期刊文献+
共找到32篇文章
< 1 2 >
每页显示 20 50 100
Improving the performance of conventional base isolation systems by an external variable negative stiffness device under near-fault and long-period ground motions 被引量:8
1
作者 Sandhya Nepal Masato Saitoh 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第4期985-1003,共19页
Recent studies have shown that base-isolated objects with long fundamental natural periods are highly influenced by long-period earthquakes. These long-period waves result in large displacements for isolators, possibl... Recent studies have shown that base-isolated objects with long fundamental natural periods are highly influenced by long-period earthquakes. These long-period waves result in large displacements for isolators, possibly leading to exceedance of the allowable displacement limits. Conventional isolation systems, in general, fail to resist such large displacements. This has prompted the need to modify conventional base isolation systems. The current work focuses on the development of an external device, comprising a unit of negative and positive springs, for improving the performance of conventional base isolation systems. This unit accelerates the change in the stiffness of the isolation system where the stiffness of the positive spring varies linearly in terms of the displacement response of the isolated objects. The target objects of the present study are small structures such as computer servers, sensitive instruments and machinery. Numerical studies show that the increase in the damping of the system and the slope of the linear function is effective in reducing the displacement response. An optimal range of damping values and slope, satisfying the stability condition and the allowable limits of both displacement and acceleration responses when the system is subjected to near-fault and long-period ground motions simultaneously, is proposed. 展开更多
关键词 base isolation near-fault earthquakes long-period earthquakes negative stiffness variable stiffness
下载PDF
Mechanical property of U-Shaped 65Mn steel bumpers for seismic base isolation 被引量:3
2
作者 Han Miao Wang Yuandong +1 位作者 Du Hongkai Cui Xiangdong 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第3期791-802,共12页
This study proposes a novel U-shaped 65Mn steel bumper as the displacement restraining device for base-isolated structures with laminated elastomeric rubber bearings.A series of bumpers with different geometric parame... This study proposes a novel U-shaped 65Mn steel bumper as the displacement restraining device for base-isolated structures with laminated elastomeric rubber bearings.A series of bumpers with different geometric parameters were designed and tested under monotonic and cyclic quasi-static loading protocols.The experimental results from a total of 232 specimens were analyzed to develop an analytical model to calculate the backbone curve and the maximum elastic restoring force for U-shaped 65Mn bumpers.Thus,the analytical equations to calculate the elastic,hardening,and unloading stiffness of U-shaped 65Mn bumpers,as well as their maximum elastic restoring force,are validated by using an additional ten groups of bumpers with varying radiuses.These analytical equations can accurately predict the mechanical parameters of U-shaped 65Mn steel bumpers for a design purpose. 展开更多
关键词 U-shaped bumper base isolation EXPERIMENTAL mechanical properties analytical model
下载PDF
Probabilistic analysis for the response of nonlinear base isolation system under the ground excitation induced by high dam flood discharge 被引量:2
3
作者 Liang Chao Zhang Jinliang +2 位作者 Lian Jijian Liu Fang Li Xinyao 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第4期841-857,共17页
According to theoretical analysis, a general characteristic of the ground vibration induced by high dam flood discharge is that the dominant frequency ranges over several narrow frequency bands, which is verified by o... According to theoretical analysis, a general characteristic of the ground vibration induced by high dam flood discharge is that the dominant frequency ranges over several narrow frequency bands, which is verified by observations from the Xiangjiaba Hydropower Station. Nonlinear base isolation is used to reduce the structure vibration under ground excitation and the advantage of the isolation application is that the low-frequency resonance problem does not need to be considered due to its excitation characteristics, which significantly facilitate the isolation design. In order to obtain the response probabilistic distribution of a nonlinear system, the state space split technique is modified. As only a few degrees of freedom are subjected to the random noise, the probabilistic distribution of the response without involving stochastic excitation is represented by the δ function. Then, the sampling property of the δ function is employed to reduce the dimension of the Fokker-Planck-Kolmogorov (FPK) equation and the low-dimensional FPK equation is solvable with existing methods. Numerical results indicate that the proposed approach is effective and accurate. Moreover, the response probabilistic distributions are more reasonable and scientific than the peak responses calculated by conventional time and frequency domain methods. 展开更多
关键词 ground vibration high dam flood discharge structural response nonlinear base isolation system probabilisticanalysis
下载PDF
Research and development of seismic base isolation technique for civil engineering structures 被引量:1
4
作者 Zhu Hongping Mei Shilong +2 位作者 Li Li Ye Kun Yuan Yong 《Engineering Sciences》 EI 2010年第1期16-21,共6页
Base isolation is one of the most promising alternatives among the structure control methods. In recent decades, base isolation has been seriously considered for civil structures, such as buildings and bridges, subjec... Base isolation is one of the most promising alternatives among the structure control methods. In recent decades, base isolation has been seriously considered for civil structures, such as buildings and bridges, subjected to ground motion. The research achievements and development of seismic base isolation technique for civil structures in Huazhong University of Science and Technology (HUST) are introduced. The achievements include project applications, experimental research results and theoretical innovation. 展开更多
关键词 seismic base isolation civil structures DEVELOPMENT APPLICATION
下载PDF
Base Isolation Seismic Retrofit of a Hospital Building in Italy 被引量:1
5
作者 Massimiliano Ferraioli Alberto Maria Avossa 《Journal of Civil Engineering and Architecture》 2012年第3期308-321,共14页
The paper deals on a significant retrofit project currently under construction of an existing hospital building in Avellino (Italy). The seismic retrofit was realized by connecting together the first floors of the t... The paper deals on a significant retrofit project currently under construction of an existing hospital building in Avellino (Italy). The seismic retrofit was realized by connecting together the first floors of the three existing structures and by creating a unique isolation system composed of high damping rubber bearings and sliding devices. The base isolation is achieved by gradually cutting the building from foundation and installing the isolators at the level of upper edge of the columns. The study allows the verification of the adequacy of the isolation system, showing the benefits of the application of the isolation devices, the limitations and the characteristics of their performance. 展开更多
关键词 Seismic retrofit base isolation seismic response.
下载PDF
Research on Nonlinear Dynamic Characteristics ofStructures Supported on Slide-Limited Friction Base Isolation System
6
作者 Fan Jian Tang Jiaxiang Department of Civil Engineering , Huazhong University of Science and Technology , Wuhan 430074 《Journal of China University of Geosciences》 SCIE CSCD 2001年第4期301-308,共8页
This paper presents a new type of base isolation system, i. e. , slide-limited friction (S-LF) base isolation system . Based on this system, the harmonic and subharmonic periodic response of S-LF subjected to harmonic... This paper presents a new type of base isolation system, i. e. , slide-limited friction (S-LF) base isolation system . Based on this system, the harmonic and subharmonic periodic response of S-LF subjected to harmonic motions is investigated by using Fourier-Galerkin-Newton (FGN) method with Flo-quet theory. The dynamic response of S-LF subjected to earthquake ground motions is calculated with a high order precision direct integration method, and the numerical results are presented in maximum acceleration response spectra of superstructure and maximum sliding displacement response spectrum form. The comparison of isolating effects of S-LF, pure-friction base isolation system (P-F) and resilient-friction base isolation system (R-FBI) shows that the isolating property of S-LF is superior to those of P-F and R-FBI. Finally, by analyzing an engineering example, it is observed that the distribution of the maximum shear between floors and absolute acceleration of S-LF to earthquake ground motion is very different from that of traditional structures. 展开更多
关键词 base isolation FRICTION slide-limited device precision direct integration method FGN method.
下载PDF
Effects of Bearing Type on Seismic Response of Small Base Isolation System Using Friction Bearings
7
作者 Katsumi Kurita Mikito Kezuka +3 位作者 Shigeru Aoki Yuuj i Nakanishi Kazutoshi Tominaga Mitsuo Kanazawa 《Journal of Civil Engineering and Architecture》 2014年第3期261-267,共7页
In this study, dynamic characteristics of the small base isolation system using new friction bearings are investigated by excitation experiment, and compared to other one using previous bearings. Peak amplitude of the... In this study, dynamic characteristics of the small base isolation system using new friction bearings are investigated by excitation experiment, and compared to other one using previous bearings. Peak amplitude of the acceleration response waves on the small base isolation system is decreased to about 10%-25% compared to the input waves. Also root mean square amplitude is decreased to about 10%-40%. In case of the ball embedded a cylindrical sponge, the new bearing, the damping ratio increases with increasing width of the cylindrical sponge. The natural frequency does not change. On the other hand, in case of the marble plate that is previous bearing, the damping ratio increases with increasing curvature radius of the marble plate, the natural frequency also increases. Therefore, the small base isolation system using new friction bearing provides better performance. The responses of the base isolation system indicate nonlinier effects by friction force. 展开更多
关键词 Small base isolation system friction bearing peak amplitude natural frequency damping ratio.
下载PDF
Prediction of Damping Capacity Demand in Seismic Base Isolators via Machine Learning
8
作者 Ayla Ocak Umit Isıkdag +3 位作者 Gebrail Bekdas Sinan Melih Nigdeli Sanghun Kim ZongWoo Geem 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2899-2924,共26页
Base isolators used in buildings provide both a good acceleration reduction and structural vibration control structures.The base isolators may lose their damping capacity over time due to environmental or dynamic effe... Base isolators used in buildings provide both a good acceleration reduction and structural vibration control structures.The base isolators may lose their damping capacity over time due to environmental or dynamic effects.This deterioration of them requires the determination of the maintenance and repair needs and is important for the long-termisolator life.In this study,an artificial intelligence prediction model has been developed to determine the damage and maintenance-repair requirements of isolators as a result of environmental effects and dynamic factors over time.With the developed model,the required damping capacity of the isolator structure was estimated and compared with the previously placed isolator capacity,and the decrease in the damping property was tried to be determined.For this purpose,a data set was created by collecting the behavior of structures with single degrees of freedom(SDOF),different stiffness,damping ratio and natural period isolated from the foundation under far fault earthquakes.The data is divided into 5 different damping classes varying between 10%and 50%.Machine learning model was trained in damping classes with the data on the structure’s response to random seismic vibrations.As a result of the isolator behavior under randomly selected earthquakes,the recorded motion and structural acceleration of the structure against any seismic vibration were examined,and the decrease in the damping capacity was estimated on a class basis.The performance loss of the isolators,which are separated according to their damping properties,has been tried to be determined,and the reductions in the amounts to be taken into account have been determined by class.In the developed prediction model,using various supervised machine learning classification algorithms,the classification algorithm providing the highest precision for the model has been decided.When the results are examined,it has been determined that the damping of the isolator structure with the machine learning method is predicted successfully at a level exceeding 96%,and it is an effective method in deciding whether there is a decrease in the damping capacity. 展开更多
关键词 Vibration control base isolation machine learning damping capacity
下载PDF
Performance of sand and shredded rubber tire mixture as a natural base isolator for earthquake protection 被引量:11
9
作者 Srijit Bandyopadhyay Aniruddha Sengupta G.R.Reddy 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第4期683-693,共11页
The performance of a well-designed layer of sand, and composites like layer of sand mixed with shredded rubber tire (RSM) as low cost base isolators, is studied in shake table tests in the laboratory. The building fou... The performance of a well-designed layer of sand, and composites like layer of sand mixed with shredded rubber tire (RSM) as low cost base isolators, is studied in shake table tests in the laboratory. The building foundation is modeled by a 200 mm by 200 mm and 40 mm thick rigid plexi-glass block. The block is placed in the middle of a 1m by 1m tank filled with sand. The selected base isolator is placed between the block and the sand foundation. Accelerometers are placed on top of the footing and foundation sand layer. The displacement of the footing is also measured by LVDT. The whole setup is mounted on a shake table and subjected to sinusoidal motions with varying amplitude and frequency. Sand is found to be effective only at very high amplitude (> 0.65 g) of motions. The performance of a composite consisting of sand and 50% shredded rubber tire placed under the footing is found to be most promising as a low-cost effective base isolator. 展开更多
关键词 shake table test base isolation shredded rubber tire model test
下载PDF
Seismic response evaluation of base-isolated reinforced concrete buildings under bidirectional excitation 被引量:8
10
作者 Satish Bhagat Anil C Wijeyewickrema 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第2期365-382,共18页
This paper reports on an investigation of the seismic response of base-isolated reinforced concrete buildings, which considers various isolation system parameters under bidirectional near-fault and far-fault motions. ... This paper reports on an investigation of the seismic response of base-isolated reinforced concrete buildings, which considers various isolation system parameters under bidirectional near-fault and far-fault motions. Three-dimensional models of 4-, 8-, and 12-story base-isolated buildings with nonlinear effects in the isolation system and the superstructure are investigated, and nonlinear response history analysis is carried out. The bounding values of isolation system properties that incorporate the aging effect of isolators are also taken into account, as is the current state of practice in the design and analysis of base-isolated buildings. The response indicators of the buildings are studied for near-fault and far-fault motions weight-scaled to represent the design earthquake (DE) level and the risk-targeted maximum considered earthquake (MCER) level. Results of the nonlinear response history analyses indicate no structural damage under DE-level motions for near-fault and far-fault motions and for MCER-level far-fault motions, whereas minor structural damage is observed under MCER- level near-fault motions. Results of the base-isolated buildings are compared with their fixed-base counterparts. Significant reduction of the superstructure response of the 12-story base-isolated building compared to the fixed-base condition indicates that base isolation can be effectively used in taller buildings to enhance performance. Additionally, the applicability of a rigid superstructure to predict the isolator displacement demand is also investigated. It is found that the isolator displacements can be estimated accurately using a rigid body model for the superstructure for the buildings considered. 展开更多
关键词 Keywords: base isolation bidirectional excitation bounding analysis far-fault ground motion near-fault groundmotion nonlinear analysis
下载PDF
Performance-based semi-active control algorithm for protecting base isolated buildings from near-fault earthquakes 被引量:3
11
作者 Behnam Mehrparvar Taramarz Khoshnoudian 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2012年第1期43-55,共13页
Base isolated structures have been found to be at risk in near-fault regions as a result of long period pulses that may exist in near-source ground motions. Various control strategies, including passive, active and se... Base isolated structures have been found to be at risk in near-fault regions as a result of long period pulses that may exist in near-source ground motions. Various control strategies, including passive, active and semi-active control systems, have been investigated to overcome this problem. This study focuses on the development of a semi-active control algorithm based on several performance levels anticipated from an isolated building during different levels of ground shaking corresponding to various earthquake hazard levels. The proposed performance-based algorithm is based on a modified version of the well-known semi-active skyhook control algorithm. The proposed control algorithm changes the control gain depending on the level of shaking imposed on the structure. The proposed control system has been evaluated using a series of analyses performed on a base isolated benchmark building subjected to seven pairs of scaled ground motion records. Simulation results show that the newly proposed algorithm is effective in improving the structural and nonstructural performance of the building for selected earthquakes. 展开更多
关键词 structural control active control semi-active control base isolation
下载PDF
Reduced order observer based identification of base isolated buildings 被引量:2
12
作者 Satish Nagarajaiah Prasad Dharap 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2003年第2期237-244,共8页
The objective of this study is to identify system parameters from the recorded response of base isolated buildings,such as USC hospital building,during the 1994 Northridge earthquake.Full state measurements are not av... The objective of this study is to identify system parameters from the recorded response of base isolated buildings,such as USC hospital building,during the 1994 Northridge earthquake.Full state measurements are not available for identification.Additionally,the response is nonlinear due to the yielding of the lead-rubber bearings.Two new approaches are presented in this paper to solve the aforementioned problems.First,a reduced order observer is used to estimate the unmeasured states.Second,a least squares technique with time segments is developed to identify the piece-wise linear system properties.The observer is used to estimate the initial conditions needed for the time segmented identification.A series of equivalent linear system parameters are identified in different time segments.It is shown that the change in system parameters,such as frequencies and damping ratios,due to nonlinear behavior of the lead-rubber bearings,are reliably estimated using the presented technique.It is shown that the response was reduced due to yielding of the lead-rubber bearings and period lengthening. 展开更多
关键词 use hospital building base isolation least squares system identification time segments reduced order observer Northridge earthquake
下载PDF
Spring tube braces for seismic isolation of buildings 被引量:2
13
作者 V.Karayel E.Yuksel +1 位作者 T.Gokce F.Sahin 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第1期219-231,共13页
Abstract: A new low-cost seismic isolation system based on spring tube bracings has been proposed and studied at the Structural and Earthquake Engineering Laboratory of Istanbul Technical University. Multiple compres... Abstract: A new low-cost seismic isolation system based on spring tube bracings has been proposed and studied at the Structural and Earthquake Engineering Laboratory of Istanbul Technical University. Multiple compression-type springs are positioned in a special cylindrical tube to obtain a symmetrical response in tension and compression-type axial loading. An isolation floor, which consists of pin-ended steel columns and spring tube bracings, is constructed at the foundation level or any intermediate level of the building. An experimental campaign with three stages was completed to evaluate the capability of the system. First, the behavior of the spring tubes subjected to axial displacement reversals with varying frequencies was determined. In the second phase, the isolation floor was assessed in the quasi-static tests. Finally, a scaled 3D steel frame was tested on the shake table using actual acceleration records. The transmitted acceleration to the floor levels is greatly diminished because of the isolation story, which effects longer period and higher damping. There are no stability and self- centering problems in the isolation floor. 展开更多
关键词 seismic isolation spring tube base isolation low-cost isolation
下载PDF
Pseudo-Dynamic Testing for Seismic Performance Assessment of Buildings with Seismic Isolation System Using Scrap Tire Rubber Pad Isolators 被引量:6
14
作者 Huma Kanta Mishra Akira Igarashi +1 位作者 Dang Ji Hiroshi Matsushima 《Journal of Civil Engineering and Architecture》 2014年第1期73-88,共16页
Investigation of seismic performance of buildings with STRP (scrap tire rubber pad) seismic isolators by means of pseudo-dynamic tests and numerical simulation is presented. The isolated building is numerically mode... Investigation of seismic performance of buildings with STRP (scrap tire rubber pad) seismic isolators by means of pseudo-dynamic tests and numerical simulation is presented. The isolated building is numerically modeled, while the base isolation layer is considered as the experimental substructure in the pseudo-dynamic tests. The test result verifies that the STRP isolator shows acceptable shear deformation performance predicted by the design methods, and demonstrated that seismic isolation using STRP works as a protective measure to provide enhanced seismic performance of the building indicated by the reduction of top floor absolute acceleration, drift and base shear as designated. 展开更多
关键词 Pseudodynamic test STRP isolator numerical simulation base isolation seismic performance.
下载PDF
Roles of soil-structure interaction and damping in base-isolated structures built on numerous soil layers overlying a half-space 被引量:1
15
作者 C.S.Tsai C.I.Hsueh H.C.Su 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第2期387-400,共14页
This study examines the roles of soil-structure interaction (SSI), higher modes, and damping in a base-isolated structure built on multiple layers of soil overlying a half space. Closed-form solutions for the entire... This study examines the roles of soil-structure interaction (SSI), higher modes, and damping in a base-isolated structure built on multiple layers of soil overlying a half space. Closed-form solutions for the entire system, including a superstructure, seismic isolator, and numerous soil layers overlying a half-space, were obtained. The formulations obtained in this study simply in terms of well-known frequencies and mechanical impedance ratios can explicitly interpret the dynamic behavior of a base-isolated structure interacting with multiple soil layers overlying a half-space. The key factors influencing the performance of the isolation system are the damping ratio of the isolator and the ratio of the natural frequency of the fixed-base structure to that of the isolated structure by assuming that the superstructure moves as a rigid body. This study reveals that higher damping in the base isolator is unfavorable to higher mode responses that usually dominate the responses of the superstructure and that the damping mechanism plays an important role in transmitting energy in addition to absorbing energy. It is also concluded that it is possible to design a soft soil layer as an isolation system for isolating vibration energy. 展开更多
关键词 base isolation seismic isolation soil-structure interaction closed- form solution higher-mode effects soilstratum passive control damping effects
下载PDF
Seismic Response of Base-Isolated Structures underMulti-component Ground Motion Excitation
16
作者 Jiang Yicheng Tang Jiaxiang School of Civil Engineering , Huazhong University of Science and Technology, Wuhan 430074 《Journal of China University of Geosciences》 SCIE CSCD 2001年第1期90-94,共5页
An analysis of a base-isolated structure for multi-component random ground motion is presented. The mean square respond of the system is Obtained under different parametric variations. The effectiveness of main param... An analysis of a base-isolated structure for multi-component random ground motion is presented. The mean square respond of the system is Obtained under different parametric variations. The effectiveness of main parameters and the torsional component during an earthquake is quantified with the help of the response ratio and the root mean square response with and without base isolation. It is observed that the base isolation has considerable influence on the response and the effect of the torsional component is not ignored. 展开更多
关键词 multi-component ground motion base isolation random response root mean square response.
下载PDF
Seismic response reduction analysis of large chassis base-isolated structure under long-period ground motions
17
作者 Feiyan Li Linjian Wang Yingxiong Wu 《Earthquake Research Advances》 CSCD 2021年第2期49-56,共8页
Long-period structures(e.g.Isolated structures)tend to produce pseudo-resonance with low frequency compo-nents of long-period ground motions,resulting in the increase in damage.Stiffness mutation occurs due to the set... Long-period structures(e.g.Isolated structures)tend to produce pseudo-resonance with low frequency compo-nents of long-period ground motions,resulting in the increase in damage.Stiffness mutation occurs due to the set-back in the upper body of the large chassis structure.In the parts with stiffness mutation,the torsion effect caused by the tower is far greater than that of the chassis itself.In this study,a total of 273 ground motions are collected and then filtered into four types,including the near-field ordinary,near-field pulse,far-field ordinary,and far-field harmonic.An 8-degree(0.2 g)fortified large chassis base-isolated structure is established.Furthermore,ETABS program software is used to conduct nonlinear time history analysis on the isolation and seismic model under bi-directional earthquake ground motions.The comparison results show that the seismic isolation effect of the base-isolated structure under long-period ground motions is worse than that associated with ordinary ground motions when the seismic response reduction rate of the large base floor significantly decreases compared with that of the tower.When the inter-story displacement angle and the displacement of isolation layer of the chassis exceeds the limit of Code for Seismic Design of Buildings(GB 50011-2010),it is recommended to adopt composite seismic isolation technology or add limit devices.Under the condition of long-period ground motions,the base-isolated structure reduces the lateral-torsional coupling effect of the large chassis structure,while the torsion response of large chassis’top layer increases.Under long-period ground motions with the same acceleration peak,the response of the base-isolated structure increases much more than that of the seismic structure and the consideration of this impact is suggested to be added to the Code. 展开更多
关键词 Long-period ground motions Large chassis structure base isolation Seismic response reduction analysis
下载PDF
Optimal design and effectiveness evaluation for inerter-based devices on mitigating seismic responses of base isolated structures 被引量:3
18
作者 Li Yafeng Li Shouying Chen Zhengqing 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第4期1021-1032,共12页
The optimal design and effectiveness of three control systems,tuned viscous mass damper(TVMD),tuned inerter damper(TID)and tuned mass damper(TMD),on mitigating the seismic responses of base isolated structures,were sy... The optimal design and effectiveness of three control systems,tuned viscous mass damper(TVMD),tuned inerter damper(TID)and tuned mass damper(TMD),on mitigating the seismic responses of base isolated structures,were systematically studied.First,the seismic responses of the base isolated structure with each control system under white noise excitation were obtained.Then,the structural parameter optimizations of the TVMD,TID and TMD were conducted by using three different objectives.The results show that the three control systems were all effective in minimizing the root mean square value of seismic responses,including the base shear of the BIS,the absolute acceleration of structural SDOF,and the relative displacement between the base isolation floor and the foundation.Finally,considering the superstructure as a structural MDOF,a series of time history analyses were performed to investigate the effectiveness and activation sensitivity of the three control systems under far field and near fault seismic excitations.The results show that the effectiveness of TID and TMD with optimized parameters on mitigating the seismic responses of base isolated structures increased as the mass ratio increases,and the effectiveness of TID was always better than TMD with the same mass ratio.The TVMD with a lower mass ratio was more efficient in reducing the seismic response than the TID and TMD.Furthermore,the TVMD,when compared with TMD and TID,had better activation sensitivity and a smaller stroke. 展开更多
关键词 base isolated structure inerter optimal design seismic response vibration control
下载PDF
Performance of a base isolator with shape memory alloy bars 被引量:3
19
作者 Fabio Casciati Lucia Faravelli Karim Hamdaoui 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2007年第4期401-408,共8页
A new and innovative base isolation device is introduced in this paper based on extensive research carried out by the authors and their co-workers. A prototype of the device was built and experimentally tested on the ... A new and innovative base isolation device is introduced in this paper based on extensive research carried out by the authors and their co-workers. A prototype of the device was built and experimentally tested on the shaking table. The new base isolation device consists of two disks, one vertical cylinder with an upper enlargement sustained by three horizontal cantilevers, and at least three inclined shape memory alloy (SMA) bars. The role of the SMA bars is to limit the relative motion between the base and the superstructure, to dissipate energy by their super-elastic constitutive law and to guarantee the re-centring of the device. To verify the expected performance, a prototype was built and tested under sinusoidal waves of displacement of increasing frequency with different amplitudes. It is shown that the main feature of the proposed base isolation device is that for cyclic loading, the super-elastic behavior of the alloy results in wide load-displacement loops, where a large amount of energy is dissipated. 展开更多
关键词 base isolator dynamic excitation energy dissipation shape memory alloy shaking table test
下载PDF
Multi dimensional Seismic Response Analysis of Base Isolated Frame Structure with 3D Isolator 被引量:1
20
作者 XiongShishu HuangLiting ChenJinfeng SuJingsu 《Journal of China University of Geosciences》 SCIE CSCD 2005年第1期66-71,78,共7页
The three dimensional lead rubber dish spring bearing (3DB) is proposed in this paper. The 3DB is composed of lead rubber bearing (LRB) and dish spring bearing (DSB) with damper in series. The 3DB put forward in t... The three dimensional lead rubber dish spring bearing (3DB) is proposed in this paper. The 3DB is composed of lead rubber bearing (LRB) and dish spring bearing (DSB) with damper in series. The 3DB put forward in this paper is effective in the resolution of difficulties in strong vertical capacity and vertical damping of three dimensional isolation bearings. It effectively suppresses rocking motions as well. The analytical model and motion equations of multi dimensional seismic responses of 3D base isolated frame structures are established. Taking a five storey frame structure as an example, an extensive simulation analysis is carried out. The results show that the 3D base isolated structure with the proposed 3DB is effective in 3D isolation; it can reduce seismic responses by 50 % compared to a non isolated structure. Therefore, the 3D isolation problem in building can be solved easily and effectively with the 3DB proposed in this paper. 展开更多
关键词 D base isolator multi earthquake seismic responses lead rubber bearing dish spring bearing.
下载PDF
上一页 1 2 下一页 到第