期刊文献+
共找到1,569篇文章
< 1 2 79 >
每页显示 20 50 100
Kinematic deformation and intensity assessment of the 2021 Maduo M_(S)7.4 earthquake in Qinghai revealed by high-frequency GNSS
1
作者 Yu Li Yuebing Wang +2 位作者 Lijiang Zhao Hongbo Shi Pingping Wang 《Geodesy and Geodynamics》 EI CSCD 2024年第3期230-240,共11页
Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advance... Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advancement of GNSS observation and data processing makes it play an important role in this field,especially the high-frequency GNSS.We used the differential positioning method to calculate the 1 HZ GNSS data from 98 sites within 1000 km of the M_(S)7.4 Maduo earthquake epicenter.The kinematic deformation field and the distribution of the seismic intensity by using the peak ground velocity derived from displacement waveforms were obtained.The results show that:1)Horizontal coseismic response deformation levels ranging from 25 mm to 301 mm can be observed within a 1000 km radius from the epicenter.Coseismic response deformation on the east and west sides shows bilateral asymmetry,which markedly differs from the symmetry presented by surface rupture.2)The seismic intensity obtained through high-frequency GNSS and field investigations exhibits good consistency of the scope and orientation in the high seismic intensity area,although the former is generally slightly smaller than the latter.3)There may exist obstacles on the eastern side of the seismogenic fault.The Maduo earthquake induced a certain tectonic stress loading effect on the western Kunlun Pass-Jiangcuo fault(KPJF)and Maqin-Maqu segment,resulting in higher seismic risk in the future. 展开更多
关键词 Maduo earthquake high-frequency GNSS Kinematic deformation Seismic intensity
下载PDF
The relationship between the high-frequency performance of supercapacitors and the type of doped nitrogen in the carbon electrode
2
作者 FAN Ya-feng YI Zong-lin +6 位作者 ZHOU Yi XIE Li-jing SUN Guo-hua WANG Zhen-bing Huang Xian-hong SU Fang-yuan CHEN Cheng-meng 《新型炭材料(中英文)》 SCIE EI CAS CSCD 北大核心 2024年第5期1015-1026,共12页
Nitrogen doping has been widely used to improve the performance of carbon electrodes in supercapacitors,particularly in terms of their high-frequency response.However,the charge storage and electrolyte ion response me... Nitrogen doping has been widely used to improve the performance of carbon electrodes in supercapacitors,particularly in terms of their high-frequency response.However,the charge storage and electrolyte ion response mechanisms of different nitrogen dopants at high frequencies are still unclear.In this study,melamine foam carbons with different configurations of surfacedoped N were formed by gradient carbonization,and the effects of the configurations on the high-frequency response behavior of the supercapacitors were analyzed.Using a combination of experiments and first-principle calculations,we found that pyrrolic N,characterized by a higher adsorption energy,increases the charge storage capacity of the electrode at high frequencies.On the other hand,graphitic N,with a lower adsorption energy,increases the speed of ion response.We propose the use of adsorption energy as a practical descriptor for electrode/electrolyte design in high-frequency applications,offering a more universal approach for improving the performance of N-doped carbon materials in supercapacitors. 展开更多
关键词 high-frequency supercapacitors Carbon electrodes Doped nitrogen species Adsorption energy DESCRIPTOR
下载PDF
Dynamic Response of Foundations during Startup of High-Frequency Tunnel Equipment
3
作者 Dawei Ruan Mingwei Hu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第7期821-844,共24页
The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is ... The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is supported by the foundation of the units,and the magnitude of vibration and the operating frequency fluctuate in different engineering contexts,leading to variations in the dynamic response of the foundation.The high-frequency units yield significantly diverse outcomes under different startup conditions and times,resulting in failure to meet operational requirements,influencing the normal function of the tunnel,and causing harm to the foundation structure,personnel,and property in severe cases.This article formulates a finite element numerical computation model for solid elements using three-dimensional elastic body theory and integrates field measurements to substantiate and ascertain the crucial parameter configurations of the finite element model.By proposing a comprehensive startup timing function for high-frequency dynamic machines under different startup conditions,simulating the frequency andmagnitude variations during the startup process,and suggesting functions for changes in frequency and magnitude,a simulated startup schedule function for high-frequency machines is created through coupling.Taking into account the selection of the transient dynamic analysis step length,the dynamic response results for the lower dynamic foundation during its fundamental frequency crossing process are obtained.The validation checks if the structural magnitude surpasses the safety threshold during the critical phase of unit startup traversing the structural resonance region.The design recommendations for high-frequency units’dynamic foundations are provided,taking into account the startup process of the machine and ensuring the safe operation of the tunnel. 展开更多
关键词 Tunnel equipment high-frequency units startup conditions transient dynamics dynamic response foundation design
下载PDF
Review of the Analysis and Suppression for High-frequency Oscillations of the Grid-connected Wind Power Generation System
4
作者 Bo Pang Qi Si +4 位作者 Pan Jiang Kai Liao Xiaojuan Zhu Jianwei Yang Zhengyou He 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期127-142,共16页
High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is... High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is becoming more and more vital for the development of wind power.The HFO phenomenon of wind turbines under different scenarios usually has different mechanisms.Hence,engineers need to acquire the working mechanisms of the different HFO damping technologies and select the appropriate one to ensure the effective implementation of oscillation damping in practical engineering.This paper introduces the general assumptions of WPGS when analyzing HFO,systematically summarizes the reasons for the occurrence of HFO in different scenarios,deeply analyses the key points and difficulties of HFO damping under different scenarios,and then compares the technical performances of various types of HFO suppression methods to provide adequate references for engineers in the application of technology.Finally,this paper discusses possible future research difficulties in the problem of HFO,as well as the possible future trends in the demand for HFO damping. 展开更多
关键词 Damping method high-frequency oscillation STABILITY Wind power generation
下载PDF
Efficient activation of the Co/SBA-15catalyst by high-frequency AC-DBD plasma thermal effects for toluene removal
5
作者 李越 姜楠 +5 位作者 刘政妍 秦亮 彭邦发 王荣刚 孙玉荣 李杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期84-94,共11页
Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated d... Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated during the discharge process leads to energy waste and low energy utilization efficiency.In this work,an innovative DBD thermally-conducted catalysis(DBD-TCC)system,integrating high-frequency AC-DBD plasma and its generated thermal effects to activate the Co/SBA-15 catalyst,was employed for toluene removal.Specifically,Co/SBA-15 catalysts are closely positioned to the ground electrode of the plasma zone and can be heated and activated by the thermal effect when the voltage exceeds 10 k V.At12.4 k V,the temperature in the catalyst zone reached 261℃ in the DBD-TCC system,resulting in an increase in toluene degradation efficiency of 17%,CO_(2)selectivity of 21.2%,and energy efficiency of 27%,respectively,compared to the DBD system alone.In contrast,the DBD thermally-unconducted catalysis(DBD-TUC)system fails to enhance toluene degradation due to insufficient heat absorption and catalytic activation,highlighting the crucial role of AC-DBD generated heat in the activation of the catalyst.Furthermore,the degradation pathway and mechanism of toluene in the DBD-TCC system were hypothesized.This work is expected to provide an energy-efficient approach for high-frequency AC-DBD plasma removal of VOCs. 展开更多
关键词 high-frequency alternating-current power thermal effect dielectric barrier discharge toluene degradation Co/SBA-15 catalysts
下载PDF
Effects of unilateral superimposed high-frequency jet ventilation on porcine hemodynamics and gas exchange during one-lung flooding
6
作者 Thomas Lesser Frank Wolfram +1 位作者 Conny Braun Reiner Gottschall 《World Journal of Experimental Medicine》 2024年第1期88-99,共12页
BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is ... BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is necessary for therapeutic ultrasound applications.However,whether unilateral SHFJV allows adequate hemodynamics and gas exchange is unclear.AIM To compared SHFJV with pressure-controlled ventilation(PCV)during OLF by assessing hemodynamics and gas exchange in different animal positions.METHODS SHFJV or PCV was used alternatingly to ventilate the non-flooded lungs of the 12 anesthetized pigs during OLF.The animal positions were changed from left lateral position to supine position(SP)to right lateral position(RLP)every 30 min.In each position,ventilation was maintained for 15 min in both modalities.Hemodynamic variables and arterial blood gas levels were repeatedly measured.RESULTS Unilateral SHFJV led to lower carbon dioxide removal than PCV without abnormally elevated carbon dioxide levels.SHFJV slightly decreased oxygenation in SP and RLP compared with PCV;the lowest values of PaO_(2) and PaO_(2)/FiO_(2) ratio were found in SP[13.0;interquartile range(IQR):12.6-5.6 and 32.5(IQR:31.5-38.9)kPa].Conversely,during SHFJV,the shunt fraction was higher in all animal positions(highest in the RLP:0.30).CONCLUSION In porcine model,unilateral SHFJV may provide adequate ventilation in different animal positions during OLF.Lower oxygenation and CO_(2) removal rates compared to PCV did not lead to hypoxia or hypercapnia.SHFJV can be safely used for lung tumor ablation to minimize ventilation-induced lung motion. 展开更多
关键词 One-lung ventilation Unilateral superimposed high-frequency jet ventilation One-lung flooding
下载PDF
Therapeutic efficacy of methylprednisolone sodium succinate via diverse administration routes for mid-to high-frequency sudden sensorineural hearing loss
7
作者 Xiang-Da Meng Ting-Ting Li Li-Min Deng 《World Journal of Clinical Cases》 SCIE 2024年第18期3321-3331,共11页
BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use o... BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use of methylprednisolone sodium succinate(MPSS)via different administration routes,in combination with conventional medications,remains a topic of interest.AIM To compare the therapeutic efficacy of MPSS administered via different routes in combination with conventional drugs for the treatment of mid-to high-frequency SSNHL.METHODS The medical records of 109 patients with mid-to high-frequency SSNHL were analyzed.The patients were divided into three groups based on the route of administration:Group A[intratympanic(IT)injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection],Group B(intravenous injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection),and Group C(single IT injection of MPSS).The intervention effects were compared and analyzed.RESULTS The posttreatment auditory thresholds in Group A(21.23±3.34)were significantly lower than those in Groups B(28.52±3.36)and C(30.23±4.21;P<0.05).Group A also exhibited a significantly greater speech recognition rate(92.23±5.34)than Groups B and C.The disappearance time of tinnitus,time to hearing recovery,and disappearance time of vertigo in Group A were significantly shorter than those in Groups B and C(P<0.05).The total effective rate in Group A(97.56%)was significantly greater than that in Groups B and C(77.14%and 78.79%,χ^(2)=7.898,P=0.019).Moreover,the incidence of adverse reactions in Groups A and C was significantly lower than that in Group B(4.88%,3.03%vs 2.57%,χ^(2)=11.443,P=0.003),and the recurrence rate in Group A was significantly lower than that in Groups B and C(2.44%vs 20.00%vs 21.21%,χ^(2)=7.120,P=0.028).CONCLUSION IT injection of MPSS combined with conventional treatment demonstrates superior efficacy and safety compared to systemic administration via intravenous infusion and a single IT injection of MPSS.This approach effectively improves patients'hearing and reduces the risk of disease recurrence. 展开更多
关键词 Sudden loss of hearing at middle-and high-frequency of the descending type Methylprednisolone sodium succinate Intratympanic injection Intravenous injection
下载PDF
High Joule heat as a risk factor for post-endoscopic submucosal dissection electrocoagulation syndrome:A multicenter prospective study
8
作者 Masanori Ochi Asaji Yamamoto +9 位作者 Satoshi Suematsu Keita Fukuda Kenjiro Morishige Yasuhiro Oka Yuta Ishikawa Shunsuke Ueyama Yoshinori Hiroshima Yoshio Omae Fumihiko Kusano Toshiro Kamoshida 《World Journal of Gastrointestinal Endoscopy》 2024年第12期668-677,共10页
BACKGROUND Thermal damage may lead to inflammation of the peeled mucosal surface during endoscopic submucosal dissection(ESD).AIM To determine the effect of Joule heat on the onset of post-ESD electrocoagulation syndr... BACKGROUND Thermal damage may lead to inflammation of the peeled mucosal surface during endoscopic submucosal dissection(ESD).AIM To determine the effect of Joule heat on the onset of post-ESD electrocoagulation syndrome(PECS).METHODS In this prospective study,PECS was characterized by in-hospital fever(white blood cell count:≥10000μ/L or body temperature≥37.5°C)and abdominal pain(visual analog scale score≥30 mm during hospitalization or increased by≥20 mm from baseline at admission).High Joule heat was defined as 15390 J.Between April 2020 and April 2024,209 patients underwent colorectal ESD;those with intraoperative perforation or penetration were excluded.The remaining 202 patients were divided into the PECS and non-PECS groups.RESULTS PECS occurred in 30(14.9%)patients.Multivariate analysis revealed high Joule heat as an independent factor associated with PECS(odds ratio=7.96;95%confidence interval:2.91-21.8,P<0.01).The procedure time and presence of lesions in the right colon were not associated with PECS.CONCLUSION Accumulated thermal damage on the peeled mucosal surface should be considered during PECS onset.This thermal damage is likely a major component of the mechanism underlying PECS. 展开更多
关键词 Colorectal tumors Colorectal endoscopic submucosal dissection Joule heat Post-endoscopic submucosal dissection electrocoagulation syndrome Thermal damage
下载PDF
A Probe into Learners'Colligational Use of High-frequency Verbs
9
作者 李新利 《海外英语》 2011年第10X期339-342,共4页
This study attempts to examine the colligational use of the high-frequency verbs DO, HAVE and BE in Chinese EFL learners'written production in the CIA (Contrastive Interlanguage Analysis) approach. Findings of the... This study attempts to examine the colligational use of the high-frequency verbs DO, HAVE and BE in Chinese EFL learners'written production in the CIA (Contrastive Interlanguage Analysis) approach. Findings of the study indicate that: Chinese learners use a much smaller variety of colligational patterns, they tend to underuse the inflected forms of these verbs in their colligations and they tend to use pronouns as the subject of these verbs. Though at advanced level, they still have difficulty with grammar in terms of tense, aspect and voice. The influence of L1 transfer, the learners'spoken style in writing, the classroom teaching and the learners'use of the avoidance strategy are thought to be the major reasons. The findings in this study may have some light to shed on the EFL teaching and research in China. 展开更多
关键词 high-frequency VERBS colligations CIA
下载PDF
Optimizing electrocoagulation process for the treatment of biodiesel wastewater using response surface methodology 被引量:12
10
作者 Orathai Chavalparit Maneerat Ongwandee 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2009年第11期1491-1496,共6页
The production of biodiesel through a transesterification method produces a large amount of wastewater that contains high levels of chemical oxygen demand (COD) and oil and grease (O&G). Currently, flotation is t... The production of biodiesel through a transesterification method produces a large amount of wastewater that contains high levels of chemical oxygen demand (COD) and oil and grease (O&G). Currently, flotation is the conventional primary treatment for O&G removal prior to biological treatments. In this study, electrocoagulation (EC) was adopted to treat the biodiesel wastewater. The effects of initial pH, applied voltage, and reaction time on the EC process for the removal of COD, O&G, and suspended solids (SS) were investigated using one factor at a time experiment. Furthermore, the Box-Behnken design, an experimental design for response surface methodology (RSM), was used to create a set of 15 experimental runs needed for optimizing of the operating conditions. Quadratic regression models with estimated coefficients were developed to describe the pollutant removals. The experimental results show that EC could effectively reduce COD, O&G, and SS by 55.43%, 98.42%, and 96.59%, respectively, at the optimum conditions of pH 6.06, applied voltage 18.2 V, and reaction time 23.5 min. The experimental observations were in reasonable agreement with the modeled values. 展开更多
关键词 biodiesel wastewater electrocoagulation Box-Behnken design response surface methodology
下载PDF
Treatment of tannery wastewater by electrocoagulation 被引量:10
11
作者 FENG Jing-wei SUN Ya-bing ZHENG Zheng ZHANG Ji-biao LI Shu TIAN Yuan-chun 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第12期1409-1415,共7页
Treatment of tannery wastewater by electrocoagulation with low cell current (≤ 1A) and soluble electrodes (mild steel electrodes and aluminum electrodes) was studied. Compared with aluminum electrodes, mild steel... Treatment of tannery wastewater by electrocoagulation with low cell current (≤ 1A) and soluble electrodes (mild steel electrodes and aluminum electrodes) was studied. Compared with aluminum electrodes, mild steel electrodes were more effective for the removal of sulfide, with a removal efficiency of over 90%. But during the treatment process, black color precipitate typical to iron(Ⅱ) sulfides was produced. While aluminum electrodes were effective to eliminate the colority of the effluent, the removal efficiency of sulfide was lower than 12%. The mechanisms of the removal of chemical oxygen demand, ammonia, total organic carbon, sulfide and colority with the two soluble electrodes (mild steel and aluminum electrodes) were discussed in detail. In order to exert the predominance of diffenent types of electrodes, the tannery wastewater was treated using mild steel electrodes first followed by the filter and finally by the aluminum electrodes, the elimination rates of chemical oxygen demand, ammonia, total organic carbon, sulfide and colority were 68.0%, 43.1%, 55.1%, 96.7% and 84.3%, respectively, with the initial concentrations 2413.1 mg/L, 223.4 mg/L, 1000.4 mg/L, 112.3 mg/L and 256 dilution times, respectively. The absorbance spectra and energy consumption during electrocoagulation process were also discussed. 展开更多
关键词 tannery wastewater electrocoagulation mild steel electrodes aluminum electrodes
下载PDF
An alternative treatment process for upgrade of petroleum refinery wastewater using electrocoagulation 被引量:8
12
作者 Dhorgham Skban Ibrahim Mohan Lathalakshmi +1 位作者 Appusamy Muthukrishnaraj Natesan Balasubramanian 《Petroleum Science》 SCIE CAS CSCD 2013年第3期421-430,共10页
An electrocoagulation treatment process was developed for treatment and upgrade of petroleum refinery effluent (wastewater), instead of the conventional methods, which can consume higher amounts of chemicals and pro... An electrocoagulation treatment process was developed for treatment and upgrade of petroleum refinery effluent (wastewater), instead of the conventional methods, which can consume higher amounts of chemicals and produce larger amounts of sludge. The effect of the operation parameters, such as current density, initial pH, anode material, anode dissolution, energy consumption and electrolysis time, on treatment efficiency was investigated. The experimental results showed that the effluent can be effectively treated under optimal conditions. Fourier transform infrared (FTIR) analysis of the effluent, and scanning electron microscopy (SEM) coupled with energy dispersive analysis of X-rays (EDAX) of the sludge produced, revealed that the unwanted pollutants can be eliminated. The electrocoagulation treatment process was assessed by using the removal efficiency of chemical oxygen demand (COD), total suspended solids (TSS), and the general physicochemical characteristics of wastewater, and the results showed that the electrocoagulation is an efficient process for recycling of petroleum wastewater; it is faster and provides better quality of treated water than the conventional methods. 展开更多
关键词 COD/TSS reduction electrocoagulation petroleum refinery effluent RECYCLE sludge analysis.
下载PDF
Risk factors of electrocoagulation syndrome after esophageal endoscopic submucosal dissection 被引量:5
13
作者 Dae Won Ma Young Hoon Youn +3 位作者 Da Hyun Jung Jae Jun Park Jie-Hyun Kim Hyojin Park 《World Journal of Gastroenterology》 SCIE CAS 2018年第10期1144-1151,共8页
AIM To investigate post endoscopic submucosal dissection electrocoagulation syndrome(PEECS) of the esophagus.METHODS We analyzed 55 consecutive cases with esophageal endoscopic submucosal dissection for superficial es... AIM To investigate post endoscopic submucosal dissection electrocoagulation syndrome(PEECS) of the esophagus.METHODS We analyzed 55 consecutive cases with esophageal endoscopic submucosal dissection for superficial esophageal squamous neoplasms at a tertiary referral hospital in South Korea. Esophageal PEECS was defined as "mild" meeting one of the following criteria without any obvious perforation: fever(≥ 37.8 ℃), leukocytosis(> 10800 cells/μl), or regional chest pain more than 5/10 points as rated on a numeric pain intensity scale. The grade of PEECS was determined as "severe" when meet two or more of above criteria.RESULTS We included 51 cases without obvious complications in the analysis. The incidence of mild and severe esophageal PEECS was 47.1% and 17.6%, respectively. Risk factor analysis revealed that resected area, procedure time, and muscle layer exposure were significantly associated with PEECS. In multivariate analysis, a resected area larger than 6.0 cm^2(OR = 4.995, 95%CI: 1.110-22.489, P = 0.036) and muscle layer exposure(OR = 5.661, 95%CI: 1.422-22.534, P = 0.014) were independent predictors of esophageal PEECS. All patients with PEECS had favorable outcomes with conservative management approaches, such as intravenous hydration or antibiotics.CONCLUSION Clinicians should consider the possibility of esophageal PEECS when the resected area exceeds 6.0 cm^2 or when the muscle layer exposure is noted. 展开更多
关键词 electrocoagulation Endoscopic SUBMUCOSAL DISSECTION ESOPHAGEAL NEOPLASM SYNDROME
下载PDF
Experimental and clinical study of influence of high-frequency electric surgical knives on healing of abdominal incision 被引量:24
14
作者 Guang-Wei Ji Yuan-Zhi Wu +14 位作者 Xu Wang Hua-Xiong Pan Ping Li Wan-Ying Du Zhi Qi An Huang Li-Wei Zhang Li Zhang Wen Chen Guang-Hua Liu Hui Xu Quan Li Ai-Hua Yuan Xiao-Ping He Guo-Hua Mei 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第25期4082-4085,共4页
AIM: To study the influence of high-frequency electric surgical knives on healing of abdominal incision. METHODS: Two hundred and forty white rats were divided into 10^0, 10^2, 10^5, and 10^8 groups and rat models o... AIM: To study the influence of high-frequency electric surgical knives on healing of abdominal incision. METHODS: Two hundred and forty white rats were divided into 10^0, 10^2, 10^5, and 10^8 groups and rat models of abdominal operation were induced by using electric surgical knives and common lancets respectively. Then they were respectively given hypodermic injections of normal saline and 0.2 mL quantitative mixture of Escherichia coil, Staphylococcus aureus and Pseudornonas aeruginosa at a concentration of 10^2, 10^5 and 10^8. On the basis of the animal experiment, 220 patients undergoing abdominal operations (above type Ⅱ) were randomly allocated into one of following three groups: electric knife (EK, 93 cases), electro-coagulation (EC, 55 cases) and control (72 cases). High-frequency electric surgical knives were used to dissect abdominal tissues and electro-coagulation for hemostasis in EK group. Common lancets and electro-coagulation were applied in EC group. Common lancets and tieing silk suture were used in the controls. RESULTS: In all the groups except group 10^0, infection rate of incisional wounds made by electric surgical knives were remarkably higher than that with common lancets. Furthermore, there were significant differences in groups 10^2, 10^5, and 10^8 (P 〈 0.05), but not in group 10^0 (P 〉 0.05) between EK and EC groups. Clinical studies showed a delayed wound healing in 16 cases (17.20%) in EK, 11 cases (16.36%) in EC and 2 cases (2.86%)in the control groups. A significant difference between EK and the control groups (χ^2= 8.57, P 〈 0.01), and between EC and the control groups (χ^2 = 5.66, P 〈 0.05) was observed, but not between EK and EC (χ^2= 0.017, P 〉 0.05). CONCLUSION: High-frequency electric knives may remarkably delay abdominal incision healing. Its application should be minimized so as to reduce the possibility of postoperative complications. 展开更多
关键词 high-frequency electric surgical knives Abdominal incision HEALING INFECTION
下载PDF
High performance electrocoagulation process in treating palm oil mill effluent using high current intensity application 被引量:2
15
作者 Mohd Nasrullah A.W.Zularisam +3 位作者 Santhana Krishnan Mimi Sakinah Lakhveer Singh Yap Wing Fen 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第1期208-217,共10页
Electrocoagulation process using high current intensity to treat palm oil mill effluent(POME) was investigated in this study.Various operating parameters such as electrolysis time, inter-electrode distance and initial... Electrocoagulation process using high current intensity to treat palm oil mill effluent(POME) was investigated in this study.Various operating parameters such as electrolysis time, inter-electrode distance and initial pH were carried out to determine the efficient process condition on the removal of chemical oxygen demand(COD),biological oxygen demand(BOD) and suspended solids(SS).The highest treatment was achieved at 50 min with the removal efficiencies for COD, BOD and SS obtained as 85%, 83%, and 84%, respectively.More than 50 min treatment showed the fluctuated trends of removal efficiencies which can be considered insignificant.The application of higher current resulted in higher removals of organics while the gas bubbles also assisted in removing the pollutant particles by floatation.In an inter-electrode distance study, the removal efficiency decreased when inter-electrode distance was either higher or lower than 10 mm due to the increase of solution resistance and the decrease of anode active surface area.In initial pH study, it was found that high removal efficiencies were achieved in slightly acidic POME sample rather than in neutral or basic condition.An electrocoagulation process by using the optimum operating parameters was able to remove COD, BOD and SS up to 95%, 94% and 96% respectively.The experimental results confirm that application of high current intensity in electrocoagulation provided high treatment efficiency at a reduced reaction time. 展开更多
关键词 ELECTROCHEMISTRY Environment electrocoagulation PALM oil MILL EFFLUENT High current INTENSITY
下载PDF
Phenol Removal from Aqueous Solutions by Electrocoagulation Technology Using Iron Electrodes:Effect of Some Variables 被引量:3
16
作者 Mohammad Ali Zazouli Mahmoud Taghavi 《Journal of Water Resource and Protection》 2012年第11期980-983,共4页
The aim of this study was to determine the effect of electrocoagulation technology using iron electrodes on phenol removal in aqueous solutions. The removal of phenol was investigated in terms of various parameters, n... The aim of this study was to determine the effect of electrocoagulation technology using iron electrodes on phenol removal in aqueous solutions. The removal of phenol was investigated in terms of various parameters, namely, current density, phenol and NaCl concentration, pH, and alginic acid concentration. The results showed that the removal efficiency of phenol increased with increasing the current density, pH and NaCl concentration, whereas it was inversely associated with initial concentration of phenol and alginic acid concentration. According to the results, electrocoagulation is a promising process for treatment of wastewater containing high concentration of phenol. 展开更多
关键词 PHENOL electrocoagulation WATER Treatment WATER POLLUTION
下载PDF
The diagnostic value of high-frequency ultrasonography in biliary atresia 被引量:13
17
作者 Li-Ping Jiang Yun-Chao Chen +5 位作者 Lu Ding Xiao-Ling Liu Kai-Yan Li Dao-Zhong Huang Ai-Yun Zhou Qing-Ping Zhang 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2013年第4期415-422,共8页
BACKGROUND: It is a globally challenging problem to differentially diagnose biliary atresia (BA) from other disease processes causing infantile cholestatic jaundice. The high frequency ultrasonography (HUS) yields muc... BACKGROUND: It is a globally challenging problem to differentially diagnose biliary atresia (BA) from other disease processes causing infantile cholestatic jaundice. The high frequency ultrasonography (HUS) yields much improved spatial resolution and therefore, might show better image in BA diagnostic examination. The present study was to evaluate the HUS on the diagnosis of BA in infants with jaundice. METHODS: Fifty-one infants with neonatal jaundice were scanned with ultrasonography. Images included gallbladder, bile duct, right hepatic artery (RHA), portal vein (PV) and triangular cord (TC) sign, magnetic resonance imaging and additionally laboratory tests and histopathology reports were assessed. RESULTS: Twenty-three BA and 28 non-BA cases were con firmed. The sensitivity, specificity, and accuracy of HUS were 91.3%, 92.9%, and 92.2%, respectively. All of these indices were significantly higher than those of conventional ultrasonography (P【0.01) and MR cholangiopancreatography (P【0.05). The HUS features, included a positive TC sign, an increased RHA diameter and RHA-diameter to portal-vein-diameter ratio (RHA/PV) and abnormal gallbladder, were important in the diagnosis of BA. CONCLUSION: HUS provided better imaging of BA and should be considered as a primary modality in the differential diagnosis of infantile jaundice. 展开更多
关键词 neonatal jaundice biliary atresia high-frequency ultrasonography
下载PDF
Present Status and Prospect of High-Frequency Electro-hydraulic Vibration Control Technology 被引量:7
18
作者 Yi Liu Tao Wang +1 位作者 Guofang Gong Rujun Gao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2019年第6期1-16,共16页
Electro-hydraulic vibration equipment(EHVE)is widely used in vibration environment simulation tests,such as vehicles,weapons,ships,aerospace,nuclear industries and seismic waves replication,etc.,due to its large outpu... Electro-hydraulic vibration equipment(EHVE)is widely used in vibration environment simulation tests,such as vehicles,weapons,ships,aerospace,nuclear industries and seismic waves replication,etc.,due to its large output power,displacement and thrust,as well as good workload adaptation and multi-controllable parameters.Based on the domestic and overseas development of high-frequency EHVE,dividing them into servo-valve controlled vibration equipment and rotary-valve controlled vibration equipment.The research status and progress of high-frequency electro-hydraulic vibration control technology(EHVCT)are discussed,from the perspective of vibration waveform control and vibration controller.The problems of current electro-hydraulic vibration system bandwidth and waveform distortion control,stability control,offset control and complex vibration waveform generation in high-frequency vibration conditions are pointed out.Combining the existing rotary-valve controlled high-frequency electro-hydraulic vibration method,a new twin-valve independently controlled high-frequency electro-hydraulic vibration method is proposed to break through the limitations of current electro-hydraulic vibration technology in terms of system frequency bandwidth and waveform distortion.The new method can realize independent adjustment and control of vibration waveform frequency,amplitude and offset under high-frequency vibration conditions,and provide a new idea for accurate simulation of high-frequency vibration waveform. 展开更多
关键词 Electro-hydraulic vibration equipment high-frequency Vibration control Vibration waveform Twin-valve
下载PDF
High-frequency atmospheric variability over South China Sea as depicted by TRMM and QuikSCAT 被引量:6
19
作者 LI Weibiao WANG Dong xiao +2 位作者 LEI Ting LIU Zijie LU0 Cong 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2011年第2期46-52,共7页
By using the TRMM and QuikSCAT datathe characteristics of the 2–8 day high frequency atmospheric variability over the South China Sea are studied in this paper.It’s found that: (1) the 2–8 day high frequency sig... By using the TRMM and QuikSCAT datathe characteristics of the 2–8 day high frequency atmospheric variability over the South China Sea are studied in this paper.It’s found that: (1) the 2–8 day high frequency signals are significant not only during the periods of the South China Sea Summer Monsoon (SCSSM),but also after the retreat of the SCSSM.It reaches its peak around July to August;(2) the 2–8 day high frequency signals exhibit strong intermittent features;(3) During El Nino years,the 2–8 day high frequency signals are active only in the periods of the SCSSM.During La Nina years,the 2–8 day high frequency signals are obviously not only in periods of the SCSSM,but also after the retreat of the SCSSM.During the SCSSM periods,the 2–8 day high frequency signals in El Nino years are much stronger than that in La Nina years;(4) During spring to early summer,most of 2–8 day signals propagate southward and eastward,during midsummer to autumn,however,most of 2–8-day signals propagate northward and westward;(5) The 2–8 day northward and westward propagation signals is probably related to the activities of high-frequency vortex over the SCS. 展开更多
关键词 high-frequency atmospheric variability South China Sea TRMM QUIKSCAT
下载PDF
High total Joule heat increases the risk of post-endoscopic submucosal dissection electrocoagulation syndrome after colorectal endoscopic submucosal dissection 被引量:3
20
作者 Masanori Ochi Ryosuke Kawagoe +8 位作者 Toshiro Kamoshida Yukako Hamano Haruka Ohkawara Atsushi Ohkawara Nobushige Kakinoki Yuji Yamaguchi Shinji Hirai Akinori Yanaka Kiichiro Tsuchiya 《World Journal of Gastroenterology》 SCIE CAS 2021年第38期6442-6452,共11页
BACKGROUND We hypothesized that thermal damage accumulation during endoscopic submucosal dissection(ESD)causes the pathogenesis of post-ESD electrocoagulation syndrome(PECS).AIM To determine the association between Jo... BACKGROUND We hypothesized that thermal damage accumulation during endoscopic submucosal dissection(ESD)causes the pathogenesis of post-ESD electrocoagulation syndrome(PECS).AIM To determine the association between Joule heat and the onset of PECS.METHODS We performed a retrospective cohort study in patients who underwent colorectal ESD from May 2013 to March 2021 in Japan.We developed a novel device that measures swift coagulation time with a sensor adjacent to the electrosurgical coagulation unit foot switch,which enabled us to calculate total Joule heat.PECS was defined as localized abdominal pain(visual analogue scale≥30 mm during hospitalization or increased by≥20 mm from the baseline)and fever(temperature≥37.5 degrees or white blood cell count≥10000μ/L).Patients exposed to more or less than the median Joule heat value were assigned to the high and low Joule heat groups,respectively.Statistical analyses included Mann-Whitney U and chisquare tests and logistic regression and receiver operating characteristic curve(ROC)analyses.RESULTS We evaluated 151 patients.The PECS incidence was 10.6%(16/151 cases),and all patients were followed conservatively and discharged without severe complications.In multivariate analysis,high Joule heat was an independent PECS risk factor.The area under the ROC curve showing the correlation between PECS and total Joule heat was high[0.788(95%confidence interval:0.666-0.909)].CONCLUSION Joule heat accumulation in the gastrointestinal wall is involved in the onset of PECS.ESD-related thermal damage to the peeled mucosal surface is probably a major component of the mechanism underlying PECS. 展开更多
关键词 Post-endoscopic submucosal dissection electrocoagulation syndrome Joule heat Colorectal endoscopic submucosal dissection Colorectal neoplasms electrocoagulation Gastrointestinal tract
下载PDF
上一页 1 2 79 下一页 到第
使用帮助 返回顶部