期刊文献+
共找到432篇文章
< 1 2 22 >
每页显示 20 50 100
Role of Retinal Nerve Fiber Layer Thickness and Optic Disk Measurement by OCT onEarly Diagnosis of Glaucoma 被引量:3
1
作者 Zanmei Hua Qiuyun Fang +2 位作者 Xiangyin Sha Ruiming Yang Zuopeng Hong 《Eye Science》 CAS 2015年第1期7-12,共6页
Purpose:.Glaucoma is an eye disease that can lead to irreversible optic nerve damage and cause blindness. Optical coherence tomography.(OCT) allows an early diagnosis of glaucoma by the measurements of the retinal ner... Purpose:.Glaucoma is an eye disease that can lead to irreversible optic nerve damage and cause blindness. Optical coherence tomography.(OCT) allows an early diagnosis of glaucoma by the measurements of the retinal nerve fiber and optic disc parameters.A retrospective study was designed to analyze the effects of the measurement of the retinal nerve fiber layer(RNFL) thickness and the optic disc tomography by spectraldomain OCT on the early diagnosis of suspected glaucoma and primary open angle glaucoma(POAG).Methods:.This was a clinical case-control study. The RNFL thickness around the optic disc and optic disk tomographic parameters of the control(n=51, 98 eyes), suspected glaucoma(n=81,.146 eyes), and POAG groups(n=55, 106 eyes) were measured by OCT. The parameters included superior, inferior, nasal and temporal mean RNFL thickness,.disc area(DA), cup area(CA), rim area(RA), disc volume(DV),cup volume(CV), rim volume(RV), cup / disc area ratio(CA / DA), rim / disc area ratio(RA / DA), cup / disc volume ratio(CV / DV) and rim / disc volume ratio(RV / DV).Results: Superior, nasal, and mean RNFL parameters, DA,CA,RA, DV, CV, CA / DA, RA / DA, CV / DV and RV / DV significantly differed among three groups by single-factorial ANOVA. Inferior and temporal RNFL thickness significantly differed between the control and POAG groups. No significant difference was observed in RV among three groups. In the POAG group,.the maximum area under the ROC curve(AROC) of mean RNFL thickness was 0.845. The maximum AROC of optic disk parameters was RA / DA(0.998), followed by CA / DA(0.997). The AROC of CA, RA, CV, and DV were all > 0.900.Conclusion:.OCT may serve as a useful diagnostic modality in distinguishing suspected glaucoma from POAG. 展开更多
关键词 视神经损伤 厚度控制 早期诊断 青光眼 视网膜 纤维层 华侨城 视盘
下载PDF
Magneto-optical Disk Material for Improving the Density of Information Storage
2
作者 夏红霞 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2001年第2期54-57,共4页
This paper introduces the fundamental principle and features ofmagneto-optical storage technol- ogy, and discuses the trend and aseries of key techniques for increasing the data storage density ofmagneto-opti- cal dis... This paper introduces the fundamental principle and features ofmagneto-optical storage technol- ogy, and discuses the trend and aseries of key techniques for increasing the data storage density ofmagneto-opti- cal disk. The three ways including MO media, recordingmethod and readout method for increasing the disk ca- pacity havebeen discussed. Moreover, the importance with the exchange-coupledeffect between the magnetic layers and recording domain morphology isemphasized. 展开更多
关键词 magneto-optical disk information storage recording density
下载PDF
Detection of Influenza Viruses Attached to an Optical Disk
3
作者 Takayuki Shima Makoto Fujimaki +4 位作者 Akihiro Yoshida Subash C. B. Gopinath Masashi Kuwahara Yoshimichi Ohki Koichi Awazu 《Journal of Biomaterials and Nanobiotechnology》 2013年第2期145-150,共6页
Detection of polystyrene beads with a diameter of 100 nm was conducted using an optical disk drive tester equipped with a laser of 405 nm wavelength and an objective lens with a numerical aperture of 0.65. The polysty... Detection of polystyrene beads with a diameter of 100 nm was conducted using an optical disk drive tester equipped with a laser of 405 nm wavelength and an objective lens with a numerical aperture of 0.65. The polystyrene beads were used to mimic the influenza virus. A grooved disk with a (ZnS)85(SiO2)15/SiO2 layered surface structure was used for the detection. The detection of influenza viruses (A/Udorn/307/1972) with Au nanoparticles was also demonstrated using the optical disk drive tester. In this case, a grooved disk with an indium tin oxide (ITO) film was used. The ITO film functioned both to tune the reflectance of the disk and as an electrically conductive layer for scanning electron microscopy. In both cases, the target substances were successfully recognized in a single scan with a high scanning speed of 4.9 m/s. The results indicate that this optical disk system can be used to detect 100 nm scale substances like influenza viruses, which are smaller than the diffraction limit of the system. 展开更多
关键词 INFLUENZA VIRUS POLYSTYRENE BEAD optical disk Laser Reflectance Sensor Safety and Security
下载PDF
Study on Stereometric Parameters of Optic Nerve Head of Normal, Big-cupped Disk and Glaucomatous Eyes Using Heidelberg Retina Tomograph
4
作者 Xing liu, Yunlan Ling, Xiaoping Zheng, Jingjing HuangZhongshan Ophthalmic Center, Sun Yat-sen University of Medical Sciences, Guangzhou 510060, China 《眼科学报》 2000年第3期163-167,共5页
Purpose: To investigate the difference of stereometric parameters of optic nerve head between the normal subjects and patients with big-cupped disk and primary open angle glaucoma (POAG).Methods: Twenty-two cases (44 ... Purpose: To investigate the difference of stereometric parameters of optic nerve head between the normal subjects and patients with big-cupped disk and primary open angle glaucoma (POAG).Methods: Twenty-two cases (44 eyes) of normal subjects, 17 cases (34 eyes) of patients with big-cupped disk and 19 cases (37 eyes) of patients with POAG underwent Heidelberg Retina Tomograph (HRT) examination to get topography images and stereometric parameters of optic nerve head.Results: The stereometric parameters of optic nerve head of the normal, patients with big-cupped disk and POAG were 1) disk area (mm2): 1. 995± 0. 501, 2. 407±0. 661 and 2. 248±0.498; 2) cup area (mm2): 0.573±0.264, 1. 095±0. 673 and 1. 340±0. 516; 3) cup/disk ratio: 0. 25±0. 095, 0. 428±0. 176 and 0. 589±0.195; 4) rim area (mm2): 1.461±0.328, 1.312±0.418 and 0. 905± 0.409; 5)cup volume (mm3): 0. 108±0. 073, 0. 347±0. 346 and 0. 550 ±0. 394; 6) rim volume (mm3): 0. 421±0. 111, 0. 378±0. 225 and 0. 224±0. 189; 7) mean cup 展开更多
关键词 青光眼 视网膜图 视乳头杯 视神经乳头
下载PDF
Optical coherence tomography in optic disc drusen
5
作者 J.Alexander Fraser Lulu L.C.D.Bursztyn 《Annals of Eye Science》 2020年第1期22-34,共13页
Optic disc drusen (ODD) are hyaline deposits in the optic nerve head, occurring in approximately 2% of the population. ODD may be superficial and visible, or buried and either invisible or seen only as elevation of th... Optic disc drusen (ODD) are hyaline deposits in the optic nerve head, occurring in approximately 2% of the population. ODD may be superficial and visible, or buried and either invisible or seen only as elevation of the optic disc, mimicking optic disc edema. Advanced optic nerve imaging, including optical coherence tomography (OCT) can be used to diagnose and characterize ODD with very high resolution. Enhanced depth imaging (EDI-OCT) in particular has emerged as the optimal modality to directly visualize ODD. This modality has led to a greater ability to differentiate ODD from optic disc edema and prevent misdiagnosis or invasive testing. We review the characteristic findings of ODD on OCT, their distinguishing features, and the use of OCT as a biomarker in the neuro-ophthalmic assessment of ODD. 展开更多
关键词 DRUSEN optic disk TOMOGRAPHY optical coherence
下载PDF
EFFECTS OF SPUTTERING CONDITIONS OF Tb Fe Co MAGNETO OPTICAL FILM ON KERRR OTATION
6
作者 X.Y.Zhang , Z.N.Liu , J.Yi and Z.W.Chen Dept.of Materials Eng.,Southwest Jiaotong University,Chengdu 610031 ,China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1999年第4期630-632,共3页
In the practical magneto opticaldisk productionline,alloysputteringtargetisalwaysusedtosputter recording film , whileinlaid targetisrarely used .In ourlaboratory,a seriesof al loy targets forsputtering magneto- opti... In the practical magneto opticaldisk productionline,alloysputteringtargetisalwaysusedtosputter recording film , whileinlaid targetisrarely used .In ourlaboratory,a seriesof al loy targets forsputtering magneto- optical recording film were prepared and theeffect ofcomposition andsputtering parameterson magneto opticalpropertiesarestudied . Thesputter ing rateof Al,Siand Tb Fe Co( Mo) undertheconditionsof differentsputtering powerandN2 Argasflux weredetermined and baseontheresults,a variablecomposition andthickness of SiNcan beobtained by meansof regulating sputtering power and gasflux, kindsof Mosputtering filmsareobtained under differentsputtering power and gasflux, and Kerrloop lineofthese magneto opticalfilmsare measuredto acquiretheir propertiessuch as Kerrrota tion,then ,theeffectofsputteringtechnology on Kerrrotationisdiscussed . 展开更多
关键词 MAGNETO optical disk FILM MAGNETO optical material
下载PDF
Structure and Magneto-Optical Characteristic Study of Optical Multilayer Thin Films
7
作者 YANGCheng-tao 《Journal of Electronic Science and Technology of China》 2005年第1期94-95,共2页
关键词 multiplayer soft x-ray REFLECTIVITY SUPERLATTICE magneto-optical disk
下载PDF
基于ReSE-AG-Net的青光眼视盘视杯分割方法
8
作者 李豪杰 郭子洋 +2 位作者 刘伟志 罗益 曹秒 《长春理工大学学报(自然科学版)》 2024年第4期115-121,共7页
分割视盘视杯是诊断青光眼的主要依据,因此提出了一种基于改进U-Net网络的青光眼视盘视杯分割方法,称为ReSE-AG-Net。并将ReSE-AG-Net、U-Net、M-Net、CE-Net和CDED-Net分别在Drishti-GS1数据集和RIM-ONE-R3数据集上进行测试,对得到分... 分割视盘视杯是诊断青光眼的主要依据,因此提出了一种基于改进U-Net网络的青光眼视盘视杯分割方法,称为ReSE-AG-Net。并将ReSE-AG-Net、U-Net、M-Net、CE-Net和CDED-Net分别在Drishti-GS1数据集和RIM-ONE-R3数据集上进行测试,对得到分割后的视盘视杯的Dice系数和IoU进行对比。实验结果表明,在Drishti-GS1数据集上,分割视盘的Dice系数和IoU分别是0.989 1和0.959 0,分割视杯的Dice系数和IoU分别是0.931 0和0.871 0,在RIMONE-R3数据集上,分割视盘的Dice系数和IoU分别是0.978 9和0.958 7,分割视杯的Dice系数和IoU分别是0.863 7和0.760 1,对比U-Net模型和现有的分割模型均有一定的提升,证明了该方法的可行性。 展开更多
关键词 青光眼 视盘视杯分割 U-Net ReSE-AG-Net
下载PDF
近视病人青光眼诊断的研究进展
9
作者 卫水娟 杨继红 《安徽医药》 CAS 2024年第10期1912-1917,共6页
近视是青光眼发病的高危因素,且研究表明近视程度越高,患青光眼的可能性就越大。近视病人青光眼诊断是一个特殊问题,这可能因为早期青光眼与近视的表现相似,所以许多近视病人因青光眼而使视力受到损害,但未引起临床医生考虑青光眼的可... 近视是青光眼发病的高危因素,且研究表明近视程度越高,患青光眼的可能性就越大。近视病人青光眼诊断是一个特殊问题,这可能因为早期青光眼与近视的表现相似,所以许多近视病人因青光眼而使视力受到损害,但未引起临床医生考虑青光眼的可能性。近年来随着眼科影像技术的发展,尤其是光学相干断层扫描与共焦激光眼底扫描红外成像及无赤光眼底照相技术的结合、光学相干断层扫描离散傅里叶变换分析与视野的结合,光学相干断层扫描血流成像的快速革新,临床医生可以从多方面了解近视与青光眼的发生发展,为早期诊断近视眼青光眼,及时干预治疗,从而为提高近视病人的视觉生活质量提供坚实的基础。 展开更多
关键词 近视 青光眼 诊断 光学相干断层扫描 视盘
下载PDF
基于CD/DVD光盘的光波衍射研究
10
作者 侯其哲 谢植鑫 +4 位作者 叶志杰 陈鑫伟 巢家乐 曾逼立 邹少辉 《韶关学院学报》 2024年第3期40-46,共7页
白炽灯光入射在CD/DVD光盘会呈现随着角度轻微变化发生相应变化的彩色线.基于CD/DVD光盘的制造工艺,利用MATLAB软件对衍射规律进行理论分析,使用分光计实验观察白炽灯照射下CD/DVD光盘呈现出彩色线的衍射现象,验证不同入射角、衍射角、... 白炽灯光入射在CD/DVD光盘会呈现随着角度轻微变化发生相应变化的彩色线.基于CD/DVD光盘的制造工艺,利用MATLAB软件对衍射规律进行理论分析,使用分光计实验观察白炽灯照射下CD/DVD光盘呈现出彩色线的衍射现象,验证不同入射角、衍射角、水平偏转角与波长的关系,获得不同条件下的衍射图案.为光学和材料科学等多个学科领域以及数字储存技术的发展提供新的思路和方向. 展开更多
关键词 光盘 分光计 光栅常数 衍射图案
下载PDF
关于光盘上出现彩色线的实验研究
11
作者 潘国柱 赵宗耀 +1 位作者 赵子言 吴克跃 《皖西学院学报》 2024年第2期110-114,共5页
为了探究光盘(CD或DVD)的光栅衍射规律,以2023年全国大学生物理学术竞赛“色彩线”这一题为例,从理论与实验两方面研究光盘在有无刻录、不同的刻录方式、不同的光路入射角度等条件下衍射条纹颜色的变化情况,探究光盘上光栅衍射规律。结... 为了探究光盘(CD或DVD)的光栅衍射规律,以2023年全国大学生物理学术竞赛“色彩线”这一题为例,从理论与实验两方面研究光盘在有无刻录、不同的刻录方式、不同的光路入射角度等条件下衍射条纹颜色的变化情况,探究光盘上光栅衍射规律。结果表明:光盘上衍射条纹颜色与光盘结构、入射光角度和光盘倾角有关。该研究对新型光盘材料和技术的开发有着一定的理论和实践意义。 展开更多
关键词 光盘 彩色线 光栅衍射
下载PDF
聚碳酸酯光学性能应用及改进研究进展 被引量:24
12
作者 李复生 魏东炜 +2 位作者 崔金华 殷金柱 宋光复 《塑料》 CAS CSCD 2003年第3期65-69,共5页
概述了光学级聚碳酸酯结构与光学性能的关系和其在光学领域的应用,对其光学异向性产生的原因进行了讨论,并对改善聚碳酸酯光学异向性的途径进行了归纳,通过采用共聚、共混方法可使聚碳酸酯的双折射得到有效的降低。
关键词 聚碳酸酯 光学性能 应用 改进 研究进展 光盘盘基 双折射 共聚
下载PDF
微动脉瘤与出血自动检测的NPDR图像分型方法 被引量:7
13
作者 郑绍华 潘林 +2 位作者 陈健 郭健 余轮 《仪器仪表学报》 EI CAS CSCD 北大核心 2014年第1期59-67,共9页
为构建糖尿病视网膜病变(DR)自动筛查系统,依据新的糖尿病视网膜病变国际临床分型标准,提出了一种基于微动脉瘤(MAs)和视网膜内出血(HAs)自动检测的非增生性糖尿病视网膜病变(NPDR)图像分型方法。首先在红色通道上利用自适应阈值、形态... 为构建糖尿病视网膜病变(DR)自动筛查系统,依据新的糖尿病视网膜病变国际临床分型标准,提出了一种基于微动脉瘤(MAs)和视网膜内出血(HAs)自动检测的非增生性糖尿病视网膜病变(NPDR)图像分型方法。首先在红色通道上利用自适应阈值、形态学技术及区域主动轮廓模型对视盘中心进行精确定位;再者,在绿色通道预处理及现有算法改进的基础上,提出了一种新的基于Radon变换的方法对HAs和MAs进行识别,有效地抑制了血管或背景纹理的干扰,算法不依赖于血管的分割,也无需多尺度匹配滤波器。实验选取了120幅高分辨率的NPDR图像,对HAs和MAs的检测均得到较高的灵敏度和特异性,在各分型上准确率都达到了85%以上,不存在漏诊的情况。算法稳定,具有较高的实用价值。 展开更多
关键词 糖尿病视网膜病变 微动脉瘤 出血 视盘 RADON变换
下载PDF
眼底图像中黄斑中心与视盘自动检测新方法 被引量:9
14
作者 郑绍华 陈健 +2 位作者 潘林 郭健 余轮 《电子与信息学报》 EI CSCD 北大核心 2014年第11期2586-2592,共7页
在眼底图像自动分析中,视盘与黄斑的定位是糖尿病性视网膜病变计算机辅助诊断或筛查的先决条件。该文提出一种应用方向局部对比度滤波结合局部血管密度的方法,直接先行检测黄斑中心再行定位视盘,不同于现有的先行检测视盘或血管再行定... 在眼底图像自动分析中,视盘与黄斑的定位是糖尿病性视网膜病变计算机辅助诊断或筛查的先决条件。该文提出一种应用方向局部对比度滤波结合局部血管密度的方法,直接先行检测黄斑中心再行定位视盘,不同于现有的先行检测视盘或血管再行定位黄斑的一般方法,有效地提高黄斑定位正确率,能更好地应用于糖尿病性黄斑水肿的自动评估。实验选取了网络公开的HEI-MED数据集中169幅黄斑水肿眼底图像,黄斑和视盘的定位正确率同步达到98.2%,算法简单且无监督,优于现有的方法,具有良好的临床应用前景。 展开更多
关键词 模式识别 眼底图像 黄斑 视盘 方向局部对比度 血管分割
下载PDF
彩色眼底图像视盘自动定位与分割 被引量:24
15
作者 邹北骥 张思剑 朱承璋 《光学精密工程》 EI CAS CSCD 北大核心 2015年第4期1187-1195,共9页
针对彩色眼底图像视盘定位时图像边缘高亮环对定位准确率的影响,提出了一种有效的图像预处理方法。针对已有的视盘分割算法中存在的问题,提出了一种结合形态学、椭圆拟合及梯度矢量流(GVF)Snake模型的分割算法。提出的预处理方法首先利... 针对彩色眼底图像视盘定位时图像边缘高亮环对定位准确率的影响,提出了一种有效的图像预处理方法。针对已有的视盘分割算法中存在的问题,提出了一种结合形态学、椭圆拟合及梯度矢量流(GVF)Snake模型的分割算法。提出的预处理方法首先利用最小二乘法拟合出眼底图像的边界,然后裁剪掉边界的一部分高亮像素点,最后进行视盘定位。视盘分割算法则首先进行血管擦除,然后用椭圆拟合提取初始轮廓,最后使用GVF Snake精确调整视盘边界。用提出的方法对Messidor眼底图像数据库1 200幅图像上进行了实验,结果显示:视盘定位准确率由原来没经过预处理的95.4%提升到了98.7%;视盘分割错误率与当前已知最好的算法相比由12.5%降低到了9.39%。结果表明:提出的眼底图像视盘自动定位与分割方法准确率高、实用性强,可以用于眼科疾病的计算机辅助诊断。 展开更多
关键词 彩色眼底图像 图像预处理 视盘定位 视盘分割
下载PDF
有机光致变色存储材料进展 被引量:29
16
作者 李瑛 谢明贵 《功能材料》 EI CAS CSCD 北大核心 1998年第2期113-120,共8页
本文综述了最近二十年来在有机光致变色存储材料方面的进展。
关键词 光盘 有机 光存储材料 光致变色化合物
下载PDF
光盘信息符散斑图的统计特性研究 被引量:5
17
作者 李新忠 岱钦 +1 位作者 汪永阳 王希军 《光子学报》 EI CAS CSCD 北大核心 2006年第11期1705-1708,共4页
提出了一种用激光散斑测量光盘信息符统计特性的方法.利用散斑统计理论中衍射散斑场的平均对比度与散射屏表面粗糙度近似成线性关系,把光盘等效为弱散射屏,对未刻录、刻录及存在缺陷的CD-R光盘不同区域形成的衍射散斑图进行了对比研究.... 提出了一种用激光散斑测量光盘信息符统计特性的方法.利用散斑统计理论中衍射散斑场的平均对比度与散射屏表面粗糙度近似成线性关系,把光盘等效为弱散射屏,对未刻录、刻录及存在缺陷的CD-R光盘不同区域形成的衍射散斑图进行了对比研究.实验结果表明,该方法具有可量化、全场测量的优点,能够表征光盘信息符的某些统计特性,这为测量光盘刻录质量提供了一种新的方法和途径. 展开更多
关键词 激光散斑 光盘 信息符 统计特性
下载PDF
FD—OCT对原发性急性闭角型青光眼视网膜厚度和体积的测量 被引量:8
18
作者 欧文 王泽飞 +1 位作者 方爱武 郑钦象 《中华实验眼科杂志》 CAS CSCD 北大核心 2014年第2期154-158,共5页
背景原发性急性闭角型青光眼(PAACG)大发作后可引起不同程度的视功能损害,了解PAACG发作眼视盘及黄斑区视网膜的结构改变对于判断患眼的预后具有重要的临床意义。傅里叶域OCT(FD-OCT)是测量视网膜结构的有用工具。目的采用FD—OCT... 背景原发性急性闭角型青光眼(PAACG)大发作后可引起不同程度的视功能损害,了解PAACG发作眼视盘及黄斑区视网膜的结构改变对于判断患眼的预后具有重要的临床意义。傅里叶域OCT(FD-OCT)是测量视网膜结构的有用工具。目的采用FD—OCT对PAACG大发作后视盘区视网膜神经纤维层厚度(RNFLT)、黄斑区厚度以及黄斑区体积的变化进行测量,并与正常眼进行比较。方法采用病例对照临床试验方法。收集2011年4月至2012年2月在温州医学院眼视光医院确诊为PAACG且有一侧眼大发作的患者25例,并纳入同期年龄和性别相匹配的正常志愿者25人25眼为正常对照眼,于PAACG患眼大发作后2周由同一位操作熟练的检查者采用FD—OCT测量患者发作眼、对侧眼和正常对照眼RNFLT、黄斑区厚度及黄斑区体积。结果PAACG发作后2周内发作眼组视盘区平均RNFLT值为(125.72±28.57)μm,明显高于对侧眼组的(108.36±9.31)μm和正常对照眼组的(106.10±10.97)μm,差异均有统计学意义(P〈0.05);此外,发作眼组视盘上方、下方、鼻侧象限RNFLT值均明显高于对侧眼组和正常对照眼组,差异均有统计学意义(P〈0.05),而视盘颞侧象限和颞下象限RNFLT值的差异均无统计学意义(P=0.081、0.766)。发作眼组、对侧眼组和正常对照眼组黄斑区视网膜平均厚度分别(283.72±18.33)、(280.28±16.85)和(289.14±10.60)“m,3个组间黄斑区各象限视网膜厚度值差异无统计学意义(FH镕=2.048,P=0.136),其中对侧眼组视网膜厚度值均明显低于正常对照眼组(P〈0.05),发作眼组与正常对照眼组间差异无统计学意义(P=0.224)。发作眼组、对侧眼组和正常对照眼组黄斑区总体积分别为(5.589±O.355)、(5.532±0.325)和(5.720±0.241)mm。,黄斑区各象限体积比较差异无统计学意义(F*。=1.027,P=0.363)。各组外环各象限厚度值均明显小于内环厚度值,内环及外环黄斑区视网膜厚度值均呈鼻侧〉上方〉下方〉颞侧的趋势。PAACG患者发作眼和对侧眼在视盘内环颞侧、上方、鼻侧、下方和外环颞侧、中央区黄斑区厚度值及其体积值均明显低于正常对照眼,差异均有统计学意义(P〈0.05)。结论PAACG发作眼发作2周内视盘区RNFL水肿比黄斑区更明显,发作眼和对侧眼的黄斑区视网膜均比正常对照眼变薄,其黄斑区体积均小于正常对照眼。 展开更多
关键词 体层摄影术 光学相干 方法 青光眼 闭角型 原发性 急性疾病 视神经纤维层 病理 视盘 病理 黄斑 视网膜
下载PDF
高密度可录光盘存储材料:金属卟啉配合物 被引量:6
19
作者 陈志敏 左霞 吴谊群 《化学进展》 SCIE CAS CSCD 2004年第5期820-828,共9页
金属卟啉配合物在 4 0 0— 6 5 0nm波段具有优良的光学性质 ,是一类新型高密度可录光盘存储介质材料。本文在总结近年来最新研究成果的基础上 ,阐述了金属卟啉配合物的结构特点、合成方法和作为高密度可录光盘存储介质的作用机理 ,讨论... 金属卟啉配合物在 4 0 0— 6 5 0nm波段具有优良的光学性质 ,是一类新型高密度可录光盘存储介质材料。本文在总结近年来最新研究成果的基础上 ,阐述了金属卟啉配合物的结构特点、合成方法和作为高密度可录光盘存储介质的作用机理 ,讨论了影响卟啉配合物性质和光存储性能的主要因素 。 展开更多
关键词 高密度可录光盘存储材料 金属卟啉配合物 结构 合成 作用机理
下载PDF
酞菁光盘染料的研究进展 被引量:17
20
作者 彭必先 高德涛 闫天堂 《中国科学院研究生院学报》 CAS CSCD 2000年第1期43-56,共14页
总结了酞菁光盘染料近十几年的合成进展 ,以及其基本类型、结构与光物理性质之间的关系 ,并在应用方面总结了酞菁光盘染料结构与应用性能之间的关系 ,对其在CD R的应用前景方面作了简要分析 .
关键词 酞菁光盘染料 CD-R酞菁染料 光盘记录介质 存储介质 结构 光物理性质 卟啉衍生物
下载PDF
上一页 1 2 22 下一页 到第
使用帮助 返回顶部