期刊文献+
共找到1,099篇文章
< 1 2 55 >
每页显示 20 50 100
Sutured scleral fixation of existing subluxated/dislocated acrylic one-piece intraocular lenses
1
作者 Wei-Yu Huang Yung-Jen Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期665-669,共5页
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ... AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications. 展开更多
关键词 intraocular lens dislocation intraocular lens subluxation lens dislocation lens subluxation scleral fixation
下载PDF
Effectivity and safety of trifocal intraocular lenses and capsular tension rings implantation for cataract patients with axial high myopia
2
作者 Shan Hua Qiu-Xia Xie +1 位作者 Hu Wang Jing-Xiang Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期499-508,共10页
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria... ●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications. 展开更多
关键词 trifocal intraocular lenses capsular tension ring axial high myopia CATARACT visual quality
下载PDF
Changes in visual performance after implantation of different intraocular lenses
3
作者 Bo-Wen Li Hao Huang +10 位作者 Man-Sha Huang Shuang-Lin Guo Lu Gao Yu-Ying Zeng Lu Cheng Si-Yang Yao Jian-Qiang Lin Lin Liu Ye Yang Xiao-Ming Lu Hao Cheng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1273-1282,共10页
AIM:To evaluate the trending visual performance of different intraocular lenses(IOLs)over time after implantation.METHODS:Ninety-one patients received cataract surgery with implantations of monofocal(Mon)IOLs,segmenta... AIM:To evaluate the trending visual performance of different intraocular lenses(IOLs)over time after implantation.METHODS:Ninety-one patients received cataract surgery with implantations of monofocal(Mon)IOLs,segmental refractive(SegRef)IOLs,diffractive(Dif)IOLs,and extendeddepth-of-focus(EDoF)IOLs were included.The aberrations and optical quality collected with iTrace and OQAS within postoperative 6mo were followed and compared.RESULTS:Most of the visual parameters improved over the postoperative 6mo.The postoperative visual acuity(POVA)of the Mon IOL,SegRef IOL,and EDoF IOL groups achieved relative stability in earlier states compared with the Dif IOL group.Nevertheless,the overall visual performance of the 3 IOLs continued to upturn in small extents within the postoperative 6mo.The optical quality initially improved in the EDoF IOL group,then in the Mon IOL,SegRef IOL,and Dif IOL groups.POVA and objective visual performance of the Mon IOL and EDoF IOL groups,as well as POVA and visual quality of the Dif IOL group,improved in the postoperative 1mo and stabilized.Within the postoperative 6mo,gradual improvements were observed in the visual acuity and objective visual performance of the SegRef IOL group,as well as in the postoperative optical quality of the Dif IOL group.CONCLUSION:The visual performance is different among eyes implanted with different IOLs.The findings of the current study provide a potential reference for ophthalmologists to choose suitable IOLs for cataract patients in a personalized solution. 展开更多
关键词 intraocular lenses visual performance changing characteristics high-order wavefront aberration
下载PDF
Intraocular lens selection in diabetic patients:How to increase the odds for success
4
作者 Arvind Kumar Morya Prateek Nishant +4 位作者 Prasanna Venkatesh Ramesh Sony Sinha Aarti Heda Sarika Salodia Ripunjay Prasad 《World Journal of Diabetes》 SCIE 2024年第6期1199-1211,共13页
The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract sur... The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract surgery in diabetic patients poses many challenges:Poor epithelial healing,decreased corneal sensitivity,increased central corneal thickness,decreased endothelial cell count,variable topography,poor pupillary dilatation,anterior capsular phimosis,posterior capsular opacification(PCO),chances of progression of diabetic retinopathy(DR),zonular weakness,and vitreous prolapse and diabetic macular edema.Selection of an appropriate intraocular lens(IOL)is crucial for visual rehabilitation and monitoring DR.The choice of IOL in diabetic cataract patients is a challenging scenario.Square-edge IOLs are favored for their capacity to mitigate PCO,whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR.The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation,particularly in the presence of advanced retinopathy.Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications.Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes.This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population. 展开更多
关键词 DIABETICS CATARACT intraocular lens Diabetic retinopathy Diabetes mellitus
下载PDF
Clinical Effect Analysis of Posterior Chamber Intraocular Lens Implantation for Correcting High Myopia and Astigmatism
5
作者 Bo Xia Dan Dan Zhao 《Journal of Clinical and Nursing Research》 2024年第8期99-104,共6页
Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the ca... Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety. 展开更多
关键词 Posterior chamber intraocular lens implantation in phakic eyes High myopia ASTIGMATISM Corrective effect
下载PDF
Flapless one-knot suture:a novel surgical technique for transscleral fixation of C-loop intraocular lenses
6
作者 Qing-Qing Long Bao-Jiang Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第5期736-742,共7页
AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectiv... AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectively analyzed 16 eyes of 16 patients who underwent transscleral fixation of C-loop PCIOLs using a flapless one-knot suture technique,which were followed up for longer than 17mo.In this technique,the capsulorless IOL was suspended using a single suture for transscleral fixation of four feet.Then we compared its surgical outcomes and complications with the four-haptics PC-IOLs using the Student's t test and Chi-square test.RESULTS:Sixteen patients of 16 eyes with a mean age of 58.3±10.1y(42-76y)who received transscleral C-loop IOL implantation due to trauma,vitrectomy,or cataract surgery with inadequate capsule support showed improved visual acuity.The difference was not significant between two IOLs except the surgery time(P>0.05).The mean operation times of C-loop IOL surgery was 24.1±1.83min and 31.3±4.47min of the four-haptics PC-IOL method(P<0.0001).In the C-loop IOLs group,there was statistical difference between the preoperative and the postoperative UCVA(log MAR,1.20±0.50 vs 0.57±0.32,P=0.0003).There was no statistical difference between the preoperative and the postoperative BCVA(log MAR,0.66±0.46 vs 0.40±0.23,P=0.056).However,there was no statistically significant difference in postoperative UCVA and BCVA between the two IOLs(P>0.05).We did not detect any optic capture,IOL decentration or dislocation,suture exposed,or cystoid macular edema in patients underwent C-loop IOLs surgery.CONCLUSION:The novel flapless one-knot suture technique for transscleral fixation of C-loop IOL is a simple,reliable,and stable technique. 展开更多
关键词 C-loop intraocular lens implantation lens dislocation transscleral fixation four-haptics intraocular lens
下载PDF
Rotational stability of plate haptic toric intraocular lenses after combined 25-gauge vitrectomy and cataract surgery 被引量:1
7
作者 Lara Buhl Julian Langer +3 位作者 Stefan Kassumeh Thomas C.Kreutzer Wolfgang J.Mayer Siegfried G.Priglinger 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1231-1236,共6页
AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL... AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.METHODS:In this retrospective case series,32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter(D).A plate haptic toric IOL(AT Torbi 709M,Carl Zeiss Meditec AG)was implanted in all eyes.The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity(BCVA).RESULTS:Preoperative refractive astigmatism was 2.14±1.17 D,which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period(0.67±0.44 D at three months and 0.75±0.25 D at six months;for all groups:P<0.0001 compared to baseline).BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery(P=0.02).Mean IOL axis deviation from the target axis was 3.4°±2.9°after six to eight weeks and significantly decreased over time(2.4°±2.6°six months after surgery;P=0.04).In one patient IOL,re-alignment was performed.CONCLUSION:Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.The plate haptic toric IOL position and axis remain stable during the observation period of six months. 展开更多
关键词 combined phaco-vitrectomy toric intraocular lens rotational stability corneal astigmatism CATARACT vitreoretinal disease
下载PDF
A new software for automated counting of glistenings in intraocular lenses in vivo
8
作者 Nick Stanojcic Christopher C.Hull +2 位作者 Eduardo Mangieri Nathan Little David O’Brart 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1237-1242,共6页
AIM:To assess the performance of a bespoke software for automated counting of intraocular lens(IOL)glistenings in slit-lamp images.METHODS:IOL glistenings from slit-lamp-derived digital images were counted manually an... AIM:To assess the performance of a bespoke software for automated counting of intraocular lens(IOL)glistenings in slit-lamp images.METHODS:IOL glistenings from slit-lamp-derived digital images were counted manually and automatically by the bespoke software.The images of one randomly selected eye from each of 34 participants were used as a training set to determine the threshold setting that gave the best agreement between manual and automatic grading.A second set of 63 images,selected using randomised stratified sampling from 290 images,were used for software validation.The images were obtained using a previously described protocol.Software-derived automated glistenings counts were compared to manual counts produced by three ophthalmologists.RESULTS:A threshold value of 140 was determined that minimised the total deviation in the number of glistenings for the 34 images in the training set.Using this threshold value,only slight agreement was found between automated software counts and manual expert counts for the validating set of 63 images(κ=0.104,95%CI,0.040-0.168).Ten images(15.9%)had glistenings counts that agreed between the software and manual counting.There were 49 images(77.8%)where the software overestimated the number of glistenings.CONCLUSION:The low levels of agreement show between an initial release of software used to automatically count glistenings in in vivo slit-lamp images and manual counting indicates that this is a non-trivial application.Iterative improvement involving a dialogue between software developers and experienced ophthalmologists is required to optimise agreement.The results suggest that validation of software is necessary for studies involving semi-automatic evaluation of glistenings. 展开更多
关键词 new software automated counting glistenings intraocular lenses slit-lamp images
下载PDF
Pupillary capture following sutureless scleral-fixated intraocular lens in children with Marfan syndrome
9
作者 Dong-Mei Qi Shu-Jia Huo Tao Yu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第11期1789-1793,共5页
AIM:To compare the clinical outcomes between two approaches for sutureless scleral-fixated intraocular lens(SFIOL)in children with Marfan syndrome(MFS).METHODS:The study included 15 children(26 eyes)with lens subluxat... AIM:To compare the clinical outcomes between two approaches for sutureless scleral-fixated intraocular lens(SFIOL)in children with Marfan syndrome(MFS).METHODS:The study included 15 children(26 eyes)with lens subluxation due to MFS.These children underwent lensectomy,anterior vitrectomy,and sutureless SFIOL.According to the position of placement of intraocular lens(IOL)haptics,two study groups were reviewed for best corrected visual acuity(BCVA)and postoperative complications:group A,14 eyes with haptics fixated at 2.0 mm from the limbus;group B,12 eyes with the haptics fixated at 2.5 mm from the limbus.RESULTS:The mean axial length for all patients was 25.66±2.35 mm.Postoperative BCVA in logMAR were significant improved in both groups(0.77±0.32 to 0.17±0.12 in group A,0.66±0.25 to 0.24±0.12 in group B,both P<0.001)while no significant difference between two groups(P>0.05).Pupillary capture was main postoperative complication,occurring between 3d and 18mo.It occurred in 7 eyes in group A and one eye in group B(P=0.02).CONCLUSION:Sutureless SFIOL is an effective treatment approach for lens subluxation in children with MFS.Pupillary capture is the main postoperative complication.Fixated IOL haptics at 2.5 mm from the limbus can reduce the occurrence of pupillary capture. 展开更多
关键词 Marfan syndrome sutureless scleral-fixated intraocular lens pupillary capture CHILDREN
下载PDF
Considerations in the management of single-piece intraocular lenses outside the capsular bag
10
作者 Anna K Junk 《World Journal of Ophthalmology》 2014年第3期87-91,共5页
AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who... AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who received sulcus-placed SPA-IOLs between 2006 and 2009 were reviewed. None of the patients underwent IOL exchange. Charts of six age-matched patients who received sulcus placed 3P-IOLs were reviewed as a control group. RESULTS: Mean follow up was 16 mo for SPA-IOL and 23 mo for 3P-IOL. Five of 8 patients in the SPA-IOL group required chronic use of IOP lowering medications at final follow up. Of these, one patient needed glaucoma implant surgery for uncontrolled IOP. One patient in the 3P-IOL group used chronic aqueous suppression pre- and postoperatively. Four of eight eyes with SPAIOL were treated with chronic topical steroids and or non-steroidal anti-inflammatory drugs for cystoid macu-la edema, chronic uveitis, pigment dispersion syndrome or a combination of the above, compared to none in the control group. Mean best-corrected visual acuity was 20/35 in the SPA-IOL group and 20/47 in the 3PIOL group.CONCLUSION: Sulcus placed SPA-IOLs are associated with increased ocular morbidity. In select cases good visual acuity may be achieved. Due to postoperative rotation of sulcus placed toric SPA-IOLs stable astigmatism correction cannot be achieved. Alternative intraocular lenses should be considered when in-the-bag placement of SPA-IOL is not possible. 展开更多
关键词 Cataract surgery Sulcus intraocular lens implant Single piece intraocular lenses Three piece intraocular lenses Posterior capsule tear Cataract surgery complication Pigment dispersion Cystoid macula edema Anterior vitrectomy
下载PDF
Combined pars plana vitrectomy and suture less scleral fixation of foldable intraocular lens:single surgery visual rehabilitation of dislocated lens/intraocular lens
11
作者 Brijesh Takkar Shorya Vardhan Azad +2 位作者 Neelima Aron Ravi Bypareddy Rajvardhan Azad 《Annals of Eye Science》 2017年第1期90-96,共7页
Background:To evaluate efficacy and safety of combined pars plana vitrectomy(PPV)and scleral fixated intraocular lens(SFIOL)surgery as a single procedure.Methods:Retrospective interventional case series done at a tert... Background:To evaluate efficacy and safety of combined pars plana vitrectomy(PPV)and scleral fixated intraocular lens(SFIOL)surgery as a single procedure.Methods:Retrospective interventional case series done at a tertiary eye care center in Northern India.Eleven patients who underwent combined PPV and SFIOL surgery were included and analyzed retrospectively.Results:Mean age of the patients was 43.36±15.12 years(range,22-64 years).Eight were male.Mean baseline best corrected visual acuity(BCVA)was 0.78±0.63 logMAR units while the mean post-operative BCVA at 6 months follow-up was 0.37±0.29 logMAR units,the visual gain being statistically significant(P=0.021).None of the patients had a drop in BCVA with nine patients having final BCVA better than 0.48 logMAR units.Choroidal detachment(CD)was the only notable complication,seen in three patients.Other complications included two cases of intraoperative retinal breaks,a case each of reversible corneal edema,ocular hypertension and cystoid macular edema.Conclusions:Combined PPV and SFIOL is an efficacious procedure for managing IOL/lens dislocation and aphakia in a single surgery.There may be short-term reversible complications with no impact on final visual gain. 展开更多
关键词 Pars plana vitrectomy(PPV) intraocular lens(IOL) posterior segment anterior segment surgery intraocular lens implantation(IOL implantation) intraocular lens surgery(IOL surgery) lens surgery
下载PDF
Multifocal and extended depth of focus intraocular lenses
12
作者 Georgios Kondylis Olga Klavdianou Sotiria Palioura 《Annals of Eye Science》 2019年第1期13-18,共6页
Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number... Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number of focal points that each lens provides,which in turn leads to different visual outcomes.Familiarity of surgeons with the various characteristics of each lens is of utmost importance for accurate IOL selection to match each patient’s needs.In this review,we aim to compare the clinical outcomes after implantation of multifocal and EDOF IOLs in terms of distance,intermediate and near vision,contrast sensitivity,and reading performance.Finally,we discuss the defocus curve and the optical and photic phenomena associated with each type of IOL. 展开更多
关键词 Cataract surgery quality of vision intraocular lens implantation trifocal intraocular lens bifocal intraocular lens
下载PDF
Visual function and higher order aberration after implantation of aspheric and spherical multifocal intraocular lenses:a meta-analysis 被引量:6
13
作者 Jian-Ping Liu Fan Zhang +2 位作者 Jiang-Yue Zhao Li-Wei Ma Jin-Song Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期690-695,共6页
AIMTo assess the visual outcomes of aspheric multifocal intraocular lenses (IOLs) compared with spherical multifocal IOL after cataract surgery.
关键词 aspheric multifocal intraocular lens uncorrected near visual acuity uncorrected distance visual acuity spherical multifocal intraocular lens higher order aberration META-ANALYSIS
下载PDF
Postoperative visual performance with a bifocal and trifocal diffractive intraocular lens during a 1-year follow-up 被引量:6
14
作者 Peter Mojzis Lucia Kukuckova +2 位作者 Katarina Majerova Peter Ziak David P.Pi?ero 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第10期1528-1533,共6页
AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL)during a 12-month follow-up.METHODS:Prospective comparative study including75 eyes of 38 patients(44-... AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL)during a 12-month follow-up.METHODS:Prospective comparative study including75 eyes of 38 patients(44-70y)undergoing uneventful cataract surgery.Each patient was randomly assigned to one type of IOL,bifocal(35 eyes)or trifocal(40 eyes).Visual,refractive,and contrast sensitivity changes were evaluated in a 12-month follow-up.The binocular defocus curve was also measured at 12mo postoperatively.RESULTS:No statistically significant differences between groups were found in postoperative uncorrected and corrected distance visual acuities(P≥0.276).Postoperative corrected near visual acuity(33 cm)was significantly better in the trifocal group during all follow-up(P≤0.004)as well as 6-month uncorrected near(P=0.008)and distancecorrected near visual acuities(P=0.016)(33/40 cm).Significantly better uncorrected intermediate and distance corrected-intermediate visual acuity were found during all follow-up in the trifocal group(P〈0.001),which was consistent with differences among groups in binocular defocus curve.Differences among groups in contrast sensitivity were minimal,being only significant at 6 months for some low to medium spatial frequencies(P≤0.006).CONCLUSION:Bifocal and trifocal diffractive IOLs are able to provide an effective visual restoration which is maintained during a 12-month follow-up,with a clear benefit of the trifocal IOL for the intermediate vision. 展开更多
关键词 trifocal intraocular lens bifocal intraocular lens defocus curve contrast sensitivity cataract surgery
下载PDF
Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens 被引量:5
15
作者 Jing Zhao Liang-Ping Liu +4 位作者 Huan-Huan Cheng Jian-Bing Li Xiao-Tong Han Yu Liu Ming-Xing Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第9期1378-1384,共7页
AIM:To evaluate the accuracy of eight different intraocular lens(IOL)power calculation formulas for a segmented multifocal IOL.METHODS:A total of 53 eyes of 41 adult cataract patients who underwent phacoemulsification... AIM:To evaluate the accuracy of eight different intraocular lens(IOL)power calculation formulas for a segmented multifocal IOL.METHODS:A total of 53 eyes of 41 adult cataract patients who underwent phacoemulsification and implantation with the SBL-3 segmented multifocal IOL between January 1,2017 and January 31,2019 were included in this retrospective study.Preoperative biometry measurements were obtained using an IOL Master.Manifest refraction was performed at least 4 wk postoperatively.Accuracy of the eight formulas[Barrett Universal II,Emmetropia Verifying Optical(EVO),Haigis,Hill-RBF 2.0,Hoffer Q,Holladay 1,Kane,and SRK/T]was analyzed.RESULTS:Using current lens constants,all formulas exhibited errors of slight myopic shift in refractive prediction.The Barrett Universal II formula had a significantly lower median absolute error(MedAE)than did Holladay 1(P=0.02),Kane(P=0.001)and Hill-RBF 2.0(P<0.001)formulas.The Haigis formula had a lower MedAE value than did the Hill-RBF 2.0 formula(P=0.005).Differences in MedAE values among SRK/T,EVO and Hoffer Q formulas were not significant.After optimizing lens constants,the MedAE values of all formulas were reduced;significant changes were noted for EVO(P=0.022),Haigis(P=0.048);Hill-RBF 2.0(P=0.014),Holladay 1(P=0.045)and Kane(P=0.022)formulas.All formulas performed equally well after optimization of lens constants(P=0.203).CONCLUSION:All eight formulas tend to result in a myopic shift when using current lens constants.Optimized lens constants improve the accuracy of these formulas among adult Chinese patients. 展开更多
关键词 ACCURACY intraocular lens formulas lens constants segmented multifocal intraocular lens
下载PDF
Comparison of trifocal toric and bifocal toric intraocular lens implantation in patients with cataract and high corneal astigmatism 被引量:2
16
作者 Merve Bozkurt Gencer Hikmet Basmak +1 位作者 Erdogan Yasar Ozkan Onal 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第12期1876-1881,共6页
AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A t... AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A total of 80 eyes of 40 patients were included in this prospective study.Twenty patients in each group were implanted with trifocal toric and bifocal toric IOL,respectively.Preoperative and postoperative 6-month measurements were recorded for both patient groups.Comprehensive anterior and posterior segment examinations,distance-intermediate-near visual acuity values and the visual function scale questionnaire results were evaluated at these examinations.Patient satisfaction,contrast sensitivity,glare,intermediate-near and distance stereopsis and IOL rotation were also evaluated.RESULTS:No significant difference was found between the groups in terms of distance and near visual acuities(P=0.269,P=0.451).Intermediate visual acuity was significantly increased in the trifocal toric group(P<0.001).The visual function scale results were increased after surgery in both groups(P=0.001 and P<0.001),with no difference determined between them(P=0.158 and P=0.691).The number of patients wearing glasses was low in both groups and there was no significant difference between the groups(P>0.05).The overall satisfaction in the trifocal toric group was significantly higher than in the bifocal toric group(P=0.03).The highest sensitivity was observed at 6 cpd spatial frequency in all patients under photopic conditions(1.80±0.24 logU,1.74±0.20 logU).Distance-intermediate-near binocular depth perception results in both groups were higher in the trifocal toric group(P=0.02,0.048,0.003,respectively).Although there was no significant difference for 3 meters stereopsis,the trifocal toric group had higher depth perception(P=0.577).Mean rotation was 5.76°±3.93°in the trifocal toric group and 12°±7.1°in the bifocal toric group.CONCLUSION:Better results in the middle distance are obtained in the trifocal toric group and less IOL rotation due to digital system-coordinated surgery.Moreover,the overall satisfaction in the trifocal toric group is significantly higher than in the bifocal toric group. 展开更多
关键词 CATARACT trifocal toric intraocular lens bifocal toric intraocular lens STEREOPSIS SATISFACTION
下载PDF
Hydrophobic versus hydrophilic acrylic intraocular lens on posterior capsule opacification: a Meta-analysis 被引量:2
17
作者 Qiong Wu Yan Li +1 位作者 Lian Wu Cong-Yi Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第6期997-1004,共8页
AIM: To conduct a Meta-analysis pooling randomized controlled trials(RCTs) to compare hydrophobic with hydrophilic acrylic intraocular lenses in terms of posterior capsule opacification(PCO) development.METHODS: Elect... AIM: To conduct a Meta-analysis pooling randomized controlled trials(RCTs) to compare hydrophobic with hydrophilic acrylic intraocular lenses in terms of posterior capsule opacification(PCO) development.METHODS: Electronic databases including PubMed,Embase, and the Cochrane Library were queried from their starting till January 2020. RCTs investigating the impact of hydrophobic versus hydrophilic acrylic intraocular lenses on PCO were considered eligible in this study. The pooled effect estimates were calculated using the random-effects model.RESULTS: Thirteen RCTs comprising of 939 patients(1263 eyes) were covered in this study. Patients with hydrophobic acrylic intraocular lenses had a lower PCO score than those with a hydrophilic acrylic intraocular lenses [standard mean difference:-1.80;95% confidence interval(CI):-2.62 to-0.98;P<0.001]. Moreover, the frequency of neodymium-doped yttrium aluminum garnet(Nd:YAG)capsulotomy in patients with hydrophobic acrylic intraocular lenses was significantly lower than patients with hydrophilic acrylic intraocular lenses(relative risk: 0.38;95%CI: 0.20-0.71;P=0.003).CONCLUSION: These findings suggest that hydrophobic acrylic intraocular lenses are superior to hydrophilic acrylic intraocular lenses in patients after cataract surgery due to lower PCO score and reduced Nd:YAG capsulotomy. While similar studies are conducted by other researchers, the present study conducted subgroup analyses that show superior results with hydrophobic lenses in trials conducted in western countries. 展开更多
关键词 hydrophobic acrylic intraocular lens hydrophilic acrylic intraocular lens posterior cataract opacification Nd:YAG capsulotomy META-ANALYSIS
下载PDF
Comparative analysis of visual quality between unilateral implantation of a trifocal intraocular lens and a rotationally asymmetric refractive multifocal intraocular lens 被引量:1
18
作者 Na Hui Mei-Fang Chu +3 位作者 Yan Li Cong-Yi Wang Lei Yu Bo Ma 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第9期1460-1467,共8页
·AIM:To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens(IOL)and asymmetric refractive multifocal IOL.·METHODS:The prospective nonrandom,comparative stu... ·AIM:To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens(IOL)and asymmetric refractive multifocal IOL.·METHODS:The prospective nonrandom,comparative study consisted of 60 eyes of 60 patients suffering unilateral cataract surgery with implantation of two different IOLs:AT LISA tri 839 MP(30 eyes;Carl Zeiss Meditec,Germany)and LS-313 MF30(30 eyes;Oculentis GmbH,Germany).Visual acuity,refractive outcome,contrast sensitivity,defocus curves,quality of vision,and optical phenomena were evaluated at3 mo postoperatively.·RESULTS:There were no statistical differences between groups in uncorrected distance visual acuity(P=0.13)and uncorrected near visual acuity(P=0.54).In contrast,uncorrected intermediate visual acuity was better in trifocal group compared to the refractive multifocal group(P=0.02).No significant statistical between-group difference was detected in cylinder(P=0.43).Compared to trifocal group,spherical refraction and spherical equivalent in refractive multi focal group were more myopic(P<0.01).Under photopic conditions,no significant statistical differences were found between groups in contrast sensitivity at 3 and 6 cycles per degree(cpd).The refractive multifocal group performed better at 12 and 18 cpd than the trifocal group(P=0.01,P=0.034,respectively).The questionnaires of quality of vision and optical phenomena showed no differences between groups.·CONCLUSION:Trifocal IOL is superior to refractive multifocal IOL in intermediate visual acuity.Rotationally asymmetric refractive multifocal IOL is more myopic in automated refraction and significantly better for the photopic contrast sensitivity at high frequency. 展开更多
关键词 trifocal intraocular lens rotationally asymmetric multifocal intraocular lens visual quality contrast sensitivity
下载PDF
Encouraging Visual Outcome of a New Accommodative Intraocular Lens: A Retrospective Long-Term Study with a Mean Follow-Up of 5.3 Years
19
作者 Jacob Ritter Justus Petrick +2 位作者 Anna-Lena Kloberdanz Charlotte Rammler Violeta Doci 《Open Journal of Ophthalmology》 2022年第4期416-429,共14页
Purpose: To assess the visual outcome after implantation of the new Hydrophylic IOL type 41 B/G accommodating intraocular lens (AIOL). Methods: The presented lens was implanted during cataract surgery. All patients we... Purpose: To assess the visual outcome after implantation of the new Hydrophylic IOL type 41 B/G accommodating intraocular lens (AIOL). Methods: The presented lens was implanted during cataract surgery. All patients were offered follow-ups, allowing two postoperative measurements to be performed at 3 months and between 2020 and 2021. The mean time between lens implantation and last follow-up was 5.3 years (min. 1 year, max. 10 years). Excluded were patients with age-related macular degeneration or amblyopia. Patients with a foreign lens implanted into the second eye were included in a separate control group. Corrected distance (CDVA) and uncorrected distance visual acuity (UDVA) at 5 m, and corrected near (CNVA) and uncorrected near visual acuity (UNVA) at 40 cm were assessed. Furthermore, the postoperative spherical equivalent (SE), the dependence on spectacles and the occurrence of optical phenomena were evaluated. Results: The final study cohort consists of 65 patients with 119 implanted AIOLs. Significantly better visual results were obtained in both postoperative follow-ups compared with the preoperative results. The mean values of the last follow-up for the UNVA, CNVA, UDVA, and CDVA were 0.107 ± 0.10;0.039 ± 0.08;0.097 ± 0.11;and 0.040 ± 0.09 logMAR, respectively. Visual outcomes remained on a high level for up to 10 years and showed significantly better results compared to the control group. Postoperative SE was significantly improved. Nearly 70% of patients were no longer dependent on glasses. Furthermore, the occurrence of disturbing optical phenomena was denied by all patients. Conclusion: The results of this AIOL are particularly promising, especially since gratifying visual results could still be measured 10 years after implantation. 展开更多
关键词 Accommodative intraocular lens Cataract Surgery Monofocal intraocular lens Visual Acuity
下载PDF
Predictive factors for photic phenomena after refractive,rotationally asymmetric,multifocal intraocular lens implantation 被引量:16
20
作者 Hungwon Tchah Kiyeun Nam Aeri Yoo 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第2期241-245,共5页
AIM: To investigate the independent factors associated with photic phenomena in patients implanted with refractive,rotationally asymmetric,multifocal intraocular lenses(MIOLs).METHODS: Thirty-four eyes of 34 patie... AIM: To investigate the independent factors associated with photic phenomena in patients implanted with refractive,rotationally asymmetric,multifocal intraocular lenses(MIOLs).METHODS: Thirty-four eyes of 34 patients who underwent unilateral cataract surgery,followed by implantation of rotationally asymmetric MIOLs were included.Distance and near visual acuity outcomes,intraocular aberrations,preferred reading distances,preoperative and postoperative refractive errors,mesopic and photopic pupil diameters,and the mesopic and photopic kappa angles were assessed.Patients were also administered a satisfaction survey.Photic phenomena were graded by questionnaire.Independent-related factors were identified by correlation and bivariate logistic regression analyses.RESULTS: The distance from the photopic to the mesopic pupil center(pupil center shift) was significantly associated with glare/halo symptoms [odds ratio(OR)=2.065,95% confidence interval(CI)=0.916-4.679,P=0.006] and night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007).The preoperative photopic angle kappa was significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041).The photopic angle kappa was also significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041) and with night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007) in patients implanted with rotationally asymmetric MIOLs.CONCLUSION: A large pupil center shift and misalignment between the visual and pupillary axis(angle kappa)may play a role in the occurrence of photic phenomena after implantation of rotationally asymmetric MIOLs. 展开更多
关键词 rotationally asymmetric multifocal intraocular lens pupil center photic phenomena dysphotopsia kappa angle pupil center shift
下载PDF
上一页 1 2 55 下一页 到第
使用帮助 返回顶部