Introduction: 68Ga-PSMA-11 is considered the gold standard in detection of micro and oligometastases in advanced prostate cancer, being used for therapeutic planning, as well as, potentially, for evaluating response t...Introduction: 68Ga-PSMA-11 is considered the gold standard in detection of micro and oligometastases in advanced prostate cancer, being used for therapeutic planning, as well as, potentially, for evaluating response to treatment. The development of ready-to-use lyophilized kit of PSMA-11 adds quality and safety to the routine use of this radiopharmaceutical and represents a pharmacotechnical challenge as it must preserve the integrity and specificity of the ligand. Methods: PSMA-11 kit formulation was proposed, considering radiolabeling parameters and the preservation of the peptide during the lyophilization process, using mannitol as an excipient. Critical temperature characterization studies were carried out using DSC equipment and the freeze-drying process was developed. The direct radiolabeling conditions were evaluated and standardized using 68Ge/68Ga generator eluate from two different manufacturers (ITG and Eckert & Ziegler). The radiochemical purity was evaluated by TLC and HPLC. Biological evaluation was carried out with lyophilized PSMA-11 to demonstrate the integrity of the peptide and preservation of biological activity after the lyophilization process. Results: Based on critical temperature characterization studies, the freeze-drying cycle was designed to reach a freezing temperature of around −40˚C and primary drying at 2˚C. Using 20 mg of mannitol, an intact and elegant lyophilized cake was obtained. PSMA-11 lyophilized kit was directly labeled with 68Ga eluate from 68Ge/68Ga GMP generators (ITG and Eckert & Ziegler) resulting in % RP > 95% at pH 4.0 to 4.5. The results obtained from in vitro and in vivo biological competition studies confirmed the preservation of PSMA-11 affinity for the receptor after lyophilization. Conclusion: A lyophilized formulation (Kit) of PSMA-11 was successfully obtained, which preserved the integrity and biological activity of the peptide and guaranteed radiolabeling efficiency.展开更多
Background: Vaginal discharge is one of most common and nagging problems that women face. About 20% - 25% of women who visit gynecology department complain of vaginal discharge and leucorrhoea. An orally administered ...Background: Vaginal discharge is one of most common and nagging problems that women face. About 20% - 25% of women who visit gynecology department complain of vaginal discharge and leucorrhoea. An orally administered combination kit, containing 2 g secnidazole, 1 g azithromycin and 150 mg fluconazole (Azimyn FS Kit), has been successfully evaluated in clinical trials and used in several countries for management syndromic vaginal discharge due to infections. Methods: This is a longitudinal study which aimed to verify the clinical efficacy of the combined oral kit containing secnidazole, azithromycin and fluconazole (Azimyn FS Kit<sup><sup>®</sup></sup>) in the syndromic treatment of abnormal vaginal discharge in patients received in outpatient consultations in Kinshasa/DR Congo from March to September 2023. Results: Majority of patients had whitish vaginal discharge (51.6%) of average abundance (56.2%), accompanied by pruritus in 72.1% of cases, and dyspareunia in 23.5% of cases and hypogastralgia in 40.2% of cases. One week after treatment with the Azimyn FS<sup><sup>®</sup></sup> combined kit, at the greatest majority of patients (97.3%), abnormal vaginal discharge had decreased by more than 50% (84.1%). Two weeks after treatment with the Azimyn FS<sup><sup>®</sup></sup> combined kit, almost all patients (97.3%) no longer had abnormal vaginal discharge which had completely disappeared. Conclusion: A single dose of secnidazole, azithromycin and fluconazole in the form of an oral combi-kit (Azimyn FS Kit) has shown excellent therapeutic effectiveness in the syndromic treatment of abnormal vaginal discharge wherein patients were treated without diagnostic confirmation.展开更多
[Objectives]To fully understand the quality of commercial enzyme inhibition-colorimetric pesticide residue rapid detection kits,so that they can play a greater role in the detection and supervision of agricultural pro...[Objectives]To fully understand the quality of commercial enzyme inhibition-colorimetric pesticide residue rapid detection kits,so that they can play a greater role in the detection and supervision of agricultural products.[Methods]The sensitivity of 28 kinds of pesticides was determined by using the commercially available enzyme inhibition colorimetric rapid detection kit with Hendu brand.[Results]There was a significant difference in the sensitivity of the kit to each pesticide,and the kit was more sensitive to dichlorvos among the 28 pesticides tested.The sensitivity to methyl isosalifos,dimethoate,isocarbophos,fenthion and phorate was poor,and the sensitivity to quinalphos was different between 3.0 and 2.5 mL.[Conclusions]The large difference of the sensitivity of the enzyme inhibition-colorimetric rapid detection kit for pesticide residues to different kits is a reason for the false positive and false negative test results of the kit,which needs to be considered by relevant personnel.展开更多
Background: Urinary Tract Infection (UTI), a prevalent bacterial infection in adults, heavily relies on cytobacteriological examination of urine (CBEU) for diagnosis. However, in resource-limited countries, accessibil...Background: Urinary Tract Infection (UTI), a prevalent bacterial infection in adults, heavily relies on cytobacteriological examination of urine (CBEU) for diagnosis. However, in resource-limited countries, accessibility to CBEU remains hindered by cost and availability. This study aims to assess the utility of the Urinary Dipstick Test (UDT) in diagnosing UTIs among hospitalized patients in the context of limited resources. Methods: A cross-sectional study was conducted from February to May 2019, encompassing hospitalized patients who underwent CBEU at the bacteriology unit of Sour? Sanou University Hospital. UDT and CBEU were concurrently performed, and UDT’s analytical and diagnostic performance was evaluated against CBEU, considered the gold standard. Results: A total of 274 CBEU requests were registered, involving 274 patients (159 males) with a mean age of 45.8 ± 21.3 years (ranging from 1 to 90 years). UTI was confirmed in 90 patients, yielding a frequency of 32.85%. The UTI bacteriological profile was dominated by Enterobacteriaceae (75.23%), primarily Escherichia coli (60.55%). Nitrite and Leukocytes were positive in 54 (19.8%) and 157 (53.6%) of the samples tested. Among patients with confirmed UTI, Nitrite, and Leukocytes were positive in 30 (33%) and 71 (79%) patients respectively. UDT demonstrated variable performance based on nitrite and leukocyte combination: Sensitivity (57%-82%), Specificity (7%-98%), Positive Predictive Value (PPV) (43%-57%), Negative Predictive Value (NPV) (43%-67%). UDT performed slightly better in women (NPV = 88%) and inpatients without urinary catheters (NPV = 75% and PPV = 80%). Conclusion: This study underscores UDT’s potential utility in excluding UTIs among women, younger patients, and inpatients without urinary catheters, albeit with limited confidence. The UDT emerges as a complementary tool for UTI screening, particularly in resource-limited settings.展开更多
[Objective] This study was conducted to find out an approach for determining trimethoprim residues in water. [Method] Trimethoprim antigen was prepared through a series of reactions from trimethoprim hapten which was ...[Objective] This study was conducted to find out an approach for determining trimethoprim residues in water. [Method] Trimethoprim antigen was prepared through a series of reactions from trimethoprim hapten which was generated through the reaction between trimethoprim and maleic anhydride. And trimethoprim monoclonal antibodies were prepared by animal immune, and used to prepare ELISA kit to detect trimethoprim residues in water. Finally, the limit of detection (LED) of the ELISA kit was determined. [Result] The standard curve covered a concentration range of 0-80 μg/L. The LeD of trimethoprim in water using the ELISA kit was 2.34 μg/kg; the IC50 (half maximal inhibitory concentration) was 4.8 μg/L; the recovery rate of added trimethoprim standard ranged from 60.5% to 79.7%; within-and among-batches RSD was less than 10%. The trimethoprim monoclonal antibody was specific, as the cross-reactivity rate of trimethoprim antibody and diaveridine was less than 1%. The stability tests revealed that the ELISA kit was stable after being stored at 4 ℃ for 12 months. [Conclusion] The results will provide references for controlling the abuse of trimethoprim.展开更多
Mixed anhydride(MA)was used to conjugate ractopamine(RAC)to BSA and obtained artificial antigen BSA-RAC identified by UV and SDS-PAGE.Balb/c mice were immunized with BSA-RAC and hybridoma lines that secrete RAC monocl...Mixed anhydride(MA)was used to conjugate ractopamine(RAC)to BSA and obtained artificial antigen BSA-RAC identified by UV and SDS-PAGE.Balb/c mice were immunized with BSA-RAC and hybridoma lines that secrete RAC monoclonal antibody(mAb)were generated with cell fusion.A ciELISA kit for detection of RAC(RAC-Kit)was developed with RAC mAb and its performance were tested.The results indicated that BSA-RAC was successfully synthesized and its conjugation ratio of RAC to BSA was about 24.5∶1.Three hybridoma lines were filtered and the best one was 4D8-3E11,its affinity constant(Ka)was 1.65×1010 L/mol.The limit of detection of RAC-Kit was 0.5 ng/ml and its detection range was 0.5-184 ng/ml.The mean recoveries of RAC spiked in feed were 85.6% and in swine urine were 88.6%.The precision and accuracy of the assay as determined by inter-assay and intra-assay coefficient variation were below 15%.It had 9.4% cross-reactivity(CR%)to dobutamine and little or no CR to other compounds.The validity of RAC-Kit in 4 ℃ was in 180 d.展开更多
文摘Introduction: 68Ga-PSMA-11 is considered the gold standard in detection of micro and oligometastases in advanced prostate cancer, being used for therapeutic planning, as well as, potentially, for evaluating response to treatment. The development of ready-to-use lyophilized kit of PSMA-11 adds quality and safety to the routine use of this radiopharmaceutical and represents a pharmacotechnical challenge as it must preserve the integrity and specificity of the ligand. Methods: PSMA-11 kit formulation was proposed, considering radiolabeling parameters and the preservation of the peptide during the lyophilization process, using mannitol as an excipient. Critical temperature characterization studies were carried out using DSC equipment and the freeze-drying process was developed. The direct radiolabeling conditions were evaluated and standardized using 68Ge/68Ga generator eluate from two different manufacturers (ITG and Eckert & Ziegler). The radiochemical purity was evaluated by TLC and HPLC. Biological evaluation was carried out with lyophilized PSMA-11 to demonstrate the integrity of the peptide and preservation of biological activity after the lyophilization process. Results: Based on critical temperature characterization studies, the freeze-drying cycle was designed to reach a freezing temperature of around −40˚C and primary drying at 2˚C. Using 20 mg of mannitol, an intact and elegant lyophilized cake was obtained. PSMA-11 lyophilized kit was directly labeled with 68Ga eluate from 68Ge/68Ga GMP generators (ITG and Eckert & Ziegler) resulting in % RP > 95% at pH 4.0 to 4.5. The results obtained from in vitro and in vivo biological competition studies confirmed the preservation of PSMA-11 affinity for the receptor after lyophilization. Conclusion: A lyophilized formulation (Kit) of PSMA-11 was successfully obtained, which preserved the integrity and biological activity of the peptide and guaranteed radiolabeling efficiency.
文摘Background: Vaginal discharge is one of most common and nagging problems that women face. About 20% - 25% of women who visit gynecology department complain of vaginal discharge and leucorrhoea. An orally administered combination kit, containing 2 g secnidazole, 1 g azithromycin and 150 mg fluconazole (Azimyn FS Kit), has been successfully evaluated in clinical trials and used in several countries for management syndromic vaginal discharge due to infections. Methods: This is a longitudinal study which aimed to verify the clinical efficacy of the combined oral kit containing secnidazole, azithromycin and fluconazole (Azimyn FS Kit<sup><sup>®</sup></sup>) in the syndromic treatment of abnormal vaginal discharge in patients received in outpatient consultations in Kinshasa/DR Congo from March to September 2023. Results: Majority of patients had whitish vaginal discharge (51.6%) of average abundance (56.2%), accompanied by pruritus in 72.1% of cases, and dyspareunia in 23.5% of cases and hypogastralgia in 40.2% of cases. One week after treatment with the Azimyn FS<sup><sup>®</sup></sup> combined kit, at the greatest majority of patients (97.3%), abnormal vaginal discharge had decreased by more than 50% (84.1%). Two weeks after treatment with the Azimyn FS<sup><sup>®</sup></sup> combined kit, almost all patients (97.3%) no longer had abnormal vaginal discharge which had completely disappeared. Conclusion: A single dose of secnidazole, azithromycin and fluconazole in the form of an oral combi-kit (Azimyn FS Kit) has shown excellent therapeutic effectiveness in the syndromic treatment of abnormal vaginal discharge wherein patients were treated without diagnostic confirmation.
文摘[Objectives]To fully understand the quality of commercial enzyme inhibition-colorimetric pesticide residue rapid detection kits,so that they can play a greater role in the detection and supervision of agricultural products.[Methods]The sensitivity of 28 kinds of pesticides was determined by using the commercially available enzyme inhibition colorimetric rapid detection kit with Hendu brand.[Results]There was a significant difference in the sensitivity of the kit to each pesticide,and the kit was more sensitive to dichlorvos among the 28 pesticides tested.The sensitivity to methyl isosalifos,dimethoate,isocarbophos,fenthion and phorate was poor,and the sensitivity to quinalphos was different between 3.0 and 2.5 mL.[Conclusions]The large difference of the sensitivity of the enzyme inhibition-colorimetric rapid detection kit for pesticide residues to different kits is a reason for the false positive and false negative test results of the kit,which needs to be considered by relevant personnel.
文摘Background: Urinary Tract Infection (UTI), a prevalent bacterial infection in adults, heavily relies on cytobacteriological examination of urine (CBEU) for diagnosis. However, in resource-limited countries, accessibility to CBEU remains hindered by cost and availability. This study aims to assess the utility of the Urinary Dipstick Test (UDT) in diagnosing UTIs among hospitalized patients in the context of limited resources. Methods: A cross-sectional study was conducted from February to May 2019, encompassing hospitalized patients who underwent CBEU at the bacteriology unit of Sour? Sanou University Hospital. UDT and CBEU were concurrently performed, and UDT’s analytical and diagnostic performance was evaluated against CBEU, considered the gold standard. Results: A total of 274 CBEU requests were registered, involving 274 patients (159 males) with a mean age of 45.8 ± 21.3 years (ranging from 1 to 90 years). UTI was confirmed in 90 patients, yielding a frequency of 32.85%. The UTI bacteriological profile was dominated by Enterobacteriaceae (75.23%), primarily Escherichia coli (60.55%). Nitrite and Leukocytes were positive in 54 (19.8%) and 157 (53.6%) of the samples tested. Among patients with confirmed UTI, Nitrite, and Leukocytes were positive in 30 (33%) and 71 (79%) patients respectively. UDT demonstrated variable performance based on nitrite and leukocyte combination: Sensitivity (57%-82%), Specificity (7%-98%), Positive Predictive Value (PPV) (43%-57%), Negative Predictive Value (NPV) (43%-67%). UDT performed slightly better in women (NPV = 88%) and inpatients without urinary catheters (NPV = 75% and PPV = 80%). Conclusion: This study underscores UDT’s potential utility in excluding UTIs among women, younger patients, and inpatients without urinary catheters, albeit with limited confidence. The UDT emerges as a complementary tool for UTI screening, particularly in resource-limited settings.
基金Supported by Beijing Municipal Science and Technology Project(Z151100002115059)~~
文摘[Objective] This study was conducted to find out an approach for determining trimethoprim residues in water. [Method] Trimethoprim antigen was prepared through a series of reactions from trimethoprim hapten which was generated through the reaction between trimethoprim and maleic anhydride. And trimethoprim monoclonal antibodies were prepared by animal immune, and used to prepare ELISA kit to detect trimethoprim residues in water. Finally, the limit of detection (LED) of the ELISA kit was determined. [Result] The standard curve covered a concentration range of 0-80 μg/L. The LeD of trimethoprim in water using the ELISA kit was 2.34 μg/kg; the IC50 (half maximal inhibitory concentration) was 4.8 μg/L; the recovery rate of added trimethoprim standard ranged from 60.5% to 79.7%; within-and among-batches RSD was less than 10%. The trimethoprim monoclonal antibody was specific, as the cross-reactivity rate of trimethoprim antibody and diaveridine was less than 1%. The stability tests revealed that the ELISA kit was stable after being stored at 4 ℃ for 12 months. [Conclusion] The results will provide references for controlling the abuse of trimethoprim.
基金Supported by the Key Project of National Science and Technology Surporting Plan during 11th-Five-Year of China(2006BAK02A21/1)~~
文摘Mixed anhydride(MA)was used to conjugate ractopamine(RAC)to BSA and obtained artificial antigen BSA-RAC identified by UV and SDS-PAGE.Balb/c mice were immunized with BSA-RAC and hybridoma lines that secrete RAC monoclonal antibody(mAb)were generated with cell fusion.A ciELISA kit for detection of RAC(RAC-Kit)was developed with RAC mAb and its performance were tested.The results indicated that BSA-RAC was successfully synthesized and its conjugation ratio of RAC to BSA was about 24.5∶1.Three hybridoma lines were filtered and the best one was 4D8-3E11,its affinity constant(Ka)was 1.65×1010 L/mol.The limit of detection of RAC-Kit was 0.5 ng/ml and its detection range was 0.5-184 ng/ml.The mean recoveries of RAC spiked in feed were 85.6% and in swine urine were 88.6%.The precision and accuracy of the assay as determined by inter-assay and intra-assay coefficient variation were below 15%.It had 9.4% cross-reactivity(CR%)to dobutamine and little or no CR to other compounds.The validity of RAC-Kit in 4 ℃ was in 180 d.