By using the extended Huygens-Fresnel diffraction integral and the method of expanding the aperture function into a finite sum of complex Caussian functions, an approximate analytical formula of the double-distance pr...By using the extended Huygens-Fresnel diffraction integral and the method of expanding the aperture function into a finite sum of complex Caussian functions, an approximate analytical formula of the double-distance propagation for Caussian beam passing through a tilted cat-eye optical lens and going back along the entrance way in a turbulent atmosphere has been derived. Through numerical calculation, the effects of incidence angle, propagation distance, and structure constant on the propagation properties of a Gaussian beam in a turbulent atmosphere are studied. It is found that the incidence angle creates an unsymmetrical average intensity distribution pattern, while the propagation distance and the structure constant can each create a smooth and symmetrical average intensity distribution pattern. The average intensity peak gradually deviates from the centre, and the central average intensity value decreases quickly with the increase in incidence angle, while a larger structure constant can bring the average intensity peak back to the centre.展开更多
For a compact millimeter wave imaging system it is very important to design every component into small size, for the components in a millimeter wave system are usually much larger than those in an optical imaging syst...For a compact millimeter wave imaging system it is very important to design every component into small size, for the components in a millimeter wave system are usually much larger than those in an optical imaging system due to rela-tively long wave lengths. In this paper, we suggest a kind of binary diffractive lens (BDL) designed using double nega-tive materials (DNG) as the objective lens for a millimeter wave imaging system. The DNG-BDL has not only the ad-vantage of low profile but also small f number, which will be benefit for constructing a compact millimeter wave imaging system. Several DNG-BDL are designed and analyzed using the FDTD method. The numerical results of the focal plane field of the DNG-BDL are presented, which show that the DNG-BDL with small f number has relatively better focusing characteristic than that of a double positive BDL with same f number.展开更多
A new type of double function optical circulator for double fibers is proposed in this paper. Two fiber tips and lens twice are employed in this kind of device as the coupling system for what is believed to be the fir...A new type of double function optical circulator for double fibers is proposed in this paper. Two fiber tips and lens twice are employed in this kind of device as the coupling system for what is believed to be the first time. Because two fiber tips and lens twice are used, the function of optical circulator is duplicated in comparison with conventional optical circulator with single fiber tip. Thus the optical circulator has a low cost and a small volume comparatively. Excess loss of the coupling system and the misalignment of the lens twice in angular error and the position error to the developed circulator are analyzed and discussed by using Gauss wave and double integral in theory. The analysis results show that the excess loss is zero when each distance is equal to f between every adjacent: fraction and without misalignment error in the coupling system. In addition, the excess loss is increasing with increment of the distance error and the angular error. The errors of the angular of the optical axis to lens and the distance between the SL to lens are the main source of the excess loss. The higher the errors are, the higher the excess loss is. It's very important for reducing the misalignment errors in the coupling system with high ratio of coupling to achieve low excess loss. Details of design and excess loss in the coupling system of this circulator are presented.展开更多
基金supported by the National Defense Pre-research Foundation of China (Grant No. TY7131008)
文摘By using the extended Huygens-Fresnel diffraction integral and the method of expanding the aperture function into a finite sum of complex Caussian functions, an approximate analytical formula of the double-distance propagation for Caussian beam passing through a tilted cat-eye optical lens and going back along the entrance way in a turbulent atmosphere has been derived. Through numerical calculation, the effects of incidence angle, propagation distance, and structure constant on the propagation properties of a Gaussian beam in a turbulent atmosphere are studied. It is found that the incidence angle creates an unsymmetrical average intensity distribution pattern, while the propagation distance and the structure constant can each create a smooth and symmetrical average intensity distribution pattern. The average intensity peak gradually deviates from the centre, and the central average intensity value decreases quickly with the increase in incidence angle, while a larger structure constant can bring the average intensity peak back to the centre.
文摘For a compact millimeter wave imaging system it is very important to design every component into small size, for the components in a millimeter wave system are usually much larger than those in an optical imaging system due to rela-tively long wave lengths. In this paper, we suggest a kind of binary diffractive lens (BDL) designed using double nega-tive materials (DNG) as the objective lens for a millimeter wave imaging system. The DNG-BDL has not only the ad-vantage of low profile but also small f number, which will be benefit for constructing a compact millimeter wave imaging system. Several DNG-BDL are designed and analyzed using the FDTD method. The numerical results of the focal plane field of the DNG-BDL are presented, which show that the DNG-BDL with small f number has relatively better focusing characteristic than that of a double positive BDL with same f number.
文摘A new type of double function optical circulator for double fibers is proposed in this paper. Two fiber tips and lens twice are employed in this kind of device as the coupling system for what is believed to be the first time. Because two fiber tips and lens twice are used, the function of optical circulator is duplicated in comparison with conventional optical circulator with single fiber tip. Thus the optical circulator has a low cost and a small volume comparatively. Excess loss of the coupling system and the misalignment of the lens twice in angular error and the position error to the developed circulator are analyzed and discussed by using Gauss wave and double integral in theory. The analysis results show that the excess loss is zero when each distance is equal to f between every adjacent: fraction and without misalignment error in the coupling system. In addition, the excess loss is increasing with increment of the distance error and the angular error. The errors of the angular of the optical axis to lens and the distance between the SL to lens are the main source of the excess loss. The higher the errors are, the higher the excess loss is. It's very important for reducing the misalignment errors in the coupling system with high ratio of coupling to achieve low excess loss. Details of design and excess loss in the coupling system of this circulator are presented.