A Study on the Surface Structures of Viscose-based Activated Carbon Fiber by FT-IR Spectroscopy and XPS 被引量:7
1
作者 黄强 黄永秋 潘鼎 《Journal of Donghua University(English Edition)》 EI CAS 2004年第1期57-62,共6页
Using viscose fiber (VF) as starting material and common steam as activating agent, formation of oxygen structures in activated carbon fiber is investigated. In the preparation of samples, VF was first heated at tempe... Using viscose fiber (VF) as starting material and common steam as activating agent, formation of oxygen structures in activated carbon fiber is investigated. In the preparation of samples, VF was first heated at temperatures between 450℃ and 900℃ in N_2 artmosphere. Then, in a successive activation stage, the product carbonized at 600℃ was activated in steam at 450-900℃ for 30 min, and at 600℃ for 5-30 min. The other carbonization products were activated at 600 and 900℃ for 30 min respectively. The products activated at 900℃ were then activated at 450℃ for 30 min again. The starting materiah carbonized products and all activation products were examined by FT-IR spectroscopy and some products were examined by X-ray photoelectron spectroscope (XPS). And the yields of the carbonized and activated products were calculated. By analysing these spectra, the amount of oxygen-containing functional groups of the activated products attained under various activation time, various activation temperature and various previous carbonization temperature was determined. 展开更多
关键词 viscose fiber (VF) activated carbon fiber heat treatment ft-ir spectroscopy XPS
下载PDF
In situ FT-IR spectroscopy investigations of carbon nanotubes supported Co-Mo catalysts for selective hydrodesulfurization of FCC gasoline 被引量:3
2
作者 Jingcheng Zhang Wenkun Yin Hongyan Shang Chenguang Liu 《Journal of Natural Gas Chemistry》 EI CAS CSCD 2008年第2期165-170,共6页
To better understand the nature of carbon nanotubes supported Co-Mo catalysts (Co-Mo/CNTs) for selective hydrodesulfurization (HDS) of fluid catalytic cracking (FCC) gasoline, studies are carried out using in si... To better understand the nature of carbon nanotubes supported Co-Mo catalysts (Co-Mo/CNTs) for selective hydrodesulfurization (HDS) of fluid catalytic cracking (FCC) gasoline, studies are carried out using in situ Fourier transform infrared spectroscopy (FT-IR). The catalytic performances of Co-Mo/CNTs catalysts were evaluated with a mixture of cyclohexane, diisobutylene, cyclohexene, 1-octene (60 : 30 : 5 : 5, volume ratio) and thiophene (0.5%, ratio of total weight) as model compounds to simulate FCC gasoline. The HDS experimental results suggested that the HDS activity and selectivity of Co-Mo/CNTs catalysts were affected by Co/Mo ratio; the optimal Co/Mo atomic ratio is about 0.4, and the optimum reaction temperature is 260 ℃. The in situ FT-IR studies revealed that 1-octene can be completely saturated at 200 ℃. In the FT-IR spectra of diisobutylene, the characteristic absorption peak around 3081 cm^-1 for the stretching vibration peak of =C-H bond was still clear at 320 ℃ indicating that diisobutylene is difficult to be hydrogenated. As for the thiophene, no characteristic absorption peak could be found around 3092 cm^-1 and 835 cm^-1 when the reaction temperature was raised to 280 ℃, indicating that thiophene had been completely hydrodesulfurized. On the basis of FT-IR results, it can be deduced that thiophene HDS reaction occurred mainly through direct hydrogenolysis route, whereas thiophene HDS and diisobutylene hydrogenation reaction over Co-Mo/CNTs catalysts might occur on two different kinds of active sites. 展开更多
关键词 in situ ft-ir HYDRODESULFURIZATION carbon nanotubes HYDROGENOLYSIS THIOPHENE FCC gasoline
下载PDF
FT-IR Spectroscopy Applied for Surface Clays Characterization 被引量:2
3
作者 Paul Djomgoue Daniel Njopwouo 《Journal of Surface Engineered Materials and Advanced Technology》 2013年第4期275-282,共8页
The present paper should be considered as a review of the application of Fourier Transform Infra-Red for surface clay characterization. The application of surface clay materials for water treatment, oil adsorption, ex... The present paper should be considered as a review of the application of Fourier Transform Infra-Red for surface clay characterization. The application of surface clay materials for water treatment, oil adsorption, excipients or as active in drugs has largely increased these recent years. The surface clay material presents hydroxyl groups, which can link very easily water molecules. These hydroxyl groups can react with organic groups and by their vibration in the infra-red region, FT-IR can be easily used as a technical method for surface clay characterization. In this paper, we focus on the determination of Lewis and Bronsted acid sites on the clay surface, a critical review of the sample preparation, the surface characterization of bulk clay and the modified surface clay samples using FT-IR spectroscopy. 展开更多
关键词 CLAY Materials SURFACE Clays HYDROXYLS SURFACE ACIDITY IR spectroscopy
下载PDF
Comparison between Two FT-IR Spectroscopy Analytical Procedures for Micrograms Determination of Asbestos Species in Bulk Materials 被引量:1
4
作者 Luca De Stefano Raffaele Cioffi Francesco Colangelo 《American Journal of Analytical Chemistry》 2012年第1期1-5,共5页
The Fourier Transform Infrared (FT-IR) spectroscopy is by far known to be a useful technique for qualitative and quantitative analysis of asbestos in bulk samples, since all asbestos species exhibit intense absorption... The Fourier Transform Infrared (FT-IR) spectroscopy is by far known to be a useful technique for qualitative and quantitative analysis of asbestos in bulk samples, since all asbestos species exhibit intense absorption peaks in the 4000 - 400 cm-1 region of the infrared spectrum. In the present work, we compare the accuracy and precision of two analytical procedures (the Linear Calibration Curve Method and the Method of Addition) for the quantitative determination of asbestos in a host matrix. We have found that, providing careful samples preparation, both techniques quantify the asbestos content at the level of few micrograms with good precision. Due to less expensive equipment requirements and shorter analysis time, FT-IR can be a competitive analytical technique in the characterization of asbestos containing material with the respect to diffractometry or electron microscopy. 展开更多
关键词 Asbestos CONTAINING Materials QUANTITATIVE METHODS INFRARED spectroscopy
下载PDF
Probing into Surface Sites of Fresh Mo_2N/Al_2O_3,Mo_2C/Al_2O_3 and MoP/Al_2O_3 Catalysts by CO Adsorption and In Situ FT-IR Spectroscopy 被引量:1
5
作者 Zhang Jing Wu Weicheng +1 位作者 Yan Song Zhang Dan 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2010年第4期43-45,共3页
The surface nature of fresh Mo2N/Al2O3, Mo2C/Al2O3 and/MoP/Al2O3 catalysts, which were synthesized directly in the IR cell to avoid passivation, were characterized by in situ IR spectroscopy with CO as a probe molecul... The surface nature of fresh Mo2N/Al2O3, Mo2C/Al2O3 and/MoP/Al2O3 catalysts, which were synthesized directly in the IR cell to avoid passivation, were characterized by in situ IR spectroscopy with CO as a probe molecule. CO adsorbed on fresh catalysts showed characteristic IR bands at 2045 cm-1 for Mo2N/Al2O3 catalyst, 2054 cm-1 for MozC/Al2O3 catalyst and 2037 cm-1 for MoP/Al2O3 catalyst, respectively. A strong band at 2200 cm-1 for Mo2N/Al2O3 catalyst, which could be ascribed to NCO species formed when CO reacted upon surface active nitrogen atoms, and a weak band at 2196 cm-1 for Mo2C/Al2O3 catalyst, which could be attributed to CCO species, were also detected. CO adsorbed on fresh Mo2N/Al2O3 catalyst, Mo2C/Al2O3 catalyst and MoP/Al2O3 catalyst, showed strong molecular adsorption, just like noble metals. Our experimental results are bolstered by direct IR evidence demonstrating the similarity in surface electronic property between the fresh Mo2N/Al2O3, Mo2C/Al2O3 and MoP/Al2O3 catalysts and noble metals. 展开更多
关键词 Mo2C/Al2O3 catalyst Mo2N/Al2O3 catalyst Mo2P/Al2O3 catalyst ft-ir CO
下载PDF
Determination of Shallow Impurity Concentration in Detector-grade Silicon by FT-IR Spectroscopy at 4.2K
6
作者 Zhang, Jichang Wu, Jiangen +4 位作者 Qu, Fengyuan Ye, Hongjuan Xiao, Jincai Yu, Zhiyi Lu, Wei 《Rare Metals》 SCIE EI CAS CSCD 1989年第4期54-58,共5页
A Nicolet-200SXV FT-IR spectrometer combined with an exciting light set-up has been applied to determine the shallow impurity concentration in detector-grade silicon. The detection sensitivity of boron concentration i... A Nicolet-200SXV FT-IR spectrometer combined with an exciting light set-up has been applied to determine the shallow impurity concentration in detector-grade silicon. The detection sensitivity of boron concentration is high up to 7.8 × 10-12. The calibration curve of boron concentration in high-purity silicon has been obtained, from which the experimental value of calibration factor of boron concentration in silicon is demonstrated to be 1.15 × 1013 cm-1. 展开更多
关键词 BORON Trace Analysis Radiation Detectors SILICON Spectrometers Infrared Sensitivity spectroscopy Infrared Low Temperature
下载PDF
Investigation of Spontaneous Condensation of an Amino Acid Based Amphiphile on Cast Film by in situ Transmission FT-IR Spectroscopy
7
作者 Hai Yan WANG Yan Mei LI Yi XIAO Yu Fen ZHAO 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第12期1637-1640,共4页
The spontaneous condensation of the amphiphilic N-(O,O-dihexadecyl)phosphorylalanine on the cast film was observed by in situ investigation of transmission infrared spectroscopy The particular orientation and ordere... The spontaneous condensation of the amphiphilic N-(O,O-dihexadecyl)phosphorylalanine on the cast film was observed by in situ investigation of transmission infrared spectroscopy The particular orientation and ordered packing of the monomers within the multilayers of the cast film is concluded to attribute to the spontaneous condensation between the monomers. 展开更多
关键词 AMPHIPHILE cast film condensation ft-ir N-(O O-dihexadecyl)phosphoryl alanine
下载PDF
Laser spectroscopy imaging technique coupled withnanomaterials for cancer diagnosis: A review 被引量:1
8
作者 Zhengying Peng Pengkun Yin +5 位作者 Dan Li Youyuan Chen Kaiqiang Shu Qingwen Fan Yixiang Duan Qingyu Lin 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第1期1-27,共27页
Laser spectroscopic imaging techniques have received tremendous attention in the-eld of cancer diagnosis due to their high sensitivity,high temporal resolution,and short acquisition time.However,the limited tissue pen... Laser spectroscopic imaging techniques have received tremendous attention in the-eld of cancer diagnosis due to their high sensitivity,high temporal resolution,and short acquisition time.However,the limited tissue penetration of the laser is still a challenge for the in vivo diagnosis of deep-seated lesions.Nanomaterials have been universally integrated with spectroscopic imaging techniques for deeper cancer diagnosis in vivo.The components,morphology,and sizes of nanomaterials are delicately designed,which could realize cancer diagnosis in vivo or in situ.Considering the enhanced signal emitting from the nanomaterials,we emphasized their combination with spectroscopic imaging techniques for cancer diagnosis,like the surface-enhanced Raman scattering(SERS),photoacoustic,fluorescence,and laser-induced breakdown spectroscopy(LIBS).Applications ofthe above spectroscopic techniques offer new prospectsfor cancer diagnosis. 展开更多
关键词 Laser spectroscopy tumor imaging tumor diagnosis NANOMATERIALS
下载PDF
Functional near-infrared spectroscopy in non-invasive neuromodulation 被引量:1
9
作者 Congcong Huo Gongcheng Xu +6 位作者 Hui Xie Tiandi Chen Guangjian Shao Jue Wang Wenhao Li Daifa Wang Zengyong Li 《Neural Regeneration Research》 SCIE CAS CSCD 2024年第7期1517-1522,共6页
Non-invasive cerebral neuromodulation technologies are essential for the reorganization of cerebral neural networks,which have been widely applied in the field of central neurological diseases,such as stroke,Parkinson... Non-invasive cerebral neuromodulation technologies are essential for the reorganization of cerebral neural networks,which have been widely applied in the field of central neurological diseases,such as stroke,Parkinson’s disease,and mental disorders.Although significant advances have been made in neuromodulation technologies,the identification of optimal neurostimulation paramete rs including the co rtical target,duration,and inhibition or excitation pattern is still limited due to the lack of guidance for neural circuits.Moreove r,the neural mechanism unde rlying neuromodulation for improved behavioral performance remains poorly understood.Recently,advancements in neuroimaging have provided insight into neuromodulation techniques.Functional near-infrared spectroscopy,as a novel non-invasive optical brain imaging method,can detect brain activity by measuring cerebral hemodynamics with the advantages of portability,high motion tole rance,and anti-electromagnetic interference.Coupling functional near-infra red spectroscopy with neuromodulation technologies offe rs an opportunity to monitor the cortical response,provide realtime feedbac k,and establish a closed-loop strategy integrating evaluation,feedbac k,and intervention for neurostimulation,which provides a theoretical basis for development of individualized precise neuro rehabilitation.We aimed to summarize the advantages of functional near-infra red spectroscopy and provide an ove rview of the current research on functional near-infrared spectroscopy in transcranial magnetic stimulation,transcranial electrical stimulation,neurofeedback,and braincomputer interfaces.Furthermore,the future perspectives and directions for the application of functional near-infrared spectroscopy in neuromodulation are summarized.In conclusion,functional near-infrared spectroscopy combined with neuromodulation may promote the optimization of central pellral reorganization to achieve better functional recovery form central nervous system diseases. 展开更多
关键词 brain-computer interface cerebral neural networks functional near-infrared spectroscopy neural circuit NEUROFEEDBACK neurological diseases NEUROMODULATION non-invasive brain stimulation transcranial electrical stimulation transcranial electrical stimulation
下载PDF
In situ infrared, Raman and X-ray spectroscopy for the mechanistic understanding of hydrogen evolution reaction
10
作者 Andi Haryanto Kyounghoon Jung +1 位作者 Chan Woo Lee Dong-Wan Kim 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第3期632-651,I0014,共21页
Hydrogen production by water reduction reactions has received considerable attention because hydrogen is considered a clean-energy carrier,key for a sustainable energy future.Computational methods have been widely use... Hydrogen production by water reduction reactions has received considerable attention because hydrogen is considered a clean-energy carrier,key for a sustainable energy future.Computational methods have been widely used to study the reaction mechanism of the hydrogen evolution reaction(HER),but the calculation results need to be supported by experimental results and direct evidence to confirm the mechanistic insights.In this review,we discuss the fundamental principles of the in situ spectroscopic strategy and a theoretical model for a mechanistic understanding of the HER.In addition,we investigate recent studies by in situ Fourier transform infrared(FTIR),Raman spectroscopy,and X-ray absorption spectroscopy(XAS) and cover new findings that occur at the catalyst-electrolyte interface during HER.These spectroscopic strategies provide practical ways to elucidate catalyst phase,reaction intermediate,catalyst-electrolyte interface,intermediate binding energy,metal valency state,and coordination environment during HER. 展开更多
关键词 Hydrogen evolution reaction Infrared spectroscopy Raman spectroscopy X-ray absorption spectroscopy Reaction mechanism
下载PDF
Near Infrared Spectroscopy (NIRS) Model-Based Prediction for Protein Content in Cowpea
11
作者 Kavera Biradar Waltram Ravelombola +1 位作者 Aurora Manley Caroline Ruhl 《American Journal of Plant Sciences》 CAS 2024年第3期145-160,共16页
Cowpea (Vigna unguiculata L. Walp) is a multi-purpose legume with high quality protein for human consumption and livestock. The objective of this work was to develop near-infrared spectroscopy (NIRS) prediction models... Cowpea (Vigna unguiculata L. Walp) is a multi-purpose legume with high quality protein for human consumption and livestock. The objective of this work was to develop near-infrared spectroscopy (NIRS) prediction models to estimate protein content in cowpea. A total of 116 cowpea breeding lines with a wide range of protein contents (19.28 % to 32.04%) were selected to build the model using whole seed and ground seed samples. Partial least-squares discriminant analysis (PLS-DA) regression technique with different pre-treatments (derivatives, standard normal variate, and multiplicative scatter correction) were carried out to develop the protein prediction model. Results showed: 1) spectral plots of both the whole seed and ground seed showed higher spectral scatter at higher wavelengths (>1450 nm), 2) data pre-processing affects prediction accuracy for bot whole seed and ground seed samples, 3) prediction using ground seed samples (0.64 R<sup>2</sup> 0.85) is better than the whole seed (0.33 R<sup>2</sup> 0.78), and 4) the data pre-processing second derivative with standard normal variate has the best prediction (R<sup>2</sup>_whole seed = 0.78, R<sup>2</sup>_ground seed = 0.85). The results will be of interest in cowpea breeding programs aimed at improving total seed protein content. 展开更多
关键词 COWPEA GERMPLASM PROTEIN Near-Infrared spectroscopy (NIRS) Partial Least Squares (PLS)
下载PDF
Investigation on Binding between Cations and Amides using UV Raman Spectroscopy
12
作者 Yi-xuan Liu Zhou-bing Wang +3 位作者 Jing-jing Wang Kang-zhen Tian Xin Meng Gui-lin Mao 《Chinese Journal of Chemical Physics》 SCIE EI CAS CSCD 2024年第4期539-544,I0094,共7页
The interaction of proteins with salt ions plays an important role in life activities.We used butyramide as a model molecule to investigate the interaction of protein backbones with cations.The experiment was performe... The interaction of proteins with salt ions plays an important role in life activities.We used butyramide as a model molecule to investigate the interaction of protein backbones with cations.The experiment was performed in an aqueous solution of metal chloride using UV Raman spectroscopy.It was found that well-hydrated metal cations(Ca^(2+),Mg^(2+))tend to bind to C=O in the amide bond,resulting in redistribution of the amide I band peaks.Specifically,the peak intensity ratio of 1655 cm^(-1)to 1610 cm^(-1)increases significantly with increasing concentrations.However,this phenomenon is not obviously observed in NaCl solution.Furthermore,we studied the effect of salt ions on the water structures.The addition of Ca^(2+)and Mg^(2+)is beneficial to the enhancement of the water signal at the 3400 cm^(-1)position,while the Na^(+)at the same concentration is not obvious.The results have shown that the interaction between cations and amides satisfies the following order:Ca^(2+)>Mg^(2+)>Na^(+),which conforms to the Hofmeister series. 展开更多
关键词 UV Raman spectroscopy Butyramide Hofmeister
下载PDF
A dual-route optical emission spectroscopy diagnostic with wide spectral range and high wavelength resolution on HL-2A tokamak
13
作者 陈越 高继昆 +10 位作者 龙婷 聂林 高金明 马尧 黄渊 田文静 刘延民 朱晓东 庄革 钟武律 许敏 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期25-30,共6页
A dual-route optical emission spectroscopy(D-OES)diagnostic is newly developed to monitor the optical emission from the X-point plasma region on the HL-2 A tokamak.This diagnostic is composed of an imaging system,a be... A dual-route optical emission spectroscopy(D-OES)diagnostic is newly developed to monitor the optical emission from the X-point plasma region on the HL-2 A tokamak.This diagnostic is composed of an imaging system,a beam-splitting system for dual-route measurements,fiber bundles,a spectrometer system,and a control and acquisition system.One route is used to obtain wide-spectral-range spectra,and the other route is used to acquire high-wavelengthresolution line shapes.The spectral resolution of the wide-range spectrometers is 0.8 nm with a coverage of 800 nm(@200-1000 nm).The spectral resolution of the high-resolution spectrometer is 0.01 nm with a coverage of 6 nm(@200-660 nm).The spatial resolution of each route of D-OES is about 4 cm with 11 channels.The temporal resolution is 16 ms at maximum in the single-channel mode.Wide-range spectra(containing Balmer series and a Fulcher band)and highly resolved Ha line shapes are obtained by D-OES in the hydrogen glow discharge in the lab.D-OES measurements are carried out in the high-density deuterium experiments of HL-2A.The electron density n_(e)and deuterium temperature T_(D) in the X-point multifaceted asymmetric radiation from the edge(MARFE)region are derived simultaneously by fitting the measured D_(a) shape.The density n_(e)is observed to increase from~8.7×10^(18)m^(-3)to~7.8×10^(19)m^(-3),and the temperature T_(D)drops from~14.4 eV to~2.3 eV after the onset of MARFE in the discharge#38260. 展开更多
关键词 optical emission spectroscopy Balmer series TOKAMAK
下载PDF
Core-level spectroscopy of the photodissociation process of BrCN molecule
14
作者 周坤 王涵 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期176-182,共7页
Fewest-switches surfacing hopping(FSSH) simulations have been performed with the high-level multi-reference electronic structure method to explore the coupled electronic and nuclear dynamics upon photoexcitation of cy... Fewest-switches surfacing hopping(FSSH) simulations have been performed with the high-level multi-reference electronic structure method to explore the coupled electronic and nuclear dynamics upon photoexcitation of cyanogen bromide(BrCN). The potential energy surfaces(PES) of BrCN are charted as functions of the Jacobi coordinates(R, θ). An indepth examination of the FSSH trajectories reveals the temporal dynamics of the molecule and the population changes of the lowest twelve states during BrCN's photodissociation process, which presents a rich tapestry of dynamical information.Furthermore, the carbon K-edge x-ray absorption spectroscopy(XAS) is calculated with multi-reference inner-shell spectral simulations. The rotation of the CN fragment and the elongation of the C–Br bond are found to be the reason for the peak shifting in the XAS. Our findings offer a nuanced interpretation for inner-shell probe investigations of BrCN, setting the stage for a deeper understanding of the photodissociation process of cyanogen halides molecules. 展开更多
关键词 x-ray absorption spectroscopy PHOTODISSOCIATION fewest-switches surface hopping
下载PDF
Negligible normal fluid in superconducting state of heavily overdoped Bi_(2)Sr_(2)CaCu_(2)O_(8+δ) detected by ultra-low temperature angle-resolved photoemission spectroscopy
15
作者 殷超辉 汪清泓 +23 位作者 解于洋 陈逸雯 刘俊豪 杨鉴刚 贾俊杰 张杏 吕文凯 闫宏涛 戎洪涛 张申金 王志敏 宗楠 刘丽娟 李如康 王晓洋 张丰丰 杨峰 彭钦军 许祖彦 刘国东 毛寒青 赵林 李昕彤 周兴江 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第7期562-567,共6页
In high temperature cuprate superconductors,it was found that the superfluid density decreases with the increase of hole doping.One natural question is whether there exists normal fluid in the superconducting state in... In high temperature cuprate superconductors,it was found that the superfluid density decreases with the increase of hole doping.One natural question is whether there exists normal fluid in the superconducting state in the overdoped region.In this paper,we have carried out high-resolution ultra-low temperature laser-based angle-resolved photoemission measurements on a heavily overdoped Bi2212 sample with a T_(c) of 48 K.We find that this heavily overdoped Bi2212 remains in the strong coupling regime with 2Δ_(0)/(k_(B)T_(c))=5.8.The single-particle scattering rate is very small along the nodal direction(~5 meV) and increases as the momentum moves from the nodal to the antinodal regions.A hard superconducting gap opening is observed near the antinodal region with the spectral weight at the Fermi level fully suppressed to zero.The normal fluid is found to be negligibly small in the superconducting state of this heavily overdoped Bi2212.These results provide key information to understand the high T_(c) mechanism in the cuprate superconductors. 展开更多
关键词 cuprate superconductor angle-resolved photoemission spectroscopy electronic structure
下载PDF
Estimating the yield stress of soft materials via laser-induced breakdown spectroscopy
16
作者 龚书航 李亚举 +7 位作者 钱东斌 叶晋瑞 赵扣 曾强 陈良文 张少锋 杨磊 马新文 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期428-432,共5页
Taking three typical soft samples prepared respectively by loose packings of 77-,95-,and 109-μm copper grains as examples,we perform an experiment to investigate the energy-dependent laser-induced breakdown spectrosc... Taking three typical soft samples prepared respectively by loose packings of 77-,95-,and 109-μm copper grains as examples,we perform an experiment to investigate the energy-dependent laser-induced breakdown spectroscopy(LIBS)of soft materials.We discovered a reversal phenomenon in the trend of energy dependence of plasma emission intensity:increasing initially and then decreasing separated by a well-defined critical energy.The trend reversal is attributed to the laser-induced recoil pressure at the critical energy just matching the sample's yield strength.As a result,a one-to-one correspondence can be well established between the samples'yield stress and the critical energy that is easily obtainable from LIBS measurements.This allows us to propose an innovative method for estimating the yield stress of soft materials via LIBS with attractive advantages including in-situ remote detection,real-time data collection,and minimal destructive to sample. 展开更多
关键词 laser-induced breakdown spectroscopy soft materials yield stress
下载PDF
Research on batch multielement rapid quantitative analysis based on the standard curve-assisted calibration-free laserinduced breakdown spectroscopy method
17
作者 Weiwei HAN Duixiong SUN +7 位作者 Guoding ZHANG Honglin WANG Kai GUO Yuzhuo ZHANG Haoliang WANG Denghong ZHANG Chenzhong DONG Maogen SU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第9期156-164,共9页
This study proposes a batch rapid quantitative analysis method for multiple elements by combining the advantages of standard curve(SC)and calibration-free laser-induced breakdown spectroscopy(CF-LIBS)technology to ach... This study proposes a batch rapid quantitative analysis method for multiple elements by combining the advantages of standard curve(SC)and calibration-free laser-induced breakdown spectroscopy(CF-LIBS)technology to achieve synchronous,rapid,and accurate measurement of elements in a large number of samples,namely,SC-assisted CF-LIBS.Al alloy standard samples,divided into calibration and test samples,were applied to validate the proposed method.SC was built based on the characteristic line of Pb and Cr in the calibration sample,and the contents of Pb and Cr in the test sample were calculated with relative errors of 6%and 4%,respectively.SC built using Cr with multiple characteristic lines yielded better calculation results.The relative contents of ten elements in the test sample were calculated using CF-LIBS.Subsequently,the SC-assisted CF-LIBS was executed,with the majority of the calculation relative errors falling within the range of 2%-5%.Finally,the Al and Na contents of the Al alloy were predicted.The results demonstrate that it effectively enables the rapid and accurate quantitative analysis of multiple elements after a single-element SC analysis of the tested samples.Furthermore,this quantitative analysis method was successfully applied to soil and Astragalus samples,realizing an accurate calculation of the contents of multiple elements.Thus,it is important to advance the LIBS quantitative analysis and its related applications. 展开更多
关键词 laser-induced breakdown spectroscopy standard curve quantitative analysis multielement
下载PDF
Wavelength calibration and spectral analysis of vacuum ultraviolet spectroscopy in EAST
18
作者 计华健 张洪明 +6 位作者 吕波 Cheonho BAE 何梁 林子超 尹相辉 沈永才 戴舒宇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期37-43,共7页
A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength c... A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength calibration for the VUV spectroscopy is achieved utilizing a zinc lamp.The grating angle and charge-coupled device(CCD)position are carefully calibrated for different wavelength positions.The wavelength calibration of the VUV spectroscopy is crucial for improving the accuracy of impurity spectral data,and is required to identify more impurity spectral lines for impurity transport research.Impurity spectra of EAST plasmas have also been obtained in the wavelength range of 50–300 nm with relatively high spectral resolution.It is found that the impurity emissions in the edge region are still dominated by low-Z impurities,such as carbon,oxygen,and nitrogen,albeit with the application of fulltungsten divertors on the EAST tokamak. 展开更多
关键词 vacuum ultraviolet spectroscopy wavelength calibration impurity spectra
下载PDF
Laser-induced breakdown spectroscopy as a method for millimeter-scale inspection of surface flatness
19
作者 Jinrui YE Yaju LI +8 位作者 Zhao ZHANG Xinwei WANG Kewei TAO Qiang ZENG Liangwen CHEN Dongbin QIAN Shaofeng ZHANG Lei YANG Xinwen MA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第9期148-155,共8页
A non-contact method for millimeter-scale inspection of material surface flatness via Laser-Induced Breakdown Spectroscopy(LIBS)is investigated experimentally.The experiment is performed using a planished surface of a... A non-contact method for millimeter-scale inspection of material surface flatness via Laser-Induced Breakdown Spectroscopy(LIBS)is investigated experimentally.The experiment is performed using a planished surface of an alloy steel sample to simulate its various flatness,ranging from 0 to 4.4 mm,by adjusting the laser focal plane to the surface distance with a step length of 0.2 mm.It is found that LIBS measurements are successful in inspecting the flatness differences among these simulated cases,implying that the method investigated here is feasible.It is also found that,for achieving the inspection of surface flatness within such a wide range,when univariate analysis is applied,a piecewise calibration model must be constructed.This is due to the complex dependence of plasma formation conditions on the surface flatness,which inevitably complicates the inspection procedure.To solve the problem,a multivariate analysis with the help of Back-Propagation Neural Network(BPNN)algorithms is applied to further construct the calibration model.By detailed analysis of the model performance,we demonstrate that a unified calibration model can be well established based on BPNN algorithms for unambiguous millimeter-scale range inspection of surface flatness with a resolution of about 0.2 mm. 展开更多
关键词 laser-induced breakdown spectroscopy machine learning surface flatness
下载PDF
Initial measurement of ultrafast charge exchange recombination spectroscopy on the EAST tokamak
20
作者 蒋军 李颖颖 +5 位作者 陈冉 符佳 吕波 余羿 徐国盛 叶民友 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期40-46,共7页
Ultrafast charge exchange recombination spectroscopy(UF-CXRS)has been developed on the EAST tokamak(Yingying Li et al 2019 Fusion Eng.Des.146522)to measure fast evolutions of ion temperature and toroidal velocity.Here... Ultrafast charge exchange recombination spectroscopy(UF-CXRS)has been developed on the EAST tokamak(Yingying Li et al 2019 Fusion Eng.Des.146522)to measure fast evolutions of ion temperature and toroidal velocity.Here,we report the preliminary diagnostic measurements after relative sensitivity calibration.The measurement results show a much higher temporal resolution compared with conventional CXRS,benefiting from the usage of a prismcoupled,high-dispersion volume-phase holographic transmission grating and a high quantum efficiency,high-gain detector array.Utilizing the UF-CXRS diagnostic,the fast evolutions of the ion temperature and rotation velocity during a set of high-frequency small-amplitude edgelocalized modes(ELMs)are obtained on the EAST tokamak,which are then compared with the case of large-amplitude ELMs. 展开更多
关键词 ultrafast charge exchange recombination spectroscopy EAST diagnostic measurements
下载PDF
上一页 1 2 250 下一页 到第