This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly f...This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly from high-voltage (HV) transmission lines to low-voltage (LV) consumers through coupling capacitors and is said to be cost-effective as compared to conventional distribution networks. However, the functionality of such substations is susceptible to various transient phenomena, including ferroresonance and overvoltage occurrences. To address these challenges, the study uses simulations to evaluate the effectiveness of conventional resistor-inductor-capacitor (RLC) filter in mitigating hazardous overvoltage resulting from transients. The proposed methodology entails using standard RLC filter to suppress transients and its associated overvoltage risks. Through a series of MATLAB/Simulink simulations, the research emphasizes the practical effectiveness of this technique. The study examines the impact of transients under varied operational scenarios, including no-load switching conditions, temporary short-circuits, and load on/off events. The primary aim of the article is to assess the viability of using an established technology to manage system instabilities upon the energization of a CCS under no-load circumstances or in case of a short-circuit fault occurring on the primary side of the CCS distribution transformer. The findings underscore the effectiveness of conventional RLC filters in suppressing transients induced by the CCS no-load switching.展开更多
In order to improve the voltage quality of rural power distribution network, the series capacitor in distribution lines is proposed. The principle of series capacitor compensation technology to improve the quality of ...In order to improve the voltage quality of rural power distribution network, the series capacitor in distribution lines is proposed. The principle of series capacitor compensation technology to improve the quality of rural power distribution lines voltage is analyzed. The real rural power distribution network simulation model is established by Power System Power System Analysis Software Package (PSASP). Simulation analysis the effect of series capacitor compensation technology to improve the voltage quality of rural power distribution network, The simulation results show that the series capacitor compensation can effectively improve the voltage quality and reduce network losses and improve the transmission capacity of rural power distribution network.展开更多
The large variability in wind output power can adversely impact local loads that are sensitive to poor power quality. To mitigate large swings in power, the wind turbine output power can be conditioned by using a smal...The large variability in wind output power can adversely impact local loads that are sensitive to poor power quality. To mitigate large swings in power, the wind turbine output power can be conditioned by using a small energy buffer. A power conditioner is developed to smooth the wind power output by utilizing the energy of an electrochemical capacitor, or ultracapacitor. The conditioner is based on a single phase voltage source inverter connected between the grid inter-connection point and the ultracapacitor. The VSI shunt inverter injects or absorbs active power from the line to smooth the wind power output by utilizing the short term storage capabilities of the ultracapacitor. The ultracapacitor is connected to the DC link through a bidirectional DC-DC converter. The bidirectional DC-DC converter and VSI are constructed and field tested on a Skystream 3.7 wind turbine installed at the Missouri University of Science & Technology.展开更多
In this paper, a mathematical analysis of the EMI (Electromagnetic Interference) for a 20 kHz/10 kV capacitor charging power supply in frequency-domain is presented, and a related circuit model considering the transie...In this paper, a mathematical analysis of the EMI (Electromagnetic Interference) for a 20 kHz/10 kV capacitor charging power supply in frequency-domain is presented, and a related circuit model considering the transient switching interference is proposed. Due to the high working frequency and the device-switching transitions, the conducted EMI caused by the charging circuit which includes the harmonics of grid frequency, working frequency and device-switching transition frequencies. Thus under certain working situations or loads parallel power supply, the interference may cause charging failure. To solve this problem, a high frequency transformer modeled with stray capacitances and an approximation of the device-switching transition is applied in the Spice-based simulation model, and a mathematical analysis in frequency-domain is presented.展开更多
Rechargeable aqueous zinc-ion hybrid capacitors and zincion batteries are promising safe energy storage systems.In this study,amorphous RuO2·H2O for the first time was employed to achieve fast and ultralong-life ...Rechargeable aqueous zinc-ion hybrid capacitors and zincion batteries are promising safe energy storage systems.In this study,amorphous RuO2·H2O for the first time was employed to achieve fast and ultralong-life Zn2+storage based on a pseudocapacitive storage mechanism.In the RuO2·H2O||Zn zinc-ion hybrid capacitors with Zn(CF3SO3)2 aqueous electrolyte,the RuO2·H2O cathode can reversibly store Zn2+in a voltage window of 0.4-1.6 V(vs.Zn/Zn2+),delivering a high discharge capacity of 122 mAh g?1.In particular,the zinc-ion hybrid capacitors can be rapidly charged/discharged within 36 s with a very high power density of 16.74 kW kg?1 and a high energy density of 82 Wh kg?1.Besides,the zinc-ion hybrid capacitors demonstrate an ultralong cycle life(over 10,000 charge/discharge cycles).The kinetic analysis elucidates that the ultrafast Zn2+storage in the RuO2·H2O cathode originates from redox pseudocapacitive reactions.This work could greatly facilitate the development of high-power and safe electrochemical energy storage.展开更多
Due to development of distribution systems and increase in electricity demand,the use of capacitor banks increases.From the other point of view,nonlinear loads generate and inject considerable harmonic currents into p...Due to development of distribution systems and increase in electricity demand,the use of capacitor banks increases.From the other point of view,nonlinear loads generate and inject considerable harmonic currents into power system.Under this condition if capacitor banks are not properly selected and placed in the power system,they could amplify and propagate these harmonics and deteriorate power quality to unacceptable levels.With attention of disadvantages of passive filters,such as occurring resonance,nowadays the usage of this type of harmonic compensator is restricted.On the other side,one of parallel multi-function compensating devices which are recently used in distribution system to mitigate voltage sag and harmonic distortion,performs power factor correction,and improves the overall power quality as active power conditioner(APC).Therefore,the utilization of APC in harmonic distorted system can affect and change the optimal location and size of shunt capacitor bank under harmonic distortion condition.This paper presents an optimization algorithm for improvement of power quality using simultaneous optimal placement and sizing of APC and shunt capacitor banks in radial distribution networks in the presence of voltage and current harmonics.The algorithm is based on particle swarm optimization(PSO).The objective function includes the cost of power losses,energy losses and those of the capacitor banks and APCs.展开更多
In order to increase the available power of the electrical energy distribution station and improve the voltage profile of the distribution lines, the use of shunt capacitor banks is indicated. The main results obtaine...In order to increase the available power of the electrical energy distribution station and improve the voltage profile of the distribution lines, the use of shunt capacitor banks is indicated. The main results obtained during this study are: a reduction in subscribed power from 14913.978 kVA to 14010.100 kVA, a reduction in the transformer load rate from 99.4% to 93.4%, a reduction in reactive power called from 5481.729 kVAr to 481.729 kVAr, an increase in the active power transported by the substation from 8505.062 kW to 8962.323 kW, a reduction in the voltage drop from 4.8% to 3.9%, an increase in the power available at the secondary of the transformer station at full load from 13950 kW to 14700 kW and an annual electrical energy saving of 339943.48 kWh of electrical energy, therefore fuel savings and a reduction in CO<sub>2</sub> and SO<sub>2</sub> emissions due to this energy saving will be achieved. The installation of capacitor banks for optimization of reactive energy allowed a reduction in the current called therefore a reduction in the absorbed power: 14153.061 kVA, i.e. a reduction of 903.876 kVA. It is therefore essential that energy players are convinced of the need to install capacitors to reduce or even eliminate their reactive energy bill. This is necessarily accompanied by an investment by Electricité De Guinée by setting up active and reactive energy meters but also by implementing pricing in line with the reduction in the transfer of reactive energy in the network.展开更多
The main purpose of the electrical power system is to transport and distribute energy generated by the central power plants in a safe and reliable manner to the customer premises. Most of the electrical equipment is e...The main purpose of the electrical power system is to transport and distribute energy generated by the central power plants in a safe and reliable manner to the customer premises. Most of the electrical equipment is exposed within the open which suggests they can be vulnerable to lightning strikes, road dwindling, windstorms, and a few engineering activities with the potential of causing different degrees of damage to the electrical equipment. One of the ways to guard the equipment is to deploy switching devices. However, the operations of most of these switching devices produce oscillatory transient in the electrical transmission and distribution systems which result in voltage, current, and frequency fluctuations in the load. This paper investigates the effect of switching devices on power quality and proposes a positive sequence voltage power transient suppression technique that can spontaneously improve the distorted voltage at the instant of capacitor switching using the capacitor line model as a case study. MATLAB/Simulink software was utilized for the analysis on an electrical network model with bus voltages of 69 kV/12.47 kV and 480 V. The results showed that, during switching operations, the positive sequence voltage power detector block produces ripple-free accurate results.展开更多
针对谐振式无线电能传输系统中分数阶电感、电容元件的仿真实现困难的问题,采用等效阻抗实现分数阶电容的等效.基于分数阶电容的阻抗特性,给出了一种分数阶RLC_(α)串联谐振双向无线电能传输(bidirectional wireless power transfer,BD-...针对谐振式无线电能传输系统中分数阶电感、电容元件的仿真实现困难的问题,采用等效阻抗实现分数阶电容的等效.基于分数阶电容的阻抗特性,给出了一种分数阶RLC_(α)串联谐振双向无线电能传输(bidirectional wireless power transfer,BD-WPT)系统结构,通过建立含分数阶电容的串联谐振式双向无线电能传输系统的电路模型,推导了其传输功率和效率关系.仿真实验结果表明,与整数阶串联谐振系统相比,系统的输出功率提升了7.82%,传输效率提升了0.58个百分点.展开更多
文摘This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly from high-voltage (HV) transmission lines to low-voltage (LV) consumers through coupling capacitors and is said to be cost-effective as compared to conventional distribution networks. However, the functionality of such substations is susceptible to various transient phenomena, including ferroresonance and overvoltage occurrences. To address these challenges, the study uses simulations to evaluate the effectiveness of conventional resistor-inductor-capacitor (RLC) filter in mitigating hazardous overvoltage resulting from transients. The proposed methodology entails using standard RLC filter to suppress transients and its associated overvoltage risks. Through a series of MATLAB/Simulink simulations, the research emphasizes the practical effectiveness of this technique. The study examines the impact of transients under varied operational scenarios, including no-load switching conditions, temporary short-circuits, and load on/off events. The primary aim of the article is to assess the viability of using an established technology to manage system instabilities upon the energization of a CCS under no-load circumstances or in case of a short-circuit fault occurring on the primary side of the CCS distribution transformer. The findings underscore the effectiveness of conventional RLC filters in suppressing transients induced by the CCS no-load switching.
文摘In order to improve the voltage quality of rural power distribution network, the series capacitor in distribution lines is proposed. The principle of series capacitor compensation technology to improve the quality of rural power distribution lines voltage is analyzed. The real rural power distribution network simulation model is established by Power System Power System Analysis Software Package (PSASP). Simulation analysis the effect of series capacitor compensation technology to improve the voltage quality of rural power distribution network, The simulation results show that the series capacitor compensation can effectively improve the voltage quality and reduce network losses and improve the transmission capacity of rural power distribution network.
文摘The large variability in wind output power can adversely impact local loads that are sensitive to poor power quality. To mitigate large swings in power, the wind turbine output power can be conditioned by using a small energy buffer. A power conditioner is developed to smooth the wind power output by utilizing the energy of an electrochemical capacitor, or ultracapacitor. The conditioner is based on a single phase voltage source inverter connected between the grid inter-connection point and the ultracapacitor. The VSI shunt inverter injects or absorbs active power from the line to smooth the wind power output by utilizing the short term storage capabilities of the ultracapacitor. The ultracapacitor is connected to the DC link through a bidirectional DC-DC converter. The bidirectional DC-DC converter and VSI are constructed and field tested on a Skystream 3.7 wind turbine installed at the Missouri University of Science & Technology.
文摘In this paper, a mathematical analysis of the EMI (Electromagnetic Interference) for a 20 kHz/10 kV capacitor charging power supply in frequency-domain is presented, and a related circuit model considering the transient switching interference is proposed. Due to the high working frequency and the device-switching transitions, the conducted EMI caused by the charging circuit which includes the harmonics of grid frequency, working frequency and device-switching transition frequencies. Thus under certain working situations or loads parallel power supply, the interference may cause charging failure. To solve this problem, a high frequency transformer modeled with stray capacitances and an approximation of the device-switching transition is applied in the Spice-based simulation model, and a mathematical analysis in frequency-domain is presented.
基金the financial support by the Australian Research Council through the ARC Discovery projects(DP160104340 and DP170100436)Rail Manufacturing Cooperative Research Centre(RMCRC 1.1.1 and RMCRC 1.1.2 projects)+1 种基金financially supported by the International Science&Technology Cooperation Program of China(No.2016YFE0102200)Shenzhen Technical Plan Project(No.JCYJ20160301154114273).
文摘Rechargeable aqueous zinc-ion hybrid capacitors and zincion batteries are promising safe energy storage systems.In this study,amorphous RuO2·H2O for the first time was employed to achieve fast and ultralong-life Zn2+storage based on a pseudocapacitive storage mechanism.In the RuO2·H2O||Zn zinc-ion hybrid capacitors with Zn(CF3SO3)2 aqueous electrolyte,the RuO2·H2O cathode can reversibly store Zn2+in a voltage window of 0.4-1.6 V(vs.Zn/Zn2+),delivering a high discharge capacity of 122 mAh g?1.In particular,the zinc-ion hybrid capacitors can be rapidly charged/discharged within 36 s with a very high power density of 16.74 kW kg?1 and a high energy density of 82 Wh kg?1.Besides,the zinc-ion hybrid capacitors demonstrate an ultralong cycle life(over 10,000 charge/discharge cycles).The kinetic analysis elucidates that the ultrafast Zn2+storage in the RuO2·H2O cathode originates from redox pseudocapacitive reactions.This work could greatly facilitate the development of high-power and safe electrochemical energy storage.
文摘Due to development of distribution systems and increase in electricity demand,the use of capacitor banks increases.From the other point of view,nonlinear loads generate and inject considerable harmonic currents into power system.Under this condition if capacitor banks are not properly selected and placed in the power system,they could amplify and propagate these harmonics and deteriorate power quality to unacceptable levels.With attention of disadvantages of passive filters,such as occurring resonance,nowadays the usage of this type of harmonic compensator is restricted.On the other side,one of parallel multi-function compensating devices which are recently used in distribution system to mitigate voltage sag and harmonic distortion,performs power factor correction,and improves the overall power quality as active power conditioner(APC).Therefore,the utilization of APC in harmonic distorted system can affect and change the optimal location and size of shunt capacitor bank under harmonic distortion condition.This paper presents an optimization algorithm for improvement of power quality using simultaneous optimal placement and sizing of APC and shunt capacitor banks in radial distribution networks in the presence of voltage and current harmonics.The algorithm is based on particle swarm optimization(PSO).The objective function includes the cost of power losses,energy losses and those of the capacitor banks and APCs.
文摘In order to increase the available power of the electrical energy distribution station and improve the voltage profile of the distribution lines, the use of shunt capacitor banks is indicated. The main results obtained during this study are: a reduction in subscribed power from 14913.978 kVA to 14010.100 kVA, a reduction in the transformer load rate from 99.4% to 93.4%, a reduction in reactive power called from 5481.729 kVAr to 481.729 kVAr, an increase in the active power transported by the substation from 8505.062 kW to 8962.323 kW, a reduction in the voltage drop from 4.8% to 3.9%, an increase in the power available at the secondary of the transformer station at full load from 13950 kW to 14700 kW and an annual electrical energy saving of 339943.48 kWh of electrical energy, therefore fuel savings and a reduction in CO<sub>2</sub> and SO<sub>2</sub> emissions due to this energy saving will be achieved. The installation of capacitor banks for optimization of reactive energy allowed a reduction in the current called therefore a reduction in the absorbed power: 14153.061 kVA, i.e. a reduction of 903.876 kVA. It is therefore essential that energy players are convinced of the need to install capacitors to reduce or even eliminate their reactive energy bill. This is necessarily accompanied by an investment by Electricité De Guinée by setting up active and reactive energy meters but also by implementing pricing in line with the reduction in the transfer of reactive energy in the network.
文摘The main purpose of the electrical power system is to transport and distribute energy generated by the central power plants in a safe and reliable manner to the customer premises. Most of the electrical equipment is exposed within the open which suggests they can be vulnerable to lightning strikes, road dwindling, windstorms, and a few engineering activities with the potential of causing different degrees of damage to the electrical equipment. One of the ways to guard the equipment is to deploy switching devices. However, the operations of most of these switching devices produce oscillatory transient in the electrical transmission and distribution systems which result in voltage, current, and frequency fluctuations in the load. This paper investigates the effect of switching devices on power quality and proposes a positive sequence voltage power transient suppression technique that can spontaneously improve the distorted voltage at the instant of capacitor switching using the capacitor line model as a case study. MATLAB/Simulink software was utilized for the analysis on an electrical network model with bus voltages of 69 kV/12.47 kV and 480 V. The results showed that, during switching operations, the positive sequence voltage power detector block produces ripple-free accurate results.
文摘针对谐振式无线电能传输系统中分数阶电感、电容元件的仿真实现困难的问题,采用等效阻抗实现分数阶电容的等效.基于分数阶电容的阻抗特性,给出了一种分数阶RLC_(α)串联谐振双向无线电能传输(bidirectional wireless power transfer,BD-WPT)系统结构,通过建立含分数阶电容的串联谐振式双向无线电能传输系统的电路模型,推导了其传输功率和效率关系.仿真实验结果表明,与整数阶串联谐振系统相比,系统的输出功率提升了7.82%,传输效率提升了0.58个百分点.