In the oil industry, the productivity of oil wells depends on the performance of the sub-surface equipment system. These systems often have problems stemming from sand, corrosion, internal pressure variation, or other...In the oil industry, the productivity of oil wells depends on the performance of the sub-surface equipment system. These systems often have problems stemming from sand, corrosion, internal pressure variation, or other factors. In order to ensure high equipment performance and avoid high-cost losses, it is essential to identify the source of possible failures in the early stage. However, this requires additional maintenance fees and human power. Moreover, the losses caused by these problems may lead to interruptions in the whole production process. In order to minimize maintenance costs, in this paper, we introduce a model for predicting equipment failure based on processing the historical data collected from multiple sensors. The state of the system is predicted by a Feed-Forward Neural Network (FFNN) with an SGD and Backpropagation algorithm is applied in the training process. Our model’s primary goal is to identify potential malfunctions at an early stage to ensure the production process’ continued high performance. We also evaluated the effectiveness of our model against other solutions currently available in the industry. The results of our study show that the FFNN can attain an accuracy score of 97% on the given dataset, which exceeds the performance of the models provided.展开更多
There are two kinds of unbalance vibrations—force vibration and displacement vibration due to the existence of unbalance excitation in active magnetic bearings(AMB) system. And two unbalance compensation methods—c...There are two kinds of unbalance vibrations—force vibration and displacement vibration due to the existence of unbalance excitation in active magnetic bearings(AMB) system. And two unbalance compensation methods—closed-loop feedback and open loop feed-forward are presented to reduce the force vibration. The transfer function order of the control system directly influencing the system stability will be increased when the closed-loop method is adopted, which makes the real-time compensation not easily achieved. While the open loop method would not increase the primary transfer function order, it provides conditions for real-time compensation. But the real-time compensation signals are not easy to be obtained in the open loop method. To implement real-time force compensation, a new method is proposed to reduce the force vibration caused by the rotor unbalance on the basis of AMB active control. The method realizes real-time and on-line force auto-compensation based on H∞ controller and one novel feed-forward compensation controller, which makes the rotor rotate around its inertia axis. The time-variable feed-forward compensatory signal is provided by a modified adaptive variable step-size least mean square(VSLMS) algorithm. And the relevant least mean square(LMS) algorithm parameters are used to solve the H∞ controller weighting functions. The simulation of the new method to compensate some frequency-variable and sinusoidal signals is completed by MATLAB programming, and real-time compensation is implemented in the actual AMB experimental system. The simulation and experiment results show that the compensation scheme can improve the robust stability and the anti-interference ability of the whole AMB system by using H∞ controller to achieve close-loop control, and then real-time force unbalance compensation is implemented. The proposed research provides a new control strategy containing real-time algorithm and H∞ controller for the force compensation of AMB system. And the stability of the control system is finally improved.展开更多
Since the dead zone phenomenon occurs in electro-hydraulic servo system, the output of the system corresponding to a sinusoidal input contains higher harmonic besides the fundamental input, which causes harmonic disto...Since the dead zone phenomenon occurs in electro-hydraulic servo system, the output of the system corresponding to a sinusoidal input contains higher harmonic besides the fundamental input, which causes harmonic distortion of the output signal. The method for harmonic cancellation based on adaptive filter is proposed. The task is accomplished by generating reference signals with frequency that should be eliminated from the output. The reference inputs are weighted by the adaptive filter in such a way that it closely matches the harmonic. The output of the adaptive filter is a harmonic replica and is injected to the fundamental signal such that the output harmonic is cancelled leaving the desired signal alone, and the total harmonic distortion (THD) is greatly reduced. The weights of filter are adjusted on-line according to the control error by using least-mean-square (LMS) algorithm. Simulation results performed with a hydraulic system demonstrate the efficiency and validity of the proposed adaptive feed-forward compensator (AFC) control scheme展开更多
A dynamic velocity feed-forward compensation (RBF-NN) dynamic model identification was presented for control (DVFCC) approach with RBF neural network the adaptive trajectory tracking of industrial robots. The prop...A dynamic velocity feed-forward compensation (RBF-NN) dynamic model identification was presented for control (DVFCC) approach with RBF neural network the adaptive trajectory tracking of industrial robots. The proposed control approach combined the advantages of traditional feedback closed-loop position control and computed torque control based on inverse dynamic model. The feed-forward compensator used a nominal robot dynamics as accurate dynamic model and on-line identification with RBF-NN as uncertain part to improve dynamic modeling accu- racy. The proposed compensation was applied as velocity feed-forward by an inverse velocity controller that can con- vert torque signal into velocity in the standard industrial controller. Then, the need for a torque control interface was avoided in the real-time dynamic control of industrial robot. The simulations and experiments were carried out on a gas cutting manipulator. The results show that the proposed control approach can reduce steady-state error, suppress overshoot and enhance tracking accuracy and efficiency in joint space and Cartesian space, especially under high- speed condition.展开更多
This paper describes the application of principal component analysis (PCA) and artificial neural network (ANN) to predict the air pollutant index (API) within the seven selected Malaysian air monitoring stations in th...This paper describes the application of principal component analysis (PCA) and artificial neural network (ANN) to predict the air pollutant index (API) within the seven selected Malaysian air monitoring stations in the southern region of Peninsular Malaysia based on seven years database (2005-2011). Feed-forward ANN was used as a prediction method. The feed-forward ANN analysis demonstrated that the rotated principal component scores (RPCs) were the best input parameters to predict API. From the 4 RPCs, only 10 (CO, O3, PM10, NO2, CH4, NmHC, THC, wind direction, humidity and ambient temp) out of 12 prediction variables were the most significant parameters to predict API. The results proved that the ANN method can be applied successfully as tools for decision making and problem solving for better atmospheric management.展开更多
In data stream management systems (DSMSs), how to maintain the quality of queries is a difficult problem because both the processing cost and data arrival rates are highly unpredictable. When the system is overloaded,...In data stream management systems (DSMSs), how to maintain the quality of queries is a difficult problem because both the processing cost and data arrival rates are highly unpredictable. When the system is overloaded, quality degrades significantly and thus load shedding becomes necessary. Unlike processing overloading in the general way which is only by a feedback control (FB) loop to obtain a good and stable performance over data streams, a feedback plus feed-forward control (FFC) strategy is introduced in DSMSs, which have a good quality of service (QoS) in the aspects of miss ratio and processing delay. In this paper, a quality adaptation framework is proposed, in which the control-theory-based techniques are leveraged to adjust the application behavior with the considerations of the current system status. Compared to previous solutions, the FFC strategy achieves a good quality with a waste of fewer resources.展开更多
Feed-forward gene transcriptional regulatory networks, as a set of common signal motifs, are widely distributed in the biological systems. In this paper, the noise characteristics and propagation mechanism of various ...Feed-forward gene transcriptional regulatory networks, as a set of common signal motifs, are widely distributed in the biological systems. In this paper, the noise characteristics and propagation mechanism of various feed-forward gene transcriptional regulatory loops are investigated, including (i) coherent feed-forward loops with AND-gate, (ii) coherent feed-forward loops with OR-gate logic, and (iii) incoherent feed-forward loops with AND-gate logic. By introducing logarithmic gain coefficient and using linear noise approximation, the theoretical formulas of noise decomposition are derived and the theoretical results are verified by Gillespie simulation. From the theoretical and numerical results of noise decomposition algorithm, three general characteristics about noise transmission in these different kinds of feed-forward loops are observed, i) The two-step noise propagation of upstream factor is negative in the incoherent feed-forward loops with AND-gate logic, that is, upstream factor can indirectly suppress the noise of downstream factors, ii) The one-step propagation noise of upstream factor is non-monotonic in the coherent feed-forward loops with OR-gate logic, iii) When the branch of the feed-forward loop is negatively controlled, the total noise of the downstream factor monotonically increases for each of all feed-forward loops. These findings are robust to variations of model parameters. These observations reveal the universal rules of noise propagation in the feed-forward loops, and may contribute to our understanding of design principle of gene circuits.展开更多
In order to improve the steady state performance,dynamic response and power factor of traditional power factor correction(PFC)digital control method and reduce the harmonic distortion of input current,a double closed ...In order to improve the steady state performance,dynamic response and power factor of traditional power factor correction(PFC)digital control method and reduce the harmonic distortion of input current,a double closed loop active power factorcorrection(APFC)control method with feed-forward is proposed.Firstly,the small signal model of Boost PFC control systemis built and the system transfer function is deduced,and then the parameters of the main device with Boost topology is estimated.By means of the feed-forward,the system can quickly respond to the change in input voltage.Furthermore,the use ofvoltage loop and current loop can achieve input current and output voltage regulation Simulink modeling shows that this methodcan effectively control the output voltage in case of input voltage largely fluctuating,improve the system dynamic response abilityand input power factor,and reduce the input current harmonic distortion展开更多
The coagulation bath system of carbon fiber precursor is a complicated and multivariable coupling system. Based on the model of industrial production,the full dynamic decoupling control of the coagulation bath system ...The coagulation bath system of carbon fiber precursor is a complicated and multivariable coupling system. Based on the model of industrial production,the full dynamic decoupling control of the coagulation bath system of carbon fiber precursor is achieved in combination with multivariable feed-forward-like decoupling and proportional-integral-differential( PID) control. Compared with the conventional PID decoupling control,the experiment results show that the proposed method has a better control effect. The use of the controller can achieve complete decoupling of three parameters from coagulation bath system. The method should have great applications.展开更多
A kind of second order algorithm--recursive approximate Newton algorithm was given by Karayiannis. The algorithm was simplified when it was formulated. Especially, the simplification to matrix Hessian was very reluct...A kind of second order algorithm--recursive approximate Newton algorithm was given by Karayiannis. The algorithm was simplified when it was formulated. Especially, the simplification to matrix Hessian was very reluctant, which led to the loss of valuable information and affected performance of the algorithm to certain extent. For multi layer feed forward neural networks, the second order back propagation recursive algorithm based generalized cost criteria was proposed. It is proved that it is equivalent to Newton recursive algorithm and has a second order convergent rate. The performance and application prospect are analyzed. Lots of simulation experiments indicate that the calculation of the new algorithm is almost equivalent to the recursive least square multiple algorithm. The algorithm and selection of networks parameters are significant and the performance is more excellent than BP algorithm and the second order learning algorithm that was given by Karayiannis.展开更多
The harmonic disturbance in the background grid is a problem that must be considered in the design of a gridconnected inverter.However,the full feed-forward method cannot completely suppress the harmonic disturbance i...The harmonic disturbance in the background grid is a problem that must be considered in the design of a gridconnected inverter.However,the full feed-forward method cannot completely suppress the harmonic disturbance in theory and is sensitive to noise.To tackle these problems,a fractional full feed-forward method of grid voltage is proposed in this paper.First,the mathematical model of the full feed-forward method is deduced,and the differences with the theoretical solution,which can suppress all harmonics,are analyzed.Then,the parameter equation,the harmonic suppression performance,stability analysis and the implementation process of this method are given.Compared with the full feed-forward method,the proposed method not only further improves the harmonic suppression performance,but also reduces the order of the mathematical model of the differential term in the feed-forward loop.In addition,the proposed method can be used to flexibly design feed-forward coefficients by selecting the order of suppressed harmonics.Finally,the proposed method is validated by a hardware-in-the-loop experiment on a MT real-time control platform NI PXIE-1071.展开更多
This paper researches the proportional-derivative(PD)feedback control with feed-forward compensations from input for a triangular tethered satellite system(TTSS),and the extended state observer(ESO)design which is fur...This paper researches the proportional-derivative(PD)feedback control with feed-forward compensations from input for a triangular tethered satellite system(TTSS),and the extended state observer(ESO)design which is further incorporated in control to estimate the structural uncertainties in system.By expanding Lagrangian equations under chosen variables,the dynamic equations of TTSS are derived which is the second-order nonlinear equation.Then the feedback control under typical feed-forward compensations is discussed as the nonlinear functions in system are counteracted,and the controlled outputs are computed by deriving the transfer functions of the transformed structures.Moreover,in case of the uncertain structures in system which may constrain the control e®ect,ESO-based PD control is further proposed,and the observed error and controlled accuracy are analyzed by Lyapunov functions.Simulation results on the designed controls are presented to validate the theoretic analyses.展开更多
A 28/56 Gb/s NRZ/PAM-4 dual-mode transceiver(TRx)designed in a 28-nm complementary metal-oxide-semiconduc-tor(CMOS)process is presented in this article.A voltage-mode(VM)driver featuring a 4-tap reconfigurable feed-fo...A 28/56 Gb/s NRZ/PAM-4 dual-mode transceiver(TRx)designed in a 28-nm complementary metal-oxide-semiconduc-tor(CMOS)process is presented in this article.A voltage-mode(VM)driver featuring a 4-tap reconfigurable feed-forward equal-izer(FFE)is employed in the quarter-rate transmitter(TX).The half-rate receiver(RX)incorporates a continuous-time linear equal-izer(CTLE),a 3-stage high-speed slicer with multi-clock-phase sampling,and a clock and data recovery(CDR).The experimen-tal results show that the TRx operates at a maximum speed of 56 Gb/s with chip-on board(COB)assembly.The 28 Gb/s NRZ eye diagram shows a far-end vertical eye opening of 210 mV with an output amplitude of 351 mV single-ended and the 56 Gb/s PAM-4 eye diagram exhibits far-end eye opening of 33 mV(upper-eye),31 mV(mid-eye),and 28 mV(lower-eye)with an output amplitude of 353 mV single-ended.The recovered 14 GHz clock from the RX exhibits random jitter(RJ)of 469 fs and deterministic jitter(DJ)of 8.76 ps.The 875 Mb/s de-multiplexed data features 593 ps horizontal eye opening with 32.02 ps RJ,at bit-error rate(BER)of 10-5(0.53 UI).The power dissipation of TX and RX are 125 and 181.4 mW,respectively,from a 0.9-V sup-ply.展开更多
虚拟同步发电机(virtual synchronous generator,VSG)在引入同步机二阶转子运动方程,增大电力系统等效惯量的同时,也引入了同步发电机的振荡特性,有功低频振荡等动态稳定性问题也随之而来。引入调速侧电力系统稳定器(governor power sys...虚拟同步发电机(virtual synchronous generator,VSG)在引入同步机二阶转子运动方程,增大电力系统等效惯量的同时,也引入了同步发电机的振荡特性,有功低频振荡等动态稳定性问题也随之而来。引入调速侧电力系统稳定器(governor power system stabilizer,GPSS)能有效抑制VSG的功率低频振荡,但其在超调量及调节时间方面的控制效果仍有待提高。通过建立VSG的小信号模型从极点配置角度分析其稳定性,揭示基于GPSS的VSG控制策略在功率动态响应上存在较高超调和较长调节时间的原因。基于此,参考GPSS控制思想,提出了一种基于超前滞后环节附加前馈阻尼补偿的虚拟同步发电机控制策略。并从理论上分析验证了所提控制策略在不影响系统稳态特性的前提下,能够提供调整自由度更高的正阻尼,在有效地抑制功率超调的同时提高了系统的调节速度,从而更好地抑制了有功功率的低频振荡。最后通过MATLAB/Simulink进行对比仿真,仿真结果与理论分析结果一致,证明了所提控制策略的正确性和有效性。展开更多
文摘In the oil industry, the productivity of oil wells depends on the performance of the sub-surface equipment system. These systems often have problems stemming from sand, corrosion, internal pressure variation, or other factors. In order to ensure high equipment performance and avoid high-cost losses, it is essential to identify the source of possible failures in the early stage. However, this requires additional maintenance fees and human power. Moreover, the losses caused by these problems may lead to interruptions in the whole production process. In order to minimize maintenance costs, in this paper, we introduce a model for predicting equipment failure based on processing the historical data collected from multiple sensors. The state of the system is predicted by a Feed-Forward Neural Network (FFNN) with an SGD and Backpropagation algorithm is applied in the training process. Our model’s primary goal is to identify potential malfunctions at an early stage to ensure the production process’ continued high performance. We also evaluated the effectiveness of our model against other solutions currently available in the industry. The results of our study show that the FFNN can attain an accuracy score of 97% on the given dataset, which exceeds the performance of the models provided.
基金supported by National Natural Science Foundation of China(Grant No.50437010)National Hi-tech Research and Development Program of China(863Program,Grant No.2006AA05Z205)Project of Six Talented Peak of Jiangsu Province,China(Grant No.07-D-013)
文摘There are two kinds of unbalance vibrations—force vibration and displacement vibration due to the existence of unbalance excitation in active magnetic bearings(AMB) system. And two unbalance compensation methods—closed-loop feedback and open loop feed-forward are presented to reduce the force vibration. The transfer function order of the control system directly influencing the system stability will be increased when the closed-loop method is adopted, which makes the real-time compensation not easily achieved. While the open loop method would not increase the primary transfer function order, it provides conditions for real-time compensation. But the real-time compensation signals are not easy to be obtained in the open loop method. To implement real-time force compensation, a new method is proposed to reduce the force vibration caused by the rotor unbalance on the basis of AMB active control. The method realizes real-time and on-line force auto-compensation based on H∞ controller and one novel feed-forward compensation controller, which makes the rotor rotate around its inertia axis. The time-variable feed-forward compensatory signal is provided by a modified adaptive variable step-size least mean square(VSLMS) algorithm. And the relevant least mean square(LMS) algorithm parameters are used to solve the H∞ controller weighting functions. The simulation of the new method to compensate some frequency-variable and sinusoidal signals is completed by MATLAB programming, and real-time compensation is implemented in the actual AMB experimental system. The simulation and experiment results show that the compensation scheme can improve the robust stability and the anti-interference ability of the whole AMB system by using H∞ controller to achieve close-loop control, and then real-time force unbalance compensation is implemented. The proposed research provides a new control strategy containing real-time algorithm and H∞ controller for the force compensation of AMB system. And the stability of the control system is finally improved.
文摘Since the dead zone phenomenon occurs in electro-hydraulic servo system, the output of the system corresponding to a sinusoidal input contains higher harmonic besides the fundamental input, which causes harmonic distortion of the output signal. The method for harmonic cancellation based on adaptive filter is proposed. The task is accomplished by generating reference signals with frequency that should be eliminated from the output. The reference inputs are weighted by the adaptive filter in such a way that it closely matches the harmonic. The output of the adaptive filter is a harmonic replica and is injected to the fundamental signal such that the output harmonic is cancelled leaving the desired signal alone, and the total harmonic distortion (THD) is greatly reduced. The weights of filter are adjusted on-line according to the control error by using least-mean-square (LMS) algorithm. Simulation results performed with a hydraulic system demonstrate the efficiency and validity of the proposed adaptive feed-forward compensator (AFC) control scheme
文摘A dynamic velocity feed-forward compensation (RBF-NN) dynamic model identification was presented for control (DVFCC) approach with RBF neural network the adaptive trajectory tracking of industrial robots. The proposed control approach combined the advantages of traditional feedback closed-loop position control and computed torque control based on inverse dynamic model. The feed-forward compensator used a nominal robot dynamics as accurate dynamic model and on-line identification with RBF-NN as uncertain part to improve dynamic modeling accu- racy. The proposed compensation was applied as velocity feed-forward by an inverse velocity controller that can con- vert torque signal into velocity in the standard industrial controller. Then, the need for a torque control interface was avoided in the real-time dynamic control of industrial robot. The simulations and experiments were carried out on a gas cutting manipulator. The results show that the proposed control approach can reduce steady-state error, suppress overshoot and enhance tracking accuracy and efficiency in joint space and Cartesian space, especially under high- speed condition.
文摘This paper describes the application of principal component analysis (PCA) and artificial neural network (ANN) to predict the air pollutant index (API) within the seven selected Malaysian air monitoring stations in the southern region of Peninsular Malaysia based on seven years database (2005-2011). Feed-forward ANN was used as a prediction method. The feed-forward ANN analysis demonstrated that the rotated principal component scores (RPCs) were the best input parameters to predict API. From the 4 RPCs, only 10 (CO, O3, PM10, NO2, CH4, NmHC, THC, wind direction, humidity and ambient temp) out of 12 prediction variables were the most significant parameters to predict API. The results proved that the ANN method can be applied successfully as tools for decision making and problem solving for better atmospheric management.
基金Supported by the National Key R&D Program of China(2016YFC1401900)the National Science Foundation of China(61173029,61672144)
文摘In data stream management systems (DSMSs), how to maintain the quality of queries is a difficult problem because both the processing cost and data arrival rates are highly unpredictable. When the system is overloaded, quality degrades significantly and thus load shedding becomes necessary. Unlike processing overloading in the general way which is only by a feedback control (FB) loop to obtain a good and stable performance over data streams, a feedback plus feed-forward control (FFC) strategy is introduced in DSMSs, which have a good quality of service (QoS) in the aspects of miss ratio and processing delay. In this paper, a quality adaptation framework is proposed, in which the control-theory-based techniques are leveraged to adjust the application behavior with the considerations of the current system status. Compared to previous solutions, the FFC strategy achieves a good quality with a waste of fewer resources.
基金Project supported by the Fundamental Research Funds for the Central Universities,China(Grant Nos.2662015QC041 and 2662014BQ069)the Huazhong Agricultural University Scientific&Technological Self-innovation Foundation,China(Grant No.2015RC021)the National Natural Science Foundation of China(Grant Nos.11675060,91730301,11547244,and 11474117)
文摘Feed-forward gene transcriptional regulatory networks, as a set of common signal motifs, are widely distributed in the biological systems. In this paper, the noise characteristics and propagation mechanism of various feed-forward gene transcriptional regulatory loops are investigated, including (i) coherent feed-forward loops with AND-gate, (ii) coherent feed-forward loops with OR-gate logic, and (iii) incoherent feed-forward loops with AND-gate logic. By introducing logarithmic gain coefficient and using linear noise approximation, the theoretical formulas of noise decomposition are derived and the theoretical results are verified by Gillespie simulation. From the theoretical and numerical results of noise decomposition algorithm, three general characteristics about noise transmission in these different kinds of feed-forward loops are observed, i) The two-step noise propagation of upstream factor is negative in the incoherent feed-forward loops with AND-gate logic, that is, upstream factor can indirectly suppress the noise of downstream factors, ii) The one-step propagation noise of upstream factor is non-monotonic in the coherent feed-forward loops with OR-gate logic, iii) When the branch of the feed-forward loop is negatively controlled, the total noise of the downstream factor monotonically increases for each of all feed-forward loops. These findings are robust to variations of model parameters. These observations reveal the universal rules of noise propagation in the feed-forward loops, and may contribute to our understanding of design principle of gene circuits.
基金National Natural Science Foundation of China(No.61261029)
文摘In order to improve the steady state performance,dynamic response and power factor of traditional power factor correction(PFC)digital control method and reduce the harmonic distortion of input current,a double closed loop active power factorcorrection(APFC)control method with feed-forward is proposed.Firstly,the small signal model of Boost PFC control systemis built and the system transfer function is deduced,and then the parameters of the main device with Boost topology is estimated.By means of the feed-forward,the system can quickly respond to the change in input voltage.Furthermore,the use ofvoltage loop and current loop can achieve input current and output voltage regulation Simulink modeling shows that this methodcan effectively control the output voltage in case of input voltage largely fluctuating,improve the system dynamic response abilityand input power factor,and reduce the input current harmonic distortion
基金the Key Project of the National Nature Science Foundation of China(No.61134009)Program for Changjiang Scholars and Innovation Research Team in University from the Ministry of Education,China(No.IRT1220)+1 种基金Specialized Research Fund for Shanghai Leading Talents,Project of the Shanghai Committee of Science and Technology,China(No.13JC1407500)the Fundamental Research Funds for the Central Universities,China(No.2232012A3-04)
文摘The coagulation bath system of carbon fiber precursor is a complicated and multivariable coupling system. Based on the model of industrial production,the full dynamic decoupling control of the coagulation bath system of carbon fiber precursor is achieved in combination with multivariable feed-forward-like decoupling and proportional-integral-differential( PID) control. Compared with the conventional PID decoupling control,the experiment results show that the proposed method has a better control effect. The use of the controller can achieve complete decoupling of three parameters from coagulation bath system. The method should have great applications.
文摘A kind of second order algorithm--recursive approximate Newton algorithm was given by Karayiannis. The algorithm was simplified when it was formulated. Especially, the simplification to matrix Hessian was very reluctant, which led to the loss of valuable information and affected performance of the algorithm to certain extent. For multi layer feed forward neural networks, the second order back propagation recursive algorithm based generalized cost criteria was proposed. It is proved that it is equivalent to Newton recursive algorithm and has a second order convergent rate. The performance and application prospect are analyzed. Lots of simulation experiments indicate that the calculation of the new algorithm is almost equivalent to the recursive least square multiple algorithm. The algorithm and selection of networks parameters are significant and the performance is more excellent than BP algorithm and the second order learning algorithm that was given by Karayiannis.
基金supported in part by the National Natural Science Foundation of China(61703375).
文摘The harmonic disturbance in the background grid is a problem that must be considered in the design of a gridconnected inverter.However,the full feed-forward method cannot completely suppress the harmonic disturbance in theory and is sensitive to noise.To tackle these problems,a fractional full feed-forward method of grid voltage is proposed in this paper.First,the mathematical model of the full feed-forward method is deduced,and the differences with the theoretical solution,which can suppress all harmonics,are analyzed.Then,the parameter equation,the harmonic suppression performance,stability analysis and the implementation process of this method are given.Compared with the full feed-forward method,the proposed method not only further improves the harmonic suppression performance,but also reduces the order of the mathematical model of the differential term in the feed-forward loop.In addition,the proposed method can be used to flexibly design feed-forward coefficients by selecting the order of suppressed harmonics.Finally,the proposed method is validated by a hardware-in-the-loop experiment on a MT real-time control platform NI PXIE-1071.
基金supported by the National Natural Science Foundation of China under Grant Nos.91848205,62222313,and 62173275.
文摘This paper researches the proportional-derivative(PD)feedback control with feed-forward compensations from input for a triangular tethered satellite system(TTSS),and the extended state observer(ESO)design which is further incorporated in control to estimate the structural uncertainties in system.By expanding Lagrangian equations under chosen variables,the dynamic equations of TTSS are derived which is the second-order nonlinear equation.Then the feedback control under typical feed-forward compensations is discussed as the nonlinear functions in system are counteracted,and the controlled outputs are computed by deriving the transfer functions of the transformed structures.Moreover,in case of the uncertain structures in system which may constrain the control e®ect,ESO-based PD control is further proposed,and the observed error and controlled accuracy are analyzed by Lyapunov functions.Simulation results on the designed controls are presented to validate the theoretic analyses.
基金supported by National Natural Science Foundation of China under Grant 62174132the Fundamental Research Funds for Central Universities under Grant xzy022022060.
文摘A 28/56 Gb/s NRZ/PAM-4 dual-mode transceiver(TRx)designed in a 28-nm complementary metal-oxide-semiconduc-tor(CMOS)process is presented in this article.A voltage-mode(VM)driver featuring a 4-tap reconfigurable feed-forward equal-izer(FFE)is employed in the quarter-rate transmitter(TX).The half-rate receiver(RX)incorporates a continuous-time linear equal-izer(CTLE),a 3-stage high-speed slicer with multi-clock-phase sampling,and a clock and data recovery(CDR).The experimen-tal results show that the TRx operates at a maximum speed of 56 Gb/s with chip-on board(COB)assembly.The 28 Gb/s NRZ eye diagram shows a far-end vertical eye opening of 210 mV with an output amplitude of 351 mV single-ended and the 56 Gb/s PAM-4 eye diagram exhibits far-end eye opening of 33 mV(upper-eye),31 mV(mid-eye),and 28 mV(lower-eye)with an output amplitude of 353 mV single-ended.The recovered 14 GHz clock from the RX exhibits random jitter(RJ)of 469 fs and deterministic jitter(DJ)of 8.76 ps.The 875 Mb/s de-multiplexed data features 593 ps horizontal eye opening with 32.02 ps RJ,at bit-error rate(BER)of 10-5(0.53 UI).The power dissipation of TX and RX are 125 and 181.4 mW,respectively,from a 0.9-V sup-ply.
文摘虚拟同步发电机(virtual synchronous generator,VSG)在引入同步机二阶转子运动方程,增大电力系统等效惯量的同时,也引入了同步发电机的振荡特性,有功低频振荡等动态稳定性问题也随之而来。引入调速侧电力系统稳定器(governor power system stabilizer,GPSS)能有效抑制VSG的功率低频振荡,但其在超调量及调节时间方面的控制效果仍有待提高。通过建立VSG的小信号模型从极点配置角度分析其稳定性,揭示基于GPSS的VSG控制策略在功率动态响应上存在较高超调和较长调节时间的原因。基于此,参考GPSS控制思想,提出了一种基于超前滞后环节附加前馈阻尼补偿的虚拟同步发电机控制策略。并从理论上分析验证了所提控制策略在不影响系统稳态特性的前提下,能够提供调整自由度更高的正阻尼,在有效地抑制功率超调的同时提高了系统的调节速度,从而更好地抑制了有功功率的低频振荡。最后通过MATLAB/Simulink进行对比仿真,仿真结果与理论分析结果一致,证明了所提控制策略的正确性和有效性。