The present study examined the temporal responses and the efficacy of 192Ir HDR endovascular irradiation for preventing smooth muscle cell proliferation of rabbit iliac arteries after PTA with a cutting balloon cathe...The present study examined the temporal responses and the efficacy of 192Ir HDR endovascular irradiation for preventing smooth muscle cell proliferation of rabbit iliac arteries after PTA with a cutting balloon catheter. Endovascular irradiation with 12 Gy was randomly performed on the one side of iliac arterial segment with the unirradiated side serving as a control. Animals were euthanatized 1, 2, 3, 4, 8 and 12 week(s) after angioplasty. Histopathological and immunohistochemical studies were carried out. Histopathology showed repair of the dissection by cellular accumulation and a striking reduction in the amount of neointimal hyperplasia in the irradiated arteries as compared with control vessels. A peak of PCNA positive ratio was in neointima of the control arterial segments at a week. 2 - 4 weeks after irradiation, the neointimal PCNA positive ratio was still significantly increased in the control arterial segments compared with the irradiated arterial segments. After 8 weeks, PCNA positive ratio was below 1 % in both irradiated arterial segments and the control. Our results showed that the 192Ir HDR afterloading irradiation with a dose of 12 Gy can be considered sufficient for inhibiting neointimal hyperplasia in angioplastized rabbit iliac arteries with cutting balloon catheter.展开更多
文摘The present study examined the temporal responses and the efficacy of 192Ir HDR endovascular irradiation for preventing smooth muscle cell proliferation of rabbit iliac arteries after PTA with a cutting balloon catheter. Endovascular irradiation with 12 Gy was randomly performed on the one side of iliac arterial segment with the unirradiated side serving as a control. Animals were euthanatized 1, 2, 3, 4, 8 and 12 week(s) after angioplasty. Histopathological and immunohistochemical studies were carried out. Histopathology showed repair of the dissection by cellular accumulation and a striking reduction in the amount of neointimal hyperplasia in the irradiated arteries as compared with control vessels. A peak of PCNA positive ratio was in neointima of the control arterial segments at a week. 2 - 4 weeks after irradiation, the neointimal PCNA positive ratio was still significantly increased in the control arterial segments compared with the irradiated arterial segments. After 8 weeks, PCNA positive ratio was below 1 % in both irradiated arterial segments and the control. Our results showed that the 192Ir HDR afterloading irradiation with a dose of 12 Gy can be considered sufficient for inhibiting neointimal hyperplasia in angioplastized rabbit iliac arteries with cutting balloon catheter.