期刊文献+
共找到161篇文章
< 1 2 9 >
每页显示 20 50 100
Mitigation of Transients in Capacitor Coupled Substations Using Traditional RLC Filter Techniques
1
作者 Sinqobile Wiseman Nene Bolanle Tolulope Abe Agha Francis Nnachi 《Journal of Power and Energy Engineering》 2024年第5期60-75,共16页
This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly f... This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly from high-voltage (HV) transmission lines to low-voltage (LV) consumers through coupling capacitors and is said to be cost-effective as compared to conventional distribution networks. However, the functionality of such substations is susceptible to various transient phenomena, including ferroresonance and overvoltage occurrences. To address these challenges, the study uses simulations to evaluate the effectiveness of conventional resistor-inductor-capacitor (RLC) filter in mitigating hazardous overvoltage resulting from transients. The proposed methodology entails using standard RLC filter to suppress transients and its associated overvoltage risks. Through a series of MATLAB/Simulink simulations, the research emphasizes the practical effectiveness of this technique. The study examines the impact of transients under varied operational scenarios, including no-load switching conditions, temporary short-circuits, and load on/off events. The primary aim of the article is to assess the viability of using an established technology to manage system instabilities upon the energization of a CCS under no-load circumstances or in case of a short-circuit fault occurring on the primary side of the CCS distribution transformer. The findings underscore the effectiveness of conventional RLC filters in suppressing transients induced by the CCS no-load switching. 展开更多
关键词 Capacitor Coupled substation System Modeling FERRORESONANCE RLC filters Power Electronics Transients Capacitor Voltage Transformers Transmission Lines
下载PDF
Mathematical Modeling of Multiple Capacitor Coupled Substations (CCS) Impact on Transmission Lines and Approaches for Ferroresonance Suppression
2
作者 Sinqobile Wiseman Nene 《Open Journal of Modelling and Simulation》 2024年第4期101-113,共13页
Rural electrification remains a critical challenge in achieving equitable access to electricity, a cornerstone for poverty alleviation, economic growth, and improved living standards. Capacitor Coupled Substations (CC... Rural electrification remains a critical challenge in achieving equitable access to electricity, a cornerstone for poverty alleviation, economic growth, and improved living standards. Capacitor Coupled Substations (CCS) offer a promising solution for delivering cost-effective electricity to these underserved areas. However, the integration of multiple CCS units along a transmission network introduces complex interactions that can significantly impact voltage, current, and power flow. This study presents a detailed mathematical model to analyze the effects of varying distances and configurations of multiple CCS units on a transmission network, with a focus on voltage stability, power quality, and reactive power fluctuations. Furthermore, the research addresses the phenomenon of ferroresonance, a critical issue in networks with multiple CCS units, by developing and validating suppression strategies to ensure stable operation. Through simulation and practical testing, the study provides insights into optimizing CCS deployment, ultimately contributing to more reliable and efficient rural electrification solutions. 展开更多
关键词 Capacitor Coupled substation FERRORESONANCE Power System Modelling Algorithm Presentation Rural Electrification
下载PDF
Substation clustering based on improved KFCM algorithm with adaptive optimal clustering number selection 被引量:1
3
作者 Yanhui Xu Yihao Gao +4 位作者 Yundan Cheng Yuhang Sun Xuesong Li Xianxian Pan Hao Yu 《Global Energy Interconnection》 EI CSCD 2023年第4期505-516,共12页
The premise and basis of load modeling are substation load composition inquiries and cluster analyses.However,the traditional kernel fuzzy C-means(KFCM)algorithm is limited by artificial clustering number selection an... The premise and basis of load modeling are substation load composition inquiries and cluster analyses.However,the traditional kernel fuzzy C-means(KFCM)algorithm is limited by artificial clustering number selection and its convergence to local optimal solutions.To overcome these limitations,an improved KFCM algorithm with adaptive optimal clustering number selection is proposed in this paper.This algorithm optimizes the KFCM algorithm by combining the powerful global search ability of genetic algorithm and the robust local search ability of simulated annealing algorithm.The improved KFCM algorithm adaptively determines the ideal number of clusters using the clustering evaluation index ratio.Compared with the traditional KFCM algorithm,the enhanced KFCM algorithm has robust clustering and comprehensive abilities,enabling the efficient convergence to the global optimal solution. 展开更多
关键词 Load substation clustering Simulated annealing genetic algorithm Kernel fuzzy C-means algorithm Clustering evaluation
下载PDF
Experimental investigation and analytically modeling of hysteretic behavior of rigid bus-flexible connectors of 220 kV electrical substations
4
作者 Tang Tingxuan He Jun 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2023年第3期841-852,共12页
This paper describes the quasi-static testing and analytical modelling of the hysteretic behavior of aluminum alloy rigid bus-flexible connectors of 220 kV electrical substations.The main objective of the study is to ... This paper describes the quasi-static testing and analytical modelling of the hysteretic behavior of aluminum alloy rigid bus-flexible connectors of 220 kV electrical substations.The main objective of the study is to experimentally investigate the hysteretic behavior of six different types of rigid bus-flexible connectors 220 kV electrical substations when subjected to cyclic loading.Another objective is to theoretically study the flexibility and effectiveness of a previously proposed analytical model in fitting the experimental hysteresis loops of the tested rigid bus-flexible connectors.The experimental investigation indicates that the tested rigid bus-flexible connectors exhibit highly asymmetric hysteresis behavior along with tension stiffening effect.The theoretical study demonstrates that the generalized Bouc-Wen model has high flexibility and is effective in fitting the experimental hysteresis resisting force-displacement curves of the six tested rigid bus-flexible connectors. 展开更多
关键词 rigid bus-flexible connectors 220 kV electrical substations hysteretic behavior experimental curves analytical model
下载PDF
Modeling and Simulation of a Transmission Line Response to a 400 kV/400V Capacitor Coupled Substation
5
作者 Sinqobile Wiseman Nene Bolanle Tolulope Abe Agha Francis Nnachi 《Journal of Power and Energy Engineering》 2023年第12期1-14,共14页
The access to electricity in rural areas is extremely limited, but it is crucial for all citizens. The population in rural areas of sub-Saharan African (SSA) countries is generally low, making it economically unfeasib... The access to electricity in rural areas is extremely limited, but it is crucial for all citizens. The population in rural areas of sub-Saharan African (SSA) countries is generally low, making it economically unfeasible to implement traditional rural electrification (CRE) projects due to the high cost of establishing the necessary distribution infrastructure. To address this cost issue, one alternative technology for rural electrification (URE) that can be explored is the Capacitor Coupled Substation (CCS) technology. CCS is a cost-effective solution for supplying electricity to rural areas. The research is necessitated by the need to offer a cost-effective technology for supplying electricity to sparsely populated communities. This paper examines the impact on the transmission network when a 400 kV/400V CCS is connected to it. The system response when a CCS is connected to the network was modeled using MATLAB/Si-mulink. The results, based on the fixed load of 80 kW, showed negligible interference on the transmission line voltage. However, there was minor impact on the parameters downstream of the tapping point. These findings were further supported by introducing a fault condition to the CCS, which showed that interferences with the CCS could affect the overall stability of the transmission network downstream of the tapping node, similar to the behavior of an unstable load. 展开更多
关键词 Capacitor Coupled substation Conventional Rural Electrification Unconventional Rural Electrification Transmission Line Behavior Power System Simulation
下载PDF
Intelligent Detection Method of Substation Environmental Targets Based on MD-Yolov7
6
作者 Tao Zhou Qian Huang +1 位作者 Xiaolong Zhang Yong Zhang 《Journal of Intelligent Learning Systems and Applications》 2023年第3期76-88,共13页
The complex operating environment in substations, with different safety distances for live equipment, is a typical high-risk working area, and it is crucial to accurately identify the type of live equipment during aut... The complex operating environment in substations, with different safety distances for live equipment, is a typical high-risk working area, and it is crucial to accurately identify the type of live equipment during automated operations. This paper investigates the detection of live equipment under complex backgrounds and noise disturbances, designs a method for expanding lightweight disturbance data by fitting Gaussian stretched positional information with recurrent neural networks and iterative optimization, and proposes an intelligent detection method for MD-Yolov7 substation environmental targets based on fused multilayer feature fusion (MLFF) and detection transformer (DETR). Subsequently, to verify the performance of the proposed method, an experimental test platform was built to carry out performance validation experiments. The results show that the proposed method has significantly improved the performance of the detection accuracy of live devices compared to the pairwise comparison algorithm, with an average mean accuracy (mAP) of 99.2%, which verifies the feasibility and accuracy of the proposed method and has a high application value. 展开更多
关键词 substation Target Detection Deep Learning Multi-Layer Feature Fusion Unmanned Vehicles
下载PDF
Design Of MV/LV Substation Transformer 被引量:1
7
作者 Sabir MESSALTI Fares Zitouni Issam Griche 《Engineering(科研)》 2013年第1期20-25,共6页
A substation is a part of an electrical generation, transmission, and distribution system. Substations generally have switching, protection and control equipment, and transformers. The low voltage distribution network... A substation is a part of an electrical generation, transmission, and distribution system. Substations generally have switching, protection and control equipment, and transformers. The low voltage distribution networks are supplied from MV/LV substation transformer that represent the last step of bringing transformation to the? low voltage and ensuring the? protection and monitoring of the network. There are three types of MV/LV substation: pole-mounted transformer substation, the substation in an envelope and substation in masonry. This paper presents a general description for different MV/LV substation and a methodology to design the various elements making up the public distribution substation (choice of the emplacement, engineering, power transformer, choice of MV cells, circuit breakers, fuses, disconnect? switch, conductors,...etc). 展开更多
关键词 substation TRANSFORMER MV cells substation in MASONRY pole-mounted TRANSFORMER substation.
下载PDF
Improved complex filter applied in enhancing EFT/B immunity at a coal mine monitoring substation 被引量:13
8
作者 SUN Ji-ping MA Feng-ying LIChen 《Journal of China University of Mining and Technology》 EI 2008年第1期22-26,共5页
A monitoring system is an important guarantee of safety in a production mine. However, not all monitoring substations pass the electrical fast transient/burst (EFT/B) immunity test and the explosion-proof test simul... A monitoring system is an important guarantee of safety in a production mine. However, not all monitoring substations pass the electrical fast transient/burst (EFT/B) immunity test and the explosion-proof test simultaneously. To enhance the immunity, the values of capacitance and inductance should be increased, which are actually limited by coal mine explosion-proof standards. Hence, for the first time, an active filter was applied in an electromagnetic interference (EMI) output filter. As a result, the interference within 30 MHz clearly weakened, but the frequency spectrum had a wide range. An EMI input filter and ferrite beads were adopted to restrain higher frequency interference. An output interference spectrogram of the substation was obtained with an analyzer. The results indicate that the improved complex filtering markedly help to control interference. With the support of improved complex filtering and other enhancing immunity means about I/O ports, the substation managed to pass both the EFT/B immunity test and the explosion-proof test synchronously. We conclude that improved complex filtering is of vital importance in enhancing the electromagnetic compatibilitv (EMC) of the coal mine monitoring system. 展开更多
关键词 EFT/B coal mine monitoring substation IMMUNITY complex filter EMC
下载PDF
Comparative analysis of online monitoring methods for transformer insulation performance of 330-750kV substation
9
作者 子贡 董海鹰 任伟 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2016年第1期71-77,共7页
The online-monitoring methods for insulation performance of current transformers of 330-750 kV substation are analyzed and compared.The effectiveness and availability of each method are discussed.Main features,advanta... The online-monitoring methods for insulation performance of current transformers of 330-750 kV substation are analyzed and compared.The effectiveness and availability of each method are discussed.Main features,advantages and disadvantages of each method and its corresponding standard are also described. 展开更多
关键词 continuous control insulation performance online monitoring substation
下载PDF
Maximum Inner Product Method for Extracting the Path-Loss Parameters in Primary Transformer Substations 被引量:2
10
作者 Qiang Li Hongxin Zhang +2 位作者 Tianyi Zheng Xueli Wang Yinghua Lv 《China Communications》 SCIE CSCD 2019年第4期120-129,共10页
In order to deploy short-range wireless communication devices in the primary transformer substation, a Maximum Inner Product(MIP) Method is proposed to extract the path-loss parameters in 110 kV and 220 kV primary tra... In order to deploy short-range wireless communication devices in the primary transformer substation, a Maximum Inner Product(MIP) Method is proposed to extract the path-loss parameters in 110 kV and 220 kV primary transformer substations. The maximum inner product of the testing data is calculated to find out the loss index n and the standard deviation σ, and then the pathloss models can be set up. By comparing the MIP with Minimum Mean Square estimation(MMSE) and Cumulative Sum(CUSUM), MIP can match the measured values best. In order to apply the MIP path-loss model, under the initial signal to noise ratio(SNR) at 5 dB and 10 dB, a ZigBee simulation system is constructed to validate the situation that bit error rate(BER) varies with distance. And the ZigBee devices with 5 units are tested in a 220 kV primary transformer substation. The result of the test proves that the path-loss model is accurate. 展开更多
关键词 PRIMARY transformer substation path-loss ZigBee
下载PDF
Network Multifunctional Substation with Embedded System in Coal Mine 被引量:3
11
作者 MENG Fan-rong HUO Yan ZHOU Yong 《Journal of China University of Mining and Technology》 EI 2006年第2期236-240,共5页
In order to solve the problems of mining monitor and control systems during the construction process of digital mining combined with network and embedded technologies, the kernel access equipment of a mining monitor a... In order to solve the problems of mining monitor and control systems during the construction process of digital mining combined with network and embedded technologies, the kernel access equipment of a mining monitor and control system was proposed and designed. It is the architecture of a mining embedded network multifunctional substation. This paper presents the design of hardware and software of the substation in detail. Finally, the system’s ef- ficiency was validated through experimentation. 展开更多
关键词 mining EMBEDMENT network multifunctional substation architecture
下载PDF
Research on Communication Network Configuration and Simulation of Smart Substation Based on Ethernet 被引量:2
12
作者 Jingxia Liu Xuerang Zhang Fuquan Zhang 《Energy and Power Engineering》 2020年第4期14-24,共11页
The characters of the intelligent substation communication network structure are analyzed in the paper. Combining existing integrated automation substation hardware circuit and VLAN (Virtual Local Area Network) resear... The characters of the intelligent substation communication network structure are analyzed in the paper. Combining existing integrated automation substation hardware circuit and VLAN (Virtual Local Area Network) research foundation to optimize the network configuration. In accordance with IEC61850 standard, the network is partitioned into several VLANs based on the Tag VLAN division method of ID address. Real-time communication packets between GOOSE networks, SV (sampling information) networks, and switches use 802.1Q protocol headers to distinguish these packets. Finally, OPNET simulation software was used to simulate and verify the simplified dual-star topology. The results demonstrate that the delay and traffic bandwidth meet the requirements of actual substation operation standards. Compared with ordinary single-star networks, the reliability is greatly improved and the effectiveness is improved. 展开更多
关键词 Intelligent substation Network Configuration VLAN Division GOOSE and SV OPNET
下载PDF
Effect Evaluation and Intelligent Prediction of Power Substation Project Considering New Energy 被引量:1
13
作者 Huiying Wu Meihua Zou +3 位作者 Ye Ke Wenqi Ou Yonghong Li Minquan Ye 《Computer Modeling in Engineering & Sciences》 SCIE EI 2022年第9期739-761,共23页
The evaluation of the implementation effect of the power substation project can find out the problems of the project more comprehensively,which has important practical significance for the further development of the p... The evaluation of the implementation effect of the power substation project can find out the problems of the project more comprehensively,which has important practical significance for the further development of the power substation project.To ensure accuracy and real-time evaluation,this paper proposes a novel hybrid intelligent evaluation and prediction model based on improved TOPSIS and Long Short-Term Memory(LSTM)optimized by a Sperm Whale Algorithm(SWA).Firstly,under the background of considering the development of new energy,the influencing factors of power substation project implementation effect are analyzed from three aspects of technology,economy and society.Moreover,an evaluation model based on improved TOPSIS is constructed.Then,an intelligent prediction model based on SWA optimized LSTM is designed.Finally,the scientificity and accuracy of the proposed model are verified by empirical analysis,and the important factors affecting the implementation effect of power substation projects are pointed out. 展开更多
关键词 New energy substation implementation effect evaluation and intelligent prediction improved topsis LSTM SWA
下载PDF
An Algorithm for Optimal Firewall Placement in IEC61850 Substations 被引量:3
14
作者 Hermes Eslava Luis Alejandro Rojas Danny Pineda 《Journal of Power and Energy Engineering》 2015年第4期16-22,共7页
Recently, most electric power substations have adopted production control systems, such as SCADA systems, which communicate with field devices and remotely control processes from a computer screen. However, these syst... Recently, most electric power substations have adopted production control systems, such as SCADA systems, which communicate with field devices and remotely control processes from a computer screen. However, these systems together with protection measures and additional control actions (using protocol IEC61850) seem not to be enough to free substations of security attacks (e.g. virus, intruders, forgery or unauthorized data manipulation). This paper analyzes the main features of an electric power substation together with the aspects that might be significantly affected by cyber-attacks. The paper also presents the implementation of a specific security system (i.e. firewall-wise system) intended to protect a target distribution network. 展开更多
关键词 FIREWALL SECURITY substationS ELECTRIC Power IEC61850
下载PDF
Implementation of Embedded Ethernet Based on Hardware Protocol Stack in Substation Automation System 被引量:1
15
作者 马强 赵建国 刘炳旭 《Transactions of Tianjin University》 EI CAS 2008年第2期153-156,共4页
Embedded Ethernet technology has been utilized increasingly widely as the communication mode in the substation automation system(SAS).This paper introduces the current applying situation about embedded Ethernet in SAS... Embedded Ethernet technology has been utilized increasingly widely as the communication mode in the substation automation system(SAS).This paper introduces the current applying situation about embedded Ethernet in SAS First.After analyzing the protocol levels used in SAS based on embedded Ethernet and the differences between the TCP and UDP,UDP/IP is selected as the communication protocol between the station-level and bay-level devices for its real-time characteristic.Then a new kind of implementation of the embedded Ethernet is presented based on hardware protocol stack.The designed scheme can be implemented easily,reduce cost significantly and shorten developing cycle. 展开更多
关键词 embedded Ethernet substation automation system hardware protocol stack UDP W3100A
下载PDF
Research on Distribution of Electromagnetic Environment around Substations and Optimization Layout of On-line Monitoring 被引量:1
16
作者 Li Peiming Xiao Jun Wang Wenjin 《Meteorological and Environmental Research》 CAS 2019年第6期60-63,共4页
The characteristics and distribution law of electromagnetic environment around substations with different levels of voltage were studied,and the main influencing factors were discussed. Meanwhile,a scheme for locating... The characteristics and distribution law of electromagnetic environment around substations with different levels of voltage were studied,and the main influencing factors were discussed. Meanwhile,a scheme for locating monitoring points suitable for an on-line monitoring system of electromagnetic environment was proposed. 展开更多
关键词 ON-LINE monitoring ELECTROMAGNETIC environment substation Optimization layout
下载PDF
An Investigation into Substation Grounding and Its Implementation on Gaza Substation 被引量:1
17
作者 Ahmed Hammuda Hassan Nouri Mohammed Saleh Al-Ayoubi 《Energy and Power Engineering》 2011年第5期593-599,共7页
An investigation into the optimal design of a substation grounding system for the transmission substation in Gaza City, Palestine has been carried out. A research into the most influential parameters on the effectiven... An investigation into the optimal design of a substation grounding system for the transmission substation in Gaza City, Palestine has been carried out. A research into the most influential parameters on the effectiveness of the substation grid system has been performed and its results have been incorporated into the Gaza case study. Through modelling and simulating the power station in Gaza while considering some field data, an optimal substation grounding grid has been designed and has shown complete conformance to safety. It is thus considered that such a design will protect personnel in any area of the substation in addition to the installed machinery if the largest possible fault current was to traverse the earth. 展开更多
关键词 GAZA GROUNDING Grid Ground Resistance substation STEP VOLTAGE TOUCH VOLTAGE
下载PDF
Research on the Process Layer and Substation Layer Relay Protection in Smart Substation Relay Protection 被引量:2
18
作者 Kong Haibo Xie Xiaodong +2 位作者 Wang Lingfei Sun Peng Xu Bing 《Journal of Electronic Research and Application》 2018年第1期35-42,共8页
The intelligent substation relay protection facility is a fundamental element in construction of modern power system,based on the principles of flexibility,security and accuracy,and it can be divided into process laye... The intelligent substation relay protection facility is a fundamental element in construction of modern power system,based on the principles of flexibility,security and accuracy,and it can be divided into process layer and substation layer according to specific equipment.The former is suitable for individual sampling of disposable equipment,can be separated from the base station synchronization sampling,with the help of synchronous digital system and ping-pong algorithm to achieve synchronization of the overall sampling,that is to take the distribution protection components,through the separate transmission medium to realize the information transmission;the latter is for variable power plant components centralized backup protection,taking online real-time tuning technique. 展开更多
关键词 lectric POWER system INTELLIGENT substation RELAY PROTECTION
下载PDF
Comparative Study on Substation Shielding Due to Direct Lightning Strokes 被引量:1
19
作者 Ab Halim Abu Bakar Chia Kwang Tan +3 位作者 Alyaa Zainal Abidin Pang Jack Khai Hazlie Mokhlis Hazlee Azil Illias 《Journal of Power and Energy Engineering》 2014年第4期600-611,共12页
Malaysia is one of the many countries that experience high lightning related activities. In fact, according to Malaysian Meteorological Department the Ground Flash Density (GFD) in Malaysia, it is rated at the fifth p... Malaysia is one of the many countries that experience high lightning related activities. In fact, according to Malaysian Meteorological Department the Ground Flash Density (GFD) in Malaysia, it is rated at the fifth place in the ten most lightning cities of the world, with a high keraunic level, which is 240 thunderstorm days per year, and in other words, a Ground Flash Density (GFD) of 48.3 flashes per square kilometer per year. In the power systems, high keraunic level would contribute to high possibility of power interruptions such as disruption, degradation, damage and downtime. These outages would ultimately lead to revenue losses and reduction of network reliability. These lightning related interruptions may be in terms of direct lightning strikes to the lines or to the equipments in the substation. By the use of Mat Lab GUI (Graphic Users Interface), this study presents a simple computer program which uses the electro-geometric model (EGM) for the designing of substation shielding systems. The EGM uses the concept where the protection zone of a lightning system lies within the radius where the upward channel initiates and propagates through the air terminal to meet the downward leader. This interception point is called “the point of discrimination” and is where the downward leader decides its final jump. The distance at which the last jump occurs is known as the striking distance. With the use of the striking distance and the mathematical equations developed by Young, Brown-Whitehead, IEEE-1992 (IEEE T&D Committee Equations) and IEEE-1995 (IEEE Substations Committee Equations). This project aimed to investigate, understand and analyse the substation protection by means of masts and shield wires. The analysis is extended to account for lightning protection provided by single mast to two masts as well as from single shield wire to double shielding wires. The outcomes of these four equations will be compared. 展开更多
关键词 LIGHTNING Electro-Geometric Model Striking DISTANCE substation PROTECTION LIGHTNING PROTECTION MATLAB
下载PDF
Research on Testing Technologies of Network System in Smart Substations 被引量:2
20
作者 Zhang Xiaofei Wang Jiesong +2 位作者 Zhang Daoyin Zhang Zhiming Zhao Ruying 《Electricity》 2012年第3期19-23,共5页
The network structures of smart substations and the characteristics of industrial Ethernet switches are analyzed.The testing technologies of network systems based on smart substations are specifically elaborated.A vie... The network structures of smart substations and the characteristics of industrial Ethernet switches are analyzed.The testing technologies of network systems based on smart substations are specifically elaborated.A viewpoint is proposed that special testing policy&method of smart substation networks should be followed,so that the results can reveal the real network data exchange performance of the whole station.This view ensures the safety and stability of smart substations and lays a foundation for future upgrades and expansions. 展开更多
关键词 smart substation industrial Ethernet SWITCH network testing system testing
下载PDF
上一页 1 2 9 下一页 到第
使用帮助 返回顶部