
Moderate to severe perinatal hypoxic-ischemic encephalopathy occurs in~1 to 3/1000 live births in high-income countries and is associated with a significant risk of death or neurodevelopmental disability.Detailed asse... Moderate to severe perinatal hypoxic-ischemic encephalopathy occurs in~1 to 3/1000 live births in high-income countries and is associated with a significant risk of death or neurodevelopmental disability.Detailed assessment is important to help identify highrisk infants,to help families,and to support appropriate interventions.A wide range of monitoring tools is available to assess changes over time,including urine and blood biomarkers,neurological examination,and electroencephalography.At present,magnetic resonance imaging is unique as although it is expensive and not suited to monitoring the early evolution of hypoxic-ischemic encephalopathy by a week of life it can provide direct insight into the anatomical changes in the brain after hypoxic-ischemic encephalopathy and so offers strong prognostic information on the long-term outcome after hypoxic-ischemic encephalopathy.This review investigated the temporal dynamics of neonatal hypoxic-ischemic encephalopathy injuries,with a particular emphasis on exploring the correlation between the prognostic implications of magnetic resonance imaging scans in the first week of life and their relationship to long-term outcome prediction,particularly for infants treated with therapeutic hypothermia.A comprehensive literature search,from 2016 to 2024,identified 20 pertinent articles.This review highlights that while the optimal timing of magnetic resonance imaging scans is not clear,overall,it suggests that magnetic resonance imaging within the first week of life provides strong prognostic accuracy.Many challenges limit the timing consistency,particularly the need for intensive care and clinical monitoring.Conversely,although most reports examined the prognostic value of scans taken between 4 and 10 days after birth,there is evidence from small numbers of cases that,at times,brain injury may continue to evolve for weeks after birth.This suggests that in the future it will be important to explore a wider range of times after hypoxic-ischemic encephalopathy to fully understand the optimal timing for predicting long-term outcomes. 展开更多
关键词 magnetic resonance imaging neonatal hypoxic-ischemic encephalopathy neurodevelopmental outcomes prognostic biomarkers in neuroimaging scan timing therapeutic hypothermia
下载PDF
Advancement in utilization of magnetic resonance imaging and biomarkers in the understanding of schizophrenia
19
作者 Aidan K Tirpack Danyaal G Buttar Mandeep Kaur 《World Journal of Clinical Cases》 SCIE 2025年第1期11-15,共5页
Historically,psychiatric diagnoses have been made based on patient’s reported symptoms applying the criteria from diagnostic and statistical manual of mental disorders.The utilization of neuroimaging or biomarkers to... Historically,psychiatric diagnoses have been made based on patient’s reported symptoms applying the criteria from diagnostic and statistical manual of mental disorders.The utilization of neuroimaging or biomarkers to make the diagnosis and manage psychiatric disorders remains a distant goal.There have been several studies that examine brain imaging in psychiatric disorders,but more work is needed to elucidate the complexities of the human brain.In this editorial,we examine two articles by Xu et al and Stoyanov et al,that show developments in the direction of using neuroimaging to examine the brains of people with schizo-phrenia and depression.Xu et al used magnetic resonance imaging to examine the brain structure of patients with schizophrenia,in addition to examining neurotransmitter levels as biomarkers.Stoyanov et al used functional magnetic resonance imaging to look at modulation of different neural circuits by diagnostic-specific scales in patients with schizophrenia and depression.These two studies provide crucial evidence in advancing our understanding of the brain in prevalent psychiatric disorders. 展开更多
关键词 SCHIZOPHRENIA magnetic resonance imaging Biomarkers NEUROTRANSMITTERS Psychiatric disorders
下载PDF
Magnetic resonance imaging evaluation and nuclear receptor binding SET domain protein 1 mutation in the Sotos syndrome with attention-deficit/hyperactivity disorder
20
作者 Wei Zhu 《World Journal of Clinical Cases》 SCIE 2025年第2期5-9,共5页
Sotos syndrome is characterized by overgrowth features and is caused by alterations in the nuclear receptor binding SET domain protein 1 gene.Attentiondeficit/hyperactivity disorder(ADHD)is considered a neurodevelopme... Sotos syndrome is characterized by overgrowth features and is caused by alterations in the nuclear receptor binding SET domain protein 1 gene.Attentiondeficit/hyperactivity disorder(ADHD)is considered a neurodevelopment and psychiatric disorder in childhood.Genetic characteristics and clinical presentation could play an important role in the diagnosis of Sotos syndrome and ADHD.Magnetic resonance imaging(MRI)has been used to assess medical images in Sotos syndrome and ADHD.The images process is considered to display in MRI while wavelet fusion has been used to integrate distinct images for achieving more complete information in single image in this editorial.In the future,genetic mechanisms and artificial intelligence related to medical images could be used in the clinical diagnosis of Sotos syndrome and ADHD. 展开更多
关键词 Sotos syndrome Attention-deficit/hyperactivity disorder Genetic mutation magnetic resonance imaging Wavelet fusion
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部