期刊文献+
共找到533篇文章
< 1 2 27 >
每页显示 20 50 100
Effects of sevoflurane on left ventricular function by speckletracking echocardiography in coronary bypass patients: A randomized trial
1
作者 Chanjuan Gong Xiaokai Zhou +3 位作者 Yin Fang Yanjuan Zhang Linjia Zhu Zhengnian Ding 《The Journal of Biomedical Research》 CAS CSCD 2024年第1期76-86,共11页
The present study aimed to dynamically observe the segmental and global myocardial movements of the left ventricle during coronary artery bypass grafting by transesophageal speckle-tracking echocardiography,and to ass... The present study aimed to dynamically observe the segmental and global myocardial movements of the left ventricle during coronary artery bypass grafting by transesophageal speckle-tracking echocardiography,and to assess the effect of sevoflurane on cardiac function.Sixty-four patients scheduled for the off-pump coronary artery bypass grafting were randomly divided into a sevoflurane-based anesthesia(AS)group and a propofolbased total intravenous anesthesia(AA)group.The AS group demonstrated a higher absolute value of left ventricular global longitudinal strain than that of the AA group at both T1(after harvesting all grafts and before coronary anastomosis)and T_(2)(30 min after completing all coronary anastomoses)(P<0.05).Moreover,strain improvement in the segment with the highest preoperative strain was significantly reduced in the AS group,compared with the AA group at both T1 and T_(2)(P<0.01).The flow of the left internal mammary artery-left anterior descending artery graft was superior,and the postoperative concentration of troponin T decreased rapidly in the AS group,compared with the AA group(P<0.05).Compared with total intravenous anesthesia,sevoflurane resulted in a significantly higher global longitudinal strain,stroke volume,and cardiac output.Sevoflurane also led to an amelioration in the condition of the arterial graft.Furthermore,sevoflurane significantly reduced strain improvement in the segmental myocardium with a high preoperative strain value.The findings need to be replicated in larger studies. 展开更多
关键词 coronary artery bypass grafting speckle-tracking echocardiography SEVOFLURANE transesophageal echocardiography
下载PDF
Deep learning models semi-automatic training system for quality control of transthoracic echocardiography
2
作者 QIAN Sunnan WENG Hexiang +7 位作者 CHENG Hanlin SHI Zhongqing WANG Xiaoxian GUO Guanjun FANG Aijuan LUO Shouhua YAO Jing QI Zhanru 《中国医学影像技术》 CSCD 北大核心 2024年第8期1140-1145,共6页
Objective To explore the value of deep learning(DL)models semi-automatic training system for automatic optimization of clinical image quality control of transthoracic echocardiography(TTE).Methods Totally 1250 TTE vid... Objective To explore the value of deep learning(DL)models semi-automatic training system for automatic optimization of clinical image quality control of transthoracic echocardiography(TTE).Methods Totally 1250 TTE videos from 402 patients were retrospectively collected,including 490 apical four chamber(A4C),310 parasternal long axis view of left ventricle(PLAX)and 450 parasternal short axis view of great vessel(PSAX GV).The videos were divided into development set(245 A4C,155 PLAX,225 PSAX GV),semi-automated training set(98 A4C,62 PLAX,90 PSAX GV)and test set(147 A4C,93 PLAX,135 PSAX GV)at the ratio of 5∶2∶3.Based on development set and semi-automatic training set,DL model of quality control was semi-automatically iteratively optimized,and a semi-automatic training system was constructed,then the efficacy of DL models for recognizing TTE views and assessing imaging quality of TTE were verified in test set.Results After optimization,the overall accuracy,precision,recall,and F1 score of DL models for recognizing TTE views in test set improved from 97.33%,97.26%,97.26%and 97.26%to 99.73%,99.65%,99.77%and 99.71%,respectively,while the overall accuracy for assessing A4C,PLAX and PSAX GV TTE as standard views in test set improved from 89.12%,83.87%and 90.37%to 93.20%,90.32%and 93.33%,respectively.Conclusion The developed DL models semi-automatic training system could improve the efficiency of clinical imaging quality control of TTE and increase iteration speed. 展开更多
关键词 echocardiography quality control artificial intelligence
下载PDF
Z-Score in Fetal Echocardiography–Is there Still Room for New Studies?
3
作者 Marcio Fragoso Vieira Nathalie Jeanne Bravo-Valenzuela Edward Araujo Júnior 《Congenital Heart Disease》 SCIE 2024年第3期305-314,共10页
Congenital heart disease(CHD)is the most common type of birth defect,representing a significant cause of peri-natal morbidity and mortality.Early diagnosis of such anomalies is crucial for improving outcomes.Current pr... Congenital heart disease(CHD)is the most common type of birth defect,representing a significant cause of peri-natal morbidity and mortality.Early diagnosis of such anomalies is crucial for improving outcomes.Current pro-tocols recommend a qualitative assessment of cardiac structures using two-dimensional ultrasound(2DUS)and color Doppler imaging.In cases of suspected abnormalities,quantitative assessments through cardiac structure measurements and reference curves can aid in accurate diagnosis.Similar to centiles widely employed in obste-trics,Z-scores provide more precise quantification of various cardiac structures,particularly at the extremes of the curve.While the development of reference curves and Z-scores has progressed over the past two decades,a lack of standardization in measurements and statistical methodology for their determination is evident.Establishing reference curves requires adherence to specific recommendations to improve their accuracy.The purpose of this study is to provide a narrative review of the major studies that have generated reference values for cardiac struc-tures using 2DUS and Z-scores,to evaluate their methodology,and to provide a summary of the results. 展开更多
关键词 Z-SCORES reference ranges fetal echocardiography
下载PDF
Status of clinical applications of artificial intelligence in echocardiography
4
作者 MA Chunyan 《中国医学影像技术》 CSCD 北大核心 2024年第8期1121-1123,共3页
Artificial intelligence(AI)technology has been increasingly used in medical field with its rapid developments.Echocardiography is one of the best imaging methods for clinical diagnosis of heart diseases,and combining ... Artificial intelligence(AI)technology has been increasingly used in medical field with its rapid developments.Echocardiography is one of the best imaging methods for clinical diagnosis of heart diseases,and combining with AI could further improve its diagnostic efficiency.Though the applications of AI in echocardiography remained at a relatively early stage,a variety of automated quantitative and analytical techniques were rapidly emerging and initially entered clinical practice.The status of clinical applications of AI in echocardiography were reviewed in this article. 展开更多
关键词 echocardiography artificial intelligence
下载PDF
Intelligent diagnosis of atrial septal defect in children using echocardiography with deep learning
5
作者 Yiman LIU Size HOU +7 位作者 Xiaoxiang HAN Tongtong LIANG Menghan HU Xin WANG Wei GU Yuqi ZHANG Qingli LI Jiangang CHEN 《虚拟现实与智能硬件(中英文)》 EI 2024年第3期217-225,共9页
Background Atrial septal defect(ASD)is one of the most common congenital heart diseases.The diagnosis of ASD via transthoracic echocardiography is subjective and time-consuming.Methods The objective of this study was ... Background Atrial septal defect(ASD)is one of the most common congenital heart diseases.The diagnosis of ASD via transthoracic echocardiography is subjective and time-consuming.Methods The objective of this study was to evaluate the feasibility and accuracy of automatic detection of ASD in children based on color Doppler echocardiographic static images using end-to-end convolutional neural networks.The proposed depthwise separable convolution model identifies ASDs with static color Doppler images in a standard view.Among the standard views,we selected two echocardiographic views,i.e.,the subcostal sagittal view of the atrium septum and the low parasternal four-chamber view.The developed ASD detection system was validated using a training set consisting of 396 echocardiographic images corresponding to 198 cases.Additionally,an independent test dataset of 112 images corresponding to 56 cases was used,including 101 cases with ASDs and 153 cases with normal hearts.Results The average area under the receiver operating characteristic curve,recall,precision,specificity,F1-score,and accuracy of the proposed ASD detection model were 91.99,80.00,82.22,87.50,79.57,and 83.04,respectively.Conclusions The proposed model can accurately and automatically identify ASD,providing a strong foundation for the intelligent diagnosis of congenital heart diseases. 展开更多
关键词 Deep learning Atrial septal defect echocardiography
下载PDF
Self-Appraisal of Clinical Competence in Echocardiography of Chinese Intensivists Post Basic Echocardiography Training
6
作者 Wei He Xue-Ying Zeng +3 位作者 Hong-Min Zhang Xiao-Ting Wang Yan-Gong Chao Critical Care Ultrasound Study Group 《Chinese Medical Sciences Journal》 CAS CSCD 2023年第2期125-129,共5页
Objectives To learn the echocardiography skills of intensivists after receiving a basic critical care echocardiography training course,and investigate factors that may influence their performance.Methods We completed ... Objectives To learn the echocardiography skills of intensivists after receiving a basic critical care echocardiography training course,and investigate factors that may influence their performance.Methods We completed a web-based questionnaire that assessed the skills in ultrasound scanning techniques of intensivists who took a training course on basic critical care echocardiography held in 2019 and 2020.MannWhitney test was used to analyze the factors which might affect their performance on image acquisition,recognizing clinical syndrome,and measuring the diameter of inferior vena cava,left ventricular ejection fraction and left ventricular outflow tract velocity-time integral.Results We enrolled 554 physicians from 412 intensive care units across China.Among them,185(33.4%)reported that they had 10%-30%chance of being misled by critical care echocardiography when making therapeutic decision,and 34(6.1%)reported that the chance was greater than 30%.Intensivists who performed echocardiography under the guidance of a mentor and finished ultrasound scanning more than 10 times per week reported significant higher scores in image acquisition,clinical syndrome recognition,and quantitative measurement of inferior vena cava diameter,left ventricular ejection fraction and left ventricular outflow tract velocity-time integral than those without mentor and performing echocardiography 10 times or less per week respectively(all P 0.05).Conclusion The skills in diagnostic medical echocardiography of Chinese intensivists after a basic echocardiographic training course remain low,and further quality assurance training program is clearly warranted. 展开更多
关键词 PHYSICIAN critical care echocardiography TRAINING
下载PDF
Real-Time Remote-Mentored Echocardiography in Management of Newborns with Critical Congenital Heart Defects
7
作者 Håvard Bjerkeseth Solvin Simone Goa Diab +2 位作者 Ole Jakob Elle Henrik Holmstrøm Henrik Brun 《Congenital Heart Disease》 SCIE 2023年第5期551-559,共9页
Background:The management of suspected critical congenital heart defects(CCHD)relies on timely echocardiographic diagnosis.The availability of experienced echocardiographers is limited or even non-existent in many hos... Background:The management of suspected critical congenital heart defects(CCHD)relies on timely echocardiographic diagnosis.The availability of experienced echocardiographers is limited or even non-existent in many hospitals with obstetric units.This study evaluates remote-mentored echocardiography performed by physicians without experience in imaging of congenital heart defects(CHD).Methods:The setup included a pediatric cardiologist in a separate room,guiding a physician without experience in echocardiographic imaging of CHD in the examination of a symptomatic newborn.This remote-mentoring pair was blinded to the diagnosis of the newborn and presented with a simplified patient history.The echocardiographic images were streamed to the laptop of the mentor,along with a webcam feed showing the probe position.The task was to identify CCHD in need of immediate transfer to a pediatric cardiac surgical center.The result was compared to the previously completed echocardiographic report and the clinical decision of the patient-responsible pediatric cardiologist.Results:During 17 months,15 newborns were recruited.All six newborns with CCHD were correctly labeled by the remotementoring pair.One newborn with Tetralogy of Fallot was erroneously labeled as needing immediate transfer.Eight newborns without CCHD were correctly labeled.Conclusions:Remote-mentored echocardiography performed by examiners without experience in imaging CHD identified all newborns with CCHD in need of immediate transfer for specialist care.The setup shows promising results for improving the management of CCHD in hospitals without continuous pediatric cardiology service. 展开更多
关键词 Remote-mentoring echocardiography TELEMEDICINE congenital heart defect
下载PDF
Current role and future perspectives of artificial intelligence in echocardiography
8
作者 Rafael Vidal-Perez Julia Grapsa +2 位作者 Alberto Bouzas-Mosquera Ricardo Fontes-Carvalho Jose Manuel Vazquez-Rodriguez 《World Journal of Cardiology》 2023年第6期284-292,共9页
Echocardiography is an essential tool in diagnostic cardiology and is fundamental to clinical care.Artificial intelligence(AI)can help health care providers serving as a valuable diagnostic tool for physicians in the ... Echocardiography is an essential tool in diagnostic cardiology and is fundamental to clinical care.Artificial intelligence(AI)can help health care providers serving as a valuable diagnostic tool for physicians in the field of echocardiography specially on the automation of measurements and interpretation of results.In addition,it can help expand the capabilities of research and discover alternative pathways in medical management specially on prognostication.In this review article,we describe the current role and future perspectives of AI in echocardiography. 展开更多
关键词 echocardiography Artificial intelligence Machine learning Deep learning PROGNOSIS
下载PDF
Analysis of the Diagnostic Value of Echocardiography in Patients with Chronic Heart Failure
9
作者 Weiqian Shi 《Journal of Clinical and Nursing Research》 2023年第5期149-154,共6页
Objective:This study aims to analyze the diagnostic value of echocardiography in patients with chronic heart failure.Methods:30 patients with chronic heart failure admitted to our hospital during January 2021 to Janua... Objective:This study aims to analyze the diagnostic value of echocardiography in patients with chronic heart failure.Methods:30 patients with chronic heart failure admitted to our hospital during January 2021 to January 2023 were selected as the observation group,and 30 healthy people who received physical examination in our hospital during the same period were selected as the reference group.Both groups received echocardiography,and the results of the ultrasound examination were compared,and the subjects in the observation group were grouped according to the New York Heart Association(NYHA)cardiac function grading standard.The results of echocardiography in patients with chronic heart failure of different cardiac function grades were compared.Results:The left ventricular ejection fraction(LVEF)and ratio of maximum blood flow in the early diastole(E)to movement speed(A)(E/A)in the observation group were lower than those in the reference group,while the left ventricular posterior wall thickness(LVPWd),left ventricular end-diastolic diameter(LVEDD),left ventricular end-systolic diameter(LVESD),left atrial diameter(LAD),and interventricular septal thickness(IVS)were higher than those of the reference group(P<0.05).With the continuous increase of cardiac function grades,the levels of LVEF and E/A in patients with chronic heart failure continued to decrease,while the levels of LVPWd,LVEDD,LVESD,LAD,and IVS continued to increase,and there were significant differences among the groups(P<0.05).Conclusion:The application of echocardiography in the clinical diagnosis of chronic heart failure can accurately evaluate the changes of cardiac shape and cardiac function,and provide a reliable basis for clinical diagnosis with a high application value. 展开更多
关键词 Chronic heart failure echocardiography Cardiac function
下载PDF
Catheter ablation of atrial fibrillation facilitated by preprocedural three-dimensional transesophageal echocardiography: Long-term outcome 被引量:3
10
作者 Klaus Kettering Felix Gramley Stephan von Bardeleben 《World Journal of Cardiology》 CAS 2017年第6期539-546,共8页
AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echo... AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echocardiography(3D TEE) was performed immediately prior to an ablation procedure(paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout the ablation procedure. Two different ablation strategies were used. In most of the patients with paroxysmal AF, the cryoablation technique was used(Arctic Front Balloon, Cryo Cath Technologies/Medtronic; group A2). In the other patients, a circumferential pulmonary vein ablation was performed using the CARTO system [Biosense Webster; group A1(paroxysmal AF), group B(persistent AF)]. Success rates and complication rates were analysed at 4-year follow-up.RESULTS A 3D TEE could be performed successfully in all patients prior to the ablation procedure and all four pulmonaryvein ostia could be evaluated in 84% of patients. The image quality was excellent in the majority of patients and several variations of the pulmonary vein anatomy could be visualized precisely(e.g., common pulmonary vein ostia, accessory pulmonary veins, varying diameter of the left atrial appendage and its distance to the left superior pulmonary vein). All ablation procedures could be performed as planned and almost all pulmonary veins could be isolated successfully. At 48-mo followup, 68.0% of all patients were free from an arrhythmia recurrence(group A1: 72.7%, group A2: 73.7%, group B: 60.0%). There were no major complications.CONCLUSION3 D TEE provides an excellent overview over the left atrial anatomy prior to AF ablation procedures and these procedures are associated with a favourable long-term outcome. 展开更多
关键词 肺的静脉 导管脱离 Atrial 纤维性颤动 Transesophageal echocardiography 三维的 echocardiography
下载PDF
Evaluation of Atrial Septal Defect Using Real-time Three-dimensional Echocardiography:Comparison with Surgical Findings 被引量:2
11
作者 Saumu Tobbi Mweri 邓又斌 +12 位作者 程佩萱 林汉华 王宏伟 Ommari Baaliy Mkangara 夏治 胡秀芬 毕小军 伍玉晗 Mustaafa Bapumiia 申屠伟慧 刘蓉 刘娅妮 朱美华 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第2期257-259,共3页
The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical find... The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes. 展开更多
关键词 real-time three-dimensional echocardiography atrial septal defect two dimensional echocardiography
下载PDF
Incremental value of three-dimensional and contrast echocardiography in the evaluation of endocardial fibroelastosis and multiple cardiovascular thrombi: A case report 被引量:1
12
作者 Li-Juan Sun Ying Li +2 位作者 Wei Qiao Jia-Hui Yu Wei-Dong Ren 《World Journal of Clinical Cases》 SCIE 2021年第14期3365-3371,共7页
BACKGROUND Endocardial fibroelastosis(EFE)is a rare heart disease characterized by thickening of the endocardium caused by massive proliferation of collagenous and elastic tissue,usually leading to impaired cardiac fu... BACKGROUND Endocardial fibroelastosis(EFE)is a rare heart disease characterized by thickening of the endocardium caused by massive proliferation of collagenous and elastic tissue,usually leading to impaired cardiac function.Multimodality cardiovascular imaging for the evaluation of EFE with thrombi is even rarer.CASE SUMMARY We report a rare case of EFE associated with multiple cardiovascular thrombi.Three-dimensional(3D)and contrast echocardiography(CE)were used to assess ventricular thrombi.Anticoagulant therapy was administered to eliminate the thrombi.The peripheral contrast-enhanced thrombi with the highest risk were dissolved with anticoagulant therapy at the time of reexamination,which was consistent with the presumption of fresh loose thrombi.CONCLUSION This new echocardiography technique has a great advantage in the diagnosis and treatment of EFE.On the basis of conventional echocardiography,3D echocardiography is used to display the position,shape,and narrow base of the thrombus.CE does not only help to confirm the diagnosis of thrombus,but also determines its risk. 展开更多
关键词 Endocardial fibroelastosis Three-dimensional echocardiography Contrast echocardiography THROMBOSIS Left ventricle Case report
下载PDF
Misdiagnosis of unroofed coronary sinus syndrome as an ostium primum atrial septal defect by echocardiography:A case report 被引量:1
13
作者 Jin-Ling Chen Cai-Gui Yu +1 位作者 Dai-Jiao Wang Hong-Bin Chen 《World Journal of Clinical Cases》 SCIE 2022年第5期1592-1597,共6页
BACKGROUND Unroofed coronary sinus syndrome(UCSS)is a rare congenital heart disease,which has variable morphologic features and is strongly associated with persistent left superior vena cava(PLSVC).However,it is often... BACKGROUND Unroofed coronary sinus syndrome(UCSS)is a rare congenital heart disease,which has variable morphologic features and is strongly associated with persistent left superior vena cava(PLSVC).However,it is often difficult to visualize the left-to-right shunt pathway through the CS by transthoracic echocardiography(TTE).CASE SUMMARY A 37-year-old female was admitted to the hepatological surgery department of a hospital with complaint of subxiphoid pain that had started 1 wk prior.Physical examination revealed a grade 3/6 systolic murmur at the left margin of the sternum,between the 2nd and 3rd intercostal cartilage.The patient underwent echocardiography and was diagnosed with ostium primum atrial septal defect(ASD);thus,she was subsequently transferred to the cardiovascular surgery department.A second TTE evaluation before surgery showed type IV UCSS with secundum ASD.Right-heart contrast echocardiography(RHCE)showed that the right atrium and right ventricle were immediately filled with microbubbles,but no microbubble was observed in the CS.Meanwhile,negative filling was observed at the right atrium orifice of the CS and right atrium side of the secundum atrial septal.RHCE identified UCSS combined with secundum ASD but without PLSVC in this patient.CONCLUSION This rare case of UCSS highlights the value of TTE combined with RHCE in confirming UCSS with ASD or PLSVC. 展开更多
关键词 Congenital heart disease Coronary sinus Atrial septal defect Persistent left superior vena cava echocardiography Right heart contrast echocardiography Case report
下载PDF
Research and Application of Transnasal Transesophageal Echocardiography Probe 被引量:1
14
作者 王蕾 张静 +4 位作者 郑少萍 贺林 王静 王新房 谢明星 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第5期782-786,共5页
The intubation of conventional transesophageal echocardiography(TEE) probes into patients causes serious esophagus irritation, and thus the use of TEE probes in pediatric practice is limited. In this study, we aimed... The intubation of conventional transesophageal echocardiography(TEE) probes into patients causes serious esophagus irritation, and thus the use of TEE probes in pediatric practice is limited. In this study, we aimed at the development of a special probe which could be inserted through the nasopharyngeal cavity into the esophagus to obtain the same high-quality echocardiography images as those obtained by conventional TEE and improve patients' experience. During the examination, the patients felt relaxed for a longer time and cooperated with the sonographers in the process of cardiac catheterization conducted in the surgery room or the intensive care unit(ICU), resulting in improved accuracy of the diagnosis and timely administration of appropriate treatment. Two years ago, Prof. Xin-fang WANG put theories into practice by inserting the probe through the nasal cavity and pharynx into the esophagus of volunteers to successfully detect the heart and great vessels at the retrocardiac space. Later, Prof. Ming-xing XIE performed the transnasal TEE examination in 12 atrial septal defect(ASD) patients and proved the safety and reliability of this method, which could become a new way for clinical diagnosis and treatment. 展开更多
关键词 transesophageal echocardiography atrial septal defect transthoracic echocardiography
下载PDF
Computed tomography versus transthoracic echocardiography in the detection of complex congenial heart diseases in china:a meta-analysis
15
作者 畅智慧 LIN Kun +3 位作者 DU Xiao-li YIN Xiao-li LU Zhao 刘兆玉 《放射学实践》 2012年第11期1168-1173,共6页
Objective:To perform a meta-analysis to evaluate the diagnostic performance of computed tomography(CT) and transthoracic echocardiography(TTE) in complex congenital heart diseases(CHD) in China.Methods:MEDLINE,Cochran... Objective:To perform a meta-analysis to evaluate the diagnostic performance of computed tomography(CT) and transthoracic echocardiography(TTE) in complex congenital heart diseases(CHD) in China.Methods:MEDLINE,Cochrane library and China National Knowledge Infrastructure(CNKI) database from January 1966 to October 2010,were searched for initial studies in China.All the studies,published in English or Chinese,used TTE,CT,or both as diagnostic tests for CHD and reported the rate of true-positive,true-negative,false-positive and false-negative diagnoses of CHD from TTE and CT findings with the surgical results as the 'gold-standard'(15 studies,XX patients) were collected.The statistic software package,'Meta-Disc 1.4',was used to conduct data analysis.A covariate analysis was used to evaluate the influence of patient or study-related factors on sensitivity.Results:Pooled sensitivity for diagnosis of CHD were 95% [95% confidence interval(CI):94%~96%] for CT studies and 87%(95% CI:85%~88%) for TTE studies.The difference between the pooled sensitivity of CT and that of TTE was statistically significant(P<0.001).TTE had higher sensitivity [0.96(95% CI:0.94~0.97)] for cardiac malformation but lower sensitivity [0.78(95% CI:0.76~0.81)] for extracardiac malformation than CT.Conclusion:CT can provide added diagnostic information compared with TTE in patients with CHD in China,especially for patients suspected of extracardiac malformation. 展开更多
关键词 echocardiography Tomography X-ray computed Heart Defects Congenital META-ANALYSIS
下载PDF
Large Anterior Mediastinal Mass: Intraoperative Transesophageal Echocardiography Guided Evaluation and Management
16
作者 Kulbhushan Saini Sandeep Chauhan Manu Saini 《World Journal of Cardiovascular Surgery》 2021年第8期69-74,共6页
The authors report a case of Large Anterior mediastinal mass in which Transoesophageal Echocardiography (TEE) revealed a large mass that was compressing the right atrium, SVC, henceforth, TEE helped in guid</span&g... The authors report a case of Large Anterior mediastinal mass in which Transoesophageal Echocardiography (TEE) revealed a large mass that was compressing the right atrium, SVC, henceforth, TEE helped in guid</span><span style="font-size:10.0pt;font-family:"">ing</span><span style="font-size:10.0pt;font-family:""> aspiration and surgical resection of the cystic mass. Therefore, through this case report, <span>authors emphasize the importance of performing intraoperative real-time</span> TEE in the mediastinal mass. This imaging technique helps in visualizing the external compression of cardio-vascular structure and aid in their management, obviating the possibility of large vascular structures from being injured by the surgeon during intraoperative manipulation. 展开更多
关键词 Transoesophageal echocardiography Superior Vena Cava Trans Thoracic echocardiography Computed Tomography Right Atrium Inferior Vena Cava
下载PDF
Two-dimensional speckle tracking echocardiography for the assessment of atrial function 被引量:40
17
作者 Tomás Francisco Cianciulli María Cristina Saccheri +2 位作者 Jorge Alberto Lax Alejandra Marina Bermann Daniel Ernesto Ferreiro 《World Journal of Cardiology》 CAS 2010年第7期163-170,共8页
Echocardiography is the most common diagnostic method for assessing atrial function but the technique has some limitations. Traditionally, assessment of left atrial function has been performed by measuring volumes wit... Echocardiography is the most common diagnostic method for assessing atrial function but the technique has some limitations. Traditionally, assessment of left atrial function has been performed by measuring volumes with 2D echocardiography. Additionally, it can be assessed with transmitral Doppler and pulmonary vein Doppler. Recently, an alternative method has been incorporated, namely, measurement of myocardial deformation with color tissue Doppler-derived strain. However, this method has several limitations, such as suboptimal reproducibility, angle-dependence, signal artifacts and the fact that it only measures regional strain and does not obtain information about the curved portion of the atrial roof. To overcome these limitations in the quantification of atrial function, the use of speckle tracking echocardiography (STE) strain has been proposed. This technique is not derived from Doppler but rather from 2D echocardiography; it is angle-independent and allows one to measure global as well as regional atrial strain. In this editorial, we describe the physical and pathophysiological concepts of STE and underline the clinical usefulness of this new technique. 展开更多
关键词 ATRIAL function SPECKLE tracking echocardiography Longitudinal ATRIAL STRAIN ATRIAL reservoir STRAIN Passive CONDUIT Active PUMP
下载PDF
Speckle tracking echocardiography:A new approach to myocardial function 被引量:19
18
作者 Simona Sitia Livio Tomasoni Maurizio Turiel 《World Journal of Cardiology》 CAS 2010年第1期1-5,共5页
Echocardiography is the most common diagnostic method for assessing cardiac function but some limitations affect this technique.Until now,visual assessment of wall motion and thickening has allowed only a subjective e... Echocardiography is the most common diagnostic method for assessing cardiac function but some limitations affect this technique.Until now,visual assessment of wall motion and thickening has allowed only a subjective evaluation of myocardial function and requires long-term training.Recently,new echocardiographic techniques have been introduced to evaluate myocardial mechanics.Tissue Doppler imaging(TDI)technique is limited by angle-dependency such that only deformation along the ultrasound beam can be derived from velocities,while myocardium deforms simultaneously in three dimensions.Speckle tracking echocardiography (STE)is a more recent technique that provides a global approach to left ventricular myocardial mechanics,giving information about the three spatial dimensions of cardiac deformation.In this editorial,we describe the physical and pathophysiological concepts of STE,discussing the differences compared to TDI and underlining the pitfalls of this new technique. 展开更多
关键词 MYOCARDIAL function SPECKLE TRACKING echocardiography TISSUE DOPPLER imaging
下载PDF
Myocardial perfusion echocardiography and coronary microvascular dysfunction 被引量:13
19
作者 Giuseppe Barletta Maria Riccarda Del Bene 《World Journal of Cardiology》 CAS 2015年第12期861-874,共14页
Our understanding of coronary syndromes has evolved in the last two decades out of the obstructive atherosclerosis of epicardial coronary arteries paradigm to include anatomo-functional abnormalities of coronary micro... Our understanding of coronary syndromes has evolved in the last two decades out of the obstructive atherosclerosis of epicardial coronary arteries paradigm to include anatomo-functional abnormalities of coronary microcirculation. No current diagnostic technique allows direct visualization of coronary microcirculation,but functional assessments of this circulation are possible. This represents a challenge in cardiology. Myocardial contrast echocardiography(MCE) was a breakthrough in echocardiography several years ago that claimed the capability to detect myocardial perfusion abnormalities and quantify coronary blood flow. Research demonstrated that the integration of quantitative MCE and fractional flow reserve improved the definition of ischemic burden and the relative contribution of collaterals in non-critical coronary stenosis. MCE identified no-reflow and low-flow within and around myocardial infarction,respectively,and predicted the potential functional recovery of stunned myocardium using appropriate interventions. MCE exhibited diagnostic performances that were comparable to positron emission tomography in microvascular reserve and microvascular dysfunction in angina patients. Overall,MCE improved echocardiographic evaluations of ischemic heart disease in daily clinical practice,but the approval of regulatory authorities is lacking. 展开更多
关键词 Contrast echocardiography MYOCARDIAL PERFUSION MYOCARDIAL ISCHEMIA MICROVASCULAR ANGINA Coronary flow
下载PDF
Subclinical carotid atherosclerosis predicts all-cause mortality and cardiovascular events in obese patients with negative exercise echocardiography 被引量:8
20
作者 Rafael Vidal-Perez Raúl Franco-Gutiérrez +5 位作者 Alberto J Pérez-Pérez Virginia Franco-Gutiérrez Alberto Gascón-Vázquez Andrea López-López Ana María Testa-Fernández Carlos González-Juanatey 《World Journal of Cardiology》 CAS 2019年第1期24-36,共13页
BACKGROUND Obesity is a major health problem due to its high prevalence. The relationship between obesity and cardiovascular disease is unclear. Some studies agree that certain conditions associated with obesity, such... BACKGROUND Obesity is a major health problem due to its high prevalence. The relationship between obesity and cardiovascular disease is unclear. Some studies agree that certain conditions associated with obesity, such as physical inactivity or cardiovascular risk factors, are responsible for cardiovascular risk excess among obese people. Carotid intima-media thickness and carotid plaques(CP) have been associated with cardiovascular adverse events in healthy populations, and recent data suggest a higher prevalence of subclinical carotid atherosclerosis in obese and metabolically unhealthy patients. However, there are no studies correlating subclinical atherosclerosis and adverse events(AE) in obese subjects.AIM To determine the association between carotid disease and AE in obese patients with negative exercise echocardiography(EE).METHODS From January 1, 2006 to December 31, 2010, 2000 consecutive patients with a suspicion of coronary artery disease were submitted for EE and carotid ultrasonography. Exclusion criteria included previous vascular disease, left ventricular ejection fraction < 50%, positive EE, significant valvular heart disease and inferior to submaximal EE. An AE was defined as all-cause mortality,myocardial infarction and cerebrovascular accident. Subclinical atherosclerosis was defined as CP presence according to Manheim and the American Society of Echocardiography Consensus.RESULTS Of the 652 patients who fulfilled the inclusion criteria, 226(34.7%) had body mass indexes ≥ 30 kg/m2, and 76 of them(33.6%) had CP. During a mean follow-up time of 8.2(2.1) years, 27 AE were found(11.9%). Mean event-free survival at 1, 5 and 10 years was 99.1%(0.6), 95.1%(1.4) and 86.5%(2.7), respectively. In univariate analysis, CP predicted AE [hazard ratio(HR) 2.52, 95% confidence interval(CI) 1.17-5.46; P = 0.019]. In multivariable analysis, the presence of CP remained a predictor of AE(HR 2.26, 95%CI 1.04-4.95, P = 0.041). Other predictors identified were glomerular filtration rate(HR 0.98, 95%CI 0.96-0.99; P= 0.023), peak metabolic equivalents(HR 0.83, 95%CI 0.70–0.99, P = 0.034) and moderate mitral regurgitation(HR 5.02, 95%CI 1.42–17.75, P = 0.012).CONCLUSION Subclinical atherosclerosis defined by CP predicts AE in obese patients with negative EE. These patients could benefit from aggressive prevention measures. 展开更多
关键词 CAROTID INTIMA media thickness CAROTID PLAQUE CAROTID disease Myocardial INFARCTION Mortality Stroke Exercise stress echocardiography
下载PDF
上一页 1 2 27 下一页 到第
使用帮助 返回顶部