期刊文献+
共找到332,091篇文章
< 1 2 250 >
每页显示 20 50 100
A peak enhancement of frequency response of waveguide integrated silicon-based germanium avalanche photodetector
1
作者 Linkai Yi Daoqun Liu +8 位作者 Wenzheng Cheng Daimo Li Guoqi Zhou Peng Zhang Bo Tang Bin Li Wenwu Wang Yan Yang Zhihua Li 《Journal of Semiconductors》 EI CAS CSCD 2024年第7期61-68,共8页
Avalanche photodetectors(APDs) featuring an avalanche multiplication region are vital for reaching high sensitivity and responsivity in optical transceivers. Waveguide-coupled Ge-on-Si separate absorption, charge, and... Avalanche photodetectors(APDs) featuring an avalanche multiplication region are vital for reaching high sensitivity and responsivity in optical transceivers. Waveguide-coupled Ge-on-Si separate absorption, charge, and multiplication(SACM)APDs are popular due to their straightforward fabrication process, low optical propagation loss, and high detection sensitivity in optical communications. This paper introduces a lateral SACM Ge-on-Si APD on a silicon-on-insulator(SOI) wafer, featuring a 10 μm-long, 0.5 μm-wide Ge layer at 1310 nm on a standard 8-inch silicon photonics platform. The dark current measures approximately 38.6 μA at-21 V, indicating a breakdown voltage greater than-21 V for the device. The APDs exhibit a unitgain responsivity of 0.5 A/W at-10 V. At-15 V, their responsivity reaches 2.98 and 2.91 A/W with input powers of-10 and-25 dBm, respectively. The device's 3-dB bandwidth is 15 GHz with an input power of-15 dBm and a gain is 11.68. Experimental results show a peak in impedance at high bias voltages, attributed to inductor and capacitor(LC) circuit resonance, enhancing frequency response. Furthermore, 20 Gbps eye diagrams at-21 V and-9 dBm input power reveal signal to noise ratio(SNRs) of 5.30. This lateral SACM APD, compatible with the stand complementary metal oxide semiconductor(CMOS) process,shows that utilizing the peaking effect at low optical power increases bandwidth. 展开更多
关键词 PHOTODETECTORS optical communications RESPONSIVITY 3-dB bandwidth
下载PDF
Dynamic Response of Foundations during Startup of High-Frequency Tunnel Equipment
2
作者 Dawei Ruan Mingwei Hu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第7期821-844,共24页
The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is ... The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is supported by the foundation of the units,and the magnitude of vibration and the operating frequency fluctuate in different engineering contexts,leading to variations in the dynamic response of the foundation.The high-frequency units yield significantly diverse outcomes under different startup conditions and times,resulting in failure to meet operational requirements,influencing the normal function of the tunnel,and causing harm to the foundation structure,personnel,and property in severe cases.This article formulates a finite element numerical computation model for solid elements using three-dimensional elastic body theory and integrates field measurements to substantiate and ascertain the crucial parameter configurations of the finite element model.By proposing a comprehensive startup timing function for high-frequency dynamic machines under different startup conditions,simulating the frequency andmagnitude variations during the startup process,and suggesting functions for changes in frequency and magnitude,a simulated startup schedule function for high-frequency machines is created through coupling.Taking into account the selection of the transient dynamic analysis step length,the dynamic response results for the lower dynamic foundation during its fundamental frequency crossing process are obtained.The validation checks if the structural magnitude surpasses the safety threshold during the critical phase of unit startup traversing the structural resonance region.The design recommendations for high-frequency units’dynamic foundations are provided,taking into account the startup process of the machine and ensuring the safe operation of the tunnel. 展开更多
关键词 Tunnel equipment high-frequency units startup conditions transient dynamics dynamic response foundation design
下载PDF
A Temporary Frequency Response Strategy Using a Voltage Source-Based PermanentMagnet Synchronous Generator and Energy Storage Systems
3
作者 Baogang Chen Fenglin Miao +2 位作者 Jing Yang Chen Qi Wenyan Ji 《Energy Engineering》 EI 2024年第2期541-555,共15页
Energy storage systems(ESS)and permanent magnet synchronous generators(PMSG)are speculated to be able to exhibit frequency regulation capabilities by adding differential and proportional control loops with different c... Energy storage systems(ESS)and permanent magnet synchronous generators(PMSG)are speculated to be able to exhibit frequency regulation capabilities by adding differential and proportional control loops with different control objectives.The available PMSG kinetic energy and charging/discharging capacities of the ESS were restricted.To improve the inertia response and frequency control capability,we propose a short-term frequency support strategy for the ESS and PMSG.To this end,the weights were embedded in the control loops to adjust the participation of the differential and proportional controls based on the system frequency excursion.The effectiveness of the proposed control strategy was verified using PSCAD/EMTDC.The simulations revealed that the proposed strategy could improve the maximum rate of change of the frequency nadir and maximum frequency excursion.Therefore,it provides a promising solution of ancillary services for frequency regulation of PMSG and ESS. 展开更多
关键词 Inertial control PMSG ESS wind power generation frequency support
下载PDF
Capacitive energy storage from single pore to porous electrode identified by frequency response analysis 被引量:1
4
作者 Weiheng Li Qiu-An Huang +7 位作者 Yu Li Yuxuan Bai Nan Wang Jia Wang Yongming Hu Yufeng Zhao Xifei Li Jiujun Zhang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第2期384-405,I0010,共23页
Rate capability,peak power,and energy density are of vital importance for the capacitive energy storage(CES)of electrochemical energy devices.The frequency response analysis(FRA)is regarded as an efficient tool in stu... Rate capability,peak power,and energy density are of vital importance for the capacitive energy storage(CES)of electrochemical energy devices.The frequency response analysis(FRA)is regarded as an efficient tool in studying the CES.In the present work,a bi-scale impedance transmission line model(TLM)is firstly developed for a single pore to a porous electrode.Not only the TLM of the single pore is reparameterized but also the particle packing compactness is defined in the bi-scale.Subsequently,the CES properties are identified by FRA,focused on rate capability vs.characteristic frequency,peak power vs.equivalent series resistance,and energy density vs.low frequency limiting capacitance for a single pore to a porous electrode.Based on these relationships,the CES properties are numerically simulated and theoretically predicted for a single pore to a porous electrode in terms of intra-particle pore length,intra-particle pore diameter,inter-particle pore diameter,electrolyte conductivity,interfacial capacitance&exponent factor,electrode thickness,electrode apparent surface area,and particle packing compactness.Finally,the experimental diagnosis of four supercapacitors(SCs)with different electrode thicknesses is conducted for validating the bi-scale TLM and gaining an insight into the CES properties for a porous electrode to a single pore.The calculating results suggest,to some extent,the inter-particle pore plays a more critical role than the intra-particle pore in the CES properties such as the rate capability and the peak power density for a single pore to a porous electrode.Hence,in order to design a better porous electrode,more attention should be given to the inter-particle pore. 展开更多
关键词 Porous electrode Intra-particle pore Inter-particle pore Capacitive energy storage Electrochemical impedance spectroscopy frequency response analysis
下载PDF
A Selective‑Response Hypersensitive Bio‑Inspired Strain Sensor Enabled by Hysteresis Effect and Parallel Through‑Slits Structures
5
作者 Qun Wang Zhongwen Yao +8 位作者 Changchao Zhang Honglie Song Hanliang Ding Bo Li Shichao Niu Xinguan Huang Chuanhai Chen Zhiwu Han Luquan Ren 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第2期139-153,共15页
Flexible strain sensors are promising in sensing minuscule mechanical signals,and thereby widely used in various advanced fields.However,the effective integration of hypersensitivity and highly selective response into... Flexible strain sensors are promising in sensing minuscule mechanical signals,and thereby widely used in various advanced fields.However,the effective integration of hypersensitivity and highly selective response into one flexible strain sensor remains a huge challenge.Herein,inspired by the hysteresis strategy of the scorpion slit receptor,a bio-inspired flexible strain sensor(BFSS)with parallel through-slit arrays is designed and fabricated.Specifically,BFSS consists of conductive monolayer graphene and viscoelastic styrene–isoprene–styrene block copolymer.Under the synergistic effect of the bio-inspired slit structures and flexible viscoelastic materials,BFSS can achieve both hypersensitivity and highly selective frequency response.Remarkably,the BFSS exhibits a high gage factor of 657.36,and a precise identification of vibration frequencies at a resolution of 0.2 Hz through undergoing different morphological changes to high-frequency vibration and low-frequency vibration.Moreover,the BFSS possesses a wide frequency detection range(103 Hz)and stable durability(1000 cycles).It can sense and recognize vibration signals with different characteristics,including the frequency,amplitude,and waveform.This work,which turns the hysteresis effect into a"treasure,"can provide new design ideas for sensors for potential applications including human–computer interaction and health monitoring of mechanical equipment. 展开更多
关键词 Bio-inspired strain sensors Hysteresis effect HYPERSENSITIVITY Selective frequency response Health monitoring applications
下载PDF
Smartphone-based bridge frequency identification using vehicle contact-point response
6
作者 Liu Chengyin Zhu Yipeng +1 位作者 Zeng Qing Wu Xiaodong 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2023年第4期1031-1043,共13页
Bridge frequency(BF)identification using the vehicle scanning method has attracted considerable attention during the last two decades.However,most previous studies have adopted unrealistic vehicle models,thus finding ... Bridge frequency(BF)identification using the vehicle scanning method has attracted considerable attention during the last two decades.However,most previous studies have adopted unrealistic vehicle models,thus finding limited practical applications.This study proposes a smartphone-based BF identification method that uses the contact-point acceleration response of a four degree-of-freedom vehicle model.The said response can be inferred from the vehicle body response measured by a smartphone.For realizing practical applications,this method is incorporated into a self-developed smartphone app to obtain data smoothly and identify BFs in a timely manner.Numerical and experimental investigations are performed to verify the effectiveness of the proposed method.In particular,the robustness of this method is investigated numerically against various factors,including the vehicle speed,bridge span,road roughness,and bridge type.Furthermore,laboratory calibration tests are performed to investigate the accuracy of the smartphone gyroscope in measuring the angular velocity,where anomalous data are detected and eliminated.Laboratory experiment results for a simply supported bridge indicate that the proposed method can be used to identify the first two BFs with acceptable accuracy. 展开更多
关键词 bridge frequency(BF)identification vehicle–bridge interaction four degree-of-freedom(DOF)vehicle model contact-point response SMARTPHONE
下载PDF
Tool Condition Monitoring Based on Nonlinear Output Frequency Response Functions and Multivariate Control Chart
7
作者 Yufei Gui Ziqiang Lang +1 位作者 Zepeng Liu Hatim Laalej 《Journal of Dynamics, Monitoring and Diagnostics》 2023年第4期243-251,共9页
Tool condition monitoring(TCM)is a key technology for intelligent manufacturing.The objective is to monitor the tool operation status and detect tool breakage so that the tool can be changed in time to avoid significa... Tool condition monitoring(TCM)is a key technology for intelligent manufacturing.The objective is to monitor the tool operation status and detect tool breakage so that the tool can be changed in time to avoid significant damage to workpieces and reduce manufacturing costs.Recently,an innovative TCM approach based on sensor data modelling and model frequency analysis has been proposed.Different from traditional signal feature-based monitoring,the data from sensors are utilized to build a dynamic process model.Then,the nonlinear output frequency response functions,a concept which extends the linear system frequency response function to the nonlinear case,over the frequency range of the tooth passing frequency of the machining process are extracted to reveal tool health conditions.In order to extend the novel sensor data modelling and model frequency analysis to unsupervised condition monitoring of cutting tools,in the present study,a multivariate control chart is proposed for TCM based on the frequency domain properties of machining processes derived from the innovative sensor data modelling and model frequency analysis.The feature dimension is reduced by principal component analysis first.Then the moving average strategy is exploited to generate monitoring variables and overcome the effects of noises.The milling experiments of titanium alloys are conducted to verify the effectiveness of the proposed approach in detecting excessive flank wear of solid carbide end mills.The results demonstrate the advantages of the new approach over conventional TCM techniques and its potential in industrial applications. 展开更多
关键词 intelligent manufacturing multivariate control chart Nonlinear Autoregressive with eXogenous Input modelling Nonlinear Output frequency response Functions tool condition monitoring
下载PDF
Comparative analysis of thermodynamic and mechanical responses between underground hydrogen storage and compressed air energy storage in lined rock caverns
8
作者 Bowen Hu Liyuan Yu +5 位作者 Xianzhen Mi Fei Xu Shuchen Li Wei Li Chao Wei Tao Zhang 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第4期531-543,共13页
Underground hydrogen storage(UHS)and compressed air energy storage(CAES)are two viable largescale energy storage technologies for mitigating the intermittency of wind and solar power.Therefore,it is meaningful to comp... Underground hydrogen storage(UHS)and compressed air energy storage(CAES)are two viable largescale energy storage technologies for mitigating the intermittency of wind and solar power.Therefore,it is meaningful to compare the properties of hydrogen and air with typical thermodynamic storage processes.This study employs a multi-physical coupling model to compare the operations of CAES and UHS,integrating gas thermodynamics within caverns,thermal conduction,and mechanical deformation around rock caverns.Gas thermodynamic responses are validated using additional simulations and the field test data.Temperature and pressure variations of air and hydrogen within rock caverns exhibit similarities under both adiabatic and diabatic simulation modes.Hydrogen reaches higher temperature and pressure following gas charging stage compared to air,and the ideal gas assumption may lead to overestimation of gas temperature and pressure.Unlike steel lining of CAES,the sealing layer(fibre-reinforced plastic FRP)in UHS is prone to deformation but can effectively mitigates stress in the sealing layer.In CAES,the first principal stress on the surface of the sealing layer and concrete lining is tensile stress,whereas UHS exhibits compressive stress in the same areas.Our present research can provide references for the selection of energy storage methods. 展开更多
关键词 Underground hydrogen storage Compressed air energy storage Mechanical response Thermodynamic response Lined rock caverns
下载PDF
Envita’s Precision Cancer Care: 35-Fold Improvement in Response Rates
9
作者 Sheba Goklany John C. Oertle III +19 位作者 Ronald Matthias Jr. Daniel Warren David Medina Rory Sears Robert Zieve Kendra Quart Christopher Aussems Jon Moma Shannon Miller Zach Poteet Conner Coffin Courtney Middleton Erika Ware Phylicia Zarnosky Julie Nowak Winlove Suasin Daniel Conway Chad Burk Ruth Tan-Lim Dino Prato 《Journal of Cancer Therapy》 2024年第4期99-120,共22页
New clinical approaches are imperative beyond the widely adopted National Comprehensive Cancer Network (NCCN) guidelines, utilized by prominent cancer institutions. Cancer is the leading cause of death among individua... New clinical approaches are imperative beyond the widely adopted National Comprehensive Cancer Network (NCCN) guidelines, utilized by prominent cancer institutions. Cancer is the leading cause of death among individuals younger than 85 years within the United States. Despite significant technological advances, including the expenditure of hundreds of billions, treatment outcomes and overall survival have not notably improved for most types of advanced cancer over the last several decades. Over the past 24 years, Envita Medical Centers has pioneered a unique form of personalized treatment approach for late-stage and refractory cancer patients, introducing groundbreaking innovations in the field. Our integrated algorithm utilizes advanced genomics, transcriptomics, and highly tailored immunotherapy, resulting in remarkable outcome improvements. This study presents Envita’s innovative personalized treatment algorithms and examines the response outcomes of 199 late-stage cancer patients treated at Envita Medical Centers over a two-year period. Compared to standard of care and palliative chemotherapy, Envita’s treatment demonstrated a remarkable 35-fold improvement in overall response rates (Figure 1). Moreover, 88% of the patients, the majority presenting with Stage 3 or 4 cancer, experienced a 43-fold improvement in quality of life with minimal side effects, as compared to standard of care chemotherapy and palliative care. This revolutionary success is attributed to Envita’s personalized therapeutic algorithms, which incorporate customized immunotherapy. Envita’s precision care approach has also achieved a 100% better response rate compared to over 65 global chemotherapy clinical trials with more than 2700 patients. The results from this study suggest that a wider utilization of Envita’s personalized approach can significantly benefit patients with late-stage and refractory cancer. 展开更多
关键词 Envita Medical Centers Late-stage Cancer Overall response Rate Quality of Life Circulating Tumor Cells (CTCs) Mutant Allele frequency (MAF) Precision Care
下载PDF
Physical activity volume,frequency,and intensity:Associations with hypertension and obesity over 21 years in Australian women
10
作者 Gregore I.Mielke Ding Ding +3 位作者 Shelley E.Keating Bruno P.Nunes Ruth Brady Wendy J.Brown 《Journal of Sport and Health Science》 SCIE CAS CSCD 2024年第5期631-641,共11页
Background:Optimal patterns of accrual of recommended levels of physical activity(PA)for prevention of hypertension and obesity are not known.The overall aim of this study was to investigate whether different patterns... Background:Optimal patterns of accrual of recommended levels of physical activity(PA)for prevention of hypertension and obesity are not known.The overall aim of this study was to investigate whether different patterns of accumulation of PA are differentially associated with hypertension and obesity in Australian women over 21 years.Specifically,we investigated whether,for the same weekly volume of PA,the number of sessions(frequency)and vigorousness of PA(intensity)were associated with a reduction in the occurrence of hypertension and obesity in women.Methods:Data from the 1973-1978 and 1946-1951 cohorts of the Australian Longitudinal Study on Women's Health were analyzed(n=20,588;12%-16%with a Bachelor's or higher degree).Self-reported PA,hypertension,height,and weight were collected using mail surveys every 3 years from 1998/2000 to 2019/2021.Generalized Estimating Equation models with a 3-year lag model were used to investigate the association of PA volume(metabolic equivalent min/week)(none;33-499;500-999;≥1000,weekly frequency(none;1-2 times;3-4times;5-7 times;≥8 times),and the proportion of vigorous PA to total volume of PA(none;0%;1%-33%;34%-66%;67%-100%)with odds of hypertension and obesity from 2000 to 2021.Results:The cumulative incidence of hypertension was 6%in the 1973-1978 and 23%in the 1946-1951 cohort;27%of women in the 1973-1978;and 15%in the 1946-1951 cohort developed obesity over the period.Overall,a higher volume of PA was associated with reduced odds of hypertension and obesity.When the volume of PA was considered,the odds of hypertension did not vary according to the frequency or intensity of PA.However,increased proportion of vigorous PA to the total volume of PA was associated with a small additional reduction in the risk of obe sity.Conclusion:PA volume appears to be more important than the pattern of accumulation for the prevention of hypertension and obesity.Incorporating more sessions,particularly of vigorous-intensity PA,may provide extra benefits for the prevention of obesity. 展开更多
关键词 Physical activity frequency INTENSITY Incidences EPIDEMIOLOGY WOMEN
下载PDF
High-Precision Doppler Frequency Estimation Based Positioning Using OTFS Modulations by Red and Blue Frequency Shift Discriminator
11
作者 Shaojing Wang Xiaomei Tang +3 位作者 Jing Lei Chunjiang Ma Chao Wen Guangfu Sun 《China Communications》 SCIE CSCD 2024年第2期17-31,共15页
Orthogonal Time Frequency and Space(OTFS) modulation is expected to provide high-speed and ultra-reliable communications for emerging mobile applications, including low-orbit satellite communications. Using the Dopple... Orthogonal Time Frequency and Space(OTFS) modulation is expected to provide high-speed and ultra-reliable communications for emerging mobile applications, including low-orbit satellite communications. Using the Doppler frequency for positioning is a promising research direction on communication and navigation integration. To tackle the high Doppler frequency and low signal-to-noise ratio(SNR) in satellite communication, this paper proposes a Red and Blue Frequency Shift Discriminator(RBFSD) based on the pseudo-noise(PN) sequence.The paper derives that the cross-correlation function on the Doppler domain exhibits the characteristic of a Sinc function. Therefore, it applies modulation onto the Delay-Doppler domain using PN sequence and adjusts Doppler frequency estimation by red-shifting or blue-shifting. Simulation results show that the performance of Doppler frequency estimation is close to the Cramér-Rao Lower Bound when the SNR is greater than -15dB. The proposed algorithm is about 1/D times less complex than the existing PN pilot sequence algorithm, where D is the resolution of the fractional Doppler. 展开更多
关键词 channel estimation communication and navigation integration Orthogonal Time frequency and Space pseudo-noise sequence red-blue frequency shift discriminator
下载PDF
Enhancing quantum temporal steering via frequency modulation
12
作者 吴孟凯 程维文 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期239-245,共7页
Various strategies have been proposed to harness and protect space-like quantum correlations in different models under decoherence.However,little attention has been given to temporal-like correlations,such as quantum ... Various strategies have been proposed to harness and protect space-like quantum correlations in different models under decoherence.However,little attention has been given to temporal-like correlations,such as quantum temporal steering(TS),in this context.In this work,we investigate TS in a frequency-modulated two-level system coupled to a zero-temperature reservoir in both the weak and strong coupling regimes.We analyze the impact of various frequency-modulated parameters on the behavior of TS and non-Markovian.The results demonstrate that appropriate frequency-modulated parameters can enhance the TS of the two-level system,regardless of whether the system is experiencing Markovian or non-Markovian dynamics.Furthermore,a suitable ratio between modulation strength and frequency(i.e.,all zeroes of the 0th Bessel function J_(0)(δ/?))can significantly enhance TS in the strong coupling regime.These findings indicate that efficient and effective manipulation of quantum TS can be achieved through a frequency-modulated approach. 展开更多
关键词 quantum temporal steering frequency modulation DECOHERENCE
下载PDF
LncRNA pol-lnc78 as a ceRNA regulates antibacterial responses via suppression of pol-miR-n199-3p-mediated SARM down-regulation in Paralichthys olivaceus
13
作者 Xian-Hui Ning Bing Han +1 位作者 Ye Peng Shao-Wu Yin 《Zoological Research》 SCIE CSCD 2024年第1期25-35,共11页
Long non-coding RNAs(lncRNAs)function as key modulators in mammalian immunity,particularly due to their involvement in lncRNA-mediated competitive endogenous RNA(ceRNA)crosstalk.Despite their recognized significance i... Long non-coding RNAs(lncRNAs)function as key modulators in mammalian immunity,particularly due to their involvement in lncRNA-mediated competitive endogenous RNA(ceRNA)crosstalk.Despite their recognized significance in mammals,research on lncRNAs in lower vertebrates remains limited.In the present study,we characterized the first immune-related lncRNA(pol-lnc78)in the teleost Japanese flounder(Paralichthys olivaceus).Results indicated that pol-lnc78 acted as a ceRNA for pol-miR-n199-3p to target the sterile alpha and armadillo motif-containing protein(SARM),the fifth discovered member of the Toll/interleukin 1(IL-1)receptor(TIR)adaptor family.This ceRNA network regulated the antibacterial responses of flounder via the Toll-like receptor(TLR)signaling pathway.Specifically,SARM acted as a negative regulator and exacerbated bacterial infection by inhibiting the expression of inflammatory cytokines IL-1βand tumor necrosis factor-α(TNF-α).Pol-miR-n199-3p reduced SARM expression by specifically interacting with the 3’untranslated region(UTR),thereby promoting SARM-dependent inflammatory cytokine expression and protecting the host against bacterial dissemination.Furthermore,pol-lnc78 sponged pol-miR-n199-3p to ameliorate the inhibition of SARM expression.During infection,the negative regulators pol-lnc78 and SARM were significantly down-regulated,while pol-miR-n199-3p was significantly up-regulated,thus favoring host antibacterial defense.These findings provide novel insights into the mechanisms underlying fish immunity and open new horizons to better understand ceRNA crosstalk in lower vertebrates. 展开更多
关键词 LncRNA SARM miRNA ceRNA Antibacterial response
下载PDF
A Synchronization Acquisition Algorithm Based on the Frequency Hopping Pulses Combining
14
作者 She Honghan Cheng Yufan +4 位作者 Zhang Wenzihan Zhang Yaohui Zhao Yuheng Shen Haoran Mou Ying 《China Communications》 SCIE CSCD 2024年第4期74-87,共14页
As modern electromagnetic environments are more and more complex,the anti-interference performance of the synchronization acquisition is becoming vital in wireless communications.With the rapid development of the digi... As modern electromagnetic environments are more and more complex,the anti-interference performance of the synchronization acquisition is becoming vital in wireless communications.With the rapid development of the digital signal processing technologies,some synchronization acquisition algorithms for hybrid direct-sequence(DS)/frequency hopping(FH)spread spectrum communications have been proposed.However,these algorithms do not focus on the analysis and the design of the synchronization acquisition under typical interferences.In this paper,a synchronization acquisition algorithm based on the frequency hopping pulses combining(FHPC)is proposed.Specifically,the proposed algorithm is composed of two modules:an adaptive interference suppression(IS)module and an adaptive combining decision module.The adaptive IS module mitigates the effect of the interfered samples in the time-domain or the frequencydomain,and the adaptive combining decision module can utilize each frequency hopping pulse to construct an anti-interference decision metric and generate an adaptive acquisition decision threshold to complete the acquisition.Theory and simulation demonstrate that the proposed algorithm significantly enhances the antiinterference and anti-noise performances of the synchronization acquisition for hybrid DS/FH communications. 展开更多
关键词 adaptive anti-interference frequency hopping synchronization acquisition
下载PDF
Frequency and Risk Factors of Neonatal Macrosomia at Labe Regional Hospital in Guinea
15
作者 Mamadou Dian Mamoudou Diallo Mamadou Mansour Diallo +10 位作者 Mamadou Chérif Diallo Alpha Mamadou Diallo Kadija Dieng Mody Abdoulaye Barry Mamadou Alpha Diallo Kadidiatou Bah Abdou Mazid Diallo El’hadj Zainoul Bah Mamadou Malal Bori Diallo Mamadou Sanou Sylla Amadou Kaké 《Open Journal of Endocrine and Metabolic Diseases》 2024年第2期26-32,共7页
Macrosomia is defined as a term birth weight greater than or equal to 4000 grams, or greater than the 90 percentile of intrauterine growth curves. Excessive weight has harmful consequences for the newborn and is a maj... Macrosomia is defined as a term birth weight greater than or equal to 4000 grams, or greater than the 90 percentile of intrauterine growth curves. Excessive weight has harmful consequences for the newborn and is a major health concern. Objectives: To determine the frequency of neonatal macrosomia, describe risk factors and neonatal and maternal complications. Materials and methods: This was a cross-sectional study carried out between January and December 2022, involving newborns whose birth weight was greater than or equal to 4000 grams admitted to the neonatology unit of the Labe regional hospital. Results: 591 deliveries were recorded, 15 of which were macrosomic, representing a frequency of 2.54%. The average age of the women was 30.26 years. History of fetal macrosomia and diabetes was 93.33 and 71.43% respectively. The mean gestational age was 38.71 ± 0.75 SA, the mean antenatal consultation was 3 ± 0.8 and the mode of delivery was caesarean section (66.67%). Third-trimester ultrasound was performed in 53.33% of cases. Macrosomic newborns were male in 80% of cases. Neonatal complications were asphyxia (60%), hypoglycemia (20%) and hypocalcemia (13.33%). Factors associated with neonatal macrosomia were diabetes (P < 0.001), history of macrosomia (P Conclusion: this study shows that the frequency of neonatal macrosomia is 2.54% with high neonatal morbidity among newborns hospitalized in the neonatology unit of the Labé regional hospital. Screening for macrosomia risk factors during pregnancy is essential to prevent perinatal complications. 展开更多
关键词 frequency MACROSOMIA Labe
下载PDF
Robust free-space optical frequency transfer in time-varying link distances conditions
16
作者 童周 刘雷 +6 位作者 王家亮 操前 金志成 应康 韩申生 韩正甫 桂有珍 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期271-276,共6页
Future inter-satellite clock comparison on high orbit will require optical time and frequency transmission technology between moving objects.Here,we demonstrate robust optical frequency transmission under the conditio... Future inter-satellite clock comparison on high orbit will require optical time and frequency transmission technology between moving objects.Here,we demonstrate robust optical frequency transmission under the condition of variable link distance.This variable link is accomplished by the relative motion of a single telescope fixed on the experimental platform to a corner-cube reflector(CCR)installed on a sliding guide.Two acousto–optic modulators with different frequencies are used to separate forward signal from backward signal.With active phase noise suppression,when the CCR moves back and forth at a constant velocity of 20 cm/s and an acceleration of 20 cm/s^(2),we achieve the best frequency stability of 1.9×10^(-16) at 1 s and 7.9×10^(-19) at 1000 s indoors.This work paves the way for future studying optical frequency transfer between ultra-high-orbit satellites. 展开更多
关键词 FREE-SPACE optical frequency transfer variable link distance
下载PDF
Dynamic response of a thermal transistor to time-varying signals
17
作者 阮琴丽 刘文君 王雷 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期13-19,共7页
Thermal transistor,the thermal analog of an electronic transistor,is one of the most important thermal devices for microscopic-scale heat manipulating.It is a three-terminal device,and the heat current flowing through... Thermal transistor,the thermal analog of an electronic transistor,is one of the most important thermal devices for microscopic-scale heat manipulating.It is a three-terminal device,and the heat current flowing through two terminals can be largely controlled by the temperature of the third one.Dynamic response plays an important role in the application of electric devices and also thermal devices,which represents the devices’ability to treat fast varying inputs.In this paper,we systematically study two typical dynamic responses of a thermal transistor,i.e.,the response to a step-function input(a switching process)and the response to a square-wave input.The role of the length L of the control segment is carefully studied.It is revealed that when L is increased,the performance of the thermal transistor worsens badly.Both the relaxation time for the former process and the cutoff frequency for the latter one follow the power-law dependence on L quite well,which agrees with our analytical expectation.However,the detailed power exponents deviate from the expected values noticeably.This implies the violation of the conventional assumptions that we adopt. 展开更多
关键词 PHONON phononics thermal transistor dynamic response heat conduction
下载PDF
Gigahertz frequency hopping in an optical phase-locked loop for Raman lasers
18
作者 毛德凯 税鸿冕 +3 位作者 殷国玲 彭鹏 王春唯 周小计 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期60-65,共6页
Raman lasers are essential in atomic physics,and the development of portable devices has posed requirements for time-division multiplexing of Raman lasers.We demonstrate an innovative gigahertz frequency hopping appro... Raman lasers are essential in atomic physics,and the development of portable devices has posed requirements for time-division multiplexing of Raman lasers.We demonstrate an innovative gigahertz frequency hopping approach of a slave Raman laser within an optical phase-locked loop(OPLL),which finds practical application in an atomic gravimeter,where the OPLL frequently switches between near-resonance lasers and significantly detuned Raman lasers.The method merges the advantages of rapid and extensive frequency hopping with the OPLL’s inherent low phase noise,and exhibits a versatile range of applications in compact laser systems,promising advancements in portable instruments. 展开更多
关键词 Raman lasers optical phase-locked loop frequency hopping
下载PDF
The physiological role of the unfolded protein response in the nervous system
19
作者 Shuangchan Wu Wensheng Lin 《Neural Regeneration Research》 SCIE CAS CSCD 2024年第11期2411-2420,共10页
The unfolded protein response(UPR)is a cellular stress response pathway activated when the endoplasmic reticulum,a crucial organelle for protein folding and modification,encounters an accumulation of unfolded or misfo... The unfolded protein response(UPR)is a cellular stress response pathway activated when the endoplasmic reticulum,a crucial organelle for protein folding and modification,encounters an accumulation of unfolded or misfolded proteins.The UPR aims to restore endoplasmic reticulum homeostasis by enhancing protein folding capacity,reducing protein biosynthesis,and promoting protein degradation.It also plays a pivotal role in coordinating signaling cascades to determine cell fate and function in response to endoplasmic reticulum stress.Recent research has highlighted the significance of the UPR not only in maintaining endoplasmic reticulum homeostasis but also in influencing various physiological processes in the nervous system.Here,we provide an overview of recent findings that underscore the UPR’s involvement in preserving the function and viability of neuronal and myelinating cells under physiological conditions,and highlight the critical role of the UPR in brain development,memory storage,retinal cone development,myelination,and maintenance of myelin thickness. 展开更多
关键词 MYELIN NEURON OLIGODENDROCYTE Schwann cell unfolded protein response
下载PDF
Coherent optical frequency transfer via 972-km fiber link
20
作者 邓雪 张翔 +8 位作者 臧琦 焦东东 王丹 刘杰 高静 许冠军 董瑞芳 刘涛 张首刚 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期277-282,共6页
We demonstrate coherent optical frequency dissemination over a distance of 972 km by cascading two spans where the phase noise is passively compensated for.Instead of employing a phase discriminator and a phase lockin... We demonstrate coherent optical frequency dissemination over a distance of 972 km by cascading two spans where the phase noise is passively compensated for.Instead of employing a phase discriminator and a phase locking loop in the conventional active phase control scheme,the passive phase noise cancellation is realized by feeding double-trip beat-note frequency to the driver of the acoustic optical modulator at the local site.This passive scheme exhibits fine robustness and reliability,making it suitable for long-distance and noisy fiber links.An optical regeneration station is used in the link for signal amplification and cascaded transmission.The phase noise cancellation and transfer instability of the 972-km link is investigated,and transfer instability of 1.1×10^(-19)at 10^(4)s is achieved.This work provides a promising method for realizing optical frequency distribution over thousands of kilometers by using fiber links. 展开更多
关键词 optical frequency transfer fiber link phase noise cancellation
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部