B4C, SiC and C, Cu functionally graded-materials (FGMs) have been developed by plasma spraying and hot pressing. Their high-heat flux properties have been investigated by high energy laser and electron beam for the si...B4C, SiC and C, Cu functionally graded-materials (FGMs) have been developed by plasma spraying and hot pressing. Their high-heat flux properties have been investigated by high energy laser and electron beam for the simulation of plasma disruption process of the future fusion reactors, And a study on eroded products of B4C/Cu FGM under transient thermal load of electron beam was performed. In the experiment, SEM and EDS analysis indicated that B4C and SiC were decomposed, carbon was preferentially evaporated under high thermal load, and a part of Si and Cu were melted, in addition, the splash of melted metal and the particle emission of brittle destruction were also found. Different erosive behaviors of carbon-based materials (CBMs) caused by laser and electron beam were also discussed.展开更多
Water-cooled flat-type W/Cu Cr Zr plasma facing components with an interlayer of oxygen-free copper(OFC) have been developed by using vacuum brazing route.The OFC layer for the accommodation of thermal stresses was ...Water-cooled flat-type W/Cu Cr Zr plasma facing components with an interlayer of oxygen-free copper(OFC) have been developed by using vacuum brazing route.The OFC layer for the accommodation of thermal stresses was cast onto the surface of W at a temperature range of 1150oC-1200 oC in a vacuum furnace.The W/OFC cast tiles were vacuum brazed to a Cu Cr Zr heat sink at 940 oC using the silver-free filler material Cu Mn Si Cr.The microstructure,bonding strength,and high heat flux properties of the brazed W/Cu Cr Zr joint samples were investigated.The W/Cu joint exhibits an average tensile strength of 134 MPa,which is about the same strength as pure annealed copper.High heat flux tests were performed in the electron beam facility EMS-60.Experimental results indicated that the brazed W/Cu Cr Zr mock-up experienced screening tests of up to 15 MW/m^2 and cyclic tests of 9 MW/m^2 for 1000 cycles without visible damage.展开更多
China, as one of the members of ITER (international thermonuclear experimental reactor) project, one of the most important construction tasks is the fabrication of the first wall panel and shield blankets, which is ...China, as one of the members of ITER (international thermonuclear experimental reactor) project, one of the most important construction tasks is the fabrication of the first wall panel and shield blankets, which is the key engineering technology of ITER construction and might be one of the crucial issues of the future reactor too. Since 2004, an associated research team including Southwestern Institute of Physics ( SWIP ), Ninxia Non-ferrous Metal Co. Itd and Chinese Institute of Engineering Physics, as well as Nuclear Power Institute of China has been established. Up to now, several series of interlayer for hot isostatic press ( HIP ) connection of beryllium and CuCrZr alloy have been tested. They are titanium film or coating, Cu coating and Al or AISiMg alloy etc. The bonding strength (tensile or shear strength ) of HIPed Be/Cu joints is up to 100 MPa.展开更多
As an important component of tokamaks,the divertor is mainly responsible for extracting heat and helium ash,and the targets of the divertor need to withstand high heat flux of 10 MW m-2 for steady-state operation.In t...As an important component of tokamaks,the divertor is mainly responsible for extracting heat and helium ash,and the targets of the divertor need to withstand high heat flux of 10 MW m-2 for steady-state operation.In this study,we proposed a new strategy,using microchannel cooling technology to remove high heat load on the targets of the divertor.The results demonstrated that the microchannel-based W/Cu flat-type mock-up successfully withstood the thermal fatigue test of 1000 cycles at 10 MW m^(-2)with cooling water of 26 l min^(-1),30°C(inlet),0.8 MPa(inlet),15 s power on and 15 s dwell time;the maximum temperature on the heat-loaded surface(W surface)of the mock-up was 493°C,which is much lower than the recrystallization temperature of W(1200°C).Moreover,no occurrence of macrocrack and‘hot spot’at the W surface,as well as no detachment of W/Cu tiles were observed during the thermal fatigue testing.These results indicate that microchannel cooling technology is an efflcient method for removing the heat load of the divertor at a low flow rate.The present study offers a promising solution to replace the monoblock design for the EAST divertor.展开更多
文摘B4C, SiC and C, Cu functionally graded-materials (FGMs) have been developed by plasma spraying and hot pressing. Their high-heat flux properties have been investigated by high energy laser and electron beam for the simulation of plasma disruption process of the future fusion reactors, And a study on eroded products of B4C/Cu FGM under transient thermal load of electron beam was performed. In the experiment, SEM and EDS analysis indicated that B4C and SiC were decomposed, carbon was preferentially evaporated under high thermal load, and a part of Si and Cu were melted, in addition, the splash of melted metal and the particle emission of brittle destruction were also found. Different erosive behaviors of carbon-based materials (CBMs) caused by laser and electron beam were also discussed.
基金supported by National Natural Science Foundation of China(No.11205049)the National Magnetic Confinement Fusion Science Program of China(No.2011GB110004)
文摘Water-cooled flat-type W/Cu Cr Zr plasma facing components with an interlayer of oxygen-free copper(OFC) have been developed by using vacuum brazing route.The OFC layer for the accommodation of thermal stresses was cast onto the surface of W at a temperature range of 1150oC-1200 oC in a vacuum furnace.The W/OFC cast tiles were vacuum brazed to a Cu Cr Zr heat sink at 940 oC using the silver-free filler material Cu Mn Si Cr.The microstructure,bonding strength,and high heat flux properties of the brazed W/Cu Cr Zr joint samples were investigated.The W/Cu joint exhibits an average tensile strength of 134 MPa,which is about the same strength as pure annealed copper.High heat flux tests were performed in the electron beam facility EMS-60.Experimental results indicated that the brazed W/Cu Cr Zr mock-up experienced screening tests of up to 15 MW/m^2 and cyclic tests of 9 MW/m^2 for 1000 cycles without visible damage.
文摘China, as one of the members of ITER (international thermonuclear experimental reactor) project, one of the most important construction tasks is the fabrication of the first wall panel and shield blankets, which is the key engineering technology of ITER construction and might be one of the crucial issues of the future reactor too. Since 2004, an associated research team including Southwestern Institute of Physics ( SWIP ), Ninxia Non-ferrous Metal Co. Itd and Chinese Institute of Engineering Physics, as well as Nuclear Power Institute of China has been established. Up to now, several series of interlayer for hot isostatic press ( HIP ) connection of beryllium and CuCrZr alloy have been tested. They are titanium film or coating, Cu coating and Al or AISiMg alloy etc. The bonding strength (tensile or shear strength ) of HIPed Be/Cu joints is up to 100 MPa.
基金financial support from the National MCF Energy R&D Program(No.2018YFE0312300)National Natural Science Foundation of China(No.51706100)+1 种基金the Natural Science Foundation of Jiangsu Province(No.BK20180477)Fundamental Research Funds for the Central Universities(No.30918011205)。
文摘As an important component of tokamaks,the divertor is mainly responsible for extracting heat and helium ash,and the targets of the divertor need to withstand high heat flux of 10 MW m-2 for steady-state operation.In this study,we proposed a new strategy,using microchannel cooling technology to remove high heat load on the targets of the divertor.The results demonstrated that the microchannel-based W/Cu flat-type mock-up successfully withstood the thermal fatigue test of 1000 cycles at 10 MW m^(-2)with cooling water of 26 l min^(-1),30°C(inlet),0.8 MPa(inlet),15 s power on and 15 s dwell time;the maximum temperature on the heat-loaded surface(W surface)of the mock-up was 493°C,which is much lower than the recrystallization temperature of W(1200°C).Moreover,no occurrence of macrocrack and‘hot spot’at the W surface,as well as no detachment of W/Cu tiles were observed during the thermal fatigue testing.These results indicate that microchannel cooling technology is an efflcient method for removing the heat load of the divertor at a low flow rate.The present study offers a promising solution to replace the monoblock design for the EAST divertor.