●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria...●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.展开更多
AIM:To evaluate the trending visual performance of different intraocular lenses(IOLs)over time after implantation.METHODS:Ninety-one patients received cataract surgery with implantations of monofocal(Mon)IOLs,segmenta...AIM:To evaluate the trending visual performance of different intraocular lenses(IOLs)over time after implantation.METHODS:Ninety-one patients received cataract surgery with implantations of monofocal(Mon)IOLs,segmental refractive(SegRef)IOLs,diffractive(Dif)IOLs,and extendeddepth-of-focus(EDoF)IOLs were included.The aberrations and optical quality collected with iTrace and OQAS within postoperative 6mo were followed and compared.RESULTS:Most of the visual parameters improved over the postoperative 6mo.The postoperative visual acuity(POVA)of the Mon IOL,SegRef IOL,and EDoF IOL groups achieved relative stability in earlier states compared with the Dif IOL group.Nevertheless,the overall visual performance of the 3 IOLs continued to upturn in small extents within the postoperative 6mo.The optical quality initially improved in the EDoF IOL group,then in the Mon IOL,SegRef IOL,and Dif IOL groups.POVA and objective visual performance of the Mon IOL and EDoF IOL groups,as well as POVA and visual quality of the Dif IOL group,improved in the postoperative 1mo and stabilized.Within the postoperative 6mo,gradual improvements were observed in the visual acuity and objective visual performance of the SegRef IOL group,as well as in the postoperative optical quality of the Dif IOL group.CONCLUSION:The visual performance is different among eyes implanted with different IOLs.The findings of the current study provide a potential reference for ophthalmologists to choose suitable IOLs for cataract patients in a personalized solution.展开更多
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ...AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.展开更多
AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who...AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who received sulcus-placed SPA-IOLs between 2006 and 2009 were reviewed. None of the patients underwent IOL exchange. Charts of six age-matched patients who received sulcus placed 3P-IOLs were reviewed as a control group. RESULTS: Mean follow up was 16 mo for SPA-IOL and 23 mo for 3P-IOL. Five of 8 patients in the SPA-IOL group required chronic use of IOP lowering medications at final follow up. Of these, one patient needed glaucoma implant surgery for uncontrolled IOP. One patient in the 3P-IOL group used chronic aqueous suppression pre- and postoperatively. Four of eight eyes with SPAIOL were treated with chronic topical steroids and or non-steroidal anti-inflammatory drugs for cystoid macu-la edema, chronic uveitis, pigment dispersion syndrome or a combination of the above, compared to none in the control group. Mean best-corrected visual acuity was 20/35 in the SPA-IOL group and 20/47 in the 3PIOL group.CONCLUSION: Sulcus placed SPA-IOLs are associated with increased ocular morbidity. In select cases good visual acuity may be achieved. Due to postoperative rotation of sulcus placed toric SPA-IOLs stable astigmatism correction cannot be achieved. Alternative intraocular lenses should be considered when in-the-bag placement of SPA-IOL is not possible.展开更多
AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL...AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.METHODS:In this retrospective case series,32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter(D).A plate haptic toric IOL(AT Torbi 709M,Carl Zeiss Meditec AG)was implanted in all eyes.The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity(BCVA).RESULTS:Preoperative refractive astigmatism was 2.14±1.17 D,which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period(0.67±0.44 D at three months and 0.75±0.25 D at six months;for all groups:P<0.0001 compared to baseline).BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery(P=0.02).Mean IOL axis deviation from the target axis was 3.4°±2.9°after six to eight weeks and significantly decreased over time(2.4°±2.6°six months after surgery;P=0.04).In one patient IOL,re-alignment was performed.CONCLUSION:Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.The plate haptic toric IOL position and axis remain stable during the observation period of six months.展开更多
AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectiv...AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectively analyzed 16 eyes of 16 patients who underwent transscleral fixation of C-loop PCIOLs using a flapless one-knot suture technique,which were followed up for longer than 17mo.In this technique,the capsulorless IOL was suspended using a single suture for transscleral fixation of four feet.Then we compared its surgical outcomes and complications with the four-haptics PC-IOLs using the Student's t test and Chi-square test.RESULTS:Sixteen patients of 16 eyes with a mean age of 58.3±10.1y(42-76y)who received transscleral C-loop IOL implantation due to trauma,vitrectomy,or cataract surgery with inadequate capsule support showed improved visual acuity.The difference was not significant between two IOLs except the surgery time(P>0.05).The mean operation times of C-loop IOL surgery was 24.1±1.83min and 31.3±4.47min of the four-haptics PC-IOL method(P<0.0001).In the C-loop IOLs group,there was statistical difference between the preoperative and the postoperative UCVA(log MAR,1.20±0.50 vs 0.57±0.32,P=0.0003).There was no statistical difference between the preoperative and the postoperative BCVA(log MAR,0.66±0.46 vs 0.40±0.23,P=0.056).However,there was no statistically significant difference in postoperative UCVA and BCVA between the two IOLs(P>0.05).We did not detect any optic capture,IOL decentration or dislocation,suture exposed,or cystoid macular edema in patients underwent C-loop IOLs surgery.CONCLUSION:The novel flapless one-knot suture technique for transscleral fixation of C-loop IOL is a simple,reliable,and stable technique.展开更多
AIM:To assess the performance of a bespoke software for automated counting of intraocular lens(IOL)glistenings in slit-lamp images.METHODS:IOL glistenings from slit-lamp-derived digital images were counted manually an...AIM:To assess the performance of a bespoke software for automated counting of intraocular lens(IOL)glistenings in slit-lamp images.METHODS:IOL glistenings from slit-lamp-derived digital images were counted manually and automatically by the bespoke software.The images of one randomly selected eye from each of 34 participants were used as a training set to determine the threshold setting that gave the best agreement between manual and automatic grading.A second set of 63 images,selected using randomised stratified sampling from 290 images,were used for software validation.The images were obtained using a previously described protocol.Software-derived automated glistenings counts were compared to manual counts produced by three ophthalmologists.RESULTS:A threshold value of 140 was determined that minimised the total deviation in the number of glistenings for the 34 images in the training set.Using this threshold value,only slight agreement was found between automated software counts and manual expert counts for the validating set of 63 images(κ=0.104,95%CI,0.040-0.168).Ten images(15.9%)had glistenings counts that agreed between the software and manual counting.There were 49 images(77.8%)where the software overestimated the number of glistenings.CONCLUSION:The low levels of agreement show between an initial release of software used to automatically count glistenings in in vivo slit-lamp images and manual counting indicates that this is a non-trivial application.Iterative improvement involving a dialogue between software developers and experienced ophthalmologists is required to optimise agreement.The results suggest that validation of software is necessary for studies involving semi-automatic evaluation of glistenings.展开更多
I am Dr. David P Pifiero from the Department of Optics, Pharmacology and Anatomy of the University of Alicante and from the Department of Ophthalmology of Vithas Medimar (Oftalmar) and Vithas Virgen del Carmen (Qv...I am Dr. David P Pifiero from the Department of Optics, Pharmacology and Anatomy of the University of Alicante and from the Department of Ophthalmology of Vithas Medimar (Oftalmar) and Vithas Virgen del Carmen (Qvision) hospitals in Spain.展开更多
Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number...Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number of focal points that each lens provides,which in turn leads to different visual outcomes.Familiarity of surgeons with the various characteristics of each lens is of utmost importance for accurate IOL selection to match each patient’s needs.In this review,we aim to compare the clinical outcomes after implantation of multifocal and EDOF IOLs in terms of distance,intermediate and near vision,contrast sensitivity,and reading performance.Finally,we discuss the defocus curve and the optical and photic phenomena associated with each type of IOL.展开更多
AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and ana...AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and analysis of complications. METHODS: The comparative prospective study included 39 eyes of 23 patients with high myopia, 19 eyes had Visian lens implantation(model V4 c) and 20 eyes had Artiflex lens implantation. The inclusion criteria were high myopia(higher than 6.0 D) and stable refraction(<0.5 D change over one year). Outcomes included assessment of safety and efficacy indices, predictability, stability, contrast sensitivity and analysis of complications at postoperative 1 d, 1 wk and 1, 3, 6 and 12 mo. Selection of the type of phakic intraocular lens for patients was based on surgeons' preferences, which was no specific selection criteria. RESULTS: After 12 mo of follow up, difference in uncorrected and corrected distant visual acuity(CDVA) between both groups was statistically insignificant(UDVA for VisianV4 c and Artiflex lens were 0.33±0.2 logMAR and 0.37±0.2 logMAR respectively, P=0.59, CDVA for VisianV4 c and Artiflex lens were 0.155±0.1 logMAR and 0.147± 0.1 logMAR respectively, P=0.87). The efficacy index was 1.25 for VisianV4 c lens and 0.8 for Artiflex lens, 78.9% of eyes were within one diopter spherical equivalent in Visian V4 c lens group compared to 70% in the Artiflex lens group. No eye lost lines of CVDA proving a good safety index for both lenses(safety index was 1.67 for VisianV4 c lens and 1.34 for Artiflex lens). Difference in contrast sensitivity between both groups was statistically insignificant(P=0.15, 0.88, 0.27, 0.32 and 0.82 at five spatial frequencies). CONCLUSION: Both Visian ICL V4 c and Artiflex lensesare safe and effective with stable and predictable refraction and they have comparable contrast sensitivity outcomes with no vision threatening complications.展开更多
AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty...AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses.展开更多
·AIM:To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL.·ME...·AIM:To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL.·METHODS:This study randomized 60 patients into equal groups to receive toric IOL or spherical IOL.IOL powers targeting emmetropia were selected for 93% of toric IOL patients and for 90% of spherical IOL patients.Assessments included monocular and binocular distance vision,with and without best correction.Patients also completed surveys about their distance vision.·RESULTS:Preoperatively,the two study groups were similar in age,in distance visual acuity,and in the magnitude of corneal astigmatism.At 6 months postoperative,binocular uncorrected distance vision was 0.06?à0.14 logMAR in the AcrySof toric IOL group,significantly better than the 0.14?à0.11 logMAR in the spherical IOL group (P<0.05).For eyes with emmetropia as a target,the equivalent of 20/20 uncorrected vision was more likely (P<0.001) in the toric IOL group (36% of eyes) than in the spherical IOL group (4% of eyes).No patients in the emmetropia/toric IOL group used distance glasses,as compared to 52% of patients in the emmetropia/spherical IOL group.All patients were satisfied or highly satisfied.Quality of distance vision was rated higher by toric IOL patients than by spherical IOL patients (P<0.05).·CONCLUSION:Bilateral AcrySof toric IOL is superior to bilateral spherical IOL in providing uncorrected distance vision to cataract patients with corneal astigmatism.·展开更多
AIM: To prepare a new-type soft intraocular lens (IOL) that silicone intraocular lenses (IOLs) were modified by surface modification technique to assess IOLs biocompatibility. METHODS: With the technique of ion beam c...AIM: To prepare a new-type soft intraocular lens (IOL) that silicone intraocular lenses (IOLs) were modified by surface modification technique to assess IOLs biocompatibility. METHODS: With the technique of ion beam combined with low temperature and low pressure plasma, the surface characteristics of the IOLs including physical and optical properties were determined by the instruments of IOLs resolution, UV/VIS scanning spectrophotometer, contact angle measurement system, electron spectroscopy for chemical analysis (ESCA) and scanning electron microscope (SEM). RESULTS: The color of titanium (Ti) modified IOLs was light yellow and that of titanium nitride (TiN) modified IOLs was light brown. The absorptive degree of ultraviolet rays and the hydrophilicity of the surfaces of modified IOLs were increased, and appeared suitable chemical compositions. The resolution of unmodified and modified IOLs reached normal standard. The surfaces of unmodified and Ti-modified IOLs appeared uniform. The surfaces of TIN-modified IOLs presented fine porcelain structure. CONCLUSION: The optical properties of all IOLs and the surface morphology of the modified IOLs were not affected by modification processes. The surface properties of the modified IOLs were improved.展开更多
Multifocal intraocular lenses(IOLs) are currently usually implanted for the treatment of cataracts because they have been proved to be superior to monofocal IOLs with respect to spectacle independence. In turn, they a...Multifocal intraocular lenses(IOLs) are currently usually implanted for the treatment of cataracts because they have been proved to be superior to monofocal IOLs with respect to spectacle independence. In turn, they are associated with a higher prevalence of dysphotopsia symptoms that is one of the most common causes of patient dissatisfaction. Neuroadaptation seems to play a major role in the optimal adaptation to multifocal IOLs. In this context, the development of strategies that facilitate the neuroadaptation process to multifocality might be an effective strategy to reduce patients' dissatisfaction. Video games have been proved to be effective for the improvement of visual acuity and for the promotion of neuroplasticity in elderly subjects and other populations with cortical-related visual impairment. This narrative review highlights the physiological potential of video games as a perceptual strategy to improve visual acuity and promote neuroplasticity in patients using multifocalIOLs, although research is still needed to confirm these benefits in this specific population, with only one comparative study to this date providing evidence of them.展开更多
Transscleral suturing is a commonly applied technique to fix intraocular Implants in the sulcus.A major problem after transscleral implantation is suture erosion that normally happens in the late post-surgery period a...Transscleral suturing is a commonly applied technique to fix intraocular Implants in the sulcus.A major problem after transscleral implantation is suture erosion that normally happens in the late post-surgery period and may result In an Increased incidence of endophthalmitis.Here we describe an original cauterization method by using a glass rod to melt the exposed suture end without damaging the suture knot in the sclera to avoid suture exposure in sclera-fixed IOL implantation.This is a simple,quick and effective technique that can be performed without conjunctiva incisions and will help to reduce suture erosion related complications.展开更多
AIMTo compare the visual outcomes (distance and near) in patients opting for three different types of monofocal intraocular lens (IOL) (Matrix Aurium, AcrySof single piece, and AcrySof IQ lens).METHODSThe present stud...AIMTo compare the visual outcomes (distance and near) in patients opting for three different types of monofocal intraocular lens (IOL) (Matrix Aurium, AcrySof single piece, and AcrySof IQ lens).METHODSThe present study is a cross-sectional analysis of secondary clinical data collected from 153 eyes (52 eyes in Matrix Aurium, 48 in AcrySof single piece, and 53 in AcrySof IQ group) undergoing cataract surgery (2011-2012). We compared near vision, distance vision, distance corrected near vision in these three types of lenses on day 15 (±3) post-surgery.RESULTSAbout 69% of the eyes in the Matrix Aurium group had good uncorrected distance vision post-surgery; the proportion was 48% and 57% in the AcrySof single piece and AcrySof IQ group (P=0.09). The proportion of eyes with good distance corrected near vision were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). Similarly, The proportion with good “both near and distance vision” were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). It was only the Matrix Aurium group which had significantly better both “distance and near vision” compared with the AcrySof IQ group (odds ratio: 5.87, 95% confidence intervals: 1.68 to 20.56).CONCLUSIONMatrix Aurium monofocal lenses may be a good option for those patients who desire to have a good near as well as distance vision post-surgery.展开更多
Background:To compare objective electrophysiological contrast sensitivity function(CSF)in patients implanted with either multifocal intraocular lenses(MIOLs)or monofocal intraocular lenses(IOLs)by pattern reversal vis...Background:To compare objective electrophysiological contrast sensitivity function(CSF)in patients implanted with either multifocal intraocular lenses(MIOLs)or monofocal intraocular lenses(IOLs)by pattern reversal visual evoked potentials(prVEP)measurements.Methods:Fourty-five cataract patients were randomly allocated to receive bilaterally:apodized diffractive-refractive Alcon Acrysof MIOL(A),full diffractive AMO Tecnis MIOL(B)or monofocal Alcon Acrysof IOL(C).Primary outcomes:1-year differences in objective binocular CSF measured by prVEP with sinusoid grating stimuli of 6 decreasing contrast levels at 6 spatial frequencies.Secondary outcomes:psychophysical CSF measured with VCTS-6500,photopic uncorrected distance(UDVA),and mesopic and photopic uncorrected near and intermediate visual acuities(UNVA and UIVA respectively).Results:Electrophysiological CSF curve had an inverted U-shaped morphology in all groups,with a biphasic pattern in Group B.Group A showed a lower CSF than group B at 4 and 8 cpd,and a lower value than group C at 8 cpd.Psychophysical CSF in group A exhibited a lower value at 12 cpd than group B.Mean photopic and mesopic UNVA and UIVA were worse in monofocal group compared to the multifocal groups.Mesopic UNVA and UIVA were better in group B.Conclusions:Electrophysiological CSF behaves differently depending on the types of multifocal or monofocal IOLs.This may be related to the visual acuity under certain conditions or to IOL characteristics.This objective method might be a potential new tool to investigate on MIOL differences and on subjective device-related quality of vision.展开更多
·AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). ...·AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). ·METHODS: Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively: monocular and binocular uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) for distance, intermediate and near, spherical aberration (SA), contrast and glare sensitivity, near point refractive power, uncorrected and best corrected near stereoscopic acuity (NSA). Patient satisfaction was assessed by a questionnaire. ·RESULTS:Threemonthspostoperatively,themonocular and binocular UCVA and DCVA at near of Tecnis ZMA00 were significantly better than other two groups. The mean SA for 5.0mm optical zone in Tecnis ZMA00 and Tecnis ZA9003 was significantly lower than that in Akreos Adapt. Mean contrast sensitivity and glare sensitivity were better for Tecnis ZA9003 group than for other two groups. Patients with Tecnis ZMA00 had higher monocular and binocular near point refractive power and uncorrected NSA than monofocal groups. The patients in Tecnis ZMA00 had higher mean values for halo compared with other two groups. ·CONCLUSION: Tecnis ZMA00 provided better near VA and uncorrected NSA and higher near point refractive power than monofocal IOLs and patients were spectacle independent. The IOLs with Tecnis aspheric design improved contrast and glare sensitivity. Patients with Tecnis ZMA00 reported more disturbances on visual phenomena of halo. ·展开更多
文摘●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.
基金Supported by the“Municipal School(College)Joint Funding(Zhongnanshan Medical Foundation of Guangdong Province)Project”of Guangzhou Municipal Science and Technology Bureau(No.202201020458)the“Guangzhou Health Science and Technology General Guidance Project(Western Medicine Project)”of Guangzhou Municipal Health Commission(No.20231A011083).
文摘AIM:To evaluate the trending visual performance of different intraocular lenses(IOLs)over time after implantation.METHODS:Ninety-one patients received cataract surgery with implantations of monofocal(Mon)IOLs,segmental refractive(SegRef)IOLs,diffractive(Dif)IOLs,and extendeddepth-of-focus(EDoF)IOLs were included.The aberrations and optical quality collected with iTrace and OQAS within postoperative 6mo were followed and compared.RESULTS:Most of the visual parameters improved over the postoperative 6mo.The postoperative visual acuity(POVA)of the Mon IOL,SegRef IOL,and EDoF IOL groups achieved relative stability in earlier states compared with the Dif IOL group.Nevertheless,the overall visual performance of the 3 IOLs continued to upturn in small extents within the postoperative 6mo.The optical quality initially improved in the EDoF IOL group,then in the Mon IOL,SegRef IOL,and Dif IOL groups.POVA and objective visual performance of the Mon IOL and EDoF IOL groups,as well as POVA and visual quality of the Dif IOL group,improved in the postoperative 1mo and stabilized.Within the postoperative 6mo,gradual improvements were observed in the visual acuity and objective visual performance of the SegRef IOL group,as well as in the postoperative optical quality of the Dif IOL group.CONCLUSION:The visual performance is different among eyes implanted with different IOLs.The findings of the current study provide a potential reference for ophthalmologists to choose suitable IOLs for cataract patients in a personalized solution.
文摘AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.
基金Supported by NIH Center Core,No.P30EY014801Research to Prevent Blindness Unrestricted Grant,Department of Defense,No.DOD-Grant#W81XWH-09-1-0675
文摘AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who received sulcus-placed SPA-IOLs between 2006 and 2009 were reviewed. None of the patients underwent IOL exchange. Charts of six age-matched patients who received sulcus placed 3P-IOLs were reviewed as a control group. RESULTS: Mean follow up was 16 mo for SPA-IOL and 23 mo for 3P-IOL. Five of 8 patients in the SPA-IOL group required chronic use of IOP lowering medications at final follow up. Of these, one patient needed glaucoma implant surgery for uncontrolled IOP. One patient in the 3P-IOL group used chronic aqueous suppression pre- and postoperatively. Four of eight eyes with SPAIOL were treated with chronic topical steroids and or non-steroidal anti-inflammatory drugs for cystoid macu-la edema, chronic uveitis, pigment dispersion syndrome or a combination of the above, compared to none in the control group. Mean best-corrected visual acuity was 20/35 in the SPA-IOL group and 20/47 in the 3PIOL group.CONCLUSION: Sulcus placed SPA-IOLs are associated with increased ocular morbidity. In select cases good visual acuity may be achieved. Due to postoperative rotation of sulcus placed toric SPA-IOLs stable astigmatism correction cannot be achieved. Alternative intraocular lenses should be considered when in-the-bag placement of SPA-IOL is not possible.
文摘AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.METHODS:In this retrospective case series,32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter(D).A plate haptic toric IOL(AT Torbi 709M,Carl Zeiss Meditec AG)was implanted in all eyes.The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity(BCVA).RESULTS:Preoperative refractive astigmatism was 2.14±1.17 D,which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period(0.67±0.44 D at three months and 0.75±0.25 D at six months;for all groups:P<0.0001 compared to baseline).BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery(P=0.02).Mean IOL axis deviation from the target axis was 3.4°±2.9°after six to eight weeks and significantly decreased over time(2.4°±2.6°six months after surgery;P=0.04).In one patient IOL,re-alignment was performed.CONCLUSION:Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.The plate haptic toric IOL position and axis remain stable during the observation period of six months.
基金Supported by the Gongli Hospital of Pudong New Area,Shanghai(No.2017YQNJJ-13)。
文摘AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectively analyzed 16 eyes of 16 patients who underwent transscleral fixation of C-loop PCIOLs using a flapless one-knot suture technique,which were followed up for longer than 17mo.In this technique,the capsulorless IOL was suspended using a single suture for transscleral fixation of four feet.Then we compared its surgical outcomes and complications with the four-haptics PC-IOLs using the Student's t test and Chi-square test.RESULTS:Sixteen patients of 16 eyes with a mean age of 58.3±10.1y(42-76y)who received transscleral C-loop IOL implantation due to trauma,vitrectomy,or cataract surgery with inadequate capsule support showed improved visual acuity.The difference was not significant between two IOLs except the surgery time(P>0.05).The mean operation times of C-loop IOL surgery was 24.1±1.83min and 31.3±4.47min of the four-haptics PC-IOL method(P<0.0001).In the C-loop IOLs group,there was statistical difference between the preoperative and the postoperative UCVA(log MAR,1.20±0.50 vs 0.57±0.32,P=0.0003).There was no statistical difference between the preoperative and the postoperative BCVA(log MAR,0.66±0.46 vs 0.40±0.23,P=0.056).However,there was no statistically significant difference in postoperative UCVA and BCVA between the two IOLs(P>0.05).We did not detect any optic capture,IOL decentration or dislocation,suture exposed,or cystoid macular edema in patients underwent C-loop IOLs surgery.CONCLUSION:The novel flapless one-knot suture technique for transscleral fixation of C-loop IOL is a simple,reliable,and stable technique.
文摘AIM:To assess the performance of a bespoke software for automated counting of intraocular lens(IOL)glistenings in slit-lamp images.METHODS:IOL glistenings from slit-lamp-derived digital images were counted manually and automatically by the bespoke software.The images of one randomly selected eye from each of 34 participants were used as a training set to determine the threshold setting that gave the best agreement between manual and automatic grading.A second set of 63 images,selected using randomised stratified sampling from 290 images,were used for software validation.The images were obtained using a previously described protocol.Software-derived automated glistenings counts were compared to manual counts produced by three ophthalmologists.RESULTS:A threshold value of 140 was determined that minimised the total deviation in the number of glistenings for the 34 images in the training set.Using this threshold value,only slight agreement was found between automated software counts and manual expert counts for the validating set of 63 images(κ=0.104,95%CI,0.040-0.168).Ten images(15.9%)had glistenings counts that agreed between the software and manual counting.There were 49 images(77.8%)where the software overestimated the number of glistenings.CONCLUSION:The low levels of agreement show between an initial release of software used to automatically count glistenings in in vivo slit-lamp images and manual counting indicates that this is a non-trivial application.Iterative improvement involving a dialogue between software developers and experienced ophthalmologists is required to optimise agreement.The results suggest that validation of software is necessary for studies involving semi-automatic evaluation of glistenings.
文摘I am Dr. David P Pifiero from the Department of Optics, Pharmacology and Anatomy of the University of Alicante and from the Department of Ophthalmology of Vithas Medimar (Oftalmar) and Vithas Virgen del Carmen (Qvision) hospitals in Spain.
文摘Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number of focal points that each lens provides,which in turn leads to different visual outcomes.Familiarity of surgeons with the various characteristics of each lens is of utmost importance for accurate IOL selection to match each patient’s needs.In this review,we aim to compare the clinical outcomes after implantation of multifocal and EDOF IOLs in terms of distance,intermediate and near vision,contrast sensitivity,and reading performance.Finally,we discuss the defocus curve and the optical and photic phenomena associated with each type of IOL.
文摘AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and analysis of complications. METHODS: The comparative prospective study included 39 eyes of 23 patients with high myopia, 19 eyes had Visian lens implantation(model V4 c) and 20 eyes had Artiflex lens implantation. The inclusion criteria were high myopia(higher than 6.0 D) and stable refraction(<0.5 D change over one year). Outcomes included assessment of safety and efficacy indices, predictability, stability, contrast sensitivity and analysis of complications at postoperative 1 d, 1 wk and 1, 3, 6 and 12 mo. Selection of the type of phakic intraocular lens for patients was based on surgeons' preferences, which was no specific selection criteria. RESULTS: After 12 mo of follow up, difference in uncorrected and corrected distant visual acuity(CDVA) between both groups was statistically insignificant(UDVA for VisianV4 c and Artiflex lens were 0.33±0.2 logMAR and 0.37±0.2 logMAR respectively, P=0.59, CDVA for VisianV4 c and Artiflex lens were 0.155±0.1 logMAR and 0.147± 0.1 logMAR respectively, P=0.87). The efficacy index was 1.25 for VisianV4 c lens and 0.8 for Artiflex lens, 78.9% of eyes were within one diopter spherical equivalent in Visian V4 c lens group compared to 70% in the Artiflex lens group. No eye lost lines of CVDA proving a good safety index for both lenses(safety index was 1.67 for VisianV4 c lens and 1.34 for Artiflex lens). Difference in contrast sensitivity between both groups was statistically insignificant(P=0.15, 0.88, 0.27, 0.32 and 0.82 at five spatial frequencies). CONCLUSION: Both Visian ICL V4 c and Artiflex lensesare safe and effective with stable and predictable refraction and they have comparable contrast sensitivity outcomes with no vision threatening complications.
文摘AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses.
文摘·AIM:To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL.·METHODS:This study randomized 60 patients into equal groups to receive toric IOL or spherical IOL.IOL powers targeting emmetropia were selected for 93% of toric IOL patients and for 90% of spherical IOL patients.Assessments included monocular and binocular distance vision,with and without best correction.Patients also completed surveys about their distance vision.·RESULTS:Preoperatively,the two study groups were similar in age,in distance visual acuity,and in the magnitude of corneal astigmatism.At 6 months postoperative,binocular uncorrected distance vision was 0.06?à0.14 logMAR in the AcrySof toric IOL group,significantly better than the 0.14?à0.11 logMAR in the spherical IOL group (P<0.05).For eyes with emmetropia as a target,the equivalent of 20/20 uncorrected vision was more likely (P<0.001) in the toric IOL group (36% of eyes) than in the spherical IOL group (4% of eyes).No patients in the emmetropia/toric IOL group used distance glasses,as compared to 52% of patients in the emmetropia/spherical IOL group.All patients were satisfied or highly satisfied.Quality of distance vision was rated higher by toric IOL patients than by spherical IOL patients (P<0.05).·CONCLUSION:Bilateral AcrySof toric IOL is superior to bilateral spherical IOL in providing uncorrected distance vision to cataract patients with corneal astigmatism.·
基金A Foundation for the Author of National Excellent Doctoral Dissertation of PR China(No.10021201)
文摘AIM: To prepare a new-type soft intraocular lens (IOL) that silicone intraocular lenses (IOLs) were modified by surface modification technique to assess IOLs biocompatibility. METHODS: With the technique of ion beam combined with low temperature and low pressure plasma, the surface characteristics of the IOLs including physical and optical properties were determined by the instruments of IOLs resolution, UV/VIS scanning spectrophotometer, contact angle measurement system, electron spectroscopy for chemical analysis (ESCA) and scanning electron microscope (SEM). RESULTS: The color of titanium (Ti) modified IOLs was light yellow and that of titanium nitride (TiN) modified IOLs was light brown. The absorptive degree of ultraviolet rays and the hydrophilicity of the surfaces of modified IOLs were increased, and appeared suitable chemical compositions. The resolution of unmodified and modified IOLs reached normal standard. The surfaces of unmodified and Ti-modified IOLs appeared uniform. The surfaces of TIN-modified IOLs presented fine porcelain structure. CONCLUSION: The optical properties of all IOLs and the surface morphology of the modified IOLs were not affected by modification processes. The surface properties of the modified IOLs were improved.
基金Coco-Martin MB,Maldonado-López MJ,Molina-Martín A and Pi?ero DP are supported by CDTI(Centro para el Desarrollo Tecnológico Industrial,Ministry of Economy and Competitiveness of Spain)by means of the program PID(“Proyectos de Investigación y Desarrollo”)The author Pi?ero DP has been also supported by the Ministry of Economy,Industry and Competitiveness of Spain within the program Ramón y Cajal(RYC-2016-20471)Valenzuela PL is supported by a contract granted by University of Alcalá(FPI2016)
文摘Multifocal intraocular lenses(IOLs) are currently usually implanted for the treatment of cataracts because they have been proved to be superior to monofocal IOLs with respect to spectacle independence. In turn, they are associated with a higher prevalence of dysphotopsia symptoms that is one of the most common causes of patient dissatisfaction. Neuroadaptation seems to play a major role in the optimal adaptation to multifocal IOLs. In this context, the development of strategies that facilitate the neuroadaptation process to multifocality might be an effective strategy to reduce patients' dissatisfaction. Video games have been proved to be effective for the improvement of visual acuity and for the promotion of neuroplasticity in elderly subjects and other populations with cortical-related visual impairment. This narrative review highlights the physiological potential of video games as a perceptual strategy to improve visual acuity and promote neuroplasticity in patients using multifocalIOLs, although research is still needed to confirm these benefits in this specific population, with only one comparative study to this date providing evidence of them.
基金The Bureau of Science and Technology of Wenzhou,Zhejiang Province,China(No.Y20100196)
文摘Transscleral suturing is a commonly applied technique to fix intraocular Implants in the sulcus.A major problem after transscleral implantation is suture erosion that normally happens in the late post-surgery period and may result In an Increased incidence of endophthalmitis.Here we describe an original cauterization method by using a glass rod to melt the exposed suture end without damaging the suture knot in the sclera to avoid suture exposure in sclera-fixed IOL implantation.This is a simple,quick and effective technique that can be performed without conjunctiva incisions and will help to reduce suture erosion related complications.
文摘AIMTo compare the visual outcomes (distance and near) in patients opting for three different types of monofocal intraocular lens (IOL) (Matrix Aurium, AcrySof single piece, and AcrySof IQ lens).METHODSThe present study is a cross-sectional analysis of secondary clinical data collected from 153 eyes (52 eyes in Matrix Aurium, 48 in AcrySof single piece, and 53 in AcrySof IQ group) undergoing cataract surgery (2011-2012). We compared near vision, distance vision, distance corrected near vision in these three types of lenses on day 15 (±3) post-surgery.RESULTSAbout 69% of the eyes in the Matrix Aurium group had good uncorrected distance vision post-surgery; the proportion was 48% and 57% in the AcrySof single piece and AcrySof IQ group (P=0.09). The proportion of eyes with good distance corrected near vision were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). Similarly, The proportion with good “both near and distance vision” were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). It was only the Matrix Aurium group which had significantly better both “distance and near vision” compared with the AcrySof IQ group (odds ratio: 5.87, 95% confidence intervals: 1.68 to 20.56).CONCLUSIONMatrix Aurium monofocal lenses may be a good option for those patients who desire to have a good near as well as distance vision post-surgery.
文摘Background:To compare objective electrophysiological contrast sensitivity function(CSF)in patients implanted with either multifocal intraocular lenses(MIOLs)or monofocal intraocular lenses(IOLs)by pattern reversal visual evoked potentials(prVEP)measurements.Methods:Fourty-five cataract patients were randomly allocated to receive bilaterally:apodized diffractive-refractive Alcon Acrysof MIOL(A),full diffractive AMO Tecnis MIOL(B)or monofocal Alcon Acrysof IOL(C).Primary outcomes:1-year differences in objective binocular CSF measured by prVEP with sinusoid grating stimuli of 6 decreasing contrast levels at 6 spatial frequencies.Secondary outcomes:psychophysical CSF measured with VCTS-6500,photopic uncorrected distance(UDVA),and mesopic and photopic uncorrected near and intermediate visual acuities(UNVA and UIVA respectively).Results:Electrophysiological CSF curve had an inverted U-shaped morphology in all groups,with a biphasic pattern in Group B.Group A showed a lower CSF than group B at 4 and 8 cpd,and a lower value than group C at 8 cpd.Psychophysical CSF in group A exhibited a lower value at 12 cpd than group B.Mean photopic and mesopic UNVA and UIVA were worse in monofocal group compared to the multifocal groups.Mesopic UNVA and UIVA were better in group B.Conclusions:Electrophysiological CSF behaves differently depending on the types of multifocal or monofocal IOLs.This may be related to the visual acuity under certain conditions or to IOL characteristics.This objective method might be a potential new tool to investigate on MIOL differences and on subjective device-related quality of vision.
基金Zhejiang Key Innovation Team Project(No. 2009R50039)Doctoral Fund of Ministry of Education of China (No: 20100101120135)Key Lab Fund of Zhejiang Province, China (No. 2011E10006)
文摘·AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). ·METHODS: Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively: monocular and binocular uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) for distance, intermediate and near, spherical aberration (SA), contrast and glare sensitivity, near point refractive power, uncorrected and best corrected near stereoscopic acuity (NSA). Patient satisfaction was assessed by a questionnaire. ·RESULTS:Threemonthspostoperatively,themonocular and binocular UCVA and DCVA at near of Tecnis ZMA00 were significantly better than other two groups. The mean SA for 5.0mm optical zone in Tecnis ZMA00 and Tecnis ZA9003 was significantly lower than that in Akreos Adapt. Mean contrast sensitivity and glare sensitivity were better for Tecnis ZA9003 group than for other two groups. Patients with Tecnis ZMA00 had higher monocular and binocular near point refractive power and uncorrected NSA than monofocal groups. The patients in Tecnis ZMA00 had higher mean values for halo compared with other two groups. ·CONCLUSION: Tecnis ZMA00 provided better near VA and uncorrected NSA and higher near point refractive power than monofocal IOLs and patients were spectacle independent. The IOLs with Tecnis aspheric design improved contrast and glare sensitivity. Patients with Tecnis ZMA00 reported more disturbances on visual phenomena of halo. ·